| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecorecableinsurface /recessedmediumclassPVC conduit,withpianotypeswitch,phenoliclaminatedsheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiringforlight/powerplugwith 2X4sq.mmFRLSPVC insulatedcopperconductorsinglecorecableinsurface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 8 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 9 | Supplying and fixing following piano type switch/ socket on the existingswitch box/coverincluding connections etc.as required. |
| 10 | 5/6 amps switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 13 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 14 | Upto 450 mm sweep |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 16 | SupplyingandfixingPVC batten/angle holderincluding connections etc. as required. |
| 17 | Supplying and fixing 3pin, 5A ceiling rose on the existing junctionbox/woodenblockincludingconnectionsetc.as required. |
| 18 | Installation ,Testing,Commissioningofwallbracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lampsperfitting,completewithallaccessoriesincluding connections etc. as required. |
| 19 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 20 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 21 | 8 way , Double door |
| 22 | 12 way , Double door |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Supplyingandfixingfollowingrating,doublepole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | 40 A |
| 27 | Providing and laying earth connection fromearth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 28 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 29 | Supplying, Installation, Testing and Commissioning of ASHLOK Make SEE brand saf earthing electrode type-19, 50mm dia, length 2 Mtr (short time current- 52.6rms for 1 sec, peak - 125.6) with back fill compound including providing masonary enclosure with cover plate having locking arrangement etc. as required. |
| 30 | Supplying of Surface mounted LED Batten Luminaires with Lamp type 20W LED 6500K, Make: Polycab, Intenso 20W LXS Batten, 220-240V, White or its equivalentas approved by Engineer - in - Charge. |
| 31 | Supplying of Surface/ Wall mounted bulkhead fitting with P65 protection Make: PHILIPS, VistaGlowType : WT140W LED7S CW PSU S1 PC or its equivalentas approved by Engineer - in - Charge. |
| 32 | Supplying & fixing of 10W LED lamps with light output of 950 lumenMake:- Havells or its equivalent to ISI . |
| 33 | Supplying of 5 star, 26W to 35W (BLDC Type) energy saving A.C Ceiling fan, 1200mm sweep for operation of 230V, with all accessories etc as required. Make:- Crompton, Model : Energion High Speed, Color: White or Equivalentas approved by EIC. |
| 34 | Supplying of XLPE insulated, PVC inner sheathed Un-armoured copper cable, 3 core 1.5 sqmm as requiredmake : Havells/Polycab/Anchor or its equivalent to ISI or as approved by Engineer-in-charge. |
| 35 | Supplying of Exhaust Fan 250mm Sweep (Non Mettalic Type) with all accessories etc as required.Make:-Havells, Model: Ventil Air-DX White or itsEquivalent to ISI as approved by EIC |
| 36 | Supplying and fixing T.W Board of 250mm x 300mm x 60mm deep (nominal size) on surface for installation of Energy meter as required. |