}

Tender For Special Repair To Bldg No P-139 At Fazilka Mil Station., fazilka-Punjab

Military Engineer Services has published Tender For Special Repair To Bldg No P-139 At Fazilka Mil Station.. Submission Date for this Tender is 27-08-2025. Building Work Tenders in fazilka Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

50663776
Tender For Special Repair To Bldg No P-139 At Fazilka Mil Station.
Tender
Indian
Punjab
Fazilka
27-08-2025

Tender Details

Tender For Special Repair To Bldg No P-139 At Fazilka Mil Station.; 1 Taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified and directed by Engineer - in-Charge. 2 Taking down chowkatswith shutters(without taking off shutters from the frameexceeding 1.50 sqm each but not exceeding 4 sqm) removing to store all as specified and directed by Engineer - in-Charge. 3 Dismantling of boarding, any description, fixed in position with nail 4 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 5 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type skelton door shutter of size 30mm thick open rebated and prepared to receive glass, gauge etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVCfoil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 6 S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 7 Ditto as per item No. 16 Above but of frame size 65 x 100 mm 8 Ditto as per item No. 16Above but of frame size 65 x 125 mm 9 Material and labour for providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet (for shutter, sides of cabinet, partition and shelves etc). All the edges of shutter and front exposed edge of partition/shelves shall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge.Note :- (i) The area of each sheet (shutter, sides of cabinet, partition and shelves)shall be measured in sqm for payment. (ii)Magnetic catcher, handles, continuous Piano hinges and PVC frame (where required) shall be measured and paid separately under appropriate item of BOQ.(iii) Any other material required for making/fixing/hanging of cabinet shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 10 Material and labour for modular wardrobe cabinet shutter in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet for shutter fixed with and incl powder coated aluminium frame section/channel including PVC rollers,brass locking device and handle in each shutter. All the edges of shuttershall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge. 11 S & F 100 mm long butt hinges, medium weight, cold rolled mild steel and fixed complete/ 12 S&F 125 mm long Aluminium handle cast type anodized all as specified and directed by Engineer-in-Charge. 13 S&F 150 mm long Aluminium handle cast type anodizedall as specified and directed by Engineer-in-Charge. 14 S&F 150 mm long Aluminium anodized barrel tower bolt of extended section and fixed all as specified and directed by Engineer-in-Charge. 15 S&F 200 mm long Aluminium anodized barrel tower bolt of extended section and fixedall as specified and directed by Engineer-in-Charge. 16 S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing boltsand sliding bolts of extruded sections or cast aluminium alloy all as directed. 17 S&F Aluminium door stopper of any description all as specified and directed by Engineer-in-Charge. 18 S & F continous (Piano)type hinges mild steel bright finish or lectro galvanised with wide of flaps30mm complete all as spd and directed. 19 S&F magnet ball catcher for cupboard shutter, complete all as specified and as directed by Engineer-in-Charge 20 S&F 125 mm size hasp and staple,aluminium anodished,including bolt to hinge plate and fixed with screws,complete all as directed. 21 S&F in repair MS 300mm ordinaryrat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge. 22 S&F 25 mm dia Stainless steel drapery curtain rod, 25mm dia with decoative brackets,knobs,end stops etc and fixed to walls complete all as specified and directed by Engineer-in-Charge. 23 S & F4mm thick sheet glass ordinary quality and glazing with aluminium glazing beading clips not exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer - in-Charge. 24 S & F 4 mm thick figured glass pin headed and glazing with aluminium glazing beading clips in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer - in-Charge. 25 S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed. 26 S&Fpowder coated anodized aluminum frame for doors, windows , ventilators with one of more rebates including joining cleat for fixing etc. completed all as specified 27 S&F powder coated aluminum anodizedgrill diamond shape 100mm x 100mm aperture of 6 mm dia roundbars including necessary joining cleats, clips anodised complete all as specified. 28 S & Fpowder coated aluminum sliding window three track with frame & two glass shutter using 4 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminum powder coated section aluminum cleat , PVC track, bearing, handle lock rubber beading etc complete fittings as approved. Note :- Size of aluminum section shall be under – (i) three track top and vertical – jindal main 2010. Section No 20621 or equivalent as approved by GE.(ii) Three track bottom – Jindal main – 2010 section 20620 orequivalent as approved by GE.(iii)Shutter Vertical Section - Jindal main – 2010 section 20604 orequivalent as approved by GE.(iv) Shutter top and bottom - Jindal main – 2010 section 20604 orequivalent as approved by GE.(v) Shutter vertical middle ( interlock) - Jindal main – 2010 section 20605 orequivalent as approved by GE. 29 S&Fpowder coated aluminumWindow/Ventilators shutter side hung type without sash, aluminum section weighing glazed clips, rubber packing anodized aluminum fittings such as peg stays 150 mm long (1 nos)hinges type B-21 100 mm long (2 Nos) suitable handle (1 Nos) complete all as specified. 30 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. 31 S&F 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and directed by Engr-in-charge. 32 S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame all as per specification and drawing. 33 S&F Solid PVC Wall Lining consisting of 5mm thicksingle side colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing 34 Demolation of ashlar facings, dressed stone work, stone slabs or tiles from paving and precast concrete blocks and articlesall as specified.& directed by Engineer -in-charge.. 35 M&L16-18mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and likein 15mm thick cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shed of granite. 36 M&L for 16mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. 37 Providing edge moulding to 16mm thick granitestone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete 38 M&L machine cut kota stone slab flooring 16-18mm thick in single piece over cement screed base laid and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6)all as directed by Engineer-in-Charge. 39 M&L forkota stone slab flooring 16-18mm thickin single piecein riser of steps,skirting,dado and pillar laid and jointed with grey cement mixed with pgment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6)all as directed by Engineer-in-Charge. 40 Cutting ,grinding ,cleaning and treating the surface of existing kota stone flooring with beeswax polishing complete as directed by Engr-in-Charge. 41 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises. 42 M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge. 43 M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick( square /rectangular ) joint free tiles area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engr in Charge. 44 M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tile shade complete all as specified and directed by Engr in Charge. 45 M&L vitrified ceramic coloured /printed tiles(HDVT) 10mm thick (square /rectangular ) joint free tiles area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engr in Charge. 46 M & L 20mm thick screed bed on concrete surfacesin CM 1:4 finished even & fair to receive floor tiles comlpete all as specified and directed by Engineer - in - Charge . 47 M & L rendering 10mm thick on fair faces of brick work or concrete surfacesin CM 1:3 finished even & fair to receive wall tiles comlpete all as specified and directed by Engineer - in - Charge . 48 Demolitionof cement concrete (un re-inforced) of any description in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. 49 M & L 25 mm thick Cement Concrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge . 50 M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. 51 Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. 52 M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . 53 Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. 54 M & L 10mm thick rendering in Cement Mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge . 55 M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge . 56 M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:4 mixed with water proofing compound 3%by weightof cement finished even & smooth without using extra cement ( WPC shall be measured & paid separately) cement all as specified and directed by Engineer - in - Charge . 57 Supply only liquid water proofing compound 58 Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge. 59 Demolition/taking out of mud from roofs, any thickness, including removing / cutting uprooting grass,vegetations and roots of small plants etc on roof and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge 60 M & L for levelling coarse for roof slab,PainCement Concrete 1:2:4 (type B–0 using 12.5mm graded stone aggregates) for maintaining prooper slope and finishing the surface even and smooth complete all as specified and directed by Engineer - in – Charge . 61 M & L PCC 1:2:4, type B-1 , using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work all as specified and as directed. 62 M&L forrendering10mm thick plasterin cement mortar (1:4) shall be provided mixed with water proofing compound, ISI markedas per manufacturer instructions. The plaster shall be steel toweled to get a smooth surface. 63 M&L for roof treatment as specified below and as directed -(a) Over the plastered surface apply one coat of compactible primer for PU coating as per manufacturer specification. Allow the primer to touch dry condition.(b) Apply first coat of PU coating (Shaliurethane @ LHM @650gm/Sqm (minimum) or equivalent) by brush/roller/spray, spread water proofing reinforced glass fiber Tissue of 150 GSM with overlaps of 75mmin both directions when the surface is still tacky. Alloow 1st coat to dry for 10-12 hr.(c) Apply 2nd and 3rd coat of PU membrane (Shaliurethane @ LHM @650gm/Sqm (minimum) or equivalent) as per as per manufacturer instructions having sun reflective index (SRI) of minimum 106 on top of roof surface after application. Extend water proofing treatment upto 200mm and terminate into groove on the parapet wall.Note :(i) The minimum thickness of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat.(ii) the plan area shall be considered for payment.(iii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicater approved by GE.(iv) trhe manufacturer/authorised applicator shall give a warranty for the performance and durability for 10 years. 64 Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for. 65 M & L RCC 1:1½:3, (nominal mix), Type A-1, using 20mm graded aggregates as in chajjas, fins, fascias,shelves , louvers, parapets and railing etc and the like including necessary formworks all as specified and directed by Engineer - in - Charge. 66 S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. 67 M&L for providing precast cement concrete louvres and jallies 1:2:4 type B-0, 25mm thick (measured solid) set in cement mortar 1:4, including all mould- ings but excluding frame complete all as specified and directed by Engr-in-Charge. 68 M&L 50mm thick PCC1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection, surface finished even smooth without using extra cement. 69 Dismantling of CI pipes or reinforced concrete pipes 100 mm dia fixed to wall etc complete all as specified and directed. 70 Dismantling of CI pipes or reinforced concrete pipes 75 mm dia fixed to wall etc complete all as specified and directed. 71 Taking down eves and gutter and rain water of any size all as specified and directed by Engineer - in - Charge . 72 S&F 110mm PVC (SWR) pipes single socketed(pressureratingnotlessthan 6kg/sqcm)in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 73 Supply&fixing110mmborePVC(SWR)pipessinglesocketed(pressureratingnotlessthan 6kg/sqcm)inanylengthwithrubberringjointsfordrainorrainwaterfixedalongwallswithand including PVC clamps, complete all as specified and as directed by Engineer-in- charge. 74 Supply&fixing75mmborePVC(SWR)pipessinglesocketed(pressureratingnotlessthan 6kg/sqcm)inanylengthwithrubberringjointsfordrainorrainwaterfixedalongwallswithand including PVC clamps, complete all as specified and as directed by Engineer-in- charge. 75 S&F 75mm PVC (SWR) pipes single socketed (pressureratingnotlessthan 6kg/sqcm)in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 76 Supply&fixingPVC(SWR)bends(anyradius)suitablefor110mmborepipecompleteallas specified and as directed by Engineer-in- charge. 77 Supply&fixingPVC(SWR)bends(anyradius)suitablefor75mmborepipecompleteallas specified and as directed by Engineer-in- charge. 78 Supply&fixingPVC(SWR)floortrap,plainwithgrating,suitablefor100/75mmborepipeincluding jointing with solvent cement complete all as specified and as directed by Engineer-in- charge. 79 Supply and fixing PVC (SWR) reducer 110/75 complete all as specified and as directed by Engineer-in-charge. 80 Supply & fixing PVC (SWR) vent cowl suitable for 75mm bore PVC pipe complete all as specifiedand as directed by Engineer-in- charge. 81 Supply & fixing 110mm bore PVC (SWR) junction single (single T) equal or unequal fixed with solvent cement, with access door complete all as specified and as directed by Engineer-in- charge. 82 S&F 110mm PVC(SWR) sanitary connection socket to fit out let of WC complete all as specified and directed. 83 Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store 84 Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store 85 S&F Chlorinated PVC (CPVC) pipes 20 mm outer dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.0 m spacing . this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified and directed. Make : Supreme/Vectus or equivalent 86 Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified. 87 S&Fin repair gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia all as directed. 88 S&F 32mm bore for discharge pipe Bottle trap of stainless steel having minimum water seal of 25mm 89 S&F in repairs wall mounted vitreous china wash down water closet pan padestel pattern white including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and including Jet spray and plastic seat cover with mild steel chromoum plated hinging and P or S trap device complete all as specified and directed by Engineer-in-Charge.Make ;- cat part No. ARS-WHT-0110 of Jaquar or equivalent as approved by garrison Engineer. 90 S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 91 S&F in repair PVC concealed type flushing cistern set of capacity 10 ltr with half frame including all fixing accessories and knob fixed in wall and including flush pipe of PVC 32mm bore and connection to WC pan making good dismantled portion of wall complete all as specifed and directed. Make:Cera cat part No B1110112 or equivalent 92 S & F in repair vitreous china whitetable top wash basin of size185 x 490 X410 mm including brackets,waste fitting 32 mm brass chromium plated complete all as specified and as directed.Make ;- cat part No. FNS-WHT-0540 of Jaquar or equivalent as approved by garrison Engineer. 93 S&F PVC waste pipe 32mm dia & 90 cm long all as specified and directed by Engineer-in-Charge 94 S&F 600mm dia modular circular type beveled edge mirror of selected quality glass with touch screen pattern type lighting system fixed with brass screw and cup washes fixedin repaire complete all as specified and directed. 95 S&F in repair bib taps long body, 15mm bore dia, fancy type, cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified. 96 S & F in repairs 15mm bore CP Angle cock one waychromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified . 97 S&F in repairs 15mmstop valves fancy type, chromium plated with long shank and cup (concealed type) ,cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed. 98 S & F in repair brass chromium plated central hole basin mixer with regular spout , popup waste system and 450mm long braided hoses with connection and nuts completeall as specified and directed by Engr-in-charge. 99 S & F in repairs brass chromium plated wall mixer with telephonic shower arrangement incl with CP 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in positionfor mixing hot and cold water screwed down for iron pipe and fixed as directed by Engr-in-charge : Make : Jaquar/ESS ESS/Prayag or equivalent. 100 S& F in repairs for brass chromium plated over head shower rose oval shape single flow 300 x 200 mm size with swivel joint including fixing to 15 mm dia steel pipe or union.Make :Cat part No. OHS-49497 ofJaquar or equivalent. 101 S & F soap dish holder brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge.Make ;- cat part No. AKP-35731P of Jaquar or equivalent as approved by garrison Engineer. 102 S & F soap dish dispenser with glass bottle brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge.Make ;- cat part No. ACN-1135N of Jaquar or equivalent as approved by garrison Engineer. 103 S & Fbrass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge .Make ;- cat part No. AKP-35711P of Jaquar or equivalent as approved by garrison Engineer. 104 S & F in repairs stainless steel towel rack with hook, mirror finish,polished,rust proof, foldable with multi purpose hooks (min. weight 1.5 Kg) complete all as specified and directed.Make ;- cat part No. AHS-1581H of Jaquar or equivalent as approved by garrison Engineer. 105 S&F CP stainless steel toilet paper holder complete all as specified and directed.Make ;- cat part No. AHS-1553 of Jaquar or equivalent as approved by garrison Engineer. 106 S & F in repairs glass corner shelf assembly fancy type made 8 mm thick sheet glass of size 300x300mm fixed with F or D type brass CP brackets complete all as specified.Make ;- cat part No. ACN-1173 of Jaquar or equivalent as approved by garrison Engineer. 107 S&F in repair CP grating suitable for 75/100 mm bore floor trap and fixed with white cement. 108 S&F in repair PVC connection both side brass unions internal for size 15mm dia and 600mm long all as specified and directed by Engineer-in-Charge. 109 Dismantling water tanks and removing to store of 500 ltr capacity 110 S&F rotational moulded polythene water storage tank (Cylindrical vertical withclosed top) hoisted and fixed in position of 500 ltrs capacity fixed with PVC tank nipples,complete all as specified in SSR Part I. 111 S&F in repair 20 mm float ball valve high pressire of PTMT with epoxy coated aluminium rod & high density platic ball screwed for iron pipe and fixed. ( Min weight 15 mm - 142 gms/20 mm 210 gms/25 mm 455gms/40mm 690 gms) 112 M & L for complete removal of existing treatment and applying two coats of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in - Charge . 113 M & L applying three coat of white wash on newly plastered or unplastered wall surface including preparation ofsurfaces, complete all as specified. 114 M & L for preparation of old surfaces by complete removal of existing treatment of painted walls incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specification complete all as specified and directed. 115 M & L for preparation of old surfaces by complete removal of existing treatment of painted ceiling incl beams etc. by mechanical equipments like electric wall sander/water jet machine and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specification complete all as specified and directed. 116 M & L for preparation of old surfaces by complete removal of existing treatment of painted wall/ceiling incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces complete, by mechanical means as per manufacturers specification complete all as specified and directed. 117 M & L for preparation of new surfaces of walls incl pillar etc. and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specification complete all as specified and directed. 118 M & L for preparation of new surfacesof wall/ceiling incl pillars etc. and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by mechanical means as per manufacturers specification complete all as specified and directed. 119 Material and labour for preparation of wall/ceiling surfaces and applying 1 mm thick cement based external wall care putty on old or new plaster surface complete all as specified and directed. 120 M&L for preparation of newplastered or concrete surfaces and applying two coats of weather proof exterior emulsion paint over a coat of exterior primer of approved shade on walls all as specified & directed by Engineer-in-Charge 121 M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . 122 M & L forproviding and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.50 Ltrs per Sqm of the vertical surfaces of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and directed. Note : Quantity will be measured perimeter of wall x depth of penetration. 123 Labour for disconnecting and taking out old unserviceable underground LT Cable any type alongwith stone patti/ cable cover/bricks/interlocking tiles etc from trenches/ floor/ road /pipe /along poles complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth workrequired for item shall be measured and paid separately under respective items of BOQ. 124 Supply, laying, Jointing and testingin trenches or fixing to wall/pole or passing through pipe and and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including making good to all disturbed surfaces/flooring/tiling/road to match with existing specifications complete all as specified and directed. 125 All per itemd No 124, but size 6 Sqmm 4 core 126 All per itemd No 124, but size 50 Sqmm 3.5 core 127 M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with 80mm GI pipe complete all as specified and directed. 128 Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth for foundations of poles, struts, stays etc. or layingunderground cable etc.in soft/loose soil,& getting out complete all as specified and directed by Engineer-in-Charge. 129 Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge 130 Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. 131 Supply and laying double wall corrugated pipe (DWCP) DWC Pipe dia 77/63, Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating,conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified anddirected by Engr - in charge 132 Supplying, fixing,testing,& commissioning intergal decorative Water proof 9 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type including PCC base with specified size complete all as specified and directed by Engr-in-Charge. 133 S&F Post top lantern Light of 40 Watt capacity made of housing epoxy powder coated pressure die cast aluminium spigot and lid cover with graphite grey finish and clear acrylic cover, IP65 protction,including suitable mounting GI pipe to be fitted into the column / piller with allfitting and wiringand PCC grouting complete all as specified and directed 134 Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge.Note: Rate for making good shall be deemed to be included in above item rate. 135 Taking down unserviceable main switches and MCB distribution boards single phase complete all as spd 136 Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 137 All as per Item No.136 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 138 All as per Item No.136 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed.(socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 139 All as per item No.136 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. 140 S & F modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 141 S & Fmodular Socket outlet multipurpose type 6 Amp 2/3 pin combined, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 142 S & Fmodular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 143 S & F modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 144 M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed. 145 S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. 146 S & F of RCCBs suitable for 240 volts AC supply, double pole40A, 100mA with earth leakage protectionall as specified and directed. 147 S& F plug and socket type DB (Functional unit)20 Amps capacity with provision of single pole 20 amps MCB,plug top and earth plug,grouted flush to walls complete all as specified. 148 S&F Electric bell ding dong complete all as specified. 149 S & Fmodular Bell Push switch, 5Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 150 S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed.. 151 S&F and testing LEDlight fitting 1x20watt 4 feet long including LED tube middle round shape with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. Make :- Bajaj, crompton & Havells 152 S&F for WEE Plus LED bulk head luminaire of capacity 10 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65 complete all as specified and directed by Engr-InCharge 153 S & F aesthetic wall lamp of 15 W having warm white colour complete suitable for wall panelling including connecting up to with 3 core flexible conductor copper of suitable size complete all as specified and directed by Engineer-in Charge, 154 Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. 155 S&F for WEE Plus LED Bldg security light luminaire of capacity 35 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65 complete all as specified and directed by Engr-InCharge :Bajaj, crompton & Havells 156 M&L forsubmain wiring comprisingsingle core ,2 Runs of 10 sqmm nominal cross sectional areamultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete,including provision of 1 x 10 sqmm nominal cross sectional areamultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earthwirecomplete incl taking down old UNSV sub main all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) 157 Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of B class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 158 Supply and fix electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre,BEE 5 Star rated complete with all accessories such as safety valve,thermostate,NRV, connection piece etc all as specified 159 Supply and fixing Air freshener fanPVC body, AC single Phase 230V, 50 Cycle per second, copper winding of sweep size 250mmwith blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. 160 Supply and fixing Exhaustfan metal body body, AC single Phase 230V, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.5 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. 161 Supply and Fixing Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of size 20mm dia all as specified and directed Engr-in-charge. 162 S&F neon strip LED light of warm colour or desired colour with complete driver /connector/adaptor of suitablecap withpower input of DC 2V,6.5W/Mtr consumption and 3000K warm white and 6500K coolday light, 120 LED. 580 lumensper mtr, IP65surge cap upto 3.5KV approx with heat dessipation of length 50 Mtr roll incl all as specified and directed. 163 M&L for ceiling light fitting of skylux LED warm type efficient LED surface square type luminaire & galre free soft illumination of capacity 15 watt LED white/warm coliur complete suitable for roof ceiling including connecting upto with driver 3 core flexible conductor copper of suitable size complete all asspecified anddirectedby Engrin-charge. Make;- Bajaj, Crompton & Havells 164 S&F neon strip/profileLED light of warm colour or desired colour for Modular almirah with auto switch on /off with complete driver /connector/adaptor of suitablecap withpower input of DC 2V,6.5W/Mtr consumption and 3000K warm white and 6500K coolday light, 120 LED. 580 lumensper mtr, IP65surge cap upto 3.5KV approx with heat dessipation with all complete fitting all as specified and directed. 165 S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection Of bldg street lights/fan/garden lights complete all as specified and directed 166 Supply and fix light grade 50mm GI pipe fix complete to Wall , Poles etc with suitable clamp for protection of cable complete all as directed 167 Earthing complete with galvanised steel earth plate electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead 4mm dia GI earth wire by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, (Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner (ii) earthing for Lightning protection is also included in the above item) 168 Supply and fix LT Main control board of CRCA sheet metal board made out of 2.0mm thick and painting with 2 coats with synthetic enemel paint over a coat of red oxide primer including copper bus bar and fixed on/inside wall for fixing arrangement of existing smart meter incl internal connection with suitable size of copper conductor wire, and accessories, locking arrangement with opening handle (size not less than of box 120cmx100cmx35cm and adequate depth for the following equipments,internal wiring and termination of external cables, lugs and glands and conduit as required) including Taking down existing Old Unserviceable main control board comprising of following :- (a) Incoming :- MCCB 63 Amps, 4 Pole,415 Volts, 16 KA-01 No(b) Copper Bus bar 200 Amps for phase and neutral and earth bar(c) Out going MCB double pole 40 Amps - 2 Nos(d) Out going MCB SPN 10 Amps - 1 No

Key Value

Document Fees
INR 500 /-
EMD
INR 38840.0 /-
Tender Value
INR 19.41 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail