Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-08-2025 | Tender Number Correction in BOQ | Other | 20-08-2025 |
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) |
| 2 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0 mtere.) |
| 3 | Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5metre) |
| 4 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means |
| 5 | Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc.complete. (Lift upto 1.5 m). By Mechanical Means |
| 6 | Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262 |
| 7 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263 |
| 8 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 9 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. |
| 10 | Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO ) |
| 11 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete. |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand. |
| 14 | Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc.complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand. |
| 15 | Providing and casting in situ cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant (pan mixer). With natural sand. |
| 16 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/ V.S.I. quality Artificial Sand |
| 17 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand |
| 19 | Providing and laying Cast insitu/ Ready Mix cement concrete in M-25 of trap/ quartzite/ granite/ gneiss metal for R.C.C.Waist slab,and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steelformwork, steelprops,laying/ pumping, compaction, finishing uneven and honey combed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc.complete.(Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag,plastic,tarpaulinetc.) withfully automatic micro processor based PLC with SCADA enabled reversible DrumTypemixer/concrete Batch mix plant(Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 20 | Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 21 | Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete. |
| 22 | Providing and fixing invisible grill mesh made out of SS304 wires fixed to the frame including knotting all the necessary fittings & fixures, scaffolding, etc.complete as directed by engineer in charge |
| 23 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. |
| 24 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. |
| 25 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Completee. |
| 26 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. |
| 27 | Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete |
| 28 | GRC Cladding - Providing and fixing Glass Reinforced Concrete (G.R.C) n accordance to the dimensions mentioned in drawings of proved maked equivalent. While Portland Cement manufactured by ‘JK Cement’ or equivalent , Quartz , Fine Silica Sand, Allkali Resistant Glass Fiber manufactured by ‘Saint Gobain’ or equivalent , super Plasticisers manufactured by BASF or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX’ or equivalent. The material casting should take place in synthetic Rubbe/FRP Mould manufactured by ‘reckli’ or equivalen.The fixing of jali should be ‘Dry fixing’. |
| 29 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. |
| 30 | Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. |
| 31 | Providing internal cement plaster 12 mm thick in a single coat using Ready to use wall plaster to concrete or brick surface in all positions including scaffolding and curing complete. Providing groove at joint of B.B. Masonry and concrete members complete. b) cement ratio 1:3 With Prior Approval of Concerned S.E. |
| 32 | Providing internal cement plaster 20mm thick in a single coat using Ready to use wall plaster to concrete, brick surfaces in all positions including scaffolding and curing. Providing groove at joint of B.B.Masonry and concrete members complete. b) cement mortar 1:3 With Prior Approval of Concerned S.E. etc.complete. |
| 33 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 34 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete. |
| 35 | Providing and fixing precast M-30 Mountable type Kerb Stone having size 450 X 300 X 100 mm without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation complete as specified and directed by Engineering In- charge. |
| 36 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 37 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete. |
| 38 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. |
| 39 | Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. |
| 40 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete |
| 41 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. |
| 42 | Supply & Fixing of Rock / Stone Finished outdoor vitrified flooring Tiles 16 mm thick and required width wide in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete. with prior approval of concerned Superitending Engineer. |
| 43 | Providing and laying artificial stone of 15 millimetre thick for door frame/ dado/ window boxing/ tread / riser etc. fixed jusing chemical adhesive of grade 2 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. |
| 44 | Providing Half-round Moulding ( Full Moulding ) to 18 millimetre to 20 millimetre thick granite stone including fine polishing and cleaning etc. complete |
| 45 | Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. |
| 46 | Providing and fixing imported italian marble slab of 16 to 20mm, thick of approved quality vein and colour/ ivory, with manually filled chemical on the surfacemarble to avoid cracks and erosion while transportation of classic beige/ florotine beige/ diana etc. for flooring in required position laid on bed of 1:4 cement mortar, including cement float, removing Back side crack avoiding net, filling joints with white/ coloured cement slurry, cleaning, curing complete. (Prior approval of sample and brand to be verify by Engineer in charge is necessary before use. |
| 47 | Providing mirror finishing to italian marble stone flooring with minimum 9 times of polishing of different grade of stone wich remove undulation, making even & glossy surface including chemical filling joints of tiles can be used as spacer for tiles material is in powder format with the addingof water converted into the paste after 30min. Coverted into solid elastic material which cannot be removed easily. It has its own shiny colour, the product is made of Weber/ Dr.Fixit which are of approved quality. |
| 48 | Providing Rounded Moulding to Italian Marble stone edges as per approved design including cutting, grinding, moulding, polishing etc. with all material, machinery etc. Complete. |
| 49 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 50 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. |
| 51 | Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. |
| 52 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC‘s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. |
| 53 | Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc |
| 54 | Providing & applying epoxy grout for tile spacer joints complete as directed by engineer in charge. |
| 55 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box |
| 56 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. |
| 57 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) |
| 58 | Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. |
| 59 | Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 60 | Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 61 | Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 62 | Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 63 | Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 64 | Providing and fixing on walls/ceiling/floor 50 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 65 | Providing and laying in trenches 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 66 | Providing and laying in trenches 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 67 | Providing and laying in trenches 50 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 68 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 69 | Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 70 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 71 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 72 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) |
| 73 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete |
| 74 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 75 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 76 | Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. |
| 77 | Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete. |
| 78 | Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. |
| 79 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. |
| 80 | Providing and fixing C.P. sink cock with raised J\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\" |
| 81 | Providing & applying damp guard to wall for prevent the fungus, algae and dampness etc. including preparaing the old damaged surface by scrapping to remove foreign matter and scaffolding if necessary etc. complete. |
| 82 | Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete. |
| 83 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. |
| 84 | Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floormounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. |
| 85 | Providing and fixing Slim Single Piece Concealed Cistern Body (Front or Top Actuation) with Floor Mounting Frame, Installation Kit and “S-Type” Drain Pipe Connection Set for Wall Hung WC with Flush Control Plate with pipes complete as directed by engineer in charge complete |
| 86 | Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. |
| 87 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 88 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 300 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 89 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete. |
| 90 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. |
| 91 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. |
| 92 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. |
| 93 | Providing, laying and fixing in position cladding with stone of required height, length, thickness of 50mm -230 mm on wall with approved stone material, chemical material carting, dressing, fitting etc. complete as per detailed drawing and as directed by Engineer in Charge |
| 94 | Providing, laying and fixing in position flooring with stone of required height, length, thickness of 50mm -230 mm with approved stone material, chemical material carting, dressing, fitting etc. complete as per detailed drawing and as directed by Engineer in Charge |
| 95 | Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. |
| 96 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters |
| 97 | Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) |
| 98 | Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 Kilogram) |
| 99 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (160 Kilogram) |
| 100 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 Kilogram) |
| 101 | Providing, constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. |
| 102 | Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective xcavated material etc. complete. |
| 103 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 104 | Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 105 | Providing and fixing PVC-Sch 80 water supply pipes as per IS 1785 with with all fittings like tees, bends, elbows, reducers, unions, nipples etc./ including concealing the pipes in walls or under floors wherever necessary, including making chases in the walls, fixing in the wall with clamps and making good the wall surface etc. complete hydraulic testing after laying the pipes as specified including making holes in the walls or floors as required and redoing the same.(working pressure - not less than 2.5 mPa @ 23 Deg C Pipes shall be joined using solvent welded fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe / GI)75 mm Dia |
| 106 | Supplying and erecting 1 phase 230V,50Hz submersible pump having discharge 130/475 LPM,Head 21/9 m & delivery pipe of necessary diameter erected with necessary H type clamps as per specification no. WP-OSP. Hp not more than 2 HP a) 10 Per Cum per hr @ 15 m head |
| 107 | Providing & fixing mural with art work in Fibre Reinforced Plastic material with 25 mm to 300 mm minimum embossed made up of rooflight resin and fibre glass including clay modelling, moulding & casting as per design & drawing etc. complete. |
| 108 | Providing & fixing Acrylic UV solid surface sheet of approved make, colur and finishe with fixing on existing base surface with adhesive and finshing with buffing to make surface smooth, corners round etc as directed by engineer incharge. |
| 109 | Providing ,fixing & supplying 4 mm thick designer palliate sheet of approved make for fixing as directed by engineer incharge. |
| 110 | Providing ,fixing & supplying ply 19 mm thick & fixing as directed by engineer incharge. |
| 111 | Providing ,fixing & supplying ply 12 mm thick & fixing as directed by engineer incharge. |
| 112 | Providing ,fixing & supplying ply 8 mm thick & fixing as directed by engineer incharge. |
| 113 | Providing ,fixing & supplying 1 mm thick color laminate of premium make for fixing as directed by engineer incharge. |
| 114 | GARDEN SOIL:- Supplying on site garden soil well sieved 90% to pass through I.S. sieve of 10mm size free from stones rubbish like dried grass roots and other such materials.The soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured box. (Farma) (Item includes royalty charges, Transporting, loading- unloading etc.)lead charges for 20 k.m. is considered (80% Local soil + 20% red soil) |
| 115 | FARM YARD MANURE: Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The colur of the manure generally be black. The manure will be measured by measuring box. (Farma) (Item includes Transporting, loading unloading etc.) lead charges for 20 k.m. is considered |
| 116 | Preparing Lawn ( 20 cms Depth) Excavating the ground to required depth of 20 cms . Removing & conveying unwanted stuff to required distance as directed. Filling fresh garden soil/silt & manure in Excavated area in 3:1 proportion to a height of 20 cms. Mixing garden soil and manure thoroughly well leveling watering on previous night. Planting required variety of lawn grass as directed and maintain till well established by watering weeding clipping rolling etc complete. |
| 117 | Labour charges for Filling fresh garden soil/ silt & manure in excavated area including lead up to a distance of 50 Per Metrs |
| 118 | Labour charges for Mixing garden soil/ silt & manure thoroughly well, watering previous night. Planting required Plant species, lawn grass as directed etc. complete. |
| 119 | Unskilled Labour. |
| 120 | Semiskilled Labour (Mali) |
| 121 | Preparing Edging or Border :- Excavated the ground to a required depth of 20 cms.in the required area., removing and conveying unwanted stuff,rubbish to the required distance as directed. Filling the excavated part with fresh soil and manure in 3:1 proportion to a required height of 20 cms. Mixing,leveling, watering the same. Planting rooted edging / border plants at distance of 20 cms. apart by watering weeding, stirring of soil replacing casualties,prunning if necessary etc.complete. |
| 122 | Planting clipped Hedge:- Excavating the ground to a required depth of 30 cms,removing and conveying unwanted stuff to a required distance as directed, Filling fresh garden soil & manure in excavated area in 3:1 proportion to a required height of 30cms. Mixing garden soil and manure thoroughly well, levelling , watering previous night.Planting hedge plants of required species in two rows. Distance between two rows & between two plants will be 25 cms.maintaining till well established by watering, weeding stirring the soil and clipping if necessary etc.complete. |
| 123 | Preparing flower Bed:- Excavating the ground to the required depth of 30cms. Removing and conveying unwanted stuff to a required distance as directed, Filling fresh garden soil & manure in excavated area in 3:1 proportion to a required height of 30cms. Mixing garden soil and manure thoroughly well, levelling , watering , on previous night. Planting seedlings of required annuals 25cms. apart maintaining till well established by watering, weeding stirring replacing of casualties etc. complete. |
| 124 | Planting large flowering/ shady trees:- (Minimum Height to 1 Meter.) Digging pit with size 0.9mx0.9mx0.9m, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30m.and remaining height of 0.60m.with fresh garden soil & manure in 3:1 proportion. Mixing soil & manure thoroughly well, levelling, as directed, watering previous night, planting one to two year old healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil replacing of casualties etc,complete. |
| 125 | Planting large flowering/ shady trees:- (Minimum Height to 2 Meter.) Digging pit with size 0.9mx0.9mx0.9m, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30m.and remaining height of 0.60m.with fresh garden soil & manure in 3:1 proportion. Mixing soil & manure thoroughly well, levelling, as directed, watering previous night, planting one to two year old healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil replacing of casualties etc,complete. |
| 126 | Planting small and medium size ornamental/ Flowering plant:- Digging pit with size 0.6m x 0.6mx 0.6m, removing conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil & farm yard manure upto a height of 0.60m. In 3:1 proportion. Mixing soil and manure thoroughly well, levelling , watering on previous night. Planting one to two year old healthy plant saplings as per specification. Maintaining till well established by watering, stirring, of soil and manure, replacing casualties, etc. complete. |
| 127 | Preparing ground covers:- Excavating the ground to a required depth of 20cms. Removing & conveying unwanted stuff, rubbish to the required distance as directed. Filling the Excavated area with fresh garden soil & F.Y. Manure in 3:1 proportion to a height of 20 cms. Mixing, levelling watering the same previous night. Planting suitable ground covers as directed in staggring pattern, distance between two rows 25 cms., watering & maintaining till well established. |
| 128 | Providing and Laying Artificial Grass Truff (Landscape) 25 mm as per Specfication Greenturf‐25mm Landscape , Pile height 25mm ,Tuft Gauge 3/8\",Material/ Dtex PE & PE9, 13200, Stitch rate 15/10 cm, backing double,Colur‐Strainght yarn emerald green and oilve b‐icolour/Curl yarn Dark green/Brown, Density: 1575 Stitches/m2 etc.complete |
| 129 | Providing of grasscrete paver of thickness 80 mm deep laid on a consolidated sub-base with a 10/20mm binding layer of 50mmthickcompactedbed of fine aggregate (naturalsand/crushedsandVSIgradefinelywashed etc.) compactingand proper embedding into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratorycompactionbyusingplatevibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cuttingasperrequiredsize andpattern, finishingand sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturerspsecifications & direction of Engineer-in-Charge. |
| 130 | Providing, Fixing, Testing & Commissioning of UPVC pipe of ISI standard, Jain/ Supreme / FiNumberlex make with all necessary fittings & labours. a) 75 mm suitable for working pressure 10 kg/sq.cm |
| 131 | Providing, Fixing, Testing & Commissioning of UPVC pipe of ISI standard, Jain/ Supreme / FiNumberlex make with all necessary fittings & labours. a) 50 mm suitable for working pressure 6 kg/sq.cm |
| 132 | Providing, Fixing, Testing & Commissioning of UPVC pipe of ISI standard, Jain/ Supreme / FiNumberlex make with all necessary fittings & labours. a) 40 mm suitable for working pressure 6 kg/sq.cm |
| 133 | Providing, Fixing, Testing & Commissioning of Pop-up Gear Sprinkler with Numberzzle of radius 8-12 M @ 2 to 3 bar, Q- 0.12 to 0.18 lps, Rainbird/Toro/Hunter or equivalent with Check valve and swing joint including fittings, all labours. |
| 134 | Providing, Fixing, Testing & Commissioning of 16mm 2.0 to 2.5 lph @ 0.40 cm pressure compensating inline dripline of ISI mark, including fittings, all labours. |
| 135 | Providing, Fixing, Testing & Commissioning of 16mm Drip Tubing of ISI mark, including fittings, all labours. |
| 136 | Providing, Fixing, Testing & Commissioning of 3/4\" Quick Coupling Valve on 75/63 mm pipe solid brass construction Harit make or Equi with MS service saddle and GI pipe riser and all necessary fittings, including all labours. |
| 137 | Providing, Fixing, Testing & Commissioning of QCV Key with hose swivel arrangement of solid brass construction Rainbird/Equi with all necessary fittings, including all labours. |
| 138 | Providing, Fixing, Testing & Commissioning of 2\" PVC Isolation Valve/Master Valve of Kirloskar/Equi supported by concrete thrust block, including all labours, |
| 139 | Providing, Fixing, Testing & Commissioning of 1.5\" PVC Isolation Valve/Master Valve of Kirloskar/Equi supported by concrete thrust block, including all labours, |
| 140 | Providing, Fixing, Testing & Commissioning of 63 mm PVC Isolation Valve of Kirloskar/Equi supported by concrete thrust block, including all labours, |
| 141 | Providing, Fixing, Testing & Commissioning of 50 mm PVC flush valve, including all labours, all taxes if any |
| 142 | Providing, Fixing, Testing & Commissioning of double acting Air Release Valve assembly of 1\" size with Ioslation valve and necessary fittings, including all labours, all taxes if any except WCT. |
| 143 | Supply, laying of Sand layer 75 mm above and below the pipe for pipe line laying under paved area, including all labours, all taxes if . |
| 144 | Providing & applying lacquer coat to stone or masonary as directed by engineer in charge. |
| 145 | Providing, Fixing, Testing & Commissioning of Filtration Unit consisting of Disc Filter for a filtering capacity of designed flow (25 m3/hr) with Back flush Unit conforming to IS specifications complete with all fittings, including all labours, all taxes if any. |
| 146 | Providing, Fixing, Testing & Commissioning of Filtration Unit consisting of Sand Filter for a filtering capacity of designed flow with semi automatic Back flush Unit conforming to IS specifications complete with all fittings, including all labours, all. |
| 147 | Providing, Fixing, Testing & Commissioning of C.I Numbern- Return Valve 2\" dia of Kirloskar / Equivalent make, including fitting, all labours, all taxes if any. |
| 148 | Providing, Fixing, Testing & Commissioning of Water - meter for a designed flow capacity of Dashmesh / Equi, including all labours, all taxes if any. |
| 149 | Providing & Fixing of PVC pipes of with all necessary components like fittings for pathway crossing including all excavation, cutting if required, concrete encasement and making good of damaged works. (b) PVC 90 mm X 10 kg/cm2 |
| 150 | Providing, Fixing, Testing & Commissioning of Pressure relife Valve 1.5\" with including fittings, all labours, all taxes if any. Rainbird/TORO/Hunter equivalent |
| 151 | Providing and fixing 10 mm polycarbonate multiwall Ultra Voilet protected sheet for roofing over fabricated steel structure as per detailed design, perforated CRC sheet along perimeter, including fixing the polycarbonate sheet with alluminium angle and flat anodised and dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour and safety grill of 16 mm dia. M.S. Bars fixed with help of M.S. Flats and angles over the opening complete including all scaffolding etc. as required. (Only actual area of polycarborate sheets to be considered for measurements). |
| 152 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250gms per Per Square Metre area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete. |
| 153 | Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80 MM thick in M-40 grade of approved size and shape for City streets, small/ medium market roads, low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658 :2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of naturals and /crushed sand of 50mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete. |
| 154 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 155 | Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. |
| 156 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 157 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 158 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 159 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 160 | Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stacking the materials as directed etc. complete. |
| 161 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete |
| 162 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 163 | Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. |
| 164 | PICC filling for Honey combing area at concrete surface:-Providing and applying Poly Ironite Ceramic Cementitious (PICC) material of Self cureing ,High Abrasion resistant , Non shrink ,High strength,UV resistant, repair mortar coating on Kelox water missble epoxy of concrete surface fill the honey combing area etc. on tacky primer coat upto 10 mm thickness or as per the surface conditions including Cleaning the concrete surface of bridge by grinding the surface by grinder machine with wire brush /diamond wheel, removing existing loose particles etc. by using grinder, wire brush,breaker machine, water jet(using other mechanical / manual means) also removing of algae fungi by special chemical of clonon. etc.complete with all leads and lifts, Material, Machinery, Labour, Scaffolding etc. complete as per specification and as directed by engineer-in-charge. |
| 165 | Provinding and errecting 1.5m high fix knot fencing having upto 17 rows of 2.5 mm high tensile galvanised wire having vaiable spacing fixed on M.S. angle 50 x 50 x 5 mm embedded in c c block of 1:4:8 of size 450 x 450 upto 6 m spacing of pole having end wire, tension crimp and end wrap including pulling high tensile wire with puller including finishing and coat of oil painting to M.S. angle etc. complete as directed by enginner in charge. |
| 166 | Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete. |
| 167 | Providing & fixing study table made up of plywood and finished with laminate, fevicol etc as directed by engineer in chage. |
| 168 | Providing and fixing decorative stealth series ivory gold or chromium plated Overhead Shower of approved jaguar or equivalent make with flang, necessary angular connecting rod, union nut, washers, taplon tape etc. complete. |
| 169 | Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC/ cementitious surface for terrace waterproofing on B.B. Coba /R.C.C, after application of TP-42 Primer on perfectly clean surface (free from loose dust and foreign matter ) application of 1st coat of Polydee-LM @ 700 gms/One Square Metre and applying 2 nd coat of Polydee-LM @ 700 gms/One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplastfibre @ 125gms / One Square Metre to be paid in separate item. )etc. complete. |
| 170 | Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. |
| 171 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. |
| 172 | Providing and fixing frame work of galvanised iron for suspended false ceiling which includes galvanised iron perimeter channels of size 27 mm and 0.5 mm thick having one flange of 20 mm and another of 30 mm along with perimeter of the ceiling, fixing in brick wall / partition with the help of rawal plugs and screws, suspending galvenised iron intermediate channels of size 45 mm and 0.9 mm thick with two flanges of 15 mm each from the soffit at 1200 mm centers with steel galvanised iron hanger of width 25 mm x 0.5 mm fasteners, ceiling section of 0.5 mm thickness having curved wedge of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 450 mm centers, 12.5 mm dry walls screws at 230 mm centers; fixing screws mechanically either with screw driver or drilling machine with suitable attachment etc. complete. |
| 173 | Providing and fixing false ceiling of 10 to 12 mm thick decorative boards of fibrous plaster of paris including scaffolding if necessary all architectural work like mouldings, cornices, coves, domes, cups as per detailed drawings and three coats of spray painting to boards etc. complete. (excluding frame work, runners and mild steel suspenders). |
| 174 | Providing & Applying Indian Marine Calelalite Treatment to Plaster of Paris false ceilingto make waterrepellent surface complete as directed by engineer in charge. |
| 175 | Sliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge. |
| 176 | Providing and fixing in position Panelling for Door and windows jam\"s made up of 19mm thick waterproof plywood of approved quality make (Century, Commander, Biz,etc.) for sides and exposed parts are finished applied with formica of approved shade sticked with approved quality glue of Fevicol make and abrotape including nails, screws,complete as per detailed drawings and as directed by Engineer in Charge |
| 177 | Providing and fixing solid core flush door single/ double leaf 35mm thick decorative type exterior grade as per detail drawing with approved face laminate 1 mm thick on both faces as approved and as directed with all necessary lipping and with aldrop (10” suare type heavy duty handles with 12” heavy duty latch, 12” tower bolt, 125mm heavy duty hinges, heavy duty stoppers with necessary SS screws, nuts, bolts, oil paint to lipping etc complete as directed by Engineer in charge |
| 178 | Supplying and fixing in position Upvc section three track sliding window with extra mosquito net /UPVC Door of yash polyprofiles or equivalent make, outer frame made from section overall size 80mmx45mm, with shutter sections made out of 19mm x 40mm size, with 5mm selected quality plain sheet glass fixed with new neoprene gasket shutters to be provided with nylon encased stainless steel rollers , necessary touch lock, and handles etc. complete (as per architect\"s drawing)as directed by engineer incharge |
| 179 | Providing and fixing in position Entrance Main Door Shutter made up of 3mm to 19mm thick plywood of approved quality make (Century, Commander, Biz, etc.) for sides and exposed parts are finished applied with 4mm plywood base Original wooden plank Palliate Sheet of approved shade sticked withapproved quality glue of Fevicol make and abrotape including Ammoium Tiocyanate Distillate Polish to all the PalliteSheet Exposed surfaces wtith PU Fnish and necessaary fittings nails, screws, the shutter frame having 8mm glass make of (Modiguard, saint Gobain, etc.) complete as per detailed drawings and as directed by Engineer in Charge. |
| 180 | Providing and fixing best quality 950 high GRC railing as per drawing in 304 grade with baluster which made out of 50 mm diameter and 16 gauge pipe fitted firmly by means of resin anchors and concealed cover. Handrail will be of 50 mm diameter and 16 gauge pipe having 12 mm daimeter rods passing through 16 mm diameter bush will be used as infill baluster position at time of installation will be changed depending upon the site condition and siuation and as directed of Engineer in charge |
| 181 | Providing and fixing Wooden Photo frames on wall including screwing, Prints on imported make canvas with matt finishing having wooden moulding to the sides of frames minium 35 mm thick with glossy / matt 4 mm Glass and artistic finish photo picture chosen by Engineer in Charge |
| 182 | Providing and Fixing Executive High Back Revolving Chair having very Soft cushioning with recron and highest quality leather fabric which handrest with wooden and melamine polished to give comfort set at proper place etc complete as directed by Engineer in Charge |
| 183 | Providing and fixing in position Reception / meeting hall table made up of 3mm to 19 mm thick waterproof plywood make ( Century, Commander, Biz etc) for sides and table top and internal surfaces finished with Formica approved make as directed by the Engineer in charge including decorative mouilding in required position drawer slider ( decorative channel make of solo, polo and such other company) knob, handles required multipurpose lock complete as per detailed drawings and as directed.) |
| 184 | Providing and laying vitrified tiles having size 60 cm x 120 cm and 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete |
| 185 | Providing and laying vitrified stone effect finish tiles having size 60 cm x 120 cm and 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. |
| 186 | Providing and fixing toughned glass partitions from 8mm to 12mm thick with all necessary spider/ clamp/ profile fittings/ hinges/ stainless steel fixtures & pivot arrangement etc.complete. Spec. no. as directed by Engineer in charge. |
| 187 | Dismantling Cement or lime plaster including disposing off spoils as directed with all lifts & leads etc. complete |
| 188 | Dismantling Existing False Ceiling & stacking the material as directed with all leads & lifts . |
| 189 | Providing & fixing mosaic tile for swimming pool wall & floor in designer pattern including adhesive, cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete. with prior approval of concerned Superitending Engineer. |
| 190 | Providing & Erecting Double Bed of size 1.8m x 2.1m with head boardas per drawing. Bed side corners should be made round. |
| 191 | Providing & Erecting Bed Side table of size 0.45 x 0.30 x 0.45m as per drawing |
| 192 | Providing & Erecting TV Unit of size 0.90 x 0.45 x 0.75m as per drawing |
| 193 | Providing & Erecting Wardrobeof size 1.00 x 0.5 x 2.10 m as per drawing |
| 194 | Providing & Erecting Center Table of size 0.80 x0.50 x 0.45m as per drawing |
| 195 | Providing & Erecting Dressing Table of size 0.90 x 0.30 x 0.75m as per drawing |
| 196 | Providing & Erecting Corner Table of size 0.50 x0.50 x 0.45m as per drawing |
| 197 | Providing & Erecting Single Seater Sofa of size 0.60 x 0.60 m as per drawing |
| 198 | Providing & Erecting Double Seater Sofa of size 1.20 x 0.60 m as per drawing |
| 199 | Providing & Erecting Three Seater Sofa of size 1.80 x 0.60 m as per drawing |
| 200 | Providing & installing Smart Ortho Mattress with 02 nos of pillows of Sleepwell or equivalent make made out of Ortho Relief Foam, Medium Firmness, Dimensions appropriate for double bed, etc. complete as directed by Engineer in Charge |
| 201 | Providing & installing Smart Ortho Mattress with 01 no of pillows of Sleepwell or equivalent make made out of Ortho Relief Foam, Medium Firmness, Dimensions appropriate for single bed, etc.complete as directed by Engineer in Charge. |
| 202 | Providing and supplying Luxary mattress of sleepwell or equivalent mattress (Size 1829 x 1829 x 140mm) with pillows (2 Nos), Bed sheet and Sleepwell Solace blanket (1 No) etc. complete. |
| 203 | Providing and supplying Luxary mattress of Sleepwell or equivalent (Size 900 x 1829 x 140mm) with pillows (1 Nos), Bed sheet and Sleepwell Solace blanket (1 No) etc. complete. |
| 204 | Providing and fixing 19 mm thick Plain Bison Panel/Cement sheet including Stainelss steel olts, nuts and scaffolding etc. complete. . Spec. No.: As directed by Engineer-In- Charge |
| 205 | Providing and fixing 12 mm thick Plain Bison Panel/Cement sheet including Stainelss steel olts, nuts and scaffolding etc. complete. . Spec. No.: As directed by Engineer-In- Charge |
| 206 | Providing and fixing shingles on Roof of size 17 x 40 inch to 13.1/4\" to 39.1/8\" of asphalt. The material are resistance against fire and atmospheric aggressions and are developed using high quality material and cutting edge technology. |
| 207 | Supplying and fixing Exterior Grade Wooden Flooring/cladding (Wood Plastic Composite) size of (L 2200mm, W-135mm, T -24 mm) for Exterior Grade use, with all Necessary fittings and accesories. including Taxes, Transportation at Site, Etc Complete. Colour/ Texture as Selected by Engineer-in-Charge |
| 208 | Chemical waterproofing on terrace / bathroom by cleaning the surface and made free of dirt, foreign particles via mechanical grinding using appropriate equipment, identifying and sealing the Surface Cracks and Concrete Slab Panel Joints & penetrations, Cutting and opening the Cold Joints of the slab with suitable cutter machine in \"v\" groove and filling with moisture triggered single component polyurethane based Sealant. Providing and applying waterproofing chemical membrane on horizontal and vertical face over primed surface using roof surfaces including parapet walls upto spring bottom, including pedestals, upstands and all utilities available at roof. Waterproofing membrane should be applied post application of Primer. Polymer modified mortar should be used for surface preparation for damaged area as per requirement. Fibre mesh should be applied on joints as per requirement as directed by engineer in charge. |
| 209 | Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 210 | Providing & fixing Sewage treatment Plant of desired sewage discharge after treatment as per standard having screen chamber, diffuser, air blower, raw sewage transfer pump, Sand Filter, Carbon Filter, Sludge recirculation pump, filter feed pump, interconnecting piping & valves including commissioning etc complete as directed by engineer in charge. |
| 211 | Supplying and fixing of 6mm thick Exterior Compact Laminate or High Pressure Laminate of approved colour by approving authority with UV resistant Decorative colour paper on both side typically made out of multiple layers of craft papers and then impregnated with thermosetting phenolic resins, on top of it melamine treated barrier paper and decorative paper and wear layer on both the sides saturated with melamine resins and then covered with UV resistant acrylic resin layer which makes it extremely durable and weather resistant compressed together on extremely high pressure and hardened with electron beam curing to get the total desired thickness of 6mm matching European standard specification as per EN 438 -part 6, protected with 60 Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 mm X 5 mm X 3 mm powder coated aluminium box section to be spaced horizontally and vertically in 600mm X 600mm grid and fixed to building structure as per design through 50mmX50mmX mm 5 mm MS angle bracket prefixed to masonry slab or columns with Hilti make anchor fastener along with all related hardware and fixtures. The panel should then be fixed on the Aluminium section with the help of pure polyester exterior grade colour coating rivets as per architectural drawings or as directed by Engineer-in-charge. Each panel should be riveted on substructure maintaining a gap of 6mm on all the sides between each Panel for Air circulation and expansion and contraction as per installation specifications provided by the manufacturer. The cost shall include all expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer-in-charge. |
| 212 | Supplying of Outdoor Table & four Chair in as directed By Engineer Incharge |
| 213 | Providing & fixing Animal Meri Go Round - (Area - 1.5M dia ) safe play area 2.5Mdia item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 214 | Providing & fixing Multi seater See Saw - (Area 3.0MX0.5M) safe play area - 4.0MX1.5M item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 215 | Providing & fixing Crestal Maze- (Area - 2.4Mx2.4M) Ht 3.4M, safe play rea 2.5MX2.5M item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 216 | Providing & fixing 12 feet size Trampoline with Basketball Hoop having product dimensions - Height: 27 cm, Depth: 149 cm, including Easily Detachable Basketball Board, Foam Covered Basketball Ring To Prevent Any Injury While Jumping, Ladder, Long Poles For increasing Structural Integrity item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 217 | Providing & fixing Multiactivity play set (sliding, climbing, balancing, exploring & swinging) with Safe Play Area (m) 8.5 X 7.5 Total Area Required (sq m) 63.75 Platform Height (ft) 5 ft MATERIAL Galvanized Steel, Polyethlyene, Pure Polyester, Nylon, FIbre Glass item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 218 | Providing & fixing Standard Bench - Area (0.6MX1.8M) Capicity 4 Adults item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 219 | Providing & fixing Spring Rider Jumbo with (Area - 0.40MX0.75M), (Safe Area 1.4MX1.75M) item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 220 | Providing & fixing Single Swing with belt assly - (Area -1.5MX2.5M) platform Ht 2.4M, (Safe play Area - 2.5MX3.5M) item consists of ISI marked structure. (Prior approval of sample and brand to be verifiy by Engineer in charge is necessary before use.) |
| 221 | Carting away the debris from the site to the appropriate dumping ground outside the Municipal Limits upto 15Kms, etc.complete as directed by engineer in charge |
| 222 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 223 | Providing & Fixing Designer 10mm to 30mm thick artificial Stamping such as natural Stone/Bricks/Wooden surface having UV resistance colours with water repellent qualities,fire resistance,one piece application with Number joints,light weight material resist on hot and cold climate as per cladding design ,providing onplaster surface,Filling joint with colour Adhesive & making Surface treatment by glossy/matt lacrecoat,smoothning,and finishing it on proper level as directed by engineer in charge. |
| 224 | Providing making and fixing TV panelling for the walls of 450MM width made up of 19mm ply and teak wood with approved shade laminate on all external surfaces & white laminate Internally, Including provision for intermediate shelves and all the exposed edges to be finished with C edge banding. Rate to include of necessary Numbers of locks, auto closing hinges for shutter, approved handles, magnetic ball-catch, Tower Bolt etc. complete as directed by engineer-incharge. |
| 225 | Providing & fixing dining table with artificial top of size 1.50 x 0.90 x 0.75m ht in required position as directed by Engineer in charge complete as directed by engineer-in charge. |
| 226 | Providing making and fixing dining chair Size of 0.45 x 0.50 x 0.90 m ht with Teak Wood main frame and top 19mm thick Ply finished approved shade Laminate on all external surfaces, and all the exposed edges to be finished with C edge banding. Rate to include of necessary Numbers of Tower Bolt etc. complete as directed ( as directed by Engineer-in Charge) |
| 227 | Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m at 60 cms center center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete. |
| 228 | Providing and fixing fabricated Designer Cast Iron Railing made up of top 50x25x3.2mm thick Rectangular box section and below 25x25x3.2mm thick square hollow section for top and bottom, supported by 12x12mm square bar @ 120 c/c. Post should be of size 72x72x4mm thick box section @ 2400mm c/c., with desiner cast jali / bar fixed as per design, including applying oil paint / antique finish complete as per designed under the direction of engineer in charge. |
| 229 | Supplying double duvet made from a unique soft and buttery slow-release fiber filling encased in specially coated premium fabrics as directed bu Engineer in Charge. |
| 230 | Supplying duvet cover of qood quality made from 100% cotton fabrics & cotton satin sabrics with customized patterns as per required sizes as directed by Engineer in charge. |
| 231 | Basic Filtration System Filter : Totally anti-corrosive manufactured with high quality glass fiber and polyster resins, pressure gauge, air release valve, lid at top, lateral holder and PP disc stainers for maximum efficiency, drain valve, filter media etc. complete with 75mm MPV. Filter dia.- 1200mm, Flow rate 8Cum/hr.Make:- Crystal Engineering Working Pressure 3.5 Kg/Sq.cm. |
| 232 | Basic Filtration System - Filter Media |
| 233 | Basic Filtration System -Hair and lint Strainer Inlet and out let connections, Totally anti-corrosive manufactured with high quality glass fiber and polyester resign, with transparent glass lid at top, PP basket etc. complete.Make :- Diaflow a) 75mm dia Inlet and Outlet |
| 234 | Pump Supply & Installation of Horizontal monoblock circulating pumps with body in cast iron and prefilter, impeller in GM, shaft in stainless steel. capable of delivering 48 cum/hr. at 10-12 meters.Head, 1450 RPM. 3 phase 415/420 volts 3 H.P. Make : Kirlosker Modal No KDS318++ One Working and OneStandby. |
| 235 | Plumbing All 10kg. Per cm sq. ISI mark PVC pipe and fittings MakePrince / Finolex / equivalent 75mm Pipe |
| 236 | Plumbing All 10kg. Per cm sq. ISI mark PVC pipe and fittings MakePrince / Finolex / equivalent - 63mm Pipe |
| 237 | 75mm Butterfly Valve |
| 238 | 75 mm Foot Valve |
| 239 | 75 mm Non-Return Valve |
| 240 | Pool Accessories -Hand rails Made in SS 304 with 38mm OD, 16 gauge pipe with 3\" support height and 3mm thick glange fixed with SS Cotch Screw.Make :- Cryster Engineering |
| 241 | Pool Accessories-Overflow Gratings Suitable for 12\" wide over flow gutter modulartype available in different colors made in PP Plastic Make :- CrysterEngineering |
| 242 | Pool Accessories - Wall Inlet Regulable type floor inlets mead in ABS plastic having max. Flow 10000 Make :- Cryster Engineering |
| 243 | Pool Accessories - Pool Drain |
| 244 | Pool Ladders MADE in SS 304 with 38 mm OD ,16 gauge hand rails and anti skid SS trades fitted with nut bolts, 4” dia. flange for fixing on walls. Height 30”. Step size - 21” length and 3”/4” widthMake :- Cryster Engineering - 4 Steps |
| 245 | Maintenance Equipements - Suction Trolley Made in SS 304 wirh FRP Platform mounted with self priming pump, starter and cable etc. suitable to adopt suction hose for maintenance and cleaning purpose. Make :- Cryster Engineering |
| 246 | Maintenance Equipements Leaf Rack |
| 247 | Maintenance Equipements Poo brush curved type |
| 248 | Maintenance Equipements Suction head maid in SS with Rope wheels and brush |
| 249 | Maintenance Equipements - Aluminum Telescopic pole 5m long |
| 250 | Maintenance Equipements - Suction hose 30m long |
| 251 | Maintenance Equipements -2 in 1 pH & CL testing kit |
| 252 | Maintenance Equipements- Electrical and cabling |
| 253 | Electrical Control Panel Supply & Installation of Electrical fittings – Per No Motor control center to house all switch gear and components such as mains isolator, motor starters, ammeters, switches, fuses, single phase preventor for pumps. Required MCC for single phase if required, etc. internally wired and shall be completed in all respects including all components supplying, laying power & control cabling in the field of the battery limits |
| 254 | Dosing System for Chlorine & PH with Container Constant Flow membrane Dosing System chlorine Dosing to have residual chlorine presence in the Swimming Pool and act as a backup for Ozoniser. 15lph @5 bar.Make:- Pentair or Equivalent |
| 255 | Ozonisation System Ozonator with concentrator to get the necessary disinfection to kill germs, bacteria and prevent algal growth to get 2 ppm ozone Booster Pump and Venturi system sutable for 500000 lit. Pool capacity. Make :- Elteck |
| 256 | Life Saving Equipemnts - Life Buoy |
| 257 | Life Saving Equipemnts - Life Saving Loop |
| 258 | Life Saving Equipemnts - Loop Holder Pipe |
| 259 | Life Saving Equipemnts - Life Guard Chairs |
| 260 | Life Saving Equipemnts - Oxygen Cylinder with mask |
| 261 | Life Saving Equipemnts - Stretcher |
| 262 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/Wall and all type of Interior, ExteriorCompound wall and Gate etc. of cladding processedstonewithmaterialofProcessedclay,Woodenchips,Silicasand,Cement, GFRCadmixtures,Colourpigments,Fiberuptothickof230mm/25mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) |
| 263 | Providing & fixing facia patti made up of 12mm thk bison board having height of 150 mm. Laser cut design should be done to facia patti as per architect and approved by enginner in charge. |
| 264 | Providing, fixing, erecting, commissioning and handing over of the Pine wood Pre-fabricated Gazebo of size 3 meter x 3 meter area with height of structure (ridge level) 3.38 meter above ground level and height of floor deck is 0.45 meter above ground with following specifications and as per the detailed drawings: Structure: - Structure of the Gazebo should be structurally stable skeleton for walls , roofing etc. made up of graded & treated Pine wood as per detailed design, drawing & schedule including cutting, binding, scaffolding & supporting as directed by engineer in charge .Design of the structure, detailed design drawings and shop drawings to be provided by the vendor. All design, detailed design drawings and shop drawings will be finally confirmed after the detailed structural scrutiny. Flooring: pinewood for decking and steps; including laying with 38 millimetre x 75 millimetre planks covered with 19 millimetre Marine grade water proof Plywood.. Wooden Finishes: - Finishing of all wooden surfaces in linseed oil coatingin two coats as directed by engineer in charge. |
| 265 | Providing & fixing luxury resort tent of overall size 51 Sqm & carpet area of 34 Sqm made of following specifications - Roof made of four layers waterproof with flame retardant according to BIS code, Top layer in heavy duty shade fly treated with ultraviolet in 350 to 420 Gsm, Senod layer in PVC rain fly in 620 Gsm, 3rd Layer in polyster ripstop canvas for tent body in 410 Gsm, 4th layer in polyster fabric for inner linings in 200 Gsm. Tent frrames are made up of mild steel squre and round tubes. Side walls are made up of 50 mm thk puf panel with ons side PPGI sheet and another side finished with real wooden panel / canvas panel. Inner lining should be washable. Tent should be provided with 2 doors & 3 windows made up of UPVC with 5mm toughned clear glass. Tent frame should be provided with wind supporting cables in 6mm steel wires anchored with heavy durty anchors complete as directed by engineer in charge. |
| 266 | Supplying and installing Office Signages Glass/SS with Vinyl as per Rooms cabin as per architects drawing and approved as Directed by Engineer-in-charge etccomplete. |
| 267 | Providing and fixing Bio-digester tank of capacity 1000 litres made up of sealed container and works principle of on anaerobic digestion by bacterial activity. Effulent water should be odorless, colorless and free of pathogens and can be used for gardening or recycled for flushing etc complete as directed by engineer in charge. |
| 268 | Antitermite Treatment of Floors - Providing, laying and applying Integrated Termite Exclusion Method - Anti-termite system Installation and Chemical application including laying of LLDP dripper pipe of 8 mm OD and 6.4 mm ID with built-in pressure compensation chip at every 0.30-meter interval on the pipe installed at a depth of 25 to 40 mm under the floor icluding excavating tranches and securing the pipes whith P Clips and cement mixtures and backfilling the same with good quality material. Pipe network loops are to be terminated in Junction box height of which will be maximum 1 ft from finished floor level. Pouring the antitermite chemical from Bayer or eqivalent make with the help of pressure pumps with working pressure of 2 kg/cm2 at the rate of 3 liter/sqm or as specified by the make. |
| 269 | Providing and fixing designer SS finish spout of premium series & bath accesories of brand Johnson/ Jaguar make/ equivalent including Single Leaver Concealed Divertor 1 number, Angle Cock 3 numbers, 2 Number Bib Cock, Single lever Basin Mixer 1 number, Jet Spray with Flexible Tube/ Hook 1 number, Jet spray Gun 1 number, Bath Spout Flow 1 number, Shower Arm, Waste Coupling Full Thread1 number, stainless steel fininshBottle Trap 1 number, Towel Rod 2 number, Soap Dish 2 numbers, Coat hook 1 number, Paper Holder 1 number, Tumbler Holder 1 number, Towel Ring 1 number, Towel Rack 1 number standard manufacture brackets, rubber plug necessary Screws, connections making good damaged surfaces testing etc. complete as directed by engineer in charge. |
| 270 | Providing and fixing 3.6 mm thk eco flex rubberised flooring laid on top of existing 150 mm thk PCC bedding as per approved shape and design cleaning etc .complete and as per direction of Engineer incharge |
| 271 | Providing & fixing automatic sliding glass door mechanism with of allumnium main track 6 metre long with glass clamp, digital micro control, dunker motor, toothed belt,infrared safety barrier, sensor, floor guide, pvc seal u type, brush seal, safety beam complete as per directed by Engineer in Charge. |
| 272 | Providing & fixing in position main curtain make of (GM/ Bombay dying or equivalent) of 0.75 m in width with balance road of approved quality & other required fixtures applied with power coating etc. provided with tussels to hold the curtain at one side of the wall, necessary feetings complete as directed by Engineer Incharge. |
| 273 | Providing & fixing in position sheer curtain make of (GM/ Bombay dying or equivalent) of 0.75 m in width with balance road of approved quality & other required fixtures applied with power coating etc. provided with tussels to hold the curtain at one side of the wall, necessary feetings complete as directed by Engineer Incharge. |
| 274 | Providing & fixing door closer for closing of doors with cap. To sustain weight of door of make tweka or similar type of ISI make |
| 275 | Providing & fixing floor spring for opening of doors with cap. To sustain weight of 16.5 kg and 50000 cycles of make tweka or similar type of ISI make |
| 276 | Providing and fixing in position Electronic Safe as per Architects drawing and Make approvedas Directed by Engineer-in-charge etc,complete. |
| 277 | Providing and placing in position chairs for cottage made withPitch woodchair in melamine polished of approved shade and fabric of size 450 X 610 X 960 as per Architects drawing and Make approvedas Directed by Engineer-in-charge etc,complete. |
| 278 | Providing and fixing in position First-aid box with first aid chart printed on the box with all first aid medicines such as sterilised dressings, antiseptic solutions, oinment for burn, crocin, first aid bookletas per Architects drawing and approved Make as Directed by Engineer-in-charge etc,complete. |
| 279 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FRgrademineral corefollowingNBC partIV Fireand lifesafety (having2 hoursfire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched betweentwoaluminiumsheets(each0.5mmthickofAA5005/AA3105grade)The aluminiumcompositepanelcladding sheet shallbecoil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having70:30ratioofPVDFandacrylic) coatingofapprovedcolourandshadeontopfaceandpolymer(service)coatingof bottom face as specifiedusingstainlesssteel screws, nuts, bolts, washers, cleats, weather siliconsealent,backerrodsetc. |
| 280 | Providing and supplying Bathroom Assessories like 17 liter Buckets, 2 liter Mug,dust bin , bathroom broom, etc. in bathrooms as per Architects drawing and approved Makeas Directed by Engineer-in-charge etc,complete. |
| 281 | Providing supplying HOT THERMOS with Handle as per Architects drawing and approved Make as Directed by Engineer-in-charge etc,complete. |
| 282 | Providing supplying Strong folding S.S. Cloth Dryer (2 ft x 5 ft)as per Architects drawing and approved Make as Directed by Engineer-in-charge etc,complete. |
| 283 | Providing and Supplpying Wall Clockas per Architects drawing and Make approved as Directed by Engineer-in-charge etc,complete. |
| 284 | Providing and supplying dry-wet Bath mat to all Bath room as per Architects drawing and approved as Directed by Engineer-in-charge etc,complete. |
| 285 | Providing and supplying dry-wet door mat to all rooms as per Architects drawing and approved as Directed by Engineer-in-charge etc,complete. |
| 286 | Providing and supplyingRug for double bed of approved qualityas per Architects drawing and Make approved as Directed by Engineer-in-charge etc,complete. |
| 287 | Providing and supplying Double bed-sheets and two pillows as per Architects drawing and Make approved as Directed by Engineer-in-charge etc,complete. |
| 288 | Providing and supplying Single bed-sheet and pillow as per Architects selection and Make approved as Directed by Engineer-in-charge etc complete. |
| 289 | Providing solid white bath towel made of superior quality cotton super soft and water absorbent Fully Hand and Machine Washable, Material :Cotton, 650GSM, Size: 75cm x 150cm as directed and Approved Quality by Enginner-in charge. |
| 290 | Providing solid white hand towel made of superior quality cotton super soft and water absorbent Fully Hand and Machine Washable, Material :Cotton, 650GSM, Size: 40 cmx 70cm as directed and Approved Quality by Enginner-in charge. |
| 291 | Providing and installing Pool Table & all related accessories as Directed by Engineer-in-charge etc, complete. |
| 292 | Providing and installingPool Umbrela & all related accessoriesas Directed by Engineer-in-charge etc, complete. |
| 293 | Providing and installingPool Benches & all related accessoriesas Directed by Engineer-in-charge etc, complete. |
| 294 | Providing and fixing wooden flooring with imported make venner paper fixed on MDF board of 8mmthick and width of 200mmU Shaped Notch to old the sheets in perfect floorig designbrand of Stilex Wooden moulding of imported make veneer paper fixed on MDF wood with finished edgeswhich is used at the end of wooden flooring and to the notches for affixing the wood to the flooring with 8mm Hilton n=below flooring and rubber adhesive to stick (Sample to be got approved from Exe. Engineer Before use) Spec. No. As directed by Engineer In charge. |
| 295 | Supplying had-weaving Kashmiri carpet in matural and artificial design which edges are overlocked, has various sizes 6ft x 4ft, 6ft x 3ft, etc. as per detailed drawings and as directed by Engineer in charge (Sample to be got approved from Exe. Engineer before use) |
| 296 | Supplying Ultra Super Soft Duvet 90 x 60 made from a unique soft and buttery slow-release fiber filling encased in specially coated premium fabrics as directed bu Engineer in Charge (Sampe to be got approved from Exe. Engineer before use. |
| 297 | Supplying Duvet single cover 92 x 62of Good Quality Duvet Covers Made From 100% Cotton Fabrics & Cotton Satin Fabrics With Customized Patterns As per required Sizes as directed by Engineer in chrge (Sample to be approved from Exe. Engineer before use) |
| 298 | Providing & Fixing Curtains / Roller Blinds of Vista Make including Rods Etc. complete |
| 299 | Provinding, Fixing and Making Artistic Texure Plaster of mixure of Dholpuri stone crystal material with Bubble Spray with Rough & ToughChemical Solvent on new Surfaces of 1.5mm Minimum Thickness with Appropriate Finishing, Colour and design approved by Engineer in Charge. |
| 300 | Providing and laying river washed white/grey PEBBLES/ Marble Pebbles of 20mm to 50 mm dia at landscaping areaover sub floor of compacted earth and fixed in cement slurry. |
| 301 | Supplying, erecting, testing and commissioning including design of Landscape automization system for existing irrigation work with all automatic valves,wires including design for 3.5 acers Using Programmable Logic Controller system and Establishment Automatic control system etc. complete. The system can be divided into four main parts: Level Sensor, PLC(Programmable Logic Controller), Relay and Motor, HMI(Human Machine Interface). The implementation is divided into four parts:- Sensor Positioning, Circuit Design, Ladder Programing & HMI Creation. The results shall be in four situations as Empty tank, Filling tank, Full tank & Draining for all tanks. The scope consists of providing operation manual, maintainace manual, training for clients team etc. complete. Payment shall be made based on design of entire system. as per Architects drawing/ images and Make approved as Directed by Engineer-in-charge etc, complete. |
| 302 | Providing and erecting pressure motor for increasing the pressure in plumbing line to get the uniform pressure at any trap at any level. The pressure range should be upto 4kg/cm2 and maximum HP of pressure motor upto 1.5HP, the motor shouldbe of submersible type with make of Grunforce/Texmo/Proton with ISI mark. |
| 303 | Providing and laying full body vitrified stone effect finish tiles having size 800 mm x 2400 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curign and cleaning etc. complete |
| 304 | Providing and fixing in position First-aid box with first aid chart printed on the box with all first aid medicines such as sterilised dressings, antiseptic solutions, oinment forburn,crocin,firstaidbookletasperArchitects drawing and approved Make as Directed by Engineer- in-charge etc,complete. |
| 305 | Providing and fixing Plastic Moulded Cat Eye Stud of size 100 mm x 100 mm at base with M.S. Zinc coated nails of size 12 mm dia. of 120 mm long having both as sides (Dual Direction) high impact ABC 3 Nos of eyes of 16 mm dia. on both sides containing 7 heads each i.e. 42 heads in retro reflector etc. complete. |
| 306 | Providing and fixing Luxuries Series in cermiac tiles of 613330 White/Black Waves biaeg/simmilar Catageory of Imported Johnson Make quality 60cm x33cm x 10mm or above size as per availablity in market or as directed by Engineer inchargefor flooring/Dado/Skirttingin required position laid on a bed of 1:4 cement mortor including Adhesive Like perma,plastoproof etc,cement float, filling joint with white/colour slurry cleaning curing complete.(Prior approval of sample and brand to be verifiy byEngineer in charge is necessary before use.) |
| 307 | Providing, laying and fixing GRP / FRP grating of 50 mm thickness over strom drain 450x600mm in size as directed etc. complete. Spec No.: As directed by Engineer-in- charge. |
| 308 | Providing, Fixing,Testing &Commissioning ofHydro pneumaticpumpingsystemconsistingof2Numbersof pumpsof Kirloskar/ equivalentwithVariableSpeedDrive, Common inlet and out let manifolds, Numbern-return valves andisolatingvalvesforeachpumpontheoutletside, pressure switches, outlet pressure gauge on the outlet manifold, a control panel to electrically switch on/off the pumps, , pressure vessel, all necessaryinterconnectionsfor the above items[1 unit = (1 Numbersworking + 1 stand by] Duty of each Pump = 3.4 lps@ 30 mtr Head, including all labours, GI pipe inside the pump room, all taxes if any. |
| 309 | Providing & fixing of Casement fixed window of approved make with DGU. The extruded aluminium sections of Alloy 6063 tolerances confirming to DIN standard from approved raw material V2 / V4 as directed by Engineer in charge. |
| 310 | Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 mm diaG.I.pipe(Rezan/concentiDeletedire0.75mm dia)withhotdipandG.I.coated hooks as per drawingsupportedonM.S.angle50x50x6mmat2.5mtr.c/c includingfixingand fastening with wire, painting M.S. angles with one coat of red lead primer and two coat of oil paint etc. complete. |
| 311 | Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top andbottom of 25 x 25 x 5 mm size andvertical M.S. flat 35 x 5 mm and25 x 5mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. |
| 312 | Providing and fixing in position bed back panelling of artificial leather / fabric cushion madeup of 8 mm to 12mm thick ply of approved make sides and exposed parts are finished with same material filled with 12 mm to 25mm thick foam or recron with spounge effect with good quality of glue or fevicol as directed by Engineer Incharge. |
| 313 | Providing and fixing 30 mm thick factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19mm for stiles & 15mm x 15mm for top & bottom rails M.S. frame shall have coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat molded PVC ‘C’ channel of size 30x50 mm forming stiles, 5 mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Paneling of 5mm thick PVC sheet to be fitted in the M.S. Frame welded/sealed to the stiles & rails with 30mm wide x 5 mm thick PVC sheet bedding on either side and jointed together with solvent cementadhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘c’ channel using PVC solvent cement adhesive etc complete as per direction of Engineer in charge, manufacturer’s specification & Drawing |
| 314 | Providingandfixing20to25mmthickroughshahabadboxtypewaterproofingfor basement orundergroundflooronabaseofCementconcrete1:3:6,includingsub baseof 2.50 centimeterthick Cementmortar 1:3with conceal,secrete (RMW),Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the jointswith 6mmsizecrushedmetal,handgroutingwithcementslurry,curingand cleaning,with7yearsguaranteeoncourtfeestampofRs.100/- withpondingtestetc complete. (excluding Cement concrete 1:3:6 base concrete ) |
| 315 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gapof 25 mm betweenrough shahabadand R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method,brushing the joints horizontally with cement slurry mixed with water proofingliquidfor width 30 to 35 mm and sloping coping over topmost tile with cement mortar1:3,buttingthebottom most with Cement concrete1:2:4 mixed with water proofing liquid,curing,with7 yearsguaranteeoncourtfeestampofRs.100/-with ponding testetccomplete.(excluding Cement concrete 1:3:6 base concrete) |
| 316 | Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing andsubmittingstratachart/borelog,includinghire&runningchargesof all equipments,tools,plants&machineryrequiredforthejob,allcompleteasper directionof Engineer in charge, upto 90m depth below ground level. |
| 317 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVCmedium well-casingpipe of150mm dia,conforming toIS:12818, includingrequired hireandlabourcharges,fittings&accessoriesetc.allcomplete, foralldepths,asperthe direction of Engineer in charge. |
| 318 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticizedPVCmediumwellscreenpipeswithribsof100mmdia,conformingto IS:12818,includingrequiredhireandlabourcharges,fittings&accessoriesetc.all complete, for all depths, as per the direction of Engineer in charge. |
| 319 | Providing & fixing vinyl self adhesive glass film from opaque white to full transparency while still allowing natural light to fill the room complete as directed by engineer in charge. |
| 320 | Providing & installing Lounge Chair made out of base material as metal & primary material Leather & Cotton of 660+/- 5% GSM, Dimensions (Cm) 81.3L x 68.6W x 76.2H ,etc. complete as directed by Engineer in Charge. |
| 321 | Supplying,erecting and installation 4 meter boom barrier with LED lights along with manual option in case of power failure equipped with a manual knob which enables the operater to open or close the barrier, heavy duty, wether proof and simple design housing. Opening or closing speed of3 to 4 sec, IP rating of IP88 , housing base frame ofmild steel |
| 322 | Providing deep cleaning to entire resort including all consumables, skilled, semi skilled workers etc complete as directed by engineer in charge. |
| 323 | Providing & supplying Air Purifier-cum-Dehumidifier with plasmacluster and true HEPA & Active Charcoal & Pre-filter, extraction capacity: 20 Liters/Day, tank capacity: 4.6 Liters, modes: Auto, Dehumidifying, Laundry, Deodorizing, Auto, Sleep, Medium & High, Clean Air Delivery Rate (CADR) : 258 m3/Hr, recommended Coverage Area : Upto 550 Sq. Ft. (50 Sq. Mtrs.) , Sensors: Odour, Light, & Water Tank Full, Real-time Monitor: PM2.5, Temperature & Humidity, Power Consumption: Dehumidification & Laundry: 260 Watts Air Purification only: 50/7.3, Inverter Operation Compatible. Unit Dimensions: 35.9 x 66.5 x 30.1 cm (W x H x D) , Warranty: 1 Year complete as directed by engineer in charge. |
| 324 | Providing and grouting the holes by PolyCeramicCementitiousi.e NicGrout G06 + 53gradecementmaterialofasperrequirement toreducetheporosity ofconcrete/ Masonry structure and to increase the strength of structure usinggrouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge. |
| 325 | Providing and fixing fly proof mesh shutter toventilator / window using CCTW members of size 45 x 22 mm for frame work and 35x 22 mm for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 mm including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etc. complete |
| 326 | Providing & supplying Dehumidifier having UV & Ionizer technology, Auto Defrost, Overflow Protection, Timer, Quiet Operation, Capacity - 5 Litres, tank volume: 5 Liters, Dehumidification capacity - 20 litres per day, it should deliver cleaner, drier, and healthier air Equipped with advanced Ionizer and UV technology, this powerful unit not only removes excess moisture but also reduces odors, bacteria, and airborne germs, making it ideal for homes, basements, and other humidity-prone areas including features intelligent functions like Auto Defrost, Overflow Protection, and a programmable Timer for hassle-free operation. complete as directed by engineer in charge. |
| 327 | RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge |
| 328 | RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid /perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural and / crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 329 | Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20cm in recharge pit, in the required thickness, for all leads & lifts, all complete as per the direction of Engineer-in-charge. |
| 330 | Supplying, filling, spreading & leveling gravels of size range 5mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. |
| 331 | Supplying, filling, spreading & leveling coarse fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) of size range 1.5mm to 2mm in recharge pit, in required thicknessover gravel layer, for all leads & lifts, all complete as per direction of Engineer in charge. |
| 332 | Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel: fine/ medium/ coarse, in required grading & sizes as per the actual requirement, all complete as per direction of Engineer in charge. |
| 333 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 334 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 335 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 336 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 337 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 338 | Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 339 | Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 340 | Supplying anderectingPVCboxtrunking ofsize50x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX. |
| 341 | Supplying anderectingPVCboxtrunking ofsize 75x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX. |
| 342 | Supplying and erecting 20mm dia. corrugated flexiblepolypropyleneconduit |
| 343 | Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit |
| 344 | Supplying anderectingPVCboxtrunking ofsize 75x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX. |
| 345 | Supplying anderectingPVC slotted box trunking ofsize75x75 mm. with accessorieson wall/ceiling as per specification No: WG-MA/SLBOX. |
| 346 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 347 | Supplying and erecting GREEN EARTH with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 348 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 349 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire to be use for earthing laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 350 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 351 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire to be use for earthing laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 352 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 353 | Supplying and erectingmodular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete. |
| 354 | Supplying and erectingmodular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 355 | Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 356 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 357 | Supplying and erectingmodular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 358 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW |
| 359 | Supplying and erectingmodular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 360 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 361 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (For item no. 18) |
| 362 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 363 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (For item No. 17) |
| 364 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 365 | Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVCconduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW. |
| 366 | Point wiring for ceilingfan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 367 | Secondary point wiring for additionallight/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 368 | Supplying and installing enhanced cat-6 LSZH cable with 4-connector channel Performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification. |
| 369 | Supplying and installing cat-6 armouredcable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 370 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC |
| 371 | Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC |
| 372 | Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 373 | Supplying, fixing, and configuring 24 ports + 4 (SFP+) port, Managed Layer 2, POE Switch of , 370W, 6KV surge protection on ethernet port and console port for management erected in provided rack complete. |
| 374 | Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 375 | Supplying, fixing, and configuring modularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz, with RJ-45 port, supporting1 to 13 channels for 2.4 GHz, with unified wireless access point complete. |
| 376 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 377 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 378 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ |
| 379 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 380 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coatedmetal with necessary arrangement for fixingas per specification No. WG-NAS/RAK |
| 381 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 382 | Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrentaccess point with POE in networking as per specification no. WG-NAS/LAP2 |
| 383 | Supplying, installing and activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete. |
| 384 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC |
| 385 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 386 | Supplying, erecting, testingandcommissioning of 10kVA capacity onlinepure sine wave, with backup time of 20 minutes. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protectionsas per specification no. AP-UPS |
| 387 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 388 | Professional charges towards obtaining permission for installation as well as the rate shall be inclusive of Filing the completion report for the LOCAL EB, CEIG portion of work to the Electrical Inspectorateauthorities, getting the inspection done at site, filling the compliance report, getting the approval from Electrical Inspectorate authorities and getting the approval from EB etc., including liasoning with EB, CEIG, other related local authorities for obatining power sanction, filling up of applications if any complete as required. |
| 389 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 390 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 391 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB |
| 392 | Supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40Awith required wiring connections and lugs etc. in provided distribution board. |
| 393 | Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63Ain provided distribution board. |
| 394 | Supplying&erectingtriplepoleand neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flushmounted,IP 43 Protection on iron/GI frame (horizontal busbar type)as per specification no. SW-SWR/MCBDB |
| 395 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 396 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 397 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 398 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 399 | Supplyinganderectingblankingplate of suitable size on MCBDB. |
| 400 | Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 401 | Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivityand short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 402 | Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating ,APFC panel shall be compliance to IEC 61439 and power qualityIEC 61921 standard as per specification no CP-ED/APFC |
| 403 | Supplying and erecting LED COB Downlight with reflectorcircular Max. 15W Operating Temperature 10℃ to 40℃,Rated Input Voltage & Frequency 220-240 VAC, 50Hz,THD <15% Rated Luminous Flux 1125 lm / 1050 lm / 975 lm (tolerance as per BIS),Rated Luminaire Efficacy 75 lm/W /70 lm/W / 65 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 45°, colour rendering index CRI>90, Driver Efficiency ≥80% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20, Impact protection IK02, Provided Short Circuit Protection , Open Circuit Protection, Reverse Polarity Protection Engineer incharge |
| 404 | Supplying and erecting LED COB Downlight with reflectorcircular Max. 8W Operating Temperature 10℃ to 40℃,Rated Input Voltage & Frequency 220-240 VAC, 50Hz,THD <15% Rated Luminous Flux 560 lm / 520 lm / 480 lm (tolerance as per BIS),Rated Luminaire Efficacy 70 lm/W / 65 lm/W / 60 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 36°, colour rendering index CRI>90, Driver Efficiency ≥80% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20, Impact protection IK02, Provided Short Circuit Protection , Open Circuit Protection, Reverse Polarity Protection Engineer incharge |
| 405 | Supplying and erecting LED COB with reflector Downlight circular Max. 25 to 30W Operating Temperature 10℃ to 40, Rated Input Voltage & Frequency 230 VAC, 50Hz,THD <15% Rated Luminous Flux 2850 lm / 2700 lm / 2550 lm (tolerance as per BIS),Rated Luminaire Efficacy 95 lm/W / 90 lm/W / 85 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 38° Driver Efficiency ≥85% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20 Provided Short Circuit Protection , Open Circuit Protection ,Reverse Polarity Protection etc complete |
| 406 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 407 | Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimumlumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg.,THD<10%, p.f. >0.95, operating range of230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty. |
| 408 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. |
| 409 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt,CRI>80, CCT of 6500K and THD<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. |
| 410 | Supplying & erectingUV Fly killer/ bug catcher Light Fittinghaving 2 x 20W UV Tube Lights to cover min. area of 500 sq.ftwith powdered coated M.S./ steel body suitable to work on 230V, AC Supply having top mounting arrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty. |
| 411 | Supplying and erecting Decorative energy saving ceiling fan with remote control 230 V A.C. 50 cycles 1200 mm complete erected in position as per Make,HAVELLS,CG Etc |
| 412 | Supplying and erecting air mate pedestal fan 230 mm. sweep oscillating type, wattage 45W, 1800 RPM with remote, air delivery 60 CMM, Ac Motor, silent operation, wider angle air flow with 90 horizontal oscillation, 3 speed levels, 8 hours programmed timer, power off memory function, LED display, easy to check speed level, touch buttons, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 413 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 414 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 415 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 416 | Supplying, installing, testing and commissioning tower type room AC unit of 4.0TR to 4.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/R410A & copper condenser coil with anticorrosive fins copper condenser, hydrophilic evaporator Fins Powder coated outer body, with scroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe. |
| 417 | Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 418 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 419 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. |
| 420 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. |
| 421 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 422 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 423 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 424 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core2.5sq. mm. copper conductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 425 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 426 | Supplying, installing, testing & commissioning split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete withtemperature display on indoor unit, noise level maximum 50dBAat positionas per specification no. AP-AC/WAC |
| 427 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 428 | Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 429 | Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 430 | Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing,havingsystem lumens output of Min. 500 Lumens, min. efficacy of 85 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of100-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50, including driver, salt spray tested for 500 Hrs. including making of recess of appropriate size for flushing into surface with 2 Year warranty as per specification NoFG-ODF/FLS2. |
| 431 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation. |
| 432 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 433 | Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 434 | Supplying & erectingcast iron cable indicatorplate buried along with route of cable for PVC / XLPE armoured cableas per specification no. CB-CIP |
| 435 | Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP |
| 436 | Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply ofsteel, concrete, excavation, fixing provided nut bolts with the help of template,duly plastered as per design complete (for 3 to 5m octagonal / conical GIpole). |
| 437 | Supply, Installation, Testing and commissioning of 3660mm height pole made of circular mild steel pipe (grade YST 210) 88.9mm Dia x 2.9mm thick with 2650mm Height. Decorative base made of gravity cast aluminium Ø245 x 206mm height with company logo embossed on bottom of the base and decorative twelve projecting vertical bands.The single arm bracket is a split constructed type, Bracket stem made of MS pipe 50.8mm Dia x 2.3mm thick, emerging from a gravity die cast aluminium embellishment in gold or black finish of 60mm, curved upto a height of 940mm and the descending arm, spruced up with MS Sheet creeper design embellishment and facilitates the fitment of luminaire at 600mm from the vertical axis of the bracket stem. Pole section welded by certified welders using high end Magnesium Inert Gas welding processes. Pressure Die Cast aluminium service door 348mm height x 80mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The bottom of the door is loacted at a height of 500 mm from its base plate. The control gear tray is prewired with a single Core 2.5 Sq.mm PVC wire, 6A SP MCB of Approved make and with 32A stud type 4 way terminal block to take incoming cable with loop-in / loop-out arrangement and to be connected with lugs and has a5 amp, 2 way terminal connector for luminiare and a provision for earthing. Any other internal cables and connections shall be covered in the contractors scope. Mild steel mounting plate 230mm Dia x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 300mm bolts of grade 4.6 at Pitch Center Distance 180mm. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate alongwith foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 5% tolerance. After fabrication, entire pole should be shot blasted (Inhouse). After shot blasting the pole should be coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer andfinished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options |
| 438 | Supply installation testing and commissioning of Tier drop Luminaire of 40/50W. Decorative pendant / Hanging mounted compact street light. Type IV (Asymmetrical light distribution). Decorative luminaire made of specially contoured spun aluminium body of high corrosion resistance with a neck design for unique and better aesthetics and non corrosive stainless steel fasteners. Clear polycarbonate diffuser. The luminaire have extruded aluminium heatsink for thermal management with vertical fin design for longerlife of the LEDs. The mounting arrangement nipple, coupling & Hex nut made of Stainless steel 304 suitablefor mounting to internally threaded pipe of designation M30. Protection class IP65. Mechanical resistance IK09 (Polycarbonate diffuser). Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K / 5700Kas per TMC Engineer and as per application. Colour rendering index (CRI)>70. Standard Deviation colour matching 3MacAdam. Led module with expected service life of at least 72,000 operating hours. Driver shall be of approved make and are a Fixed constant current driver with an output current of 1200 MA, 48Vdc ,58W. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply.Driver efficiency > 85%, power factor > 0.95, THD < 10%, internal Surge Protection 6KV of the driver. Input Rated Voltage is 240V,50-60 Hz. Input operating voltage range of 100-300 Vac. The driver shall have short circuit protection with automatic restart, Overvoltage Protection, thermal protection and No load protection. Led Source shall be of Nichia / Lumiled/ cree orEquivalent Make and shall be of standard deviation colour matching to 3 Step Mcadam. External SPD of 10KV shall be provided along with the fixture. Luminaire dimension : 425mm diameter x height 407 mm / 437mm. BIS Certified for Luminaire. |
| 439 | Supply & Installtion of providing Lantan of FRP body with polycarbonate or glass diffuser approx sixe 1 feet to 3 feet, wall mount/ pole mount/ hanging , colour temp 3000K or 4000K/6000K, IP Range IP 65 for out door,MS frame with powder coated with 2 lantern fittings 60W LEDeach, to be install at landscape area as per engineer incharge |
| 440 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copperwoundNon-sealed transformerdelta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance methodin winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 441 | Supplying, installation, testing and commissioning extendable/non-extendable indoor type 11 kV, 630A,load break switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench/foundations per specification no SW-HTS / LBS |
| 442 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) |
| 443 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB. |
| 444 | Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter. |
| 445 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 446 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu),adjustablethermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 447 | Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8) |
| 448 | Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8) |
| 449 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 450 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus barchamber / in panel or any other purpose, 500 V with require capacity 99.9%aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 Aper sq. mm. with fixing arrangement (like lug or bottle type lug) to both the endwith high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 451 | Supplying and erecting triple pole Powerder coatedmini feeder pillarwith500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG GP 270 GSM sheet box with supporting angles with hot dip GI angle, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation. |
| 452 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 453 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core185 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 454 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 455 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 456 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 457 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 458 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable11 kV(E), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 459 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG |
| 460 | Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. |
| 461 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD |
| 462 | Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). |
| 463 | Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete. |
| 464 | Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 465 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA output continuous rating to CPCB IV plus emission compliant with output contineous rating, 3 phase, 415V, 50c/s, 0.8 pf, 1500 rpm with 10% overload for 1 hour in 12 hours, along with standerd accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001with voltage regulation +/-0.5% with performance class G2 both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standerd control panel, comprising meter, switchgear, indicator connected with suitable wire/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound obsorbing material to restrics sound level upto 75 DB at 1.0 m., with first filling oil, diesel tank capacity not less than 260 litres etc. on provided M-20 grade CC foundation and obtaining necessary approval from Electrical Inspector if necessary. This DG set is fitted in soundproof & weather proofAcoustic Enclosure as per CPCB-IV Plus Emmision Compliant (With Acoustic Enclosure) For all the Engines, the emission standards/norms shall meet applicable pollution control board norms as amended by Government.(CPCB IV) |
| 466 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating setof above 140 kVA up to 180 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 467 | Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP |
| 468 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 469 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbonbased environment friendly back fill Ground Enhancing compoundcomplete with all materials, testing & recording the resultsas per specification no ESE -LA |
| 470 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. Cu strip 25X3 mm = 0.7kg/meter. Hence for 240 meters - 240*0.7 =kg |
| 471 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clampsfixed on wall painted with insulating and non-corrosive bond with requiredjoints As per specification no. EA-EP. EA-EP. To be use for Lightning Arrestor. Cu strip 25X3 mm = 0.7kg/meter. Hence for 540 meters - 540*0.7 =kg |
| 472 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsAs per specification no. EA-EP. GI strip 25X6 mm = 1.25kg/meter. Hence for 520 meters - 520*1.25 =kg |
| 473 | Supplying & erectingconventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. |
| 474 | Providing and back filling ground enhancing compound 25 kg bag complete. |
| 475 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 476 | Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 477 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 478 | Supplying, Installing, Testing & Commissioning of 4 Way Cree Light 4X3W CL COB SPOT 4D high pressure aluminium die cast 3000 K IP 65 as per approved drawing and design or as approved by the Engineer In charge. |
| 479 | Providing and making second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 480 | Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. |
| 481 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). |
| 482 | Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. |
| 483 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). |
| 484 | Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 Kv complete as per specification No. CW-EXN-CTR |
| 485 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 486 | Supplying and installingcat-6 cable with rodent proof and anti termite jacket suitable for networking as per specification No. WG-COC/NC |
| 487 | Supplying and installing cat-6 armouredcable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 488 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 489 | Supplying& erecting of High definition 4/5 Megapixel IP IR Dome Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change etection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 490 | Supplying& erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. |
| 491 | Supplying& erecting of High definition 2 Megapixel IP IRPTZ Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution:minimum 1920 x 1080Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame Rate : minimum 30 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant.Auto Tracking, Pre-set Tour Settings, Pan : 360° endless, Tilt : From -15° to 90° (auto-flip 180°) , minimum Pan Speed - from 0.1°/s to 160°/s, minimum Preset Speed: 240°/s, minimum Tilt Speed- from 0.1°/s to 120°/s, minimum Preset Speed: 200°/s, MinPresets - 250,minimum IR distance : 100m, Lens Type : minimum 4.3 - 125mm Lens min 16 x digital zoom, min 30 x optical Zoom, Focus Mode : Auto/Zooming/One Push Manual, Lux sensitivity : minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR), Night Vision Distance minimum IR- 100m,Power Supply : support 12/24 VDC, 24 VAC & PoE, IP67/IP66, IK10, built in micro SD/SDHC/SDXC card slot, minimum 256 GB,built in microphone. minimum Input/Output -Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature (-30 to 60° C) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 492 | Supplying, installing, testing & commissioning of 32/40 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG,Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology,8 SATA interfaces for 8HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface,support multibrand network Cameras, ONVIF conformance,Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR |
| 493 | Supplying& erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S,maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB,MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 494 | 16 port Unmanaged Network PoE Switch: L2, Unmanaged, 16 Gigabit POE ports, 1 Gigabit RJ45 uplink port, 1 Gigabit SFP uplink port, 802.3af/at, PoE power budget 230w |
| 495 | Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. |
| 496 | Supplying and erecting 5m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 497 | Supplying& erecting 55\" professional LED display with 1920 *1080 ( Full HD)4k Smart Display, suitable for 32/64 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 498 | Supplying& erecting 43\" professional LED display with 1920 *1080 ( Full HD)4K Smart Display, suitable for 32/64 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 499 | Server for Video Management Software to manage and maintain the digital I/O summary |
| 500 | Server for Redundancy for Video Management Software Back up of vital information and for data sharing, data transfer |
| 501 | Display For VMS Sever: 31.5\" 1080P, HDMI/VGA input, view angle: 178°/178°, 300cd/㎡, plastic casing, VESA, base bracket included, 7*24h HIK VISION MODEL NO.DS-D5032QE or equivalent |
| 502 | Supplying and erecting storage type water heater 15 litres capacity havingstanding loss <0.419 kWh / 24 hour / 45°C, high impact resistanceengineering plastic body with anti corrosive high grade steel inner tankheating element having hard water & corrosion protection, with minimum3 safety protections (i.e. thermostat & thermal cut-out, multi functionvalve) with total pressure 8 bar withstanding capacity duly tested and marking sr.no. and date of erection complete. specification no. AP-WH/STWH |
| 503 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 504 | Supplying, erecting, testingandcommissioning of 6kVA capacity online pure sine wave with backup time of 20 minutes. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS |
| 505 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete. |
| 506 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 507 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849/15683 of 1 kg capacity with necessary clamp for erection on wall. |
| 508 | Supplying and erecting ABC powder typefire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 509 | Supplying, installing, testingand commissioning FR, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU |
| 510 | Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button andflip abort switch or agent release switch in metal enclosure complete asper specification no. FF-FAAS/MCP |
| 511 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR |
| 512 | Supplying, installing, testingand commissioning 2 Zone, localsignal control panel (LCP) with standard accessories complete asper specification no.FF-FAAS/LCP |
| 513 | Supplying, erecting,testing and commissioning 120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR |
| 514 | Supplying,erecting, testing and commissioning 15 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC |
| 515 | Supplying,erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC |
| 516 | Supplying,erecting, testing and commissioningrust free microphone table stand of chrome plating/powder coating or S.S. material,up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete. |
| 517 | Supplying,erecting, testing and commissioning of 2 core shielded cable complete asper specification no.FF-PA/MCC |
| 518 | Supplying,erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. |
| 519 | SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with· Rated capacity :- 15 Passenger/1020Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL [applicable for Passenger Liftwith MRL only & Stretcher/Hospital Lift with MR & MRL]· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x 2000mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days min. with 18” FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as \"T\" section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.Minor civil work such as alteration work if any necessary for erection oflanding door frames and it\"s accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erectionpermissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) withsubmission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the dateof commissioning. |
| 520 | For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 521 | For Full Collective control system, add as below. For Lift travellingabove First floor & up to Sixth floor |
| 522 | For additional 2MP Camera along with necessary accessories at Home Landing, add as given. |
| 523 | Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 524 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 525 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core4sq mm copper conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 526 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core2.5sq. mm. copper conductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 527 | REFRIGERATOR : Supplying refrigerator domestic type approved make 47 litres storage capacity , suitable for operation on 230/250 Volts 50 cycles complete with automatic temperature control confirming to IS specification No. 1476/79 with one year guarantee for sealed unit in refrigeration system and marking Sr.No.and date of erection. (Videocon VCP063SH-RDA Single Door 47 Litres Refrigerator) |
| 528 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. GI strip 25X6 mm = 1.25kg/meter. Hence for 40 meters - 40*1.25 |
| 529 | Providing, erecting & commissioning 4 pole RCCB 40A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB |
| 530 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 531 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 532 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 533 | Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 534 | Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. |
| 535 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 536 | Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 537 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 538 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 539 | Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 540 | Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 541 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 542 | Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 543 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3module duly erected. |
| 544 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. |
| 545 | Supplying and erecting LED Sencer sutaible for Down light up to 18 watt 230 V AC 50 cyclescomplete erected in position as Engineer In charge |
| 546 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 547 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 548 | Supplying and erectingenergy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 549 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 550 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 551 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 552 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 553 | Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. |
| 554 | Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC |
| 555 | Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP |
| 556 | Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 557 | Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only. |
| 558 | Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only. |
| 559 | Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) |
| 560 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 561 | Supplying and erecting 75/80 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 562 | Supplying anderecting75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS |
| 563 | Supplyinganderecting75/80mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 564 | Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy