Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed