SPL REPAIR TO BLDG. NO A/8/135 AT OLD ME LINE, PROVN OF WALL PANELLING OF PUF SHELTER NO 886,887,888 & 888A, PROVN OF 12 (06 +06) X DEEP FREEZER, 05 X WATER COOLER AND 04 X REFRIGERATOR AT OR MESS, JCO MESS AND OFFR MESS AT PANAGARH MIL STN UNDER GE PANAGARH; 1 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as sepcified and directed. 2 M&L forfly ash brick old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 ,including demolition of brick work built in cement mortar including all quoins, arches, pillar etc all as specified and directed. 3 Demolition of cement concrete reinforced as in ground floors and pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed. 4 M&L for M-25 Design mix using 20mm stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret complete all as specified and directed. 5 M&L for M-25 Design mix using 20mm stone aggregate as in chajjas complete all as specified and directed. 6 M&L for M-25 Design mix using 20mm stone aggregateBeams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 7 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete complete all as specified and directed. 8 Formwork to chullah hoods, chajjas, troughs and similar items including ege for fairfinished surface of concreted complete all as specified and directed. 9 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fairfinished surface of concrete complete all as specified and directed. 10 M&L for rendering 15 mm thickon other than fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:6), complete all as specified. 11 M&L rendering 15mm thickon fair faces of brick work or concrete surfacesfinished even and smoothon walls in cement mortar (1:4), complete all as sepcified and directed. 12 Supply only liquird water proofing compound complete all as sepcified and directed. 13 M&L fortwo coats of acrylic distemper over a coat of alkali resistant primer including preparion of new plastered surfaces of walls over a coat of wall care putty complete all as specified and directed. 14 M&L for preparation of new surface and apply Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface complete all as specified and directed (2.20 + 138.11 = 140.31) 15 M&L Mild steel TMT bars 10 mm dia & over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as sepcified and directed. 16 Ditto but 5 mm to 10 mm dia, as in stripps, spacers complete all as specified and directed. 17 Dismantling framed trusses span n exd 10 mtr complete all as specified and directed. 18 M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-W(Gde- E-250) quality-B complete all as specified and directed. 19 M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; complete all as specified and directed. 20 M&L for two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed 21 Dismantling (corrugated,semi corrugated ) sheet in roof covering complete all as specified and directed. 22 S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 23 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridges fixed with self tapping screws as specified & directed. 24 Taking down window chowkhats or frame not exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified. 25 Taking down chowkhats or frame exceeding 1.5 Sq. m but not exceeding 4 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified. 26 M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made 27 S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorativeflush door shutter one side plain on other sideof 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) 28 S&F factory made single extruded WPC (Wood Polymer Composite) wire gauzed i.e. panel will bewire mesh in lieu WPC , the wire gauze shall be warped on additional square 8mm MS Solidtube and this tube shall bewelded to MS frame complete all as specified and as directed. 29 S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at nctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.Pbrass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief 30 S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fastenersof required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all.complete as per architectural drawings and the directions of Engineer-in-Charge. 31 S&F 4mm thick figured sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading )in square n.exc 0.5 Sqm in each panes complete all as specified. 32 S & F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples, complete all as specified. 33 S&F butt hinges, extruded alluminium,with mild steel hinge pin,bright polished and fixed, type 100 mm size B21 complete all as specified and directed. 34 S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed 35 S&F aluminium anodised 150 mm barrel tower bolts of extruded section complete all as specified and directed 36 S&F Aluminium alloy, anodised, 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. 37 Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) complete all as specified and directed. 38 M&L 75 mm cement concrete type B1 (1:2:4) using 20mm graded aggregate 40 mm thick as in receiving floor finished complete all as specified and directed. 39 M&L for Non Skid ceramic colouredtiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc , over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including dismantling of floor hearth or wall tiling incl cement martar bedding complete all as specified. 40 Dismantling of building board of any discription fixed in any position complete all as specified and directed. 41 S&F in for 4 mm thick non asbestos fibrecement designer buildingboardsfixed or laid/ inserted to timber/GI / Aluminium frame work with screw fixed in ceiling flat or sloping including hangers 4 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long including anodised aluminium snap grid 605 x 605 mm frame work complete all as specified. 42 M& L for 75mm thick PCC 1:3:6type C-1 (Using 40mm gradede crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement, incl making joints 10mm wide to the full depth of PCC at every 3 meters and at every change of direction andcomplete all as specified and directed. 43 M & L for cement concrete 1:3:6, Type C-1 (Using 20 mm graded stone aggregates) in surface channlels and drains complete all as specified and directed. 44 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. 45 S&F Drapery rod (conduit) of dia not less than 25 mm having a corrugated virgin PVC extrusion on it& finials of approved shade with standard MS powder coated/ brackets, fixed to walls with rawl plugs and steel screws complete all as specified and directed. 46 M & L Green marble work 15 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following typesnt with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick Screed bed or backing coat for laying floor finishes in CM 1:6 complete all as specified and directed. 47 Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) complete all as specified and directed. 48 M & L for cement concrete 75mm thick 1:4:8, Type D-2 (Using 40 mm graded stone aggregates) as in sub base for flooringetc complete all as specified and directed. 49 M&L for Chequered Cement concrete tiles 20cm x 20cm x 25mm thick, set jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in cement mortar 1:6, with grey cement and pigment complete all as specified and directed. 50 M&L PCC (1:3:6) type B1 as inkerbs incl necessary form work (cast in situ) etc complete as directed. 51 S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. complete all as specified and directed. 52 M&L for Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheetinclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingcomplete all as specified and directed. 53 E/M PORTIONTaking down carefully aluminium/Copper conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) andmaking good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed. 54 Material and labour point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one wayswitch using1.5 sqmm nominal cross sectional areamultistrandedcopper conductor ,PVC insulated unsheathedFRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked)fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed. 55 All as per item No 54.00above but using 2.5sqmm, One 3 pin 5 Amps socket out let points on independent board 56 All as per item No 54.00 above but5 Amp socket on same boardwith other switches. 57 Material and labour wiring for socket out let on independent Boardscontrolled by one, one wayswitch using4.0 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, includingpressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked)fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FR cable earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified. 58 Supply and fix switch piano flush type, single pole, 5/6 Amps, one way complete all as specified. 59 Supply and fix switch socket combination 2 in 1 multipurpose , (6 Amps ) flush typecontrolled by one switch complete all as specified. 60 S&Fsocketoutlets 2 in 1, 5 pin, 5/6 Amps flush type 230/240 V complete all as specified and as directed .( For Same Board only) 61 Supply and fixed switch socket combination5 in 1, (5/16 Amps ) flush typecontrolled by one switch complete all as specified. 62 Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. 63 Supply and fixing lamp holder, PVC/polycarbonate type with back plate straight or angle suitable for LED lampcomplete all as specified and directed. 64 Supply & fix 5 stepped type electronic fan regulator flush type 240 Volts, 120 watt, ISI marked complete all as specified . 65 Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated unshethed single core multi-stranded copper conductor of size 4 sqmm and one run of 4 sqmm copper conductoras continuityearth wiredrawn in and including PVC conduit concealed (ISI marked) of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directed (Note : (i) Two run of 4 sqmm cable,one run of 4 sqmm cable, one run of PVC conduitshall be measured and paid as one unit. 66 Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated unshethed single core multi-stranded copper conductor of size 6 sqmm and one run of 6 sqmm copper conductoras continuityearth wiredrawn in and including PVC conduit concealed (ISI marked) of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directed (Note : (i) Two run of 6 sqmm cable,one run of 6 sqmm cable, one run of PVC conduitshall be measured and paid as one unit. 67 Supply and fixing wall LED security light fittings 35 watt, 230 volts, minimum lumn output 100 lumen/watt, made up ofpressure dia cast housing with prismatic polycarbonate difuser and industrial LED with secondary optic and IP-65/66 including neccessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete allas specified and directed. 68 Supply and fixing LED light fitting 1 x 20 watt box type with same make LED tube rod side connection ACbox type 4 long wih driver, holder including LED tube connecting up with complete all accessories andconnection from ceiling rose with twin core twisted flexible copper conductor cable withsuitable size and earthing complete all as specified and directed. 69 Supply and fixed recessed mounted 2 x 2 LED lminaire 36 watt for grid ceiling minimum lumen output100 lumen/watt pre-treated CRCA frame powder coated with difused profied including necessary connection complete all as specified and directed. 70 Supply and fixing Decorative wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED Lamp B22 base complete all as specified and directedby engr-in-charge. 71 Supply and fixing 9 watt inverter LEDlamp 9 watt of capacity 220 - 240 volts, 50 Hz complete all as specified and directed 72 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)all as specified and directed engr-in-charge. 73 Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral, 8 ways,with mounting fitted with 200 Amps rated bus bar, DIN channel , neutral link and incoming contact complete all as directed. 74 Supply and fix epoxy powder coated sheet metal enclosure for TPN DBs, 4 ways, double door with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, IP-43 complete all as directed. 75 Supply and fixed inMCB TPN 40 to 100 Amps,C Curve 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed engr-in-charge. 76 Supply and fixed MCB SPN 40 to 63 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 77 Supply and fixed MCB SPN 32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 78 Supply and fixed MCB SP 6-32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 79 Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI lightgrade pipe from upper end of earth plate upto equipments,20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. 80 Taking down old unsv LT cable from under ground/wall complete all as specified and directed. 81 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/loose soilcomplete all as specified and directed. 82 Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. 83 Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 84 Supply, laying, connecting, testing and commissioning of LT under ground cable XLPE insulated, aarmouredheavy duty electric cablewith aluminium conductor , 1100 vlts grade , cross sectional area 16 sqmm 2 core including taking out in trenches complete all as specified and directedNote:- (i) Excavation,sand cushioning,brick will be measured and paid separtely. 85 Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed .Note :- Punned thickness 18 cm shall only be considered for payment 86 Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge. 87 S&F Pipes galvanized,50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified. 88 Supply , installation , commissioning of Glass top, double door deep freezer capacity 425 ltrs , single phase 240 Volt 50 Hz,Precoated inner liners,castor wheels ,UV grade plastic materials,signal indicator,PUF insulation and powder painted body .Make:- Voltas/Blue Star 89 Supply and installation ,commis-sioning of water cooler fully stainless steel , electric driven single phase having approx storage and nominal cooling capacity as shown 60/120 Ltrs, fully stainless steel, electric driven single phase, ISI marked.Make:- Voltas/Blue Star or eqvt. 90 Supply , installation , commissioning of Glass top, double door deep freezer capacity 425 ltrs , single phase 240 Volt 50 Hz,Precoated inner liners,castor wheels ,UV grade plastic materials,signal indicator,PUF insulation and powder painted body .Make:- Voltas/Blue Star 91 Supply and fix Three P door refrigerator, electric driven (Single Phase) of capacity 300 Ltr ,ISI marked,240 Volts FP 313D PROTTON ROY COOL ILLUSIA (N) All as directed by EIC. Make:- Whirlpool/Sumsung/LG 92 Supply and fix switch in replacement piano flush type, single pole , 5/6 Amps, one way complete all as specified. 93 S&Fsocket in replacement outlets 2 in 1, 5 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed .( For Same Board only) 94 Supply and fix in replacement switch socket combination 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch complete all as specified. 95 S&Fsocketin replacement outlets 2 in 1, 5 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed .( For Same Board only) 96 Supply and fixedin replacement switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. 97 Supply & fixin replacement ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. 98 Supply & fix in replacement stepped type electronic fan regulator flush type 240 Volts, 120 watt, ISI marked complete all as specified . 99 Supply and fixing in replacement PVC casing and caping /conduit pipe (ISI mark) of not less than 20mm size, internal wiring complete including necessry itemsall as specified and directed by engr-in-charge. 100 Supply and fix in replacement 8x10 PVC Switch Box ISI marked complete all specified and directed. 101 Supply and fix in replacement 7x4 PVC Switch Box ISI marked complete all specified and directed.