Tender For Special Repair To Bldg No Np-1 & Np-2 Rp Store & Sqm Store Of 75 Med Regt Under Ge (North) Meerut Cantt.; 1 Demolition ofbrick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc complete all as specified & directed. 2 M&Lold size brick work with sub classfly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 Complete all as specified and directed. 3 M&L old sizebrickwork with subclass `B bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks Complete all as specified and directed. Note :- Old serviceable bricks retrived from demolition shall be re-used under this item. 4 Demolition of cement concrete of ground floor n exc 15 cm in depthin any position nototherwise specifically provided for complete all as specified & directed. 5 Demolition of Stone slabs and tiles of any description or thickness in floors, apronslaid and pointed in any mortor etc complete all as specified & directed. 6 M&L for 18-20mm thick black granite stone slab machine cut in cooking platform, jams, pillars, windows cills and the like laid over and including 15mm thick screed bed or backing coat in cement mortar (1:4) and jointedwith grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed. 7 M&L for 18-20mm thick black granite stone slab machine cut in skirting/dado, cooking platform, jams, pillars, windows cills and the like laid over and including 10mm thick screed bed or backing coat in cement mortar (1:4) and jointedwith grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed. 8 M&L machine cut prepolished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing uptoGranite finish complete over 15mm thick screed bed in CM 1:6complete all as specified & directed. 9 All as per item No 8 above but factory made bull nosed as in riser of steps, skirting/dadolaid over10mm thick in cm 1:4 complete all as specified & directed. 10 Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each complete all as specified & directed. 11 Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqn each complete all as specified & directed. 12 S&F powder coated anodised aluminium windows slidingtype (3 shutter type) with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) inclstainless steel mosquito proofing wire mesh fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame, grill with one or more rebates including S&F 5.50 mm thick black glass complete all as specified and directed. 13 M&L, in repair, 18/19mm thick Soild WPC board, exterior grade, prelaminated one side with decorative choice laminations and other side balanceing white lamination, fixed with screws to WPC frame work in cup boards, rebated or flat edged fancyhandle , Magnite lock complete all as specified and directed. 14 M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290 Gde E-165 complete all as specified & directed. 15 M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamelover one coat of primer complete all as specified & directed. 16 S & F 30 mm flaps Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified & directed. 17 Supply & fix 125mm size aluminium alloy handles cast type anodized complete all as specified & directed. 18 Supply & fix 150mm size aluminium alloy handles cast type anodized complete all as specified & directed. 19 S&F aluminium anodised tower bolts 150mm long, of extruded section complete all as specified & directed. 20 S&F aluminium slidingbolt 300 long bolt type with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed. 21 S&F heavy weight butt hinges 100mm in sizecomplete all as specified and directed. 22 S&Faluminium anodised barrel tower bolt with bright bolt 200 mm long. complete all as specified & directed. 23 Taking down of cementplaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed. 24 M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. 25 M&L Rendering 5 mm thickon fair faces ofbrick workor concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified & directed. 26 M & Lfor applying 15 mm thick rendering usingin CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed :Note:- Water proofing compound shall be measured and paid sepratly 27 M&L for applying 2 mm thick wall care putty making smooth surface complete all as specified and directed. 28 Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces using roller for painting complete all as specified & directed. 29 M&L For preparation of old surface after complete removal of existing treatment by mechanical complete all as specified and directed 30 M&L for 1 coat of prime using roller complete all as specified and directed. 31 M&L for Two coat of OBD using roller for painting complete all as specified and directed 32 M& L preparing plastered un plasterednew surfaces on ceiling and applying three coats of white wash on ceiling surface complete all as specified & directed. 33 M& L preparing plastered un plasteredold surfaces on ceilingone coat of white wash complete all as specified & directed. 34 M&L for preparation of newly plastered surfaces of wall by applying wall care putty averaging thickness 2mm and rubbing with sand paper for making smooth surface and applying two coat of oil emulsion distemper over one coat of primerthrough roller, complete all as specified and directed . 35 M&L preparation of Complete removal of existing treatment plastered old surface of of wall by applying 2mm thick wall care putty and making the surface smooth Finishing walls and applyingAcrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)using roller for painting complete all as specified and directed. 36 S&F for factory made gauzed shutter made out of angle iron 35 mmx 35 mmx 5 mm and 25 mmx 25 mmx 5 mm and 1.5 mm thick, 10 mm square bars grill with stainless steel fly proof wire mesh having stainless steel 0.5mm nominal dia wireand 1.20mm average width of aperture includingtwo coats ofsynthetic enamel paint over a coat of red oxide primer complete all as specfied and directed. 37 Demolition of reinforced concreteof any description and any poisition not otherwise specifically provide ( reinforcement cut to faciliatate demolition) complete all as specified & directed. 38 M&L Form work to sides and soffits of beams lintels etc finishedrough complete all as specified & directed. 39 M & L RCC 1:2:4 Type B0 (using 12.5mm graded stone aggregate) as in beams, lintels, bressummers over 1.5 m span etc complete all as specified & directed. 40 M & L precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggegrate) as in Chullah hood chajja and manhole cover, kitchen shelves etc set in cement mortar 1:4.including all neccesary formwork & finishing exposed concrete surface complete all as specified & directed. 41 Cutting chases ,pinning in brick work girth exc 10cm but n exc 20 cm and making good to facing where required and poiningein cement mortar 1:3 to ends of edges of landing, sun shades, chajjas, shelves etc complete all as specified & directed. 42 S&F mild steel TMT bars No 500D 10mm dia and over, cut to length bent to shape requiredincluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including MSwire (annealed) not less than 0.9mm dia or securing clips complete all as specified and directed. 43 ditto as per item no 42 abovebut 6 to 8 mm dia complete all as specified and directed. 44 S&F in repair 140mmover all length with flap floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed. 45 S & F in repair 25mm dia Stainless steeldecorated curtain rod with braket and ring complete all as specified and directed. 46 Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors soil complete all as specified & directed. 47 Treatment the soil under plinth protection at the rate of 5 litres of emultion per square meter of surfaces area complete all as specified & directed. 48 M&L for dubbing out average 20mm thick on irregular faces of walls and ceilings CM 1:4 complete all as specified & directed. 49 M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labore in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site and as directed by Engr-in-Charge 50 Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed. 51 Material & Labour for 50mm thick average thickness ofPCC 1:2:4 type B-O(using 12.5 mm graded stone aggregates)complete all as specified & directed. 52 Material and Labour for 10mm thick cement paster in CM 1:4 mixed with WPC @ 2 % by weight of cement finised even and smooth without using extra cement on roof surface when concreate is green and wall complete all as specified & directed. Note :- WPC will be measured and paid seperately as supply only rate. 53 Supply only liquid water proofing compound complete all as specified & directed. 54 Material & labour for cleaning of concrete or plasteredsurfaces of roof and applying priming coat using with bituminous primer @ 0.30kg per Sqm followedevenly by a tack coat @ 1.20 kg per Sqm using 85/25 grade industrial hot blown bitumen, over it laid with 3mm thickAPP modified polymeric waterproofing membrane reinforced with non-woven polyester fabric (weightnot less than 160 Gm per Sqm) unrolled & bonded to substrate with side and end laps 75mm & 100mm as per manufacturer’s instruction andapplying over it a tack coat using 85/25 grade industrial hot blown bitumen bitumen @ 1.20 kg per Sqm and finally finished the top of polymericwater proofing membrane with a coat of bituminous aluminum paint @ 0.20 kg per Sqm as per manufacturer’s instructions, complete all as specified & directed. (including existing water tank on roof disconnected and after cleanig same positionconnecting) 55 M&L, Broken stone or boulder Hardcore of guage n exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick , watered and rammed to a true surfaceetc complete all as specified & directed. 56 M&L machine pressed 60mm thickM-35 Gde conforming to IS 15658-2006 coloured precast cement concrete interlocking paver block with pigment over sand cushioning, ineterlocking tiles jointd filled with sand complete all as specified & directed. Note :- Sand cushioning shall be measured & paid seperately. 57 M&L Sand for cushioning, including spreading and levelling in layers n exc 25 mm thick complete all as specified & directed. 58 M & L 75 mm thick cement concrete 1:4:8 type D-2 using (40 mm graded stone agg) as in sub base complete all as specified & directed. 59 Taking down carefully any type of battens or conduit point wiringwith conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge. 60 Material and labour for point wiringwith 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, unsheathed, copper conductor cable in and including PVC concealed conduit of any size/dia complete with all accessories/fittings, brass screws, washer etc, sunk zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth duly complete all as specified and directed for the followings :- 61 One tube light/Bulb/ street light point controlled by one, one way switch 05 / 06 Amps complete all as specified & directed. 62 One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch complete all as specified & directed. 63 One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch complete all as specified & directed. 64 All as per serial item No 60.03 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board complete all as specified & directed. 65 Supply and fixswitch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed. 66 Supply and fix insocket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed. 67 Supply & fixing of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed. 68 Supply and fix inswitch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed. 69 Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed. 70 Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate all as specified and directed. 71 Supply and fixing LED lamp 2 pin 9 watt complete all as specified & directed. 72 Supply and fixing LED light fitting 1x20 watt,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 73 Supply and fixing 1x36/40W LED Building security lightenergy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver including security light brackets of 32 mm dia GI pipe medium grade upto 1.2 mtr long bend to shape at 100-120 degree including flat iron clamps and Suitable nuts and bolts grouted in wall including all material required for fitting all as specified and directed. 74 S&FTPN DB, 4 way, 415 V, double door type suitable for mounting incoming and outgoing MCB’s double pole/single pole,complete all as specified and directed. 75 Supply & fixingfour pole Isolator ,415 V, 63A, and making connections complete all as specified & directed. 76 Supply and fixing MCB, SP, AC, 240 volts C curve capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed. 77 Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed.