}

Tender For Renovation / Refurbishment / Upgradation Works In Health Centre At Csir-Cecri, Karaikudi., karaikudi-Tamil Nadu

Council Of Scientific And Industrial Research has published Tender For Renovation / Refurbishment / Upgradation Works In Health Centre At Csir-Cecri, Karaikudi.. Submission Date for this Tender is 20-08-2025. Building Work Tenders in karaikudi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50603321
Tender For Renovation / Refurbishment / Upgradation Works In Health Centre At Csir-Cecri, Karaikudi.
Tender
Indian
Tamil Nadu
Karaikudi
20-08-2025

Tender Documents

Tender Details

Tender For Renovation / Refurbishment / Upgradation Works In Health Centre At Csir-Cecri, Karaikudi.; 1 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2 Of area 3 sq. metres and below 3 Of area beyond 3 sq. metres 4 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. 5 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : 6 Of sectional area 40 square centimetres and above 7 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 8 For thickness of tiles 10 mm to 25 mm 9 Dismantling the existing old damaged wash basin & sink including necessary fittings as directed by the Engineer-in-charge. 10 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. 11 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 12 G.S. Sheet 13 Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 14 In cement mortar 15 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 16 Closing the minor holes upto 0.10sqm area in existing mansonry wallls with necessary plastering and neat finishing as directed by the Engineer-in-charge 17 Removing old unnecessary clamps , angles ,curtain rods and other unwanted minor parts projected in walls & roofs. the rate inclusive of all lift and leads including necessary scaffolding as directed by the Engineer-in-charge. 18 Removing and placing the existing wooden furnitures and other movable items after executing the work including proper placing, cleaning wherever & whenever required as directed 19 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 20 Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 21 Demolishing the existing wethering course laid in roofs and including disposal / levelling near the site as directed. 22 Supplying chemical emulsion in sealed containers including delivery as specified. 23 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 24 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 25 Along the external wall below concrete or masonry apron usingchemicalemulsion@2.25litresper linear metre including drilling and plugging holes etc.: 26 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 27 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 28 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 29 Providing and injecting approved grout inproportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 30 Stirrer mixed SBR Polymer (of approved make) modified Cement slurrymade with Shrinkage Compensating Cement in concrete/RCC work. 31 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. 32 Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make 33 Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. 34 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 35 All kinds of soil. 36 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 37 Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 38 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) 39 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 40 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 41 Cement mortar 1:6(1 cement :6 coarse sand) 42 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : 43 Cement mortar 1:6 (1 cement: 6 coarse sand) 44 Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth upto floor V level. 45 Cement mortar 1 : 4 (1 cement : 4 coarse sand) 46 12 mm cement plaster of mix: 47 1:6 (1 cement: 6 coarse sand) 48 Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : 49 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 50 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 51 Providing,transporting,hoistingandfixingaboveplinthlevelupto floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 52 Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. 53 Thermo-Mechanically Treatedbars of gradeFe-500D or more. 54 Centering and shuttering including strutting, propping etc. and removal of form for 55 Lintels,beams,plinthbeams,girders,bressumersand cantilevers 56 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 6 mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and sofits. 57 50 mm thick 58 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 59 Second class teak wood 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202(PartI)non-decorative type,core of blockboardconstruction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 61 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 62 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 63 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). 64 Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 65 Frame size 45 x 85 mm 66 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 67 30 mm thick 68 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 69 Extra for providing vision panel not exceeding 0.1sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 70 Rectangular or square 71 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 72 Providing and fixing bright /matt finished Brass tower bolt of approved quality & make with necessary screws etc all complete. 300mm x 10mm 73 Providing and fixing Stainless steel latest ornamental fancy handle 1metrelong including necessary screws as directed by the Enginner- in -charge 74 Providingandfixingaluminiumextrudedsectionbodytubulartype universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 75 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 76 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) 77 shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. 78 Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. 79 Using R3 series with frame (85 mm & above) x (40 mm & above) & glazed sash (30 mm & above) x (55 mm & above) & fly screen sash (20 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated handle on every glazedpanelalongwithmulti-pointlocking system. (Height upto 1.8 metre). 80 Fixed window/ ventilator without mullion /transom. 81 Using R2 series with frame (39 mm & above) x (39 mm & above). (Height upto 1.2 metre) 82 Providing and fixing glazing in UPVC window, ventilator shutters and partitions etc. as per the architectural drawings and the directions of engineer-in-charge. With colour glass panes of 4.0 mm thickness 83 Providing and fixing fiber glass mesh mosquito net in UPVC window, ventilator shutters etc. withas per the architectural drawings and the directions of engineer-in-charge. 84 Providing and fixing horizontal cassette roller blinds (Zebra) made of synthetic fabric of polyester /cotton with required pattern . Cassette mounting brackets shall support both the roller tube and the cassette. They must be capable of mounting inside, outside or to the ceiling, with the clutch on either right or left hand side of the roller. Cassette shall be installed to conceal the roller tube and mounting hardware. Cassette shall be made of approximately extruded aluminium and shall be painted with a high quality baked enamel finish, or finished with an anodized finish. Size of cassette depends on the size of blind.Cassette shall be able to accommodate a coordinated fabric insert and as directed by the Engineer-in-charge. 85 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : 86 For fixed portion 87 Powder coated aluminium (minimum thickness of powder coating 50 micron) 88 Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 89 Powder coated aluminium (minimum thickness of powder coating 50 micron) 90 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 91 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 92 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 93 Providingandfixingcupboardshutterwith 19mmthickoneside decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) 94 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 95 1.0 mm thick 96 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVCfoil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprisingof virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A 97 category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 98 18 mm thick 99 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 100 200 mm 101 Providing and fixing bright /matt finished Stainless Steel tower bolt of approved quality & make with necessary screws etc all complete. 100x10mm 102 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 103 50 mm 104 Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1as per IS:1068 and fixing with necessary screws etc., complete. 105 Overall width 35 mm 106 Providing and fixing false ceiling at all heightincluding jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting & frame work with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I 107 Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets andgalvanized with zinc coating of 120 gms/sqm(bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm 108 long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, 109 all as per manufacturers specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 110 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between mainT at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick 111 (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main T runners to be suspended from ceiling using al. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main T. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 112 Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection >85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. 113 Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 114 Glazed Vitrified tiles Matt/Antiskid finish of size 115 Size of Tile 600 x 600 mm 116 Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 117 Granite stone slab of colour black, Cherry/Ruby red 118 Area of slab over 0.50 sqm 119 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 120 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 121 Providing and fixing white vitreous china laboratory sink 32 mm C.P brass waste fitting , suitable felxible PVC waste hose , and 32mm C.P . brass trap with necessary C.P . brass unions complete, including cutting and making good the wall wherever required : Size 600x450x200 mm 122 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 123 15 mm nominal bore 124 Providing and fixing wash basin with Rackbolt, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste fittings & waste hose of standard pattern,wherever required White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 125 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 126 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 127 W.C. pan with ISI marked white solid plastic seat and lid 128 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 129 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 130 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 131 15 mm nominal bore 132 Providing and fixing PVC multi trap (Nahini trap) with jalli including necessary fittings as directed by the Engineer - in- charge. 100mm dia 133 Providing and fixing CP two way tap of approved quality as directed by the Engineer-in-charge 15mm nominal bore 134 Providing and fixing CP coatedhealth faucet 1.0mtr length of approved quality with necessary fittings and screws as directed by the Engineer - in -charge 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. 137 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 138 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 139 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 140 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 141 Inside size 90x80 cm and 45 cm deep including C.I. coverwithframe(lightduty) 455x610mminternal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 142 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 143 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 150mm diameter 144 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 110mm diameter 145 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 63mm diameter 146 Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 147 All kinds of soil 148 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 149 ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 150 20 mm nominal dia Pipes 151 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 152 25 mm nominal dia Pipes 153 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 154 25 to 40 mm nominal bore 155 Providing and fixing CPVC ball valve of approved quality, High or low pressure, with plastic floats complete as directed by the Engineer -in -charge. 25 mm nominal bore 156 Providing and fixing granite of 18 mm thick gang saw cut, mirror polished (double side), premoulded and prepolished, machine cut for urinal spearator and similar locations of required size (1300mm x 600mm), approved shade, colour, textureand fixing the walls as per site condition, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 157 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mmwith fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 158 Providing and fixing CP brass urinal half turn valve of aprroved quality as directed by the Engineer-in-charge. 15mm nominal bore 159 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 160 Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for pressed clay roof tiles as directed. 161 Providing & Applying polymer modified, flexible cementatiouswaterproofing coating with elastic waterproofing polymers on roofsurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 162 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 163 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 164 Hot finished welded type tubes 165 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 166 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 167 Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 168 Providingand fixingexpansionhold fasteners onC.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 169 Wedge expansion type 170 Fastener with threaded dia 12 mm 171 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 172 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 173 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 174 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. 175 Two coats 176 Providing andapplyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 177 Finishing walls with Acrylic Smooth exterior paint of required shade: 178 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 179 Finishing walls with textured exterior paint of required shade: 180 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 181 Providing and applying acrylic based granular textured wall coating finish in any shade with spray coat bubble or compact or rustik shade.The rate inclusive of POP punning to the wall with proper level & making grooves and preparation of surface as directed. new work two or more coats applied @ 3.28ltr/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm 182 Cutting holes up to 30x30 cm in walls including making good the same: 183 With common burnt clay F.P.S. (non modular) bricks 184 Providng and fixing precast reinforced cement concrete rings with 25mm thick of size 450mm dia & height 300mm in existing masonry walls with neat finishing as per the direction of Engineer-in-charge. 185 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 186 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 187 Making through holes in plain or reinforced cement concrete / brick masonry wall with diamond core drilling system by mechanical means as directed100mm dia 188 Providing polishing white pebbles stone for vase fillers outdoor / indoor decoration as directed by the engineer-in-charge. size 20mm to 40mm 189 Providing and fixing wall lining / ceiling factory made moulded WPC ( wood polymer composite)louver panel at all height with contemporary design ,jointing and finishing to a flush finish with recommended screws all as per manufacturers specification including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge. (Excluding the cost of frame work or backing boards) 160 wide x23 mm thick 190 Cutting / Carving of plywood / ACP sheet/WPC/PVC/ cement board with CNCoperations in the required patternas directed by the Engineer-in-charge upto 25mm thick 191 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing andmakingcurvature(wherever required)andfittingthesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 192 Making letter with 12mm thick WPC sheet in all colours including neccssary machine cutting andneat finishing with sutable font. Fixing and placing in position at required height with neccssary screws / bolt & nuts. The rate inclusive of all transport charges , scaffolding and neccssary fittings as directed by the Engineer In-charge. 200mm high 193 Providing and fixing PVC beading for corner of the ceramic glazed wall tiles area and positioning as approved by engineer in charge. 194 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 195 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 196 Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with Non -decorative lamination on both sides 197 Providng and fixing precast reinforced cement concrete rings with cover 25mm thick of size 900mm dia & height 300mm by using 6mm mild steel reinforcement 100mm c/c in both direction. The rate inclusive of all lifts and leadsas directed by the Engineer-in-charge. 198 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 199 Weathering course using best quality of broken jelly of 20mm gauge in pure slacked lime (no sand to be added) over roof slab the proportion of brick jelly to lime being 32:12.5 by volume and laid over in a single consolidated to the required design and finished thickness by beating the concrete with wooden beater to the size required slope of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water as per standard specification and as directed by the departmental officers. 200 Providing and laying pressed clay tiles (as per approved pattern 18 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. 201 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 202 Fixed to openings /wooden frames with rawl plugs screws etc. 203 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 204 Providing and fixing glass door stainless steel lock of approved quality , design and make with necessary fixing arrangements as directed by the Engineer-in-charge. 205 Supplying and fixing self adhesive decorative film for glass doors/ winows /glass partition/backing of suitable boards including requireddesign as directed by the Engineer-in-charge. 206 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 207 150 x 100 mm size P type 208 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 209 Supplying and Fixing of stainless steel (304 grade) polished CSIR-Emblemfinished with suitable mounding struds inluding neat finishing at directed by Engineer-in-charge 450mm dia 210 Dismantling doors, windows,wooden board,wooden frames,aluminium partitions,false ceiling materials and clerestory windows (steel ,aluminium or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 1500 metres lead (store yard) : 211 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 212 For pipes 100 to 250 mm diameter 213 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 3 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / 214 Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws,nuts,bolts, washers,cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain 215 wall with aluminium compositepanel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 216 Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 217 110 mm diameter 218 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. 219 Bend 87.5° 220 110 mm bend 221 Shoe (Plain) 222 110 mm Shoe 223 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 224 Group C 225 Wiringfortwincontrollightpointwith 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 226 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 227 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 228 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 229 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 230 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 231 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 232 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 233 4 X 10 sq. mm + 2 X 6sq. mm earth wire 234 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 235 Supplyingand drawingfollowingpair 0.5mmdiaFRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 236 2 Pair 237 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 240 100 mm X 100 mm X 60 mm deep 241 200 mm X 150 mm X 75 mm deep 242 200 mm X 300 mm X 100 mm deep 243 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. 244 5/6 A switch 245 15/16 A switch 246 3 pin 5/6 A socket outlet 247 6 pin 15/16 A socket outlet 248 Telephone socket outlet 249 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 250 Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 251 1 or 2 Module (75mmX75mm) 252 3 Module (100mmX75mm) 253 6 Module (200mmX75mm) 254 12 Module (200mmX150nnm) 255 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 256 Installation,testingandcommissioningofpre-wired,fluorescent fitting / compact fluorescent fittingof alltypes,complete withall accessoriesand tube/lamp etc.directly on ceiling/ wall,including connectionswith 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 257 Numberingofceilingfan/exhaustfan/fluorescentfittingsas required. 258 Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 259 Group C 260 Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MOBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 261 4 way (4 + 12), Double door 262 6 way (4 + 18), Double door 263 8 way (4 + 24), Double door 264 Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) 265 4 way (4 + 12), Double door 266 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. 267 Single pole 268 Double pole 269 Triple pole 270 Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required. 271 Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240VCcurveDPMCBcompletewith connections, testing and commissioning etc. as required. 272 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 273 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415Volts,onsurface/recess,completewithtestingand commissioning etc.as required. 274 For 4 way, Double door TPN MCBDB 275 For 6 way, Double door TPN MCBDB 276 For 8 way, Double door TPN MCBDB 277 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc. as required. 278 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powdercoatingM.S.cabletrayswithperforationnotmorethan 17.5%,in convenient sections, joined with connectors, suspended fromtheceilingwithM.S.suspendersincludingbolts&nuts, painting suspenders etc as required. 279 150 mm width X 50 mm depth X 1.6 mm thickness 280 300 mm width X 50 mm depth X 1.6 mm thickness 281 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powder coatingM.S.cable traysbends withperforationnot more than 17.5%„ joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 282 150 mm width X 50 mm depth X 1.6 mm thickness 283 300 mm width X 50 mm depth X 1.6 mm thickness 284 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincludingbolts&nuts,paintingsuspendersetcas required. 285 300 mm width X 50 mm depth X 1.6 mm thickness 286 Earthing withG.I.earthplate 600mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 287 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 288 Supplying andlaying 25 mm X 5 mm copper strip at 0.50 metre belowground asstrip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 289 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 290 Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. 291 Providingandfixing4.00mmdiacopper wireonsurfaceorin recess for loop earthing as required. 292 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 293 Laying of one number PVCinsulated andPVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 294 Above 35 sq. mm and upto 95 sq. mm 295 Above 95 sq. mm and upto 185 sq. mm 296 Laying of one number PVC insulated andPVC sheathed / XLPE powercableof1.1KVgradeoffollowingsizeintheexisting masonry open duct as required. 297 Above 35 sq. mm and upto 95 sq. mm 298 Above 95 sq. mm and upto 185 sq. mm 299 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 300 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 301 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mmMS flat clamp) 302 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 303 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 304 Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 305 312 X 70 sq. mm (38mm) 306 3% X 150 sq. mm (50mm) 307 Supplying and fixing of 32 mm dia X 2.00 metres long GI. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 308 Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. 309 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 310 90 mm dia (00-90 mm & I0-76 mm nominal) 311 120 mm dia (00-120 mm & ID-103 mm nominal) 312 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 313 Removing the existing TPN and SPN DBs,changeover switch Db,SFU’s of all size, Fuse carriers,Main switches, Sub main, circuit and point wirings,switch boards, power boardsfan and light fittings with Various size of cables , removing of Incoming cables/wires for old PDB and LDB and other unused and worn-out electrical installations, and other unwanted Electrical materials in the proposed area complete in all aspects as per site condition and returning the removed items to the departments stores or any such place within the campus area as directed by the engineer in charge as per site condition. 314 Shifting of 15 KVA UPS System (including UPS Unit and Batteries) from passage to proposed new panel room. Scope includes:Disconnecting ,shifting andreconnecting UPS,Batteries (20Nos) power and battery cables, Installation and realignment in new location, Testing and commissioning all required manpower, tools, and accessories as per site condition. 315 LED Street Light Fitting :Supply and fixing ofoutdoor type LED Street light fitting,36W, in the existing pole (up to 40mm dia ) located in site along with all accessories as required as per site condition. Simial to JV Lukers STRADA Model No.LST- 36 or Equivalent as approved by department.(note:The fitting should have 2 years warranty replacement) 316 2 FtLED Batten:Supply of 2 feet extruded aluminium LED batten indoor type 12W, having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura Smat BrightModel No. BN021 LED12S-6500 PSU GR or Equivalent with time of 25,000 hours as approved by department 317 LED ML Fitting : Supply of LED mirror light fitting of 18 W,WW having high efficiency,wall/ surface mounting with suitbale driver of wide voltage range as required. Similar to JV Lukers LITA T8 Model No.LMCL 18 or Equivalent as approved by department.Note:the fitting shall have 2 years warranty replacement 318 12 Way VTPN DB with 100 A MCCB:Supplying and fixing 12 way surface/ recess MCCB mounting, 415 volts, vertical type TPN MCB distribution board (with wire way/cable end box) of sheet steel,dust protected, duly powder painted, inclusive of 160 amps tinned copperbusbar,commonneutrallink,earthbar,dinbarfor mounting MCBs, along with 100 A,16/25 KA TPN MCCB, phase barrier and spreaders for incomer, interconnection between DB incomer and the bus bars/Existing mains shall be made with copper cables of appropriate rating as required.The VTPN DB shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling,cutting welding painting etc)firmly in the existing wall/ existing base channel as required as per site condition complete in all aspects.The above DB shall include the following C series, 10 kA MCBs in the out going circuits 319 TP MCB-63A-2 NosSP MCB-6-32A-30 NosBlanking plates -As required.Make : Legrand /Schneider /Siemens/Hager or equivalentsubject to the approval of the department. 320 TP +N MCB With Enclosure for AC outdoor:-Supplying and fixing TP+N415 volts, 63 amps,C Series,MCB including Enclosure asrequired as per site condition complete in all aspects . 321 Raceway 100x50 mm: Supply and fixing of100 x 50 mm UPVC cable management complete system / raceway trunking along with all accessories as requiredin surface and carrying out the proposed electrification works complete in all aspects as required as per site condition.Make : MK/ Legrand/Siemens or Eauivalent as approved by department. 322 Raceway 50x50 mm:Supply and fixing of50 x 50 mm UPVC complete cable managementsystem / raceway trunking along with all accessories as requiredin surface and carrying out the proposed electrification workscomplete in all aspects as required as per site condition.Make : MK/ Legrand/Siemens or Eauivalent as approved by department. 323 TP MCB:-Supplying and fixing TP 415 volts, 63 amps,C Series,MCBin the existing DBas required as per site condition complete in all aspects . 324 TP +N MCB:-Supplying and fixing TP+N415 volts, 40 amps,C Series,MCBin the existing DBas required as per site condition complete in all aspects . 325 2x2 LED fitting: Supply and fixing recessed mounting2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WHalong with suitable driver with ripple less than 5%for flicker/glare-free light in the existing false ceiling with required accessoriessuch as chain/stringfor supporting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 326 2x2 LED fitting: Supply ofrecessed mounting2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WH along with suitable drive rwith ripple less than 5%for flicker/glare-free light as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 327 Square/RoundLED down lighter :Supply and fixing ofrecessed mounting Square Down lighter LED energy efficient fitting,1200 lumens, 12W, WW/WH light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Sleek surface slim profile SM250/260 LED 12S 6500 PSUor Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 328 Square/RoundLED down lighter :Supplyofrecessed mounting Square Down lighter LED energy efficient fitting,1200 lumens, 12W, WW/WH light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Sleek surface slim profile SM250/260 LED 12S 6500 PSUor Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 329 Smart LED Strip Light : Supply, installation, testing and commissioning of indoor type, 5 mtr, 12 V,25 W,2200 lumens, Smart WiFi Tunable white strip light that works works with voice/ WiZ connected/remote based application along with suitable AC driver of continuous duty,etc having an adhesive for firm fixing and2 years replacement warranty etc.The strip light shall be installed in the existing confernce room wall panel/ false ceilingwith required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. Similar to Phlips 5 Mtr WiZ Smart Strip LightProduct SKU : 929003551501 or equivalent as approved by department. 330 4 Ft Industrial LED Batten:Supply of standard 4 feet industrial indoor 40W,LED batten having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura LED Next Model No. BN308CLED40S-6500 L1 PSD or Equivalent as approved by department.(Note:The LED batten shall have minimum 2 years relacement warranty.) 331 LED Wall Lamp : Supply, installation, testing and commissioning of indoor type bigwall mounted modern creative light fixture LED wall lampmade up of glass or combination of metal and crystal material having Gold/Shining lamp shade, Bold vibe, Abstract pattern and the model will be selected by the engineer in-charge . the basic amount of the fitting should be reckoned as Rs 5000/ (± 5%) excluding GST. operating with AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mounted in the wall mounting panel and other structures with required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. 332 LED Silicon Neon Profile Tube Light Lighting: Supply, installation, testing and commissioning of indoor type, 10 mtr, 24 V,75 W,vibrant lighting with low energy consumptionalong with suitable AC driver of continuous duty,etc having an adhesive for firm fixing and2 years replacement warranty etc.TheProfile Tube Light shall be installed with different meter length in the existing conference room wall panel/ false ceilingwith required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. Similar to Harold 10 Mtr Silicon Neon Profile Tube Light or equivalent as approved by department. 333 Butterfly Gold LED Wall Lamp:Supply, installation, testing and commissioning of indoor type bigwall mounted modern CITRA Transparent Acrylic Butterfly Gold LED Wall Lamp Bedside Light - Warm Whitemade up of Metal or combination of metal and crystal material having Gold lamp shade, Bold vibe, Abstract pattern and minimum dimension of 24Lx19Wx12H CM, AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mountedin the wall mounting panel and other structures withrequired accessories, interconnections of adequate rated cablescomplete in all aspects as required as per site condition. Similar to CITRA Transparent Acrylic Butterfly Gold LED Wall Lamp Bedside Light - Warm White or equivalent as approved by the department. 334 Sun flower Wall Lamp:Supply, installation, testing and commissioning of indoor type bigwall mounted modern Lamp master 3-in-1 LED Sunflower Wall made up of Acrylic or combination of metal and crystal material having Lamp master 3-in-1 LED, Abstract pattern and minimum dimension of 23Lx5Wx23H CM, AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mountedin the wall mounting panel and other structures withrequired accessories, interconnections of adequate rated cablescomplete in all aspects as required as per site condition. Similar to Lamp master 3-in-1 LED Sunflower Wall & Ceiling Light - Creative Acrylic Decorative Wall Light or equivalent as approved by the department. 335 Exhaust fan CATA C B15 Matic: Supplyingand fixing of window mounted plastic housing of industrial type white colour exhaust fan,automatic shutter, 220-240 V 50 Hz,class B insuslation, theramal cutout,43 dB noise level, 40 Deg ambient, 320 CFM suitable for 150 Sq Ft size room in the existing window of the bathroom as required with necessary accessories, interconnection etc as per site condition. Similar to CATA C B15 Maticor equivalent as approved by department. 336 Supply of constant current LED Driver suitable for 2x2’ Full Glow LED Fitting, with thespecifications is Input Voltage: 140–270V AC, Output: Constant current, suitable for 36W–40W LED, Power Factor: ≥0.95, THD: <10%, Surge Protection: ≥4kV, Efficiency: ≥85%, Specify approved make or “equivalent” 337 Supply of LED Driver for Down lighter LED fitting 12W, 1200 Lumens, WW/WH color. Input: 220-240V AC Output: 12V/Constant Current, PF > 0.9 , Efficiency > 85% , THD < 15%, CE/RoHS compliant andSpecify approved make or “equivalent”. 338 Supplyand installtion of Rubber mat of size (100X200) cm as persite condition at VTPN DB area of thickness as per standard IS 15652. 339 Supplying & fixing of ariel clamp set of Suitable angle for fixing following HRC Fuse Base and Fuselink on the LT polewith 250 AMPS HRC Fuse base (make: L&T) and 250 A HRC Fuse link (make:L& T) with necessary accessories assembled as complete set and mounted in the existing LT pole along with the termination of UG cable as required as per site condition. 340 Dispensary MV Distribution Panel a) Supply, installation, testing and commissioning of In Door type panel manufactured by a CPRI approved panel fabricator compling IS standards.LT Panel Sheet thickness should not be less than 2.00 mm for load bearing members and doors and LT panel cubicle/vertical should be with 9 fold design structure for more strength, with detachable gland plates of 3mm thick for entry of cables from the top/bottom as required with 400A ratings electrolytic copper bus bars with sleeves (100% for phases & 50% neutral & as per standards for earth running all around the panel), free standing, totally enclosed, suitable for 3 phase and neutral. The panel should be modular in design with ZERO welding and suitable for 415 V, 3 phases, 50 Hz, 4 wire systems IP 43 & IK09. The LT panel bus bars shall be supported with the Glass reinforced Polyamide 6.6 type bus bar support suitable up to 140 deg C. Main incoming & outgoing switchgear/circuit breakers should be of same manufacturer and switchgear should be of same series/model of the OEM. 341 No live part should be accessible from the front, while operating the door. Total Discrimination chart should be prepared for all the LT panels & should be submitted before approval along with GA Drawing. Incomer :- 1 No’sof 320 Amps 4 pole Changeover switch parallel with a separate suitable HRC fuse carrier set along with neutral bus on the load side with necessary interconnections as required as per standards etc, direct rotary handle, 2 set of spreader terminal, phase barrier,intersource barrier, shorting links set of 4,415/690 V AC, 100 % Neutral,12.5 kA, insulation voltage of 1000 V Ac, impulse voltage of 12 kV, mechanical and electrical rating of 10000 and 2000 cycles respectively confirming to IS as amended up to date complete withall otheraccessories etc as required. Similar to TSE power line, Frame-2 Cat No.424188 of Legrand or equivalent as approved by department. 342 i) Digital multifunction meter class 1 accuracy, with Rs 485 portoutput for communication toread V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, etc - 1No.ii) 320A/5A CL.1 accuracy, 15VA burden CT - 3 Nos.iii) RYB and ON, OFF, indication lamps for both source connected with suitable control fuse and MCB -1 Set.Outgoing: 8 No’s of100 Amps TPN MCCB (Icu=10 kA=Ics )Thermal magnetic based, 415V, 100% Neutral, rating confirming to IS as amended up to date complete with over current & short circuit protection, spreaders, phase barriers, direct rotary handle etc with required interconnections as required complete in all aspects as required 343 Erection in all aspect including providing necessary angle iron channels for the panel to be mounted on the existing trench/brickwork/panel room, with required fastners, accessories and other allied works deemed to be required to complete as per site condition (including necessary civil works as required and finishing the same to the original condition, along with cable excavation for loose/loop purpose as required.) 344 Supply, fabrication, and installation of CRCA metal enclosure with sealing arrangments as per EB requirements, 2 MM thickness (powder coated) of minimum size 400mm (W) x 300mm (D) x 500mm (H)along with electrolytic copper bus bar rated for 300A, mounted inside the enclosure with suitable supports, sleeves, and interconnections for incomer and outgoing connections and3mm thick detachable gland plates for 150 Sqmm aluminium cable entry from top/bottom as required. The cable end box shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling, cutting welding painting etc) firmly in the existing wall/ existing base channel as required as per site condition complete in all aspects. 345 Shifting of TNEB Metering Board Three Phase: a)Supplying and fixing of suitable size of teakwood plank for fixing of existing meter and other accessories as required.b) Supplying and fixing of required 03 nos of 63A-100A porcelain fuse unit. c)Supplying and Fixing of copper earth strip of size 19mm X 3mmthick of6`` length for earth connections as reqd. The above complete set has to be mounted on wall. The charge including all interconntions and masonry works etc. d)Re fixingor shifting of Existing Meters (10-60A) with new boards including remitting of necessary charges to TNEB for meter shifting on behalf of CSIR-CECRI and co-coordinating with TNEB officials in all aspects in order to charge the meteringboard complete as required.

Key Value

Document Fees
Refer document
EMD
INR 176355.0 /-
Tender Value
INR 88.17 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail