Tender For Provision Of Training Sheds For Asc Centre (North) - 1 Atc Under Ge (Central) Bangalore.; 1 Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in Soft/loose soil complete all as specified and as directed. 2 Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc. or for shafts, well, cesspits, manholes, peir holes,for laying of cables/errection of poles/stay assembly etc. n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. 3 M&L for PCC (1:4:8) type D2 ( using 40mm gradedcrushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. 4 M&L for hardcore or gauge of broken stone or boulders n.exc 63mm, deposited spread and levelled in layers n.exc 15cmthick, watered and rammed to a true surface complete all as specified and as directed. 5 M&L for Pre-cast cement concrete block (1:3:6) type C1 (using 20mm gradedcrushed stone aggregate) masonry with solid blocks, exc. 10 cm in width and setting in cementmortar (1:6), complete all as specified and directed. 6 M&L for 100 mm thick PCC (1:4:8) type D2 ( using 40 mm graded crushed stone aggr)in sub base, floor.complete all as specified and directed. 7 M&L for Machine cut Kota stone slab flooring 20 to 25mm thick laid over 20mm thick screed bed in CM (1:6)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto and including mirror finish complete all as specified and as directed. 8 M&L for Machine cut Kota stone slab flooring 20 to 25mm thick in steps, skirting and dado overand including 15mm thick backing coat in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto and including mirror finish complete all as specified and as directed. 9 M & L for RCC design mix (M-25 ) using20mm graded stone aggregate for foundationfootings, plinth beams, columnsup to GL etc complete all as specified and as directed.(Note : Reinforcementshall be measured and paid seperatelyunder relevant item.) 10 M & L for RCC Design mix (M-25) using 20mm graded stone aggregate for column above GL , lintel beam , chajja, roof beam and slab or similarsuspended work etc. complete all as specified and as directed.(Note : Reinforcement shall be measured and paid seperately under relevant items.) 11 M & L for 10 mm dia and over TMT bars cut to length bent to shape as required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. 12 All as per item No.11above but6 to 8mm dia round bars as in stirrups and -ditto- 13 M&L for formworkflat, rough finished surface of concretefor side of footingcolumns, plinth beams or similar workincludingany types of supports/scafoldingsetc complete all as specified and as directed. 14 M&L for form workFormwork to sides of pillars,posts, struts, piers,columnsand stanchions complete all as specified and directed. 15 M&L for Formwork to sides and soffits offloor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelvesincluding sup- ports, overhangs,etc. also splays between floors andbeams, etc.complete all as specified and as directed. 16 M&L for Rooftrusses (framed), trussed,purlins, crane gantries, rails andfastenings and heavy bracketframing (Beam, tee, angle, channelor flat sections) includingdistance pieces, cleats etccomplete all as specified and directed. 17 S&F Plates (plain or chequered)channels,squarecutor notched(ordinaryand countersunk)forming holes, without anyattachment complete all as specified and directed. 18 M&L forpreparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying 2 coats of Synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. 19 S&F coloured pre-paintedGalvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strngth of 550 Mpa and 150 AZ as in roof covering /cladding to wall fixed with self tapping screwsincluding necessary washers etc all as per manufactures instruction complete all as specified and directed. 20 S&F pre-painted galvalume aluminium zinc coatingGI based plain sheet steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa150 AZ as in roof covering/cladding to wall, eaves board fixed with self tapping screws complete all as specified and as directed. 21 Returningfilling in, including spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed . 22 Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed. 23 M & Lfor rendering15 mm thick in CM (1 : 6) on anyfaces of stone masonry or concrete block surfaces,finished even and smooth without using extra cement complete all as specified and as directed. 24 M & Lfor preparation of newly plastered surfaces of walls of any description over 10cm girth or width not otherwise described and applying three coats of white wash complete all as specified and directed. 25 M & Lfor rendering15 mm thick in CM (1 : 4) on anyfaces of stone masonry or concrete block surfaces,finished even and smooth without using extra cement complete all as specified and as directed. 26 M&L for preparation of newly plastered wallsurfaces and applyingtwo coats ofcement base paintcomplete all asspecified and directed. 27 Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and as directed. 28 Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc. or for shafts, well, cesspits, manholes, peir holes, etc. n.exc 10 Sqm on plan and getting out in hard/dense soil complete all as specified and as directed. 29 M&L for machine pressed precast conctete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade With Grey and pigment laid over 50 mm thick sand cushion and compacted with mechanical plate vibrator complete all as specified and as directed. (Note :Sand filling shall be measured and paid separately). 30 M&L for Sand filling and sand cushioning under floors or in foundations including watering and consolidation complete all as specified and directed. 31 M & L for Point wiring with PVC insulated and unsheathed FRLSmultistranded copper conductor cable conforming to IS specification with 2 runs of 1.5Sqmm including one run of 1.5sqmm single core multistranded copper condutor , 1100 volts grade cable conforming to anddrawn in and including 25mm steel conduit and conduit accessories on surfaceincluding modular plate , cover and metalflush box fixed with wall surface for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. 32 M & L for sub main wiring with PVC insulated and unsheathed FRLSmultistranded copper conductor cable conforming to IS specificationwith 2 runs of 2.5Sqmm including one run of 2.5sqmm single core multistranded copper condutor , 1100 volts grade cable conforming to anddrawn in and including 25mm steel conduit and conduit accessories on surfaceincludingincluding 2.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. 33 Supply and fix modular switch 1 way 6A,1 module complete all as specified and directed. 34 Supply and fix modular shutter socket outlet 3 pin 6Amps 230 volts 2 module complete all as specified and directed. 35 Supply and fix modular switch 1 way 16A,1 module complete all as specified and directed. 36 Supply and fix modular shutter socket outlet 3 pin 6/16 Amps 230 volts 2 module complete all as specified and directed 37 S&F LED tube light fitting of20 watts 6000K , 230 volt, withbasic all purpose surface and wall mounted LED batten with aluminium extruded housing & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed . 38 S&F Bldg securitylight fittings 1x 35 Watt LED street light with New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with all accessories and including connection up with twin core twisted flexible copper conductor cable with 1.5 M long suitable size and25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size32mm X 5 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole complete all as specified and directed. 39 Supply and fix of Sheet metal enclosure (ISI marked) distribution board SPN, 240 volts, 8 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified. 40 Supply and fix RCBO Double pole 30mA, 240 volts, 16amps 10 kA rupturing capacity complete all as specified and directed. 41 Supply and fix MCB single pole 6 to 32 Amps 240 volts, C series,10 kA rupturing capacity complete all as specified and directed. 42 M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thickburied directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4mm dia by means ofof nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified and directed. 43 Supply and laying of XLPEAluminiumstranded cable Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Size of 10 sqmm x 2 core complete all as specified and directed. 44 Supply and lay common burnt old size bricks of sub class B laid at right angle on the cable complete in trenches for cable protection complete all as specified and directed. 45 Supply and spreading clean dry river sand in trenches for cushioning of UG cables complete all as specified and directed. 46 Supply and fixing GI tubing light grade 40 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wallcomplete including taking out if required complete all as specified and directed.