Tender For Construction Of Processing Shed 760 Sq. Mt-2 EXCAVATIONExcavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation, and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift up to 1.5 m.) By Mechanical Means 3 Excavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting, etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 4 Filling in plinth and floors with approved excavated material in 15cm to 20cm layers, including watering and compacting, etc. Complete. 5 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15cm to 20cm including watering and compaction etc. complete. 6 Providing soling using 80mm size trap metal in 15cm layer including filling voids with crushed sand/grit, ramming, watering, etc. complete. 7 Providing pre-constructional anti-termite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorpyrifos per one square metre of vertical surface area covering 10 years guarantee on bond paper 8 FOUNDATION & FOOTING(P.C.C. FOR FOOTING ) Providing and laying cast in-situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, and curing complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 9 (FOOTING CONCRETE ) Providing and laying cast in-situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage, and footings of R.C.C. columns and steel stanchions, etc. including bailing out water, steel centering, formwork, cover blocks, laying/pumping, compaction, and curing, roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). 10 ( COLUMNS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided, and curing, etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). 11 ( PLINTH BEAMS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, and roughening the surface if special finish is to be provided, and curing, etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). 12 ( PLATFORM LANDING CONCRETE )Providing and laying Cast-in-situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). With fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). 13 Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches, etc. as per detailed designs, drawings, and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding, and supporting as required, complete. 14 ( TREMIX FLOOR CONCRETE WORK ) Providing and layingin situ cement concrete M20 with TREMIX TREATMENT for 100 MM thickness for flooring with groove cutting of 4mm wide and 20 mm deepwith necessary refilling with bitumen etc. complete. 15 (Brick Work) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls, including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces, and watering, etc. Complete 16 ( BRICK WORK ) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 17 ( INTERNAL PLASTER ) Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, etc. complete. 18 ( EXTERNAL PLASTER ) Providing sand-faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag, curing the same for not less than 2 days, and keeping the surface of the base coat rough to receive the sand-faced treatment 6 to 8mm thick in cement mortar 1:4, finishing the surface by taking out grains and curing for fourteen days, scaffolding, etc. Complete. 19 Providing and applying white-wash in two coats on old/newplaster do rmasonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 20 Providing and applying colour-wash ..of approved colour and shade in one coat to old surfaces which are to be recoloured including scaffolding, brushing and brooming down. (excluding base coat of white wash) etc. complete. 21 Providingandfixingmildsteelgrillworkforwindows,ventilators,etc.15Kilogram/OneSquareMetreasperdrawingincludingfixturesnecessaryweldingandpaintingwith one coat of anticorrosive paint and two coats of oil painting complete. 22 PEB WORK Supplying, fabricating, erecting and fixing in position of steel structures at all elevations using fusion welding quality steel E-350 (Fe490) conforming to IS:2062 - 2006. Rate shall include cost of cutting, welding, splice plates and packing plates, transporting,straightening, cleaning, fabricating and erecting in position welded/bolted Structural steelwork in columns, beams, trusses, purlins,platforms, ladders, monorails, staircases ,supports, strengthening of steel membersetc. at site to line and level, supply of approved bolts/nuts/washers etc. complete as per drawings includingpainting as per G4/G5/G6 before erection and all materials and labour charges etc., complete andincluding Sand blasting & painted with 1 coats of enamel paint (Berger EPILUX SG – HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer - 35-50 micron etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / Construction Manager. (The rate quoted shall include cost of bolts,nuts, washers, welding and electrodes required for the complete work). 23 Supplying, fabricating and erecting of Cold Formed Light Gauge structural steel members conforming to IS:801/ IS:811 hot-dip galvanised to IS:4759 - 96 including cutting, welding or bolting, splice plates and packing plates,transporting,straightening, cleaning, fabricating and erecting in position. 24 Supply & Fixing of PPGI sheets of 0.5 mm thick as shown in drawing or as directed by engineer incharge with all necessary accessories.(Essar) Make) 25 Supply & Fixing of 0.5 mm thk PPGL roof accessories as per drawing or as directed by engineer incharge-CORNER FLASHING,Center Ridge,Gable flashing 26 Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends,all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc., complete and as directed as per engineer incharge 27 Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour charges etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / 28 Supply & Fixing of 2mm thkpolycarbonate sheets as per drawing & as directed by engineer in-charge. 29 Supply & Fixing of turbo ventilator with 610 mm throat, having base ring & top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of2mm thk clear 1.020mtr wide & 1.7 mtr long. 30 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness, reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with holdfast arrangements, M.S. Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high-grade cast iron or mild steel and one coat of red lead primer, etc. complete. (I.S. 6248-1979) (Without mechanical gear) 31 ROYALTY CHARGESFOR SAND 32 FOR METAL 33 FORMUROOM 34 LAB TESTING CHARGES Cement - Fineness,Standard Consistency, Setting Time (Initial & Final ), Compressive strength, Soundness 35 Concrete M-25 - Mix Design with all tests on basic materials 36 Concrete M-25, M20 and M-10 grade - Concretecompressive strength 37 Crushed metal - Water absorption, Specific gravity,Impact value,Crushing value 38 Brick - Crushing value, Water absorbation, & Specific Gravity 39 Steel - Tensile strength ,Yield stress, ultimate tensile stress, %elongation, weight per running meter,Bend/Rebend test.(Set of 3 Bars) 40 Murum - Plasticity Index 41 Murum - Field Density of compacted layer 42 Murum - ( Proctor Density Test ) 43 Sand Test -Sieve Analysis 44 ELECTRICAL WORKS Providing and fixing lioghtening conductor system comprising of erecting Air - Termination consisting of tubular copper rod of 25 mm dia.1.2 mm thick with multiple point shead 1.2mt.long (Heavy Duty)welded or clamped to G.I. pipe pole B grade 50 mm dia of required length with M.S . round base plate 25 Cm diamand 10 mm thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 cm dia m x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cad mium plate nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and G.I. pipe 40 mm dia2 meter length burried in earthing plate remining portion above ground level for watering and refilling comcpete Note-Copper strip from lightening conductor is not considered in this item. 45 Providing and fixing copper strip 25 mm wide and 3 mm thick for lightening conductor including fixing with screws required scaffolding etc.complete Note-Lightening conductor and earthin pits is not considered in this item 46 Supplying and errecting HMS PVC conduit FRLS Grade 25 mm dia. With pvcaccessorieson wall/ ceilling as per specification No. WG-MA/ CON 47 Supplying and errecting mains with 1X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any otherplaces as per specification No. WG-MA/CON 48 Supplying and errecting mains with 2X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any otherplaces as per specification No. WG-MA/CON 49 Supplying and errecting mains with 2X2.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Buss bars or any otherplaces as per specification No. WG-MA/CON 50 Supplying and errecting modular type 3pin 6/16 A multy sockets with safety shutter, duly errected on provided plate and box with wiring connectionscomplete 51 Supplying and errecting PVC surface maodular switch box with doublemounting plate for 6 module duly errected 52 Supplying and errecting PVC surface maodular switch box with doublemounting plate for 12 module duly errected 53 Supplying and errecting street light wall bracket made from 40 mm dia G I pipe1.2 m in total length complete as per specification no FG- BKT/WB 54 Supplying, errecting and marking SPMCB 6A to 32 A, C series with rated short -circuit braking capasity 10kA in provided distribution board as per specification no SW-SWR/MCB 55 Providing earthing with galvnised iron earth plate size 60 X 60 C 0.6 cm complete with all materials, testing and recording the resuilt as perspecification no EA-Ep 56 Prviding and managing 20 Trees in the same premises, under Management Strategies And Implementation Plan ( MSIP ) to ManageEnvironmental , Social , Health And Safety.