Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-08-2025 | Correction of Name in BOQ | Other | 20-08-2025 |
| Sl. No. | Item Description |
| 1 | Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. |
| 2 | Dismantlingbrickmasonryinlimeorcementmortarandstackingthematerilsas directed with all leads, lifts etc. |
| 3 | First Floor |
| 4 | Removinglimeorleancementconcreteincludingstackingthespoilsasdirectedwithall leads, lifts etc, complete. |
| 5 | First Floor |
| 6 | Removing brick bat coba including stacking the spoils asdirected withallleads, liftsetc, complete. First floor |
| 7 | Removingcementtiles,ormarbleorpolished shahabadfloorordadowithoutbed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 8 | First Floor |
| 9 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete. |
| 10 | First Floor |
| 11 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 12 | First Floor |
| 13 | DismantlingtheR.C.C.Work1:2:4andsortingoutthematerialssuchassteeletc.as directed and stacking them within the specified lead as directed etc. complete. |
| 14 | First Floor |
| 15 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removingthe samecarefullyandstacking the serviceable materials as adnwhere directed includingthrowingthe unserviceablemateriaslsoutsideetc.carefullyandthrowingouttherefusaloutsideetc. complete. |
| 16 | First Floor |
| 17 | Supplying,Drilling/Cleaningholeandinjecting chemical.Applicationtobedesigned separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023orrelevanttestedandacceptedrebarguidelines.ThechemicalshouldhaveETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flutetypedrillbitsorhollowdrillbitstotherequireddepthbyrotaryhammerdrill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. Theinstallationandthesettinginstructionsshouldbestrictlyfollowedasperthe manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decidedasperPROFISRebarSoftware&thereporttobesubmittedtotheproject manager/designengineerforapproval.Scanningbeforedrillingtobedonetoavoid hitting existing rebars. Re 500 -8mm dia 160mm depth |
| 18 | First Floor |
| 19 | Supplying,Drilling/Cleaningholeandinjecting chemical.Applicationtobedesigned separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023orrelevanttestedandacceptedrebarguidelines.ThechemicalshouldhaveETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flutetypedrillbitsorhollowdrillbitstotherequireddepthbyrotaryhammerdrill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. Theinstallationandthesettinginstructionsshouldbestrictlyfollowedasperthe manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decidedasperPROFISRebarSoftware&thereporttobesubmittedtotheproject manager/designengineerforapproval.Scanningbeforedrillingtobedonetoavoid hitting existing rebars. Re 500 -10 mm dia 200mm depth |
| 20 | First Floor |
| 21 | Supplying,Drilling/Cleaningholeandinjecting chemical.Applicationtobedesigned separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023orrelevanttestedandacceptedrebarguidelines.ThechemicalshouldhaveETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flutetypedrillbitsorhollowdrillbitstotherequireddepthbyrotaryhammerdrill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. Theinstallationandthesettinginstructionsshouldbestrictlyfollowedasperthe manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decidedasperPROFISRebarSoftware&thereporttobesubmittedtotheproject manager/designengineerforapproval.Scanningbeforedrillingtobedonetoavoid hitting existing rebars. Re 500 -12 mm dia 240mm depth |
| 22 | First Floor |
| 23 | Supplying,Drilling/Cleaningholeandinjecting chemical.Applicationtobedesigned separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023orrelevanttestedandacceptedrebarguidelines.ThechemicalshouldhaveETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flutetypedrillbitsorhollowdrillbitstotherequireddepthbyrotaryhammerdrill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. Theinstallationandthesettinginstructionsshouldbestrictlyfollowedasperthe manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decidedasperPROFISRebarSoftware&thereporttobesubmittedtotheproject manager/designengineerforapproval.Scanningbeforedrillingtobedonetoavoid hitting existing rebars. Re 500 -16 mm dia 320mm depth |
| 24 | First Floor |
| 25 | Supplying,Drilling/Cleaningholeandinjecting chemical.Applicationtobedesigned separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023orrelevanttestedandacceptedrebarguidelines.ThechemicalshouldhaveETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flutetypedrillbitsorhollowdrillbitstotherequireddepthbyrotaryhammerdrill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. Theinstallationandthesettinginstructionsshouldbestrictlyfollowedasperthe manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decidedasperPROFISRebarSoftware&thereporttobesubmittedtotheproject manager/designengineerforapproval.Scanningbeforedrillingtobedonetoavoid hitting existing rebars. Re 500 -20 mm dia400mm depth |
| 26 | First Floor |
| 27 | Excavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 28 | Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metres beyondthebuildingareaandstacking andspreading as directed,dewatering, preparing the bed for the foundation and necessary back filling, ramming,watering including shoring andstrutting etc.complete.(Lift from1.5 to3.0m.) By Mechanical Means |
| 29 | Providing solingusing 80 mmsize trap metal in 15 cm. layer including filling voidswith Crushed sand/grit, ramming, watering etc. complete. |
| 30 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) |
| 31 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)treatment bytreatingthebackfillinimmediatecontactwithfoundationattherateof5litresof emulsionconcentrateof1.0percentofclorophyrifosper OneSquareMetreofvertical surface area covering 10 years guarantee on bond paper. |
| 32 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0 percent ofclorophyrifos per OneSquareMetreofsurfaceareacoveringtenyearsguarantee on bond paper. |
| 33 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm. Layers including watering and compacting etc. complete. |
| 34 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering andcompactionetc. complete. |
| 35 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations likeraft, strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping, compaction and curingrougheningthesurfaceifspecialfinishistobeprovided (Excluding reinforcementand structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 36 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawingsoras directedincludingsteelcentering,formwork,coverblocks, laying/pumping, compactionfinishingtheformedsurfaceswithcementmortar1:3of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabledreversible DrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) |
| 37 | First Floor |
| 38 | Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintelsas per detailed designs and drawingsorasdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be provided andcuringetc.complete.(Excludingreinforcement and structural steel).with fully automaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumType mixer/ concrete Batch mix plant (Pan mixer) etc.complete.Withfineaggregate (Crushed sand VSI Grade) |
| 39 | First Floor |
| 40 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/ quartzite/gneissmetal forR.C.C.chajjaasperdetaileddesignanddrawingsincluding steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 41 | First Floor |
| 42 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-25oftrap/ quartzite/granite/gneissmetalforR.C.C.Waistslab,andstepsofstaircasesasper detailed design and drawingsorasdirectedincludingsteelcentering,plywood/steel formwork, steel props,laying/pumping, compaction, finishinguneven and honeycombedsurface withC.M.1:3of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessor basedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 43 | First Floor |
| 44 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete,(Excludingreinforcementandstructural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabledreversible DrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade) |
| 45 | First Floor |
| 46 | Providing and laying Cast in situ/ReadyMix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windowsmouldedasperdetaileddrawingsorchamferedasapprovedby theEngineer includingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing androughening them if special finish is to be provided and curingcomplete.(Excluding reinforcementandstructuralsteel).withfullyautomatic micro processor based PLC withSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 47 | First Floor |
| 48 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C.pile caps,footings,foundations,slabs,beams columns,canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 49 | First Floor |
| 50 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundationandplinthincluding bailingoutwatermanually strikingjoints,rackingout joints watering and scaffolding etc. complete. |
| 51 | Providing Autoclaved Aerated Concrete Block masonary ofconformingtoIS:2185 (Part3)- 1984inextrafinejointingmortaroffixoblockof UltraTechor equivalentin superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 52 | First Floor |
| 53 | Providing Autoclaved Aerated Concrete Block masonaryof conformingtoIS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech orequivalentin Halfbrickthickwallincludingstrikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 54 | First Floor |
| 55 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4 withoutneeru finish to concrete or brick surfaces, in all positionsincluding scaffoldingand curing etc. complete. |
| 56 | First Floor |
| 57 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 58 | First Floor |
| 59 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FRgrademineral corefollowingNBC partIV Fireand lifesafety (having2 hoursfire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched betweentwoaluminiumsheets(each0.5mmthickofAA5005/AA3105grade)The aluminiumcompositepanelcladdingsheetshallbecoilcoatedwithkynar500based PVDF/Lumiflonbasedfluropolymerresin(having70:30ratioofPVDFandacrylic) coatingofapprovedcolourandsg=hadeontopfaceandpolymer(service)coatingof bottomfaceasspecifiedusingstainlesssteelscrews,nuts,bolts,washers,cleats,weather siliconsealent,backerrodsetc.overallweightoftheACPshallnotbelessthan7.5 Kilogram/ Sqm) |
| 60 | First Floor |
| 61 | Providingand applying impression24carratLuxurypaintofapprovedmake& approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surfaceintwocoats,includingsubsurfaceprparationbyAcrylic puttyandAcrylic primer coats including scaffolding, preparing the surface. etc. complete(Low VOC). |
| 62 | First Floor |
| 63 | Providing and applyingantipeel paint of approvedmake &approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in twocoats,includingexterioracrylicprimercoat,scaffolding,preparingthe surfaceetc. complete (HeatReflective Paint). |
| 64 | First Floor |
| 65 | Providingandlayinginpositionflooringoftelephoneblack/AmbaWhite/Catbary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thickon bed 1:6cement mortarincluding cementfloats strikingjoints, pointinginC.M. 1:3 curing and cleaning etc. complete. |
| 66 | Providingandfixingmachinecutmachinepolished18mmto20mmthicktelephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete. |
| 67 | First Floor |
| 68 | ProvidingleatherfinishedpolishingtoGraniteStoneslabby continuousgrindingin4 coatsof different bits to receive rough and matt finish including buffing process before laying and fixingofstoneasperdrawinganddesign,includingcleaning,washingandfinishingetc. complete. |
| 69 | First Floor |
| 70 | Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc.OnC.M.1:6includingfillingjointswithpolymerbasefillernosing/mouldingthe sharp edges wherever necessary, curing,etc. complete. |
| 71 | First Floor |
| 72 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternforflooringinrequiredpositionlaidonabed of1:4cementmorar including neat cement float, filling joints, curing and cleaning etc.complete. |
| 73 | First Floor |
| 74 | Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternfordadoandskirtinginrequiredpositionfixed in1:4cementmortar including neat cement float, filling joints, curing and cleaning etc.complete. |
| 75 | First Floor |
| 76 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc.complete |
| 77 | First Floor |
| 78 | Providingandfixingoffactory madeuPVCSlidingwindow&door(WhiteColour)3 Track with Mesh-2 Glass Sash + 1 Mesh Sash complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section1.5 mm, wherever required.uPVC window & door profile shall be made in India &shallconformtoBSEN12608andotherstandardsasmentionedbelow: S.No. Name of the testTest MethodSpecified Parameter1 Tensile Impact Strength ISO 8256- more than 700Kj/m22 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glassinthesash,uPVCglazingbead,interlock,EPDM/TPEgasket,brushshallbe providedincludingtouchlockandrollers&properdrainagesystemshallbeprovided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profilesarewarrantedforaperiodoften(10)yearsagainstnon-uniform discoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window)(Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm. |
| 79 | First Floor |
| 80 | Providing and fixing in position powder coated aluminium louvered windows / ventilator ofvarious sizes with powder coating as per detailed drawing and specifications including aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheet glasslouvers,of approved quality etc. complete. |
| 81 | First Floor |
| 82 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete |
| 83 | ProvidingandfixingCountry cutteak wooddouble orsingle leafpanelled shutters,35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thickandpanels without ventilator as per detailed drawing excluding the door frame, stainless steelfixturesandfasteningandfinishingthewoodworkwithoilpainting 3 coats complete |
| 84 | Solid Core Flush door Single leafProvidingandfixingfactorymadesolid coreflushdoorinsingleleaf35mmthick, decorativetypes,ofexteriorgrade,asperdetaileddrawings,conformingtoI.S.:2202- 1962(Revised)withapprovedfaceveneersonbothfaceswith/withoutglazingand venetiansinthepositionsshownonthedrawingsorasdirected,allnecessarybeads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing withfrench-polish/waxingcomplete.(withoutdoorframe).(Sampletobegotapproved from Ex.Engineer before use) Commercial Hard Wood shutter |
| 85 | First Floor |
| 86 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ Sqm asperdrawing including fixtures,necessarywelding andpainting with one coatsof anticorrosive paint and two coats of oil painting complete. |
| 87 | First Floor |
| 88 | ProvidingandFixing30MMthickBOTHSIDEPRELAMINATEDSOLIDPANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coatofmetelprimerof approvedmake andmanufacture. M.Sframe shall becovered withheatmouledPVC\"C\"channelmadefrom5mm(+/0.25)thick prelaminatedsheetofdensity 600Kilogram/cbm ,ofsize30mm thickness70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and5 mm thick ,95mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30mmPVCsheetbeadingoneithersideandjoinedtogetherwithsolventcement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3nos M.S.powder coatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares |
| 89 | First Floor |
| 90 | Providingandfixing900mmhighS.S.304GradeStainlesssteelrailingwith40mm diameter and1.5mmthickattop, 40mm diameterand1.5mm thickverticalsupports spaced at 1.5mcenter to center and 8mm thicktoughened glassincluding fabricating ,fixtures, errecting ,necessarywelding,grinding,finishing,buffingto stainless steel pipe etc. complete |
| 91 | First Floor |
| 92 | Providingandfixingonwalls/ceiling/floor15mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 93 | First Floor |
| 94 | Providingand fixingon walls/ceiling/floor20 mmdia. CPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 95 | First Floor |
| 96 | Providingandfixingonwalls/ceiling/floor25mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 97 | First Floor |
| 98 | Providingandfixingonwalls/ceiling/floor32mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 99 | First Floor |
| 100 | Providingandfixingonwalls/ceiling/floor50mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. |
| 101 | First Floor |
| 102 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete |
| 103 | First Floor |
| 104 | ProvidingandfixingC.P.wall mixerwithprovisionfor overheadshower with115mm long bendpipeandwallflangeofapprovedmakeincludingnecessarysockets/union nutetc.complete. |
| 105 | First Floor |
| 106 | Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece of C.I. pipe upto the outside face of the wall complete. |
| 107 | First Floor |
| 108 | Providingand fixingGlass self125 mmwideand 600 mmlongwith necessary chromium plated brackets providing T.W.gutties etc. complete |
| 109 | First Floor |
| 110 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpieceofUPVCpipeuptotheoutsidefaceofwall,making thegood damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) |
| 111 | First Floor |
| 112 | Providingand fixing15cm x10cm saltglazed stonewaregully trapin cementconcrete 1:4:8outsidethebuildingincludingcastirongratinginthesink,connectingglazed stonewarepipe,brickmasonry chamberwithcastironlidandcastirongratingforthegully trap. |
| 113 | Providing and constructing Brick MasonryInspection Chamber 90cm x 45cm x 90cmincluding 1:4:8 cement concrete foundation 1:2:4 cement concrete channels halfround G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. |
| 114 | ProvidingandconstructingDuctileIroncircularmanhole45cmdia.Attop90cmat bottom up to 1.80 meter to 2.70 meter depthincluding excavation,laying 1:4:8cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125Kilograminweight.Highstrength.MorelifeandDurability,GoodAntiskidGrip, Suitable to heavy theatric loading, Light weight casting after cost benefits for TransportationRefillingetc.asperrequirement.withpriorapprovalofconcernedSuperitending Engineer. |
| 115 | Providingandfixing in position UPVC ultra violetstabilized 110mm outerdiameter cowldomeconfirmingtoI.S.-4985includingmakingjointswithsolventcementetc.complete |
| 116 | Providing and fixing European type wall-hung white water closet of approved make withpushvalveconcealedtypewithcoverplate32mmsizeofapprovedmake includingsoilpipe,vent pipe up to outside face of wall ,100mm dia. G.I. plug bendinletpipeallfittings, cuttingand making good walls, floors etc. complete. |
| 117 | First Floor |
| 118 | ProvidingandfixingC.P.BIBcockwithwallflangeofapprovedmakeincluding necessary sockets/ union nut etc. complete. |
| 119 | First Floor |
| 120 | ProvidingandfixingC.P.Angularstopclockwithwallflangeofapprovedmake continental including necessary sockets/union nut etc. complete. |
| 121 | First Floor |
| 122 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 123 | First Floor |
| 124 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 125 | First Floor |
| 126 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 127 | First Floor |
| 128 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. |
| 129 | First Floor |
| 130 | Providingandfixing100mmdia.chromiumplatedbrassshowersroseto15mmdia. supply pipe including necessary bend and socket complete. |
| 131 | First Floor |
| 132 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and havingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992including proper rainwaterreceivingrecesswithP.V.C.plug,bend,necessaryfittings,suchas, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and Each,filing the joint using rubber gasket withsolvent cementandproperlyrestingtheshoe ofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 133 | First Floor |
| 134 | Providingandfixing75mmdiastabiliserpipe/P.V.C.soilvent/wastepipeand withnecessaryfixturesand fittingsuchasbends,tees,singlejunctions,slottedvent,clamps etc. complete |
| 135 | First Floor |
| 136 | Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwithnecessaryfixturesand fittingsuchasbends,tees,singlejunctions,slottedvent, clamps etc. complete. |
| 137 | First Floor |
| 138 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and ofspecialcolourshadehavingtelephonicblack/colouredgraniteof180mm thickstone blackkadappaframeworkincludingchromiumplatedcouplingbottle- TrapusingCERA companyorequivalentovaltypawashbasinmodelno 3448as perdetaileddrawing oras directed by engg incharge etc complete. (Counter size 1.20 mx 0.60 m ) |
| 139 | First Floor |
| 140 | Grabbars-ProvidingSSgrabbarssetforaccessibletoiletscomprisingof4nos.Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS)Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm oftherovedbrandandmake.27b)LShapedgrabbar(1NOS)ProvidingS.S.304L SHAPEDDISABLEDGRABBAR ofIZE-600MM(H)X 600MM(D)and32MMDIA. and thicknessmm of the approved brand and make.27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. |
| 141 | First Floor |
| 142 | Providing and fixing Mirrors of approved Indian quality, copper plated with 10 mm (3/8\") thick ply wood backing, in the masonaryas per Architect.s drawing and make approved as Directed by Engineer-in-charge etc. complete. |
| 143 | First Floor |
| 144 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approvedmakeandCementin1: 2proportion(1litrepolymer: 2Kg.Cement)toa neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10x10specificationofapprovedmakeovertackysurfaceoffirstcoatofpolymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protectivemechanicalcoverwaterproofplaster20mmthickaftersufficientcuring applyIPS40mmto75mm.thickcementconcreteof1:2:3proportionusingcoarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete,inpannelsof3m/4moraspersitecondition&fillingthejointswithpoly sulphide sealant after curing including providing holler with drip moulds at the junction and finishingthe concrete surfacewith neatcement slurry,as directedand pondingthe surfaceas directedetc.complete ;covering 10years guaranteeagainstleakproofnesson court Fee stamp paper of Rs 100/- First Floor |
| 145 | ProvidingwaterproofinginW.C.andbathincludingbrickbatcobainallposition includingproviding and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab withwaterproofingcompound@1Kilogram/perbagofcementlaying brickbatcobaof requiredthicknessincm1:5 with waterproofingcompound 1 Kilogram/bagof cementgroutingandfinishingthetoplayerwith20mmthickbrick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. |
| 146 | First Floor |
| 147 | Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 50mmthickwith3mmdiametermildsteel barreinforcement,ofapproveddesignon both side, fixing in cement mortar 1:3 and curing etc. complete |
| 148 | First Floor |
| 149 | a)DoorFrame:Supplying framesforFireresistantdoorshutters1stclassMalaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicalsinvacuum impregnationvessel under160 psipressure asper IS:401andkiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 mm spray quoted with2coatsofintumescentpaintofminimum200micron,withsinglerowofBrush- TypeASTROFLAMEintumescentstripofsize10mm x4mm affixedin theslit ofthe Frame for fire and smoke sealing, etc. complete. |
| 150 | First Floor |
| 151 | b)Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smokecheckAccousticDoorShutterwithflameguardof120minutesIS3614part-II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardantchemicalsinpressureimpregnationvesselsunder160PSIpressureasper IS:401andkilnseasonedtomoisturebelow15%asperIS:1141 framework of100x32 mm with32mm thickinfill ofceramicfiber(density 128Kilograms/CMT),vermaculite mixfacedwith6mmFireretardantHighDensityply,internallylippedwithhardwood beading,andpastedinHydraulicPressunder50tonnespressure,sprayquotedwith2 coatsofIntumescentpaintofminimum200micron,andwith1rowofBrush-Type Astroflame®intumescentstrip(imported)ofsize10mmx4mmconcealedforfireand smokesealinginthegroovesintheshutteronalledgesexceptbottom,withoutanyexternal lipping. |
| 152 | First Floor |
| 153 | c) Vision Panel:1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside theshutterstructurewith10mminsidetheshutteronallsideswithU-glazing.An additionalinsulatedpowdercoated\"Z\"channelof16swgMSsheettobefixedfor reinforcementofthejoints.Withclearfireresistantglasspanes11mmthickhavingminimum 120 minutes fire Description |
| 154 | First Floor |
| 155 | Providing andfixinginpositionGypsum boardfalseceilingwith 12.5mm thick Gypsumboards,screwed/fixed to the under structure of suspended G.I. Grid constructedand suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum centertocenterdistanceof600milimetreperimeterchanneland intermediate channels atmaximum center to center distance 1200 milimetre galvanizedgridshouldbefixedto reinforced cement concrete slab. The gypsum board shouldbefixedtogalvanizedirongridwithnecessaryscrews. Theboardsshouldbetaped and filled from underside to give smooth, seamless ceiling.The rateshould include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed inall respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 156 | First Floor |
| 157 | Providingandfixing15mmthickeco-friendlydensifiededgecalciumsilicatefalse ceilingof approved texture of size 595mm x 595mm in truehorizontallevel, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at@12gm/sq.mincludingbothsides) consistingofmainTrunnersuitably spaced atjointstogetrequiredlengthandsize24X38mm.madefrom0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross Tof size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeterwallangleprecoated steelofsize24x24x3000madeof0.4mmthick (minimum) sheet withthe help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspendedfromceilingwithusingG.I.slottedcleatsofsize25x35x1.6mmfixedto ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center tocenteralongmainTbottomexposedwith24mmof all T-sections shall be prepaintedwithpolyesterbakedpaint,forallheights,asper specifications, drawings etc. complete.(currently this item should be used only for VIP cabins) |
| 158 | First Floor |
| 159 | Providing Stampping polymer modified wall Plastering material to vertical surfaces,Wall plastering is premixed with Water and Bonding agents ( 2.5 kg mortor with ratio 1:5 mixed with 1kg polymer material) on the wall over Rough Plastered Wall in thickness of Approx. 10-12mm finalized with prescribed colour and stamping pattern as directed by Engineer Incharge. Providing and applying Acrylic polymer Sealer coat to the stamped area including removing Acid and Dust with water jet if required, after curing applying first coat of sealer using either spray pump, brush or roller @ 80 sqft per Ltr. After complete drying of first coat. Applying second coat @ 80 sq ft per Ltr , Allowing to dry for at least 4 hours etc. Including labour, fixing material, scaffolding etc. Job complete |
| 160 | First Floor |
| 161 | Providing and fixing in position structural glazing consisting of main frame of powder coated Jindal or equivalent make aluminium curtion wall section 48 X 64 mm & sub frame of 25 X 25 X 2 mm powder coated aluminium SHS by using Structrual silicon of Dow Corning 995, weather silicon Dow Corning 785, Spacer tape 6mm X 6mm including five star rated toughenedglass along will all Labour , Material etc complete. |
| 162 | First Floor |
| 163 | Providingandfabricatingstructuralsteelworkinrolledsectionslikejoists,channels, angles,tees etc. as per detailed design and drawings or as directed including cutting, fabricating,hoisting, erecting, fixing in position making riveted / bolted/welded connections withoutconnectingplates,bracesetc.and includingonecoatof anticorrosive paint andover ittwo coats of oil painting of approved quality and shadeetc. complete. |
| 164 | First Floor |
| 165 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsoras directed including cutting,fabricating, hoisting,erecting fixingin position, Making riveted/ bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
| 166 | First Floor |
| 167 | Providing,fabricatinganderecting atsiteofworkthetubularsteelstructure(shed) asper standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundationbolts, base plates,nutsandbolts, welding wherever required etc.as per detailed drawing inclusiveofonecoatof anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Each : As directed by Engineer-in-charge. |
| 168 | First Floor |
| 169 | Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesin square, rectanular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. |
| 170 | First Floor |
| 171 | Providing and applying Texture plaster with finishing with texture materialof approved makein 3 to 4 millimeterthickness on previously plastered surface, including PlasterGroove6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. |
| 172 | First Floor |
| 173 | Providingandfixing C.P.2WayBIBcockwith wallflange ofapprovedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 174 | First Floor |
| 175 | Providingandfixing sinkcockwithregularswingingspout(Wall/floorMounted Model) with wall flange having flow rate up to6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalentmake incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) |
| 176 | Providing and laying Cast in situ/ReadyMix cement concrete in M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering,formwork,coverblocks,laying/pumping, compactingandroughening them if special finish istobeprovidedandcuringcomplete.(Excluding reinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLC withSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 177 | First Floor |
| 178 | Providing andlaying intrenches50mm dia.medium gradehaving embossedasISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint,2coatsIncludingremovingexistingpipelineifnecessary and conveyingand stacking the same in PWD chowky or as directed etc. complete |
| 179 | Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. |
| 180 | Providing and fixing of Tensile Membrane Steel structure Roofing made up of Q235B & Q345 class steel structure be prefabricated of web plates of 6 to 32mm thickness, wing plates of 6 to 40mm thickness, main frame should made up of Q235B class steel beam, C and Z section steel purlin, roof of made of sandwich panel panels or of polyfluroethylen (PTFE) glass cloth with propoer insulation, Roofing structure should have 50 year of life durability should be withstand to strong wind, seismic impact and bear heavy snow as directed by engineer in charges complete. |
| 181 | Providing and fixing of Tensile Membrane Steel structure Roofing made up of Q235B & Q345 class steel structure be prefabricated of web plates of 6 to 32mm thickness, wing plates of 6 to 40mm thickness, main frame should made up of Q235B class steel beam, C and Z section steel purlin, roof of made of sandwich panel panels or of polyfluroethylen (PTFE) glass cloth with propoer insulation, Roofing structure should have 50 year of life durability should be withstand to strong wind, seismic impact and bear heavy snow as directed by engineer in charges complete. |
| 182 | Providing & fixing the Roofing Shingles of Saint- Gobain make composites of reinforced fiber glass and minerals stabilized, high grade asphalt. They are overlaid with high strength ceramic coated granules, below which is mineral stabilizer cum fibre retardant coating. The entire composition comes in the form of mats. A sheet of singles has thickness of 8mm to 9mm and size as per the requirement. The profile pattern & colour shall be as per approval drawing and it should be got approved before fixing from the Engineer in charge/Architect. The roofing should be 100% water proof and resistance of all impact forces wind & fire also unbreakable. These are maintance free contractor has to exercise given minimum 25 year warranty band on the Rs. 500 Stamp paper if any damage free repair should have been done by the contractor. The shingles should be laid on R.C.C plain slabs/ slopping. The roof subtract that it can be include steep slopes fixing of singles including starter of size 4’ x 4” and fixed by sufficient rust free nails if required silicon shall be used on the existing concrete roof including transportation, scaffolding, lifting all material etc. as directed by Engineer in charge/ Architect etc. complete. |
| 183 | Providing & fixing tera felt APP( Atactic Poly-prolene) Gobain make underlay membrane of approximate 2mm thick below single fixed by sufficient rust free nails on existing concrete plain/ slopping roof including all materials, transportation, labour and scaffolding etc. complete as per instructions ofengineer incharge/ Architect etc. complete. |
| 184 | Providing & fixing the Roofing Shingles of Saint- Gobain make composites of reinforced fiber glass and minerals stabilized, high grade asphalt. They are overlaid with high strength ceramic coated granules, below which is mineral stabilizer cum fibre retardant coating. The entire composition comes in the form of mats. A sheet of singles has thickness of 8mm to 9mm and size as per the requirement. The profile pattern & colour shall be as per approval drawing and it should be got approved before fixing from the Engineer in charge/Architect. The roofing should be 100% water proof and resistance of all impact forces wind & fire also unbreakable. These are maintance free contractor has to exercise given minimum 25 year warranty band on the Rs. 500 Stamp paper if any damage free repair should have been done by the contractor. The shingles should be laid on R.C.C plain slabs/ slopping. The roof subtract that it can be include steep slopes fixing of singles including starter of size 4’ x 4” and fixed by sufficient rust free nails if required silicon shall be used on the existing concrete roof including transportation, scaffolding, lifting all material etc. as directed by Engineer in charge/ Architect etc. complete. |
| 185 | Providing & fixing the Roofing Shingles of Saint- Gobain make composites of reinforced fiber glass and minerals stabilized, high grade asphalt. They are overlaid with high strength ceramic coated granules, below which is mineral stabilizer cum fibre retardant coating. The entire composition comes in the form of mats. A sheet of singles has thickness of 8mm to 9mm and size as per the requirement. The profile pattern & colour shall be as per approval drawing and it should be got approved before fixing from the Engineer in charge/Architect. The roofing should be 100% water proof and resistance of all impact forces wind & fire also unbreakable. These are maintance free contractor has to exercise given minimum 25 year warranty band on the Rs. 500 Stamp paper if any damage free repair should have been done by the contractor. The shingles should be laid on R.C.C plain slabs/ slopping. The roof subtract that it can be include steep slopes fixing of singles including starter of size 4’ x 4” and fixed by sufficient rust free nails if required silicon shall be used on the existing concrete roof including transportation, scaffolding, lifting all material etc. as directed by Engineer in charge/ Architect etc. complete. |
| 186 | Providing andlaying Cast insitu/ReadyMix cement concreteinM-25of trap /granite/ gneiss/ quartzite metal for R.C.C. arches with skew backs as per detailed design anddrawingsorasdirectedincludingsteelcentering,plywood/steelformwork,steel props,laying/pumping,compaction,finishingunevenandhoneycombedsurfacewithC.M.1:3ofsufficientminimumthicknesstogiveasmoothandevensurfaceor rougheningthesurfaceifspecialfinishistobeprovidedandcuringetc.complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunnybag,plastic,tarpaulinetc.(Woodencenteringwillnotbeallowed)Withfine aggregate (Crushed sand VSI Grade) |
| 187 | First Floor |
| 188 | Excavationfor roadway in earth, soil of all sorts, sand,gravel orsoft murum including dressingsectiontotherequiredgrade,camberandsideslopesandconveyingthe excavatedmaterials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed. |
| 189 | Supplyinghardmurum/kankarattheroadsite,includingconveyingandstackingcomplete. |
| 190 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 191 | Compactingthehardmurumsidewidthsincludinglayinginlayersoneachsidewith vibratory roller including artificial watering etc. complete. |
| 192 | Providing,laying, spreading and compacting stone aggregatesof specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to propergradeandcamber,applyingandbroomingrequisitetypeofscreening/binding Materialstofilluptheintersticesofcoarseaggregate,wateringandcompactingwith vibratoryrollertotherequireddensity.ByMechanicalMeans-Grading I (Using Screening Type B (11.2 mm) Aggregate) |
| 193 | Wet Mix Macadam --Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMCin mechanical mix plant carriage of mixed Material by tipper to site, laying in uniformlayerswithpaverinsub-base/basecourseonwellpreparedsurfaceand compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver. |
| 194 | StampConcreteof100mmThickness-ProvidingandLayingin-situM30Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting tositeinnagpurcity withleadupto20KM(onInnerRingRoadfrom Avastinagarto wadi),spreading,layingwithapprovedmakepover,compactedandfinishedina continousoperation, finishing to lines and grades Also Providing,Placing and applying stamppowderwhichislightfastUVresistantpigmentwithappropriatechemical compoundsofdesiredcolouronbaseconcreteafterexcessbleedwaterhasevaporated usingdry [email protected],andcoveringwithplastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1:8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approvedby Engineer-incharge orLandscape architectetc. complete.(prior approval of superinteding Engineer will be necessary ) |
| 195 | Painting Line, Dashes, Arrows etc on Roads in two coats on new work with ready mixed road marking paint confirming to I.S. 164 on Bituminous surface including cleaning the surfaceofall dirt,dustandother foreignmatter, demarcationat siteand trafficcontrol (Over/Upto cm wide) (MORTH-803) SurfaceOver 10cm Wide On New Surface |
| 196 | Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Sqmr made out of mm aluminum sheet bonded with white retro reflective sheeting ofClass ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back sideretoreflctive symbols,letters, numerals, arrow as per IRC:67-2012 Table No 8.3,supportedwith back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cementconcrete45cmx45cmx60cm,60cmbelowgroundlevelasperapproved drawing The angle iron postshall be duly painted with one coat of epoxy primer and two coatsofepoxyfinishpaintshavingalternateblackandwhitebandsof25cmwidth includingGIfixuresandtransportationetc.complete.Thenutboltsofboardwithangle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP)sheeting shall have 7 years writtenwarranty fromthemanufacturerandauthoriseddistributor/convertorissuedfor fieldperformanceincludingthescreenprintedareasandcut-outsheetingandcut-out durabletransparentoverlayfilmandthiswarrantycertificate inoriginalshouldbe submitted to the Engineer in charge by the contractor/supplier.2mm aluminum sheet Class B |
| 197 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glassbeads@250gm/sqm.Thicknessof2.5mmisexclusiveofsurfaceappliedglass beadsasperIRC35:2015.InitialDryreflectivityRLshallbe>250mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as perdirection of Engineer-in-charge and in accordance with applicable specifications.(ReferMORTHClause803fortechnicalSpecificationand Performance for IRC 35:2015). |
| 198 | Providingand laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, levelandslopeincludingnecessarycollars,excavation,laying,fixingwithcollarsin cement mortar 1:1 and refilling the trench complete. |
| 199 | Providingandlayingweepholesof100mmdiameterPVCpipesasperdrawingfor abutment returns, return walls etc. Complete. |
| 200 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete. |
| 201 | Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer)withSCADA |
| 202 | Providing and laying in situ / ready mix M-20 controlled cement concrete of trap/ granite/ quartzite/gneissmetalforRCCworkinsolid/deckslabetc.includingramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc.complete.(withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledconcretebatchmixplant/panmixerandfineagreegatesofrequired specifications ( VSI sand finely washed etc )i) Height up to 5 m, normal rate.ii) Height 5 to 7.50 m, add 5 percent extra over basic rate.iii) Height 7.50 to 10 m, 7.50 percent extra.iv) Over 10 m Height, add 10 percent extra for every 2.50m rise. |
| 203 | Providing and laying in situ cement concrete M-30 with tremix treatment for 200mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4mm wide and 20mm deep with necessary refilling with polysuphide sealent(Pouring grade) confirming to BS : 5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(excluding reinforcement) with coarsen and fine aggregate Using V.S.I.Quality Artifitial Sand etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. |
| 204 | Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. |
| 205 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. |
| 206 | Providingtocontractionjointspolysuphidesealent(Pouringgrade)confirmingtoBS: 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(appraox.25%largerthantheinitial3mOneMetricTonneo4mm.joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer.(A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide) |
| 207 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete. |
| 208 | Transporation of all types of material upto 2 km |
| 209 | Providing,Fixing of Art work madein Polyster Resin Gel Coat Chemical, casting & Moldingwith minimum 5mm thickness, along MS reinforcementwith complete finished with requiredPrimer & Dico colouras per the aesthetic of approved desgin& sizes 2\"-0\" x 3\"-0\" Ht |
| 210 | Providing,Fixing of Art work madein Polyster Resin Gel Coat Chemical, casting & Moldingwith minimum 5mm thickness, along MS reinforcementwith complete finished with requiredPrimer & Dico colouras per the aesthetic of approved desgin& sizes 2\"-6\" x 5\"-0\" Ht |
| 211 | Providing,Fixing of Art work madein Polyster Resin Gel Coat Chemical, casting & Moldingwith minimum 5mm thickness, along MS reinforcementwith complete finished with requiredPrimer & Dico colouras per the aesthetic of approved desgin& sizes. FRP Mural |
| 212 | Providing & Fixing of Customize Acrylic Art Works for Words along with MS Stand of required sizes on plate , Back lite & Acrylic Name as per design &Specification |
| 213 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a) |
| 214 | Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms. ( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b) |
| 215 | Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.14, item no 2) |
| 216 | Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7\"\" x 8\" (plants list) 1(a) serial no 15. |
| 217 | Providing on site required variety of HedgesWell Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8\"\" x 10\"(plants list) 7(b) serial no 10. |
| 218 | Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs.for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5) |
| 219 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilledlabour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) |
| 220 | Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 daysOnly (As per P&G DSR 2022-23 Items of garden work,Sr No.29) |
| 221 | Maintainance of Newly Developed ShrubsArea. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31) |
| 222 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45a) |
| 223 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b) |
| 224 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bahva (Amaltash);Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no1,item no 5C) |
| 225 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bakul;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no2,item no 5C) |
| 226 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bottle brush;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no3,item no 5C) |
| 227 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Gulmohar;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no4,item no 5C) |
| 228 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kadamb;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no5,item no 5C) |
| 229 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kanchan;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no6,item no 5C) |
| 230 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Largesstroemea ;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no7,item no 5C) |
| 231 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Arjuna ;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no3,item no 6C) |
| 232 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no4,item no 6C) |
| 233 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum Each of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no5,item no 6C) |
| 234 | Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Areca Palm ;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no1,item no 11d) |
| 235 | Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Fox tail palm;Bag Size 18 x18\"\", ht 8- 10\"(plants list sr no3,item no 11d) |
| 236 | Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) inearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12) |
| 237 | Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.22) |
| 238 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27) |
| 239 | Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35) |
| 240 | CARPET : Supplying & fixing CONDOR - SAFIER or I.T.C.- QUARTZ or equivalent make synthetic loop pile carpet of approved shade and design with 10mm thk PVC foam underlay laid as per site requirement with side edge stitching clips etc. complete as per instructions of the Architect / Engineer. 5\" X 7\" |
| 241 | First Floor |
| 242 | Providing & fixing good quality Main curtain of fabric ranging at theRmt with proper lining inside and stitching as per American plate including providing Curtain Rod hooks elastics etc. complete in all respect as directed by EIC. |
| 243 | First Floor |
| 244 | Providing ,Supplying and fixing the wall paper on walls or on ply etc of suitable size shall match the size of wall or as per the approved drawings ( joints of paper should be avoided ).The quality of wall paper should be non oven backing with mat & glossy finish.The Paper should be of German technology make and should be quality product.The wall paper and pesting material (glue) should be got approved before fixing by engineer incharge/Architect. For fixing the wall paper necessary base of wall or ply etc should be prepared ,then fix the wall paper in such a way that there should not be any air bubble or undulations seen on the surface of paperas per approved design and drawings and as directed by Engineer incharge/Architect etc complete. |
| 245 | First Floor |
| 246 | Providing and placing ( 90 cm x 60 cm)posters/portrait/painting of local and other artist to match the interior and surrouding locality including fixing and placing in position etc complete.Colour and designe approved by Engineering in charge etc complete.Specification as Directed by Engineer-in-charge etc,complete. P\P ( 90 cm x 60 cm)posters/portrait/painting |
| 247 | First Floor |
| 248 | Providing and placing ( 45 cm x 30cm)posters/portrait/painting of local and other artist to match the interior and surrouding locality including fixing and placing in position etc complete.Colour and designe approved by Engineering in charge etc complete.Specification as Directed by Engineer-in-charge etc,complete. P\P ( 90 cm x 60 cm)posters/portrait/painting |
| 249 | First Floor |
| 250 | Providing and fixing Mirror with frame, 5mm float glass of Saint Gobain with all necessary beeding , fixtures accessaries and fill up the gaps between glass and frame with sealent and as per drawing approved by Architect and as directed by Engineer in-charge. |
| 251 | First Floor |
| 252 | Designing , Itching and Buffing on glass as per drawing approved by Architect and as directed by Engineer incharge. |
| 253 | First Floor |
| 254 | Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminatepanels above the fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete |
| 255 | First Floor |
| 256 | Providing and fixing Shandelier JES-CHR-CHL0006RPE146LT Smoky Glass with Crystal ,Lamp:-E-14 LED4W x 6 of Size:-Depth 700 mm , Height 1300 mmwith necessary scaffolding as per design approved by Architect |
| 257 | SOFA: Provide sofa made of 600mm X 1500mm C.P.T.Wood frame work along with 6mm thk marine Ply for arms on either side.The sofa shall have 225mm height vertical type spring shall be fixed with thick nylon thread for the seat along with 100mm thk MM foam for seat, 75mm thk MM foam for back, 50mm thk MM foam for back, 50mm thk MM foam for handles with covering mix pieces of foam should be spread over the individual seat to have comfort along with approved make upholstery shall be used in wrinkle type design as a finishing material etc. complete as per detail drawing and instructions of the Architect / Engineer. (Basic Cost of Upholstery Rs.400/- Per Meter) |
| 258 | First Floor |
| 259 | CENTER TABLE (900mm X 450mm X 375mm) Providing center table in oval shape made out of 25mm dia Brush finish Stainless Steel frame work with 38mm X 38mm C.P.T.Wood frame work with Stainless Steel Stud with fixing of glass top & shelf.All exposed surfaces shall be finish with 3 coats of MELAMINE polish including 12mm thk PLAIN glass for TOP & 10mm thk FROSTED glass fixed with Brush Finish Stainless Steel Studs etc. complete as per detail drawing and instructions of Architect / Engineer. |
| 260 | First Floor |
| 261 | LOW HEIGHT CUPBOARD : Providing & Erecting low height storage 450mm to 600 mm in depth. The sides and shutters including shelves shall be made out of 50mm X 25mm C.P.T.Wood frame covered 6mm thick marine ply. The back shall have 12mm thick marine ply.The shutter shall be finish with approved color 1.5mm thick laminate.(Vertical Storage - Laminate Finish), but the top, sides, shutters, shelves shall be made out of 19mm thk marine ply with necessary 50mm X 50mm C.P.T.Wood frame work with laminate / veneer finish etc. complete.All exposed surfaces shall have approved color/ malamine finish,1.5mm thk laminate and matching color ZINC OXIDE polish for internal surfaces etc. complete as per instructions of the Architect/Engineer.(Note :- The furniture may be tailor made or customised as per the space available and should be executed as per the instructions of Engineer In Charge) |
| 262 | First Floor |
| 263 | WARDROBE : Providing and fixing in position 600mm deep Wardrobe units (1.7x2.1x0.6) along the partitions/wall as indicated in drawings.Storage unit shall be made out of 19mm thick plywood for sides, top and bottom.Shutters shall be made out of 19mm thick plywood finished with Laminate as per profile externally and 0.8mm thick Laminate from inside.All shutter to be provided with cup hinges of approved make as per drawing.Inside top & bottom ledges, sides and intermediate divider\"s shelves and all internal exposed sides shall be finished with 0.8 mm thick Laminate & 1mm thick Laminate for all external top and sides.Rate quoted for the item shall include for cost of 19 mm thick plywood shelves including wooden beading, hardwares such as ball catches, locks, handles etc. Item to be completed in all respects as per drawings, specifications & instructions from Consultant. |
| 264 | First Floor |
| 265 | Providing and fixing in possition luggage rack of size 1.70 x 0.6 x0.75 as per the approved drawings made in waterproof,antetermite treatment plywood of thickness 18mm with both side laminate finishas per the approved colour and design by Architect/Engineer incharge including fixing necessary accessaries polishing etc.complete. |
| 266 | First Floor |
| 267 | STUDY TABLE: Providing and constructing study table of size as directed with chair, table top, table edge, support, wire management,storages and all other accessories etc as per detailed drawings given by architects etc. complete. Laminate / veeneer finish painting/ malamine finish etc complete. (Note :- The furniture may be tailor made or customised as per the space available and should be executed as per the instructions of Engineer In Charge) |
| 268 | First Floor |
| 269 | ATTENDENT TABLE WITH SIDE TABLE Table Size: - 1650mm X 600mm X 750mmSide Table Size: - 900mm X 375mm X 750mm Providing & Fixing reception table with side table made out of 19mm thk marine ply frame work for top, sides, front apron, drawer box, shelves, key board along with 12mm thk marine ply for drawer side, step design for apron & 6mm thick marine ply for drawer bottom, back sides & curve shape etc. complete.The reception table & side table shall have approved color 18mm thk GRANITE slab for top with necessary edge MOULDING including 12mm thk PLAIN glass with ACID effect etc. complete. (Basic Cost Of Granite Rs.1830/- Per SMT)All exposed surfaces shall have approved color 1.5mm thk laminate along with METALLIC sheet for round shape & 2mm thk M.S. perforated powder coated sheet for apron fixed with Patch Fitting and inside shall have laminate matching color ZINC OXIDE polish including approved make Hardware such as Twin Telescopic Sliding Channels, Wire Manager, Approved Handles, Box Type Hinges,12mm thk marine ply wood 600mm X 450mm X 225mm height slope type Foot Rest finish with Rubber Mat finish, Powder coated CPU Trolley etc. complete as per detail drawing & instructions of the Architect / Engineer. |
| 270 | First Floor |
| 271 | Office table (1200X750x750mm) Top work surface shall be 12mm thick toughen glass with back painted design on to underside and crystal edge polished finished. The construction shall be knock down .Construction- The understructure shall have all pannels made from 36mm thick prelaminated board (Antitermide and Waterproof )with 2mm thick PVC edge beading ,understructure also consist of storage for CPU ,projector and paper .Storage- Provision for glass adjustment for glass alligning .The wire management shall have legend electricals use for wireon to center support beam panel and CPU storage area for socket connections , RJ11,RJ45 etc. colour and design approved by Engineering incharge complete. |
| 272 | First Floor |
| 273 | Providing and placing in position Side Tableatinside cottage made with pitch wood polished with melamine polish of approved shade with 10mm thk. clear glass top of size 600 X 600 X 330 )as per Architects drawing and Make approved as Directed by Engineer-in-charge etc,complete. |
| 274 | First Floor |
| 275 | Providing and fixing Consilled Door closer of Godrej make in possition including all necessry acessaries as per design approved by Architecr/ engineer in-charge etc. complete. |
| 276 | First Floor |
| 277 | Bain marie - Self Service Counters size of 20\"-0\" x 4\"-6\" with Hot/Cold Bain Marie, Hot Case, Tray Rail, Sneeze Guards with add ons like Neutral Counters, Plate Stacking Tables, Trolleys, Cutlery Trays, etc. Pick Up Counters with Hot/Cold Bain Marie, Hot Case, U/S, O/S, Under/Above Counter Cupboards, with add ons like Plate Racks, Neutral Counters, Trolleys, etc.as per detail drawing given by architects The SS to be used should be of 304 grade |
| 278 | Kitchen Trolly - Providing and supplying a huge variety of kitchen Trolleys. These are widely used for various purposes such as for carrying food, utensils and waste & garbage. Trolleys includes platform trolley, plate trolley, garbage trolley, masala trolley, cage trolley and many others. The SS to be used should be of 304 grade |
| 279 | STAINLESS STELL DUSTBINS (BRUSH STEEL) Providing & supplying stainless steel dust bins of 225mm diameter x 22 guge perforated sheet with plain border of 50mm on top & bottom. The bottom surafce shall be flat with round borders. The height of dustbins is 450mm. |
| 280 | First Floor |
| 281 | Providing and supplying Bathroom & Toilet Assessories like 17 liter Buckets, 2 liter Mug,dust bin , bathroom broom, etc. in bathrooms as per Architects drawing and approved Makeas Directed by Engineer-in-charge etc,complete. |
| 282 | First Floor |
| 283 | Providing and supplying good quality cotton Turkish type (Face Towel) napkins. Of size 405 mm x405 mm of approved colour and quality as directed by engineer in charge et. Complete.Specification as Directed by Engineer-in-charge etc,complete. P\S good quality cotton Turkish type (Face Towel) napkins |
| 284 | First Floor |
| 285 | DRESSING TABLE WITH SEATTY TABLE: Providing and fixing Dressing table of size Depth - 450.0 mm Width - 450.0 mm Height - 1710.0 mm as directed with seatty including table top, table edge, support,storages and all other accessories etc as per detailed drawings given by architects etc. complete. Laminate / veeneer finish painting/ malamine finish etc complete. (Note :- The furniture may be tailor made or customised as per the space available and should be executed as per the instructions of Engineer In Charge) |
| 286 | First Floor |
| 287 | Dining Table With Chairs - 1.200 m x 1.200 m dining table with four nos. Of sofa chairs Leather FinishDo as above item ( Sofa - leathre finish), but sofa chairs shall have 500mm wide with both side handles etc.complete as per instruction of the Architect/Engineer. |
| 288 | Providing and fixing in position First-aid box with first aid chart printed on the box with all first aid medicines such as sterilised dressings, antiseptic solutions, oinment for burn, crocin, first aid bookletas per Architects drawing and approved Make as Directed by Engineer-in-charge etc,complete. |
| 289 | Supplying and installing Office Signages of Size 4\" x 6\" Glass/SS with Vinyl as per Rooms cabin (Fire escape and Route prolite signages)as per Architects drawing and approved as Directed by Engineer-in-charge etc,complete. |
| 290 | Providing and installing automatic Coffee maker including all acessaries such as cable , socket .etc complete.(Black & Decker DCM 80 12 Cup Coffee Make) etc.Specification as Directed by Engineer-in-charge etc,complete. |
| 291 | Providing, installing and commissioning dry-wet type and dry type vacuum cleaners of capacity 500 liter of Eureca Forbes/ Samsung. (Eureka forbes trendy wet & Dry) including cable and other required tools etc. complete.Specification as Directed by Engineer-in-charge etc,complete. |
| 292 | Providing, installing hot tea pot/ kittle with the cords of IS specification including all necessary electrical connections such as , plug , sockets, buttons, cables etc. complety (Havells Vetro 1.7L Kettle (Silver).Specification as Directed by Engineer-in-charge etc,complete. |
| 293 | Providing, installingelectronic mosquito machines complete. Specification as Directed by Engineer-in-charge etc,complete. |
| 294 | First Floor |
| 295 | Providing and installing quartz type wall clocks as per color combination ofinterior with duracell battries of make Ajanta/ equivalent make base price not less than 1000.00 .including necessary hanging arrangement on wall etc. completeas per instruction of Engineer- in Charge.Specification as Directed by Engineer-in-charge etc,complete. |
| 296 | First Floor |
| 297 | Reception chair - High back chair in fabric.◆Double ply back with 3D bend and high density foam on back with mould seat◆Fabric upholstery on seat and back◆Back tilt mechanism◆Gas lift height adjustment◆Fixed PP arms◆Five prong fiber base with nylon castors for all floorings. |
| 298 | Visitor Chair - Medium back chair in fabric.◆Double ply back with 3D bend and high density foam on back with mould seat◆Fabric upholstery on seat and back◆Back tilt maechanism◆Gas lift height adjustment◆Fixed PP arms◆Five prong fiber base with nylon castors for all floorings. |
| 299 | Providing and supplying decorative indoor plants with decorative pot etc complete |
| 300 | Providing & Fixing of FREE STANDINGKing size Bed made in ply and mica of choice size is 2000 x 1800 x 400 Mm. Height Including 100 MM. Thick Matters, with Bed Back with Cusion and with bed sheets Design given by Engineer Incharge, With including side table size is - 450 x 400 D x 500 high. both side, As per furniture Layoutas per design and drawing and instructions of Engineer in charge.. |
| 301 | First Floor |
| 302 | Providing & Fixing of FREE STANDING Single bed made up of 18 mm ply and mica of choice Bed size is 2000 x 900 x 400 Mt. Height Including 100 MM. Thick Matters, with Bed Back with Cusion Design given by Engineer Incharge, With including side table size is - 450 x 400 D x 500 high. Single Sideonly , As per furniture Layout.as per design and drawing and instructions of Engineer in charge. |
| 303 | First Floor |
| 304 | Providing & Fixing of FREE STANDING Bed side tables made in 18 ply and mica of choice size is 450 x 450 x 400 Mm. Height with one drawer. As per furniture Layout.as per design and drawing and instructions of Engineer in charge. |
| 305 | First Floor |
| 306 | Providing and fixing of Cafeteria Rectangular Table size is 1200 x 750 x 750 mt. High, 4 - Seater with chairs attached to Base, Table top made up of 304ss 1.4mm thick sheet. Under structure made up of 202 S.S. Pipe supported with specially design casted connecting blocks to connect cross members with legs, Vertical member made up of M.S. Sq. Pipe 50x50x 1.6 mm thick and all horizontal members from S.S. Sq. Pipe 50x25x1.2 mm. Thick.Under Structure is Buffed with proper mirror finish as per engineer inchage. with chairs on same finsh |
| 307 | Providing and fixing in position reception table 2400X900X750/1100 MM made up of 25 mm thick prelam board top both side laminated. 18 mm prelam side panels, front panel, vertical panel, 2 drawer, 2 shutter, bottom panel, shelf in with pvc lipping. 9 mm thick prelam board at the bottom including neccessary channel, hinges, lock and handleetc. complete.as per aproved shade colour. 8mm Frosted glass on top. Dual shade lamination in Modesty & Gable ends. Table top, modesty panel, gable end, Back side Storage are in Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits.PPB Confirms to IS:12823 GRADE & Complies to free formaldehyde content (IS: 13745:1993). Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness.as per design and drawing and instructions of Engineer in charge. Aproved Make :NLF, Herman Miller,Steel case. |
| 308 | First Floor |
| 309 | Modular Conference System MAX CONFERENCE TABLE @ 6425L x 2265D x 750HTone seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge. Aproved Make :NLF, Herman Miller,Steel case. |
| 310 | Providing and fixing of wooden center table of size (1200 mm length x 600mm width x 400/450 mm high) or equivqlent size or as per design, table top made with 18/19 mm BWR plywood and finish with 4mm thick decorative veneer or table top frame made with first class quality seasoned teak / sheesham wood frame of size40 mm x 80 mm finished and 8 mm thick bevelled edge table top glass and legs of the table made with first class best quality seasoned teak / sheesham wood as per detaildrawing. Allwooden & veneer surfaces shall be dullymelamine polished. All work shall be carried out as per detail drawing and instruction of Architect/Engineer-in-charge.Aproved Make :NLF, Herman Miller,Steel case. |
| 311 | High Back Mesh Chair with Synchro 1 Mechanism with adjustable lumbar support. One dimensional height adjustable PU arm rest. Ply moulded seat upholstered with fabric. Seat is designed with waterfall edges for smooth blood circulation in legs. chair assembly is mounted on Class-IV gas lift having Nylon base and 55mm Nylon castors. Aproved Make :NLF, Herman Miller,Steel case. |
| 312 | Medium Back Mesh Chair with Synchro 1 Mechanism with adjustable lumbar support. One dimensional height adjustable PU arm rest. Ply moulded seat upholstered with fabric. Seat is designed with waterfall edges for smooth blood circulation in legs. chair assembly is mounted on Class-IV gas lift having Nylon base and 55mm Nylon castors.Aproved Make :NLF, Herman Miller,Steel case. |
| 313 | Medium Back Mesh Chair with Synchro 1 Mechanism with lumbar support. Fixed PP arm rest. Seat is designed with waterfall edges for smooth blood circulation in legs. chair assembly is mounted on Class-IV gas lift having Nylon base and 55mm Nylon castors.Aproved Make :NLF, Herman Miller,Steel case. |
| 314 | Providing and fixing Floor Master / Carus roll form carpet.The carpets manufacturing technique Gauge -1/8 C. Pile Composition-100% PA Luxus 2-ply. Primery backing should be Woven.The carpets Secondary backing should be Premiumback.Pile Weight should be 750 g/m². Each of Tufts of carpet should be 138582 /m².It Should have the following Specifications - 1. Total Height - ISO 1765 - 09 mm.2. Pile In/Out - In3. Fire Behaviour - Cfl-S14. Total Weight - ISO 8543 - 1379 g/m².stairs should be finish bystairnose with steel corner/L profile/angle.Approved Makes - Shanhua/Mohakw/Carus/Floor Master |
| 315 | Providing and fixing of Anutone Subtex Hush acoustical panels, hardened square edge, FR grade Hush fabric (colour choice) wrapped on encapsulated Glassfibre core panels of size 600x1200x25mm or , volume density 100Kgs/m3, weight 2.5kg/m2 installed by using Anutone Strut Impale Clips. Anutone Strut Impale Clips are attached are attached directly to the wall/frame work with the points extending outward and such that the spikes are truly horizontal. The spikes are tipped with Stick S7 adhesive. Then the panels are positioned and pressed into place.Technical Parameters • Fire (Class) – 1 & P • Acoustics – NRC Upto 0.9 • Thermal conductivity (W/mk) – 0.07 • Climate (°C, RH) – 40,95 • Light (%) – Colour dependent • Green (VoC, RC%) – Low, 35 All complete as per detail drawing, as specified and as directed by Architect Inclusive of all material, labour, transport, leads, lifts & shifts etc. APPROVED MAKE : Hunter Douglas, Anutone, NLF Accoustic |
| 316 | Providing and fixing of Anutone Slats - made out of pinewood fibreboards, perforated wooden grooved slats L8-2 - (2mm grooves @ 8mm centers) / L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centres) /L64-2 - (2mm grooves @ 64mm centers), backlined with acoustical fleece, tongue-groove edge for a seamless look, of lineal dimension size 128mm x 2440mm x 16mm thick having density 800Kg /m3, weight 10 Kgs/m2, installed by using wall Panelling system. The wall panelling system shall includes GI Wall channel(WC25) having thickness 0.45mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm to be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Main channels(MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at every 1200mm centers with Suspender angle (SA25) having thickness 0.45mm, length 3600mm, unequal flanges of 25 & 10mm. GI Cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web of 50mm, depth of 25mm and equal flanges of 9.5mm is fastened to the Main channel (MC45) in the direction perpendicular to the Main Channel(MC45) at every 600mm centers. Aluminium core cross channel (CC18) having 0.5mm thick, 15mm & 27mm width, height 18mm, flanges of 7mm and length 2500mm is then fixed to the Cross channel (CC25) with the help of metal fasteners in direction perpendicular to the cross Channel at every 400mm centers. Slats of size 128mm x 2430mm x 16mm thick in then fixed perpendicular to CC18 with suitable edge & centre brackets. • Core -Fibreboard• Acoustics – NRC up to 0.75• Climate (OC RH) – 50, 70• Light reflectance – 75%• Green (RC %) – 25• Hygiene (VoC, Clean room) – Low, Class 1• Strength, Load capacity (Kg) - Antisag, Ball-Impact . Approved Make : Hunter Douglas, Anutone, NLF Accoustic |
| 317 | Supply & Installation of Airflex Smash approved Wooden flooring system that should be compliance with the Area elastic with totalthickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and l0mm Power Rubber Pad. Producttop finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat andsaliva resistance according to DII 53160-1/2) to have higher polish life. The wooden flooring should have Eco-friendly manufacturingprocess with 100% sustainable and manageable plantation resource with raw material. The product should have been produced throughK ilned and dried technology to maintain suitable moisture content. The top wood should necessarily be sourced from 100% sustainableresource and should have with prefinished including sanding & polishing. Structure of system should be l0mm thick rubber pad, 45 mmthick p ine runner with the width of 70mm, followed by the 20mm top flooring. Top wood plank sizes should be 20mm Thick, 130 mmWide and 1830mm length. Runners to be placed at a distance of 305mm C/C. Entire system should follow norms with the EN14904(06/2006) and technical parameters for the product should have friction of 95 according to EN 13036-4, Shock absorption of 45%according to EN 14808, Vertical deformation should be 1.8mm according to EN 14809 and Vertical ball rebound should be 99% accordingto EN 12235.” Approved Make : Ebaco, Forbo, Euroflex |
| 318 | Providing and fixing of Wall to Wall Carpet Model - ByzantiumCarpet Construction should be - Scroll Loop Pile , Fibre Compostion of carpet - 100% Solution Dyed PP , Tuft Gauge should be - 1/12′′ ,Tuft Density of carpet - 212850/SQM , Primary Backing - Woven , Pile Height - 4 MM , Total Height - 6 MM , Pile Weight - 750 GSM , TotalWeight of carpet should be - 1750 GSM , Secondary Backing - Blue Felt ,Approved Makes - Shanhua/Mohakw/Byzantium |
| 319 | Providing, Fixing Green Wall of size 1m x 1mall material, labour, fixing equipment , lead , Scaffolding and lift etc. completed. |
| 320 | Providing, Fixing Charcoal Sheet of size 8 feetx 2feet with 5mm thicknessall material, labour, fixing equipment , lead , Scaffolding and lift etc. completed. |
| 321 | Providing, Fixing Charcoal Louver of size 5 inchx 8 feet with 12mm thicknessall material, labour, fixing equipment , lead , Scaffolding and lift etc. completed. |
| 322 | METAL BAFFLE CEILING : Providing & fixingof horizontallevel suspendedceiling comprisingofVerticalLinearBaffleCeilingmadeoutofAluminumExtrusionin Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black & White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV–ATestfor1000hoursasperASTMG-154–(Cycle–1)andHumiditytestfor 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYKGardnerinstrumentandglosslevel25±5at60˚asperASTMD523(Not applicable of Wood GrainShade). Thebaffle bladeshall besuspended usingSlotted U- profileof20x30x3700mm(Thk-1.5mm)havingslotsinmoduleof25mmtokeep bafflesatanon-centerspacinginmultiplesof25mm.LongerlengthsofBaffletobe connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall behangedusingbafflehangerfromU-profilemadeofmildsteelwithpowdercoating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slotsof 6.5x6.5mm & 28x6.5mm respectively onthe webfor lockingthe bafflehanger usingplugincliptosecurethehangerinperfectpositionandachieveuniformspacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm andisrolledform from 1.5mm thickmildsteel withapowdercoatingthicknessof60- 80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturingdefectandmanufacturershall provideawarranty certificate.Thesupply shall be backed by a Manufacturing Test Certificate. |
| 323 | PRIVIDING AND FIXING ACOUSTICALFALSE CEILING WITH 0.9 NRC:SierraMineral Fibre Acoustical Suspended Ceiling System with 15mm thick Sierra OP Tegular 15/90 Edge Tiles withSuprafine 15mm face exposed grid. The tiles shall have smooth laminatedvisual withHumidity Resistance(RH)of95%,NRC0.90(Averagevalueof Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 25db as per ASTM E1414, Light Reflectance ≥86% as per ASTME-1477,ThermalConductivityλ=0.040W/mK,ColourGlobalWhite,Fire Performance of class A2-s1, d0 according to EN 13501-1 with 15mm Tegular 15/90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable and classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 43% and VOC Emissions (French) class of A+.ThetileshallhaveEnvironmentalProductDeclarationasperISO14025andEN 15804+A2. The tile shall have certifications fromGRIHAandGreenPro thereby confirmingthatitisanenvironmentfriendly product.SUSPENSION:Thetileshallbe laid onSuprafine 38 with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed doublestroke rotary stitchingonall Tsections i.e.the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). Thedeflectionloadingofthesystemshallbe12.5kg/m2(asperstandardinstallation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All mainbeam tomain beamandcrossteetocrossteeconnectionshall haveapulloutstrengthofmorethan 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. |
| 324 | ACOUSTICAL GLASS FIBREFALSE CEILING CLOUDS & SHAPES : Providing andFixing Acoustical Clouds/Shapes - Acoustical clouds which are 30 mm thick, flatglass fibre panels of Humidity ResistanceRH 95%, with embedded frame made of aluminium extruded section of38X10mm of grade 6063-T6 as per dimension mentioned in below tableforreinforcementandsecuredhanging.Embeddedextrusionshallhavegrubslot with pre inserted nut for group hanging and connected using Aluminium die casted corner connector with ¼” – 20 threading for hanging using cable adjuster for independent clouds. Theform ofAcoustical Clouds/Shapes- shall be Square/ Convex/ Concave/ Circle/ Hexagon/Trapezoid/Parallelogram(Left&Right)/Rectangle(Small&Large) in standard Traffic White color with light reflectance 90% as per ASTM 1477-98 or in the color specified by the Architect / Engineer in charge (Shell / Tangerine / Cranberry / Moss/ Kiwi / Reef / Lagoon). The Acoustical Clouds/Shapes shall be made of Glass fibre panel with density of 110-120 Kgs/m3 along with acoustical sound absorbing scrim on the face to achieve sound absorption as per below mentioned table in accordance to EN ISO 354:2003(averageof500-4000Hz).Thefaceandedgesshallbefinishedwithmatching water based texture paint. Shape Nominal Size and Sound Absorption – Metric Sabin1.Square1170x1170mm-2.48MetricSabin2.Convex1170x1140mm2.28Metric Sabin 3. Concave 1170x1140mm 1.94 Metric Sabin 4. Circle 1170 Dia. 2.12 Metric Sabin5.Hexagon1170x1010mm 1.61Metric Sabin6. Trapezoid1170x1170mm 2.15Metric Sabin7.LeftParallelogram1170x1170mm2.15MetricSabin8.RightParallelogram 1170x1170mm 2.15 Metric Sabin.The panel shall be hung as per the following based on the installation. Individual Suspension - The panel shall be hung using deck hanging kit comprising of griper structure anchor & cap of dia. 20mm, spring loaded bottom end cable adjuster of dia. 9mm and 2.4m long aircraft cable of1/16” dia. The Each of deck hanger will be as per Table 1 above. |
| 325 | Full Height Partitions in Glass finish -Providing and Fixing 80mm to 85mm thick Full heightDouble Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing. |
| 326 | Providing and fixing CCTW beading of size 40 mm x 20 mm to the door frameincludingchamfering finishing with 3 coats of oil painting etc. complete |
| 327 | Providing and supplying Turkish Type Bath Towelas per Architectsand approved as Directed by Engineer-in-charge etc,complete |
| 328 | First Floor |
| 329 | Providing ans supplying Comfater for Double & single bed of approved quality as per architects drawing and make approved as directed by Engineer-in-charge etc complete |
| 330 | First Floor |
| 331 | Providing and supplying double & single bed-sheets ,pillow covers for two pillows as per architects drawing and make approved as directed by engineer incharge etc.complete |
| 332 | First Floor |
| 333 | Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20, 000 litres |
| 334 | Providing & Fixing Including all Charges for Tapping from Municipal water Supply line etc |
| 335 | Suppying and fixing Roller blinds Curtain on windows made out of imported fibrics and rollers with level for rotic movement and stairing for side movement fitted in matching powder coated aluminium channel fixed in mannar tio insure smooth operation as per Architect.s drawing and make approved as Directed by Engineer-in-chargeetc.complete.. |
| 336 | First Floor |
| 337 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. |
| 338 | First Floor |
| 339 | Providing and applying plaster/wall punning with plaster of paris(with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface(Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete |
| 340 | First Floor |
| 341 | Providing and fixingDouble leaf glass door shutter with hydraulic door closersof 35mm thick and glass thickness 10 to 12 mm with frame, for solid core flush door,decorative type of exterior grade as per detailed drawings or as approved , all neccessary beads, moulding and lipping, brass oxidised / aluminium with powder coating fixtures and fastenings with mortise lock, chromium plated handles on both sides and finishing with french polishing etc. complete. (without frame) |
| 342 | Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate(natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate(natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate(natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate(natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern. |
| 343 | Providing & Fixing Kids play Equipment MPPS 04accessories including etc |
| 344 | Providing & Fixing Kids play Equipment MPPS 03accessories including etc |
| 345 | Providing & Fixing Kids play equipment Multi Seater Circular Swing accessories including etc |
| 346 | Providing & FixingKids play equipmentFour Seater See Sawallaccessories including etc |
| 347 | Providing & FixingKids play equipmentTwoSeater See Sawall accessories including etc |
| 348 | Providing & Fixing Cast Iron FRP Garden Benchesincluding all accessories as directed by engineer in charge. |
| 349 | Providing and fixing in position Shoppers Hub PNQ Heavy Duty Electric Kettle with Welcome Tray Set for Ideal Use in Homes and Hotel Rooms (Set Contains 1 Unit of Honeyson Branded Premium 1.2 Litres Electric Kettle & 1 Unit of ABS Fibre Based Tray with Sugar, Straw & Sachet Holder etc |
| 350 | Provinding and errecting 1.80m high Fix knot fencing Bezinal 2000 Type fencing having 16Rowsof2.40mm Bezinal 2000wireonM.S.angle 50x50x5mm embeddedin cc blockof1:4:8ofsize450x450x910mmatendandblockof450x450x760mmat intermediate,4.80m specingofpolewith\"S\" cliphighTensileBezinal 2000including pulling high tensile wire with 5 Tone capacity puller including finishing and scoat of oilpainting to M.S. angle etc. complete. |
| 351 | ProvidingandinstallingbiodigesterunitbasedonDRDOtechnologymadeoffibre reinforcedplastic(FRP)havingcompositionandfollowingtechnicalspecificationsand includingnecessary pipeandaccessoriesupto3meterlength,excludingthenecessary excavation for installing the bio digester.Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67%Water absorption (as per ASTM):-0.30% Flammability as per ASTMTensile strength:-115 MPASpecific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mmOutlet pipe size rigid PVC:-80mmGas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition)WithDRDOTOTlicenseeandlatestbatchcertificate(month&yearofsupply)and capacity as below l)Upto500usersize(6mx2.0mx1.6m),Capacity ofBiodigester:-20000liters,Areaof top, bottom and side walls: - 50.72 sq.m, Area of partition walls: 13.36sq.m, Total weight ofFRP:-917.86Kilogram,Bacteriainoculumsquantity:-7000liters,Minimum thicknessofsidewalls/topandbottom:9mm,OneEachofinsidepartitions:-4,Minimum thickness of partition wall: 4mm |
| 352 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 353 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 354 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 355 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 356 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 357 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv |
| 358 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 359 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 360 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 361 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 362 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 363 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 364 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/ inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 365 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/ inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 366 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 367 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 368 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 369 | Supplying and erecting modular type 32A, DP key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. |
| 370 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 371 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 372 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 373 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW |
| 374 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 375 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 376 | Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 377 | Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 378 | Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. |
| 379 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 380 | Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board. |
| 381 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 382 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 383 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 384 | Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. |
| 385 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 386 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 387 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 388 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 389 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 390 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 391 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 392 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 393 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 394 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 395 | Supplying and erecting LED COB Downlight with reflectorcircular Max. 8W Operating Temperature 10℃ to 40℃,Rated Input Voltage & Frequency 220-240 VAC, 50Hz,THD <15% Rated Luminous Flux 560 lm / 520 lm / 480 lm (tolerance as per BIS),Rated Luminaire Efficacy 70 lm/W / 65 lm/W / 60 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 36°, colour rendering index CRI>90, Driver Efficiency ≥80% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20, Impact protection IK02, Provided Short Circuit Protection , Open Circuit Protection, Reverse Polarity Protection Engineer incharge |
| 396 | Supplying and erecting LED COB Downlight with reflectorcircular Max. 12W Operating Temperature 10℃ to 40℃,Rated Input Voltage & Frequency 220-240 VAC, 50Hz,THD <15% Rated Luminous Flux 720 lm / 685 lm / 65 lm (tolerance as per BIS),Rated Luminaire Efficacy 60 lm/W / 57 lm/W / 55 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 30°, colour rendering index CRI>90, Driver Efficiency ≥80% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20, Impact protection IK02, Provided Short Circuit Protection , Open Circuit Protection, Reverse Polarity Protection Engineer incharge |
| 397 | Supplying and erecting LED COB Downlight with reflectorcircular Max. 15W Operating Temperature 10℃ to 40℃,Rated Input Voltage & Frequency 220-240 VAC, 50Hz,THD <15% Rated Luminous Flux 1125 lm / 1050 lm / 975 lm (tolerance as per BIS),Rated Luminaire Efficacy 75 lm/W /70 lm/W / 65 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 45°, colour rendering index CRI>90, Driver Efficiency ≥80% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20, Impact protection IK02, Provided Short Circuit Protection , Open Circuit Protection, Reverse Polarity Protection Engineer incharge |
| 398 | Supplying and erecting LED COB Downlight with reflectorcircular Max. 20W Operating Temperature 10℃ to 40, Rated Input Voltage & Frequency 230 VAC, 50Hz,THD <15% Rated Luminous Flux 1710 lm / 1620 lm / 1530 lm (tolerance as per BIS),Rated Luminaire Efficacy 95 lm/W / 90 lm/W / 85 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 38° Driver Efficiency ≥85% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20 Provided Short Circuit Protection , Open Circuit Protection ,Reverse Polarity Protection etc complete |
| 399 | Supplying and erecting LED COB with reflector Downlight circular Max. 30W Operating Temperature 10℃ to 40, Rated Input Voltage & Frequency 230 VAC, 50Hz,THD <15% Rated Luminous Flux 2850 lm / 2700 lm / 2550 lm (tolerance as per BIS),Rated Luminaire Efficacy 95 lm/W / 90 lm/W / 85 lm/W (tolerance as per BIS) Correlated Color Temperature (CCT) 6500 K / 4000 K / 3000 K (tolerance as per ANSI) Beam Angle 38° Driver Efficiency ≥85% LED Life Span >50000 Hrs Housing Die Cast Aluminium with White Powder Coating Lens / Reflector Anodized Reflector Mounting Recess Over Voltage Protection Withstand upto 440V/AC for 4 Hrs Surge Protection ±4.0KV Protection Class Class II Ingress Protection IP20 Provided Short Circuit Protection , Open Circuit Protection ,Reverse Polarity Protection etc complete |
| 400 | Supplying and errecting of high quality Static White Circular Inground LED Lighthaving precies symmetrical beam as per design or site requirement suitable for façade lighting applications. Housing to be made of die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have corrossion resistance powder coating finish and Stainless Steel (SS 316) frame on top and should have tilting arrangement. Luminaire shall be suitable to operate in a temperature range of -10°C to50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots to insure proper light distribution. Suitable for outdoor weather proof conditions having IP67 ingress protection. Toughened glass having impact resistance protection of IK09.The luminaire shall have system wattage 24W and system lumen output of not less than 1850 lumens, Beam angle should be symmetrical 15/20/36/45 degree/As per site condition, The fixture shall haveinput voltage of 240V AC with integral driver or 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \"IS 10322\" ,Color Temperature : 3000K, CRI>80, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Bridgelux to insure higher lumen output and brightness with SMD LED chips. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturere shall submit the LM79 & LM 80 report along with the supply of material along with the BIS certificate.. |
| 401 | Supplying and errecting of high quality Static White (3000K) Window Trick Light having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection.The luminaire shall have system wattage 9W and system lumen output of not less than 680 lumens, Beam angle should be narrow : 180 Degree, The fixture shall have input voltage of 240V AC with integral driver or 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ Full Load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver complying to BIS standard \"IS 10322 ,Color Temperature : 3000K CRI > 70, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia, Bridgelux to insure higher lumen output and brightness with SMD/COB LED chips. The successful bidder shall submit the product data sheets,LM80 report issued by LED manufacturer along with the BIS certificate. |
| 402 | Supplying and errecting ofLED Flexible Strip light (3000K) with IP67 rating sealed with anti-UV and anti-UV aging silicon material without color shifting. Lumen output100Lm/W, 75Watt/5Mtr.Universal PCB width for perfect installation with aluminum profile. SMD LED\"s, CRI80, 3000K, 120LEDS/M, 15W/m, 8.33mm/cut, 24V dc, 8mm white PCB, overall width 10mm after IP rated, Supply voltage 24V DC, PCB Type: 2oz white FPC, OSP, Class III for safety use, Long lifespan 50K hrs. L70B50@25℃ , High density of LED array for dot-free linear lighting performance, better color consistency for visual comfort,. Lead cable (300mm) with suitable numbers of clip, screw, end caps , mounting tracks and waterproof connector. with 3 years warranty with suitable IP67 rated drivers of branded make.. |
| 403 | Supplying & Errcting of aluminium profile sealed with anti-UV and anti-UV aging silicon material, Anodized Finish, extructed aluminium housing, size 1000x16x18 MM, slide diffuser, end caps. Etc. complete. |
| 404 | Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty. |
| 405 | Supplying, Installing, Testing & Commissioning Chandelier, rated voltage 240V AC, 50Hz, Wattage 104W, Recomonded lamp 104W LED optical, Material- Brass, Surface Finish- Gold, Plating Thickness- 0.02 um, Size (LxWxH) - 533x 533x450 mm, Weight- 18Kg, crystal available in Asfour crystal, Ingress Protection (IP)- IP20, protection Class-1 etc complete. |
| 406 | Supplying, Installing, Testing & Commissioning Chandelier, rated voltage 240V AC, 50Hz, Wattage 6*4.5W Max, cap type- 14, Material- Brass/solid glass rod, Surface Finish/Color :- Brass, Plating Thickness- 0.02 um, Size :- D650 * H1320, Weight- 8Kg, No. of Heads :- 6, Crystal :- Available Almaaza in Asfour Crystal, Ingress Protection (IP)- IP20, protection Class-1, Installation Hanging Mount etc complete. |
| 407 | Suplying & Errecing decorative bed side lamp, Rated Voltage 240V, 50 Hz, Wattage 1X40W max., Recommended Bulb 1X7W Led, Base E27, No. Of Head 1, Material Mild Steel and Glass, Surface Finish Nickel finish, Shade Opal Glass, Size (LXWXH) 165X110X270 mm, Fixture Height 270mm Protections Ingress Protection (IP) IP20 Protection Class-I Installation Wall Mounted etc. complete |
| 408 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. |
| 409 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/ watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. |
| 410 | Supplying and erecting LED Mirror Light decorative wall/ceiling mounted fixture including LED upto 12W circular/square type with opaque diffuser and electronic driver including bracket complete. |
| 411 | Supplying, Installing, Testing & Commissioning of high-quality Static White (3000K) Linear Wall Washer in 1000mm having precise beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. The luminaire shall have system wattage not exceeding 36W and system lumen output of not less than 2750 lumens, Beam angle should be 10x60 /15x45/25 Degree/As per site condition, The fixture shall haveinput voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full Load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \"IS 10322”, Colour Temperature: 3000K, CRI>80, Operating Temperature: -10°C to +50°C, Operating Humidity: 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Bridgelux to insure higher lumen output and brightness with SMD LED chips. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturer shall submit the LM79 & LM 80 report along with the supply of material along with the BIS certificate. Similar to model No. DABIN 10H1 |
| 412 | Supplying, Installing, Testing & Commissioning of 4 Way Cree Light 4X3W CL COB SPOT 4D high pressure aluminium die cast 3000 K IP 65 as per approved drawing and design or as approved by the Engineer In charge. Make: REYTEK |
| 413 | Supplying and erecting GEMA Rouund 3W LED Recess Mounted, luminier made up of cast aluminium for better thermal management with mounting clamp, pressure die cast aiuminium ring with reflector and acrylic diffuser for uniform light distribution, integrated with 3W LED, high PF constant current LED driver with surge and thermal protection, cable entries for through wiring of main supply cable, protection class IP-20, suitable for operation on 240V, 50Hz single phase AC supply, 3 Years warrenty etc complete. |
| 414 | Supplying, Installing, Testing & Commissioning PISA WALL LIGHT PROVIDED WITH SUITABLEWATTS LED LAMP, Luminaire made of die cast aluminium frame with non corrosive SS fasteners, Toughened clear Black glass diffuser, Silicon gasket, Cast aluminium base for mounting onto the wall, Surface mounting on wall using hardware after connecting to the power supply, Cable entries for through-wiring of mains supply cable, Integral power supply, Earth connection, Safety class I, Protection class IP 43, CE - Conformity mark, suitable for operation on 240V, 50Hz single phase, AC supply. |
| 415 | Supply Installation Testing & Commissioning of 550 mm Height Decorative laser cut suspended type luminaire fitting, made of Steel pipe and no fabrication from sheet metal is allowed. The luminaire should be with High Pressure Die- Cast Thermal Management for longer life of the LEDs and the IP65 optical compartment. The diffuser shall be clear Toughened Glass. The luminaire needs to have the design as shown in drawing with an bottom opening of 150mm (+/-5%). The system AC wattage of the luminaire shall be 25W (± 10%), colour rendering index CRI >/= 70 and residual flux of 70% (L70) @ 50,000 hours at Ta of 25°C. Colour temperature (CCT) of 3000K. The luminaire shall be suitable for operating within temperature range from - 10°C to + 50°C. The light source should be (Make-Osram /Bridgelux /Nichia /Cree /Lumiled) with Macadam = 5. The luminaire should be deigned to operate at any voltage from 140V to 280V, with Power Factor ≥ 0.95 and shall be provided with optional built in Over Voltage and Under Voltage protection and internal surge protection of 4/4 kV in both Common & Differential Modes. The luminaire shall comply with safety requirements of applicable BIS standard and the Bidder shall submit a copy of valid BIS certificate. Overall outer dimensions of luminaire shall be SQ150mm (±3%) and 550mm (±5%) Height and the shape shall be as per the sketch attached herewith. The offered luminaire shall be made in India with local value addition of not less than 70%, with the housing die-casted & manufactured in India. A declaration from the manufacturer on its letter head in this regard shall be submitted by the Bidder failing which the bid will be considered and non-responsive and accordingly rejected. Further, any misrepresentation in this regard will lead to rejection and blacklisting of the Company. Important: In case the Bidder proposes alternate make, it would be necessary to submit a fully functional sample of the luminaire along with the bid failing which the bid will be considered and non-responsive and rejected. The luminaire should be having a warranty for a period of 2 years against any manufacturing defects. The Manufacturer should have valid ISO 9001:2015 from CE certification. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, and Humidity Chamber. The manufacturer shall submit the LM 80 report along with the tender. Similar to REYTEK Model No. ADHARA 150mm TM 550H 15w LED 30K AL. The luminaire should be with a valid BIS Number. The decorative laser cut luminaire fitting design should be as per design approved by Architect & Engineer in Charge. |
| 416 | Supplying and erecting LED Sencer sutaible for Down light up to 18 watt 230 V AC 50 cyclescomplete erected in position as Engineer In charge |
| 417 | Supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kWh / 24 hour / 45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH |
| 418 | Providing fiber reinforced PVC flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. |
| 419 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 420 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 421 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 422 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 423 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 424 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV /trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 425 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 426 | Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 8 ways Four pole outgoing upto 100 A MCCB\"s on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB\"S) |
| 427 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete. |
| 428 | Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 429 | Supplying and erecting four pole metal clad ON LOAD change over switch 415V, 200A erected on angle iron /GI frame approved make complete. |
| 430 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 431 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 432 | Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 433 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 434 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. |
| 435 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 436 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 437 | Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8) |
| 438 | Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8) |
| 439 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. |
| 440 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 441 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 442 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 443 | Supply Installation Testing & Commissioning of 3000 mm Height Decorative laser cut Column Light, made of Steel pipe and no fabrication from sheet metal is allowed. The base plate should be as shown in the drawing. The luminaire should be with High Pressure Die-Cast Thermal Management for longer life of the LEDs and the IP 65 optical compartment. The diffuser shall be clear Toughened Glass. The pole needs to have the design as shown in drawing with an opening of 1500mm (+/-5%). The system AC wattage of the luminaire shall be 40W (± 10%), colour rendering index CRI >/= 80 and residual flux of 70% (L70) @ 50,000 hours at Ta of 25°C. Colour temperature (CCT) of 3000K. The luminaire shall be suitable for operating within temperature range from - 10°C to + 40°C. The light source should be (Make- Osram/Bridgelux/Nichia/Cree/Lumiled) with Macadam = 5. The luminaire should be deigned to operate at any voltage from 140V to 280V, with Power Factor ≥ 0.95 and shall be provided with optional built in Over Voltage and Under Voltage protection and internal surge protection of 4/4 kV in both Common & Differential Modes and external surge protection of 10 kV, electrical Class I. The luminaire shall comply with safety requirements of applicable BIS standard and the Bidder shall submit a copy of valid BIS certificate. Overall outer dimensions of luminaire shall be SQ150mm (±3%) and 3000mm (±5%) Height and the shape shall be as per the sketch attached herewith. The offered luminaire shall be made in India with local value addition of not less than 70%, with the housing die-casted & manufactured in India. A declaration from the manufacturer on its letter head in this regard shall be submitted by the Bidder failing which the bid will be considered and non-responsive and accordingly rejected. Further, any misrepresentation in this regard will lead to rejection and blacklisting of the Company. Approved makes: Schreder/Reytek/Ligman. Important: In case the Bidder proposes alternate make, it would be necessary to submit a fully functional sample of the luminaire along with the bid failing which the bid will be considered and non -responsive and rejected. The luminaire should be having a warranty for a period of 2 years against any manufacturing defects. The Manufacturer should have valid ISO 9001:2015. The manufacturer should have internal testing equipment ’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturer shall submit the LM80 report along with the tender. Similar to REYTEK Model No. Polis B 150mm CL 3000H 40w LED 30K. The luminaire should be with a valid BIS Number. The decorative laser cut columns light design should be as per design approved by Architect & Engineer in Charge. |
| 444 | Supply Installation Testing & Commissioning of 1000 mm Height Decorative laser cut Bollard, made of Steel pipe and no fabrication from sheet metal is allowed. The base plate should be as shown in the drawing.The luminaire should be with High Pressure Die- Cast Thermal Management for longer life of the LEDs and the IP65 optical compartment. The diffuser shall be clear Toughened Glass. The pole needs to have the design as shown in drawing with an opening of 450mm (+/-5%). The system AC wattage of the luminaire shall be 15W (± 10%), colour rendering index CRI >/= 80 and residual flux of 70% (L70) @ 50,000 hours at Ta of 25°C. Colour temperature (CCT) of 3000K. The luminaire shall be suitable for operating within temperature range from - 10°C to + 50°C. The light source should be (Make-Osram/Bridgelux/Nichia/Cree/Lumiled) with Macadam = 5. The luminaire should be deigned to operate at any voltage from 140V to 280V, with Power Factor ≥ 0.95 and shall be provided with optional built in Over Voltage and Under Voltage protection and internal surge protection of 4/4 kV in both Common & Differential Modes. The luminaire shall comply with safety requirements of applicable BIS standard and the Bidder shall submit a copy of valid BIS certificate. Overall outer dimensions of luminaire shall be SQ150mm (±3%) and 1000mm (±5%) Height and the shape shall be as per the sketch attached herewith. The offered luminaire shall be made in India with local value addition of not less than 70%, with the housing die-casted & manufactured in India. A declaration from the manufacturer on its letter head in this regard shall be submitted by the Bidder failing which the bid will be considered and non-responsive and accordingly rejected. Further, any misrepresentation in this regard will lead to rejection and blacklisting of the Company. Important: In case the Bidder proposes alternate make, it would be necessary to submit a fully functional sample of the luminaire along with the bid failing which the bid will be considered and non-responsive and rejected. The luminaire should be having a warranty for a period of 2 years against any manufacturing defects. The Manufacturer should have valid ISO 9001:2015 from CE certification. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturer shall submit the LM 80 report along with the tender. Similar to REYTEK Model No. Polis B 150mm BP 1000H 15w LED 30K. The luminaire should be with a valid BIS Number. The decorative laser cut Bollard design should be as per design approved by Architect & Engineer in Charge. |
| 445 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 446 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 447 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 448 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 449 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole). |
| 450 | Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 451 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 452 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 453 | Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 454 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 455 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 456 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 457 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 458 | Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 459 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete. |
| 460 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR) /Color /Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. |
| 461 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Ou× 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color /Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. |
| 462 | Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR |
| 463 | Supplying & erecting 4 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, Maximum sustained transfer rate 150MB/Sec to 180MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 64, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 464 | Supplying & erecting 43\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 465 | Supplying and FixingHD Set Top Box of TATA SKY/ Videcone etc, Approved by Engineer In Charge |
| 466 | REFRIGERATOR : Supplying refrigerator domestic type approved make 47 litres storage capacity , suitable for operation on 230/250 Volts 50 cycles complete with automatic temperature control confirming to IS specification No. 1476/79 with one year guarantee for sealed unit in refrigeration system and marking Sr.No.and date of erection. (Videocon VCP063SH-RDA Single Door 47 Litres Refrigerator) |
| 467 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 468 | Supplying, installing, testing & commissioning split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/WAC |
| 469 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. |
| 470 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. |
| 471 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. |
| 472 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. |
| 473 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA output continuous rating to CPCB IV plus emission compliant with output contineous rating, 3 phase, 415V, 50c/s, 0.8 pf, 1500 rpm with 10% overload for 1 hour in 12 hours, along with standerd accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001with voltage regulation +/-0.5% with performance class G2 both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standerd control panel, comprising meter, switchgear, indicator connected with suitable wire/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound obsorbing material to restrics sound level upto 75 DB at 1.0 m., with first filling oil, diesel tank capacity not less than 385 litres etc. on provided M-20 grade CC foundation and obtaining necessary approval from Electrical Inspector if necessary. This DG set is fitted in soundproof & weather proofAcoustic Enclosure as per CPCB-IV Plus Emmision Compliant (With Acoustic Enclosure) |
| 474 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 475 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 476 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 477 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 478 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 479 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 480 | Providing and erecting 545 to 550 Watt Framed Dual Glass Bi-Fecial Solar Module Panel Having Mechnical Cheracterics of 2272x1133x35 (LxWxT), Weight 333 KG, Front Glass 2 mm Low Iron HTAR semi-tempered glass and Back Glass 2 mm Low Iron Printed semi-tempered glass,Having Electrical Characterics of Vmp of 41-43 Volt DC, Current 13A DC, Juncton Box IP65, MC4 Cable Connector with Sq mm, 500mm Cable including in Panel Junction Box. Bifecial Power output at 30% Rediation 700W, at Module Efficiency of 27% With 5 Years of On-Site Warrenty. |
| 481 | Providing and erecting of Transformerless Solar On Grid String Inverter of suitable Capacity, Having Mechnical Cherecterics of IP65 Rating, 5 to 6 Inch Multi Information LCD Display. Electrical Characterics of 1000V DC Input Voltage, Input Power of 1200W DC, MPPT Voltage Range of 200 to 850V, Startup Voltage of 180V, Nominal Output Power 40KW AC, Output Voltage of 400V, 3Ph, 5 Wire AC(3L/N/PE), Max Output Current of 15A AC, with Powerfactor Adjustable to +0.80 to -0.80. Including all Accessories like ACDB, DCDB, Wiring, Earthing, DC & AC Cables of Appropriate sizes. |
| 482 | Supplying and erecting switch disconnector fuse (SDF) 415V, 100A, with enclosure, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V , with rotary handle for ON / OFF operation (without HRC fuse) |
| 483 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 484 | Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. |
| 485 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 486 | Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 487 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 488 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 489 | Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 100 mm diawith necessary fittings as per specification no. FF-PP |
| 490 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 491 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 492 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 493 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 494 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system |
| 495 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 496 | Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 497 | Supplying and erecting 80 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 498 | Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 499 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 500 | SSupplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 501 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 502 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 503 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 504 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 505 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 506 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 507 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 508 | Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT |
| 509 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 510 | Supplying and erecting63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length,, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 511 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specification no. FFFFA/NZ |
| 512 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 513 | Supplying and erecting fire brigade header ( Siamese connection ) of 150 mm dia, for supplying water in fire tank completeas per specification no. FF-FA/FMC |
| 514 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 515 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 516 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 517 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 518 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheetand angle iron 25 mm. x 25 mm. x 4 mm.having front doors with viewing glass (8\" x 6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 519 | Providing Round bottom FIRE Bucket of 9 Litrescapacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook |
| 520 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint. |
| 521 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 522 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 523 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps) |
| 524 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 525 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall |
| 526 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete |
| 527 | Supplying, installation, testing and commissioning of jockeyfirepump(JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP |
| 528 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 529 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine,exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mmthick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for autostop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of syntheticenamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 530 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2 mmthick CRCA sheet, compartmentalised with hinged lockable doors, with enclosureprotection class IP54, duly powder coated or painted with accessories dulypainted with two coats of synthetic enamel paint of fire red colour over a coat ofprimer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection withsuitable size solid copper busbar strip of adequate size for all power connectionshaving switchgears and accessories, mountings and internal wiring with adequatesize copper conductor cable, earth terminals, numbering etc. complete in allrespect, suitable for satisfactory operation of main fire pump and jockey(pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings,suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply asper specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomerand branches to motor SFU\"s, starters & outgoing terminals with necessaryaccessories like stainless steel nut bolts with spring washers for connections,mounted on required no of epoxy or porcelain support insulators of suitableratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitablerating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP |
| 531 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 532 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 533 | Supplying and erecting XLPEarmoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ceiling as per specification No.CB-LT/CU |
| 534 | Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD |
| 535 | Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 536 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF FAAS/HTR |
| 537 | Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories, 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP |
| 538 | Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 |
| 539 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 540 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 541 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT |
| 542 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 543 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 544 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 175 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 545 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 546 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 547 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 548 | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 549 | Supplying & erecting inline cut point end pole D. P. Structure for 11/0.415 kV, 200 KVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos. 200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box, Transformer Belt etc.as per drawing (min. 176 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 550 | Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No. OH-CON/ACSR |
| 551 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 552 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN |
| 553 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 554 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 555 | Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA |
| 556 | Supplying and erecting C type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. |
| 557 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, alluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 558 | Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). |
| 559 | Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) |
| 560 | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). |
| 561 | ProvidingElectricityConnectionfrom MSEDCL asperelectricalload 3 phasecommercialload tobeuse as per Requirement of Resort and MSDCEL Licensoning Charges etc, complete |
| 562 | Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed,preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete.i. Lift upto 1.5 m. |
| 563 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 564 | Filling in plinth and floors with contractors approved material /murum / stone dustin 15cm. to 20cm. layers including watering and compaction complete. |
| 565 | Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete. |
| 566 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand |
| 567 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 568 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as perdetailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 569 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 570 | Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesinsquare, rectanular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and paintingcomplete. |
| 571 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-20oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem ifspecialfinishistobeprovidedandcuringcomplete.(Excludingreinforcementand structuralsteel).withfullyautomaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 572 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 573 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt. totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotal coatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubtlesquare fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbe designedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
| 574 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt. totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotal coatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubtlesquare fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbe designedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy