| 1 | CONSTRUCTION OF MID DAY MEAL DINNING HALL MODEL-1 (60 SEATER)Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailingout water as required complete. a)Depth of excavation not exceeding 1500 |
| 2 | Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layercomplete. (Payment to be made on the basis ofmeasurement of finished quantity of work) |
| 3 | A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 4 | Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered earth or local sand. |
| 5 | Supplying and laying brick Khoa of ordinary bats of size (38 mmx 63 mm)of approved quality in 100 mm layer (loose) filling in gaps with small onesrammed and compact as directed true to level and grade. |
| 6 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety |
| 7 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (asnecessary) and marble dust in proportion (1:2) includingsmooth finishing and rounding off corners including rakingout joints or roughening of concrete surface and applicationof cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick |
| 8 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. i) Pakur Variety |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steel |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (f) 25 mm to 30 mm shuttering without staging in foundation. |
| 11 | a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In□Charge |
| 12 | Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth |
| 13 | Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor |
| 14 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.Extra for using approved H.B netting in every third layer in 16 & 17 ofsubhead A above in any floor |
| 15 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (d) 20 mm thick plaster |
| 16 | (c) 15 mm thick plaster (1:6) upto 4m |
| 17 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 18 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 19 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. |
| 20 | White washing including cleaning and smoothening surface thoroughly a)One Coat 20mm plaster area 15mm plaster area |
| 21 | Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly :(ii) External surface (Ground floor)b) Two coats (on new works only).(i) Other than yellow, pink. Outer side 20mm Plaster |
| 22 | Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly :(i) Internal surface (All floor)b) Two coats (on new works only).(i) Other than yellow, pink. |
| 23 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand paperingetc. |
| 24 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) Onsteel or other metal surface :With other than hi-gloss of approved quality-(iv) Two coats (with any shade exceptwhite) |
| 25 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in- charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables suchas electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such aselectricity charges, labour insurance charges etc Payment to be made on the basis of calculated weight of structuraltubular memebrs as specified in relevent IS code in finished work.Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For trusses spanning up to 12.00 m |
| 26 | Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor(i) In Roof:-b) With 0.63 mm thick sheet Inclined partBoth SideFront+Back |
| 27 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)B) 450 mm lapping each way(b) With 0.63 mm sheet |
| 28 | Supplying, fitting and fixing glass reinforced polyester translucent fiber glass sheet to match with GCI Corrugation as per IS: 12866 - 1989 in roof fitted and fixed with 10 mm dia \"J\" or \"L\" hook, bolts and nuts, limpet and bitumen washers and putty with 150mm end lap and one corrugation minimum side lap complete.a) 1.6mm +/- 0.2 mm thick sheet.(2.6Kg/Sq.m)i) Natural white or tinted blue colour |
| 29 | Galvanised or painted wind-tie made ofM.S. flats, fitted and fixed complete including cost of necessary fittings.(b) Made with 50 mm. X 6 mm. flats outer without opening |
| 30 | Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised \"C\" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc.(VI) 25 mm. x 25 mm. x 12 g.flats outer without opening |
| 31 | Supplying fitting fixing UPVC Pipe with all necessary clamps nails including making holes in walls. (110mm dia) singlesocketed 3 meter length |
| 32 | B) UPVC Fittings:c) Bend 87.5 degree(ii) 110 mm. Dia. |
| 33 | GST @18% |
| 34 | Labour Welfire Cess |