Refurbishing And Renovation Work Of Conference Room At Jbnsts- 1 Dismantling & Demolishing Works : Washing and cleaning with soap water and rubbing with oil cloth in all types of floor and dado. 2 Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. 3 Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilutionwith water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 4 Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface 5 Wooden Wall Panelling Works : Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping]. 12 mm thick. 6 Wooden Wall Panelling Works : Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping]. 19 mm thick. 7 Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1mm 8 Supplying fitting, fixing fluted wooded wall panelling over wooden frame srtucture backing. Top finished is PU paint . The panelling is fixed with necessary screews, or others tool . The complete work is done as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. 9 Soft Board Wall Panelling Works : Supplying, fitting and fixing 12 mm thk Soft Board with cloth covering panel works are fixed on existing wooden panel . Soft Board is fixed own frame structure. Size and colour is as per architectural drawing or concern authority. The complete work is done as per direction in Engineer in charge. 10 WoodenWorks ( Cabinet, Partition, Rib, Post etc.) : Wooden Cabinet : Making a wooden Cabinet size2400 x 400x 750 with 19mm boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make. Top finished is done with 1.5mm thick decorative laminate conforming to IS: 2046 : 1995 as per approved make, brand. The Cabinet is fitted and fixed with necessary screews, gum and fitting fixtures . The design of cabinet is as per architectural design . The complete works is done as perEngineer-in-Charge. [The labour, transportation , fitting fixture , eletricity etc. are included in the rate.) 11 Labour Charges for demolishing oflaminate of conference table & all Doors . 12 False Ceiling Works : M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I.intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In ground floor 13 Supply and fixing of existing gypsum ceiling only board Instalation12.5 mm thick tapered edge plain gypsum plaster board conforming to IS 2095 (Part 1):2011.The complete work is done as per Direction-in-Charge. 14 False CeilingBoard : Supply and fixing of false ceiling grid Boardas per site requerment, grid board size 595 x 595 mm,6 mm thick,Density: Typically ranges from 280-320 kg/m3 or 350-420 kg/m3, Edge Profiles: Square Edge: Simple, straight edges, Sound Absorption: NRC (Noise Reduction Coefficient): A measure of how well a material absorbs sound, typically between 0.4 and 0.6 for mineral fiber boards,Surface:surface textures, including fissured, pin perforated, and microperforated, (same material matched as per existing material). The complete work is done as per Direction-in-Charge. 15 False CeilingFrame Structure : Supply and fixing of false ceiling Powder coted GI Tprofile channel as site requerment, galvanizedmild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameterM-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at1200 mm centre to centre along main ‘T’. The system should rest onperiphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (same material matched as per existing material). The complete work is done as per Direction-in-Charge. 16 InternalPainting Works :Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) Ground Floor 17 Applying 2 coats of interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive distemper/Acrylic emulsion paint including scraping and preparing the surface throughly, complete asper manufacturers specification and as per direction of the Engineer-in-charge.Two Coat -Solvent based interior grade Acrylic Primer ,Ground Floor 18 Applying Acrylic Emulsion Paint of approved make and brand on walls and celling sand papering in intermediate coats including putty.Luxary Quality ( Two coats)Ground Floor 19 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:On steel or other metal surface : With super gloss (hi-gloss) - iv) Two coats (with any shade except white) Ground Floor 20 Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Ground Floor 21 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:On timber or plastered surface : With super gloss (hi-gloss) -Two coats (with any shade except white) . Ground Floor 22 Carpet FlooringWorks : Nylon Carpet Tiles . The carpet tile is GUT certified and conforms to the EN 1307 classification. The carpet tile is suitable for intensive use and is therefore suitable for wheelchairs. The carpet thk 6mm. 23 Blind Works : Supplying, fitting & fixing roller blinds(horizontal blinds) of approved brand including all materials & labour complete as per specification & direction of Owner/Architect. 24 Photo Works : Supplying, hanging & fixing various size of photoes frame . The photoes frame are fixed on wooden wall panel. Thecomplete works are done as per specification & direction of Owner/Architect. Size : 600 x 900 - 1 nos, 590 x 510 - 2 nos, 520 x 810 - 2 nos.total - 5 nos complete photo fream . 25 Carving Works : Supplying, fixing a carving scarpture on wooden wall panelling . The scarpture is made with MDF board ( minimum thickness 16mm thick ). The MDF board is laser cut as per design or architectural view .Thecomplete works are done as per specification & direction of Owner/Architect. 26 Furniture : High Back Chairs :For ConferenceSupply, fitting and installation of Executive High Back chair(Overall dimension ofheight - 1100-1300, width - 650 to 800mm, depth - 650-800mm). The seat & back should be made up of 10-13 mm thick hot pressed plywood and moulded PU foam and should be upholstered with synthetic leather.The armrest top should be moulded from polyurethane (PU) and should be height adjustable(6+/-.5 cm) type. The chair should have 360 degre revolving facility, synchronized tilting mechanism,continoous adjustable lumbar support, multi point tilt locking features. The chair should have Pneumatic seat height adjustment facility (6+/-.5 cm),the pedestal should be 5 prong chrome plated pedestal with twin wheel nylon castors. 27 Mid Back Chairs : For ConferanceSupply, fitting and installation of Executive Mid Back chair(Overall dimesnion: Height - 900-1100mm, width & depth - 650-800mm) The seat should be made up of 12 - 14 mm thick hot pressed plywood & moulded PU foam upholstered with fabric. The back should be made up of injection moulded glass filled nylon and upholstered with mesh fabric.The armrest top should be moulded from polyurethane (PU) and should be height adjustable type. The chair should have 360 degre revolving facility, synchronized tilting mechanism,continoous adjustable lumbar support, multi point tilt locking features. The chair should have Pneumatic seat height adjustment facility (6+/-.5 cm),the pedestal should be 5 prong chrome plated pedestal with twin wheel nylon castors. 28 Internal ElectricalWorks ( For Labour Charge ) : Labour Charge for refixing and re-installation of existing fittings and fixtures as per approved drawing & 3 nos new instalation srtip light for ceiling, 5 nos new strip light instalation for wall paneling, The complete work is done as per Direction-in-Charge. 29 LED Display : Supplying, Fittjng ,commission and installation of 1915 x 1100 LED DisplayAll lobour charges, Electricty, Supplying , wire and others necessary tools, screw etc are included in this rate.The complete work is done as per Direction-in-Charge.