| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-09-2025 | Date extension3 | Date | 22-09-2025 |
| 2 | 11-09-2025 | Date extension2 | Date | 12-09-2025 |
| 3 | 04-09-2025 | CSD | Technical Bid | 11-09-2025 |
| 4 | 28-08-2025 | Date extension | Date | 11-09-2025 |
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming , watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming , watering including shoring and strutting etc. complete. (Lift upto 1.50m)ByMechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum,including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming , watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 4 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming , watering including shoring and strutting etc. complete. (Lift from1.5 to3.0m.) By Mechanical Means |
| 5 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum,ramming,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means |
| 6 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming , watering including shoring and strutting etc. complete. (Lift from3.0 to4.50m.) By Mechanical Means |
| 7 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum,ramming,watering including shoring and strutting etc. complete. (Lift from 3.00 m To 4.50 m.) By Mechanical Means |
| 8 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling,ramming , watering including shoring and strutting etc. complete. (Lift from4.50 to6.00m.) By Mechanical Means |
| 9 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum,ramming,watering including shoring and strutting etc. complete. (Lift from 4.50 m To 6.00 m.) By Mechanical Means |
| 10 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 11 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in i millimetre ediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. |
| 12 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent ofclorophyrifosper square metre of surface area covering ten years guarantee on bond paper. |
| 13 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 cement mortardiametre about 30 -60centimetredeep at 15centimetrec/c as close to the wall as possible and to inject 0.5 percent ofaldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. |
| 14 | Filling in plinth and floors with approved excavated material in 15 centimetre . to 20 centimetre . layers including watering and compacting etc. Complete. |
| 15 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15centimetreto 20centimetreincluding watering and compaction etc. Complete. |
| 16 | Disposing of Unwanted/Un Servicable all kind of Material away from Site as directed by Engineer incharge. |
| 17 | Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer) |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trapmetal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/Concrete Batch mixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sandVertical shaft impact (VSI)Grade)(All Floors) |
| 19 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap metal forReinforced cement concretework in foundations likeraft, strip foundations,grillage and footings ofReinforced cement concretecolumns and steel stanchions etc. columns as perdetaileddesignsanddrawingorasdirectedincludingSteelcentering formwork, cover blockslaying/pumping, compactionfinishingtheformedsurfaceswithcement mortar 1:3 of sufficient minimumthicknesstogiveasmoothandevensurfaceor rougheningifspecialfinishistobeprovidedandcuringetc.complete.(Excluding reinforcementandstructuralsteel).withfullyautomaticmicro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete. With fine aggregate (Crushed sandVertical shaft impact (VSI)Grade).(All Floors) |
| 20 | Providingand layingCast in situ/ReadyMix cement concretein M-40 of trap metalfor Reinforced cement concrete Retaining wallin Basement ofrequiredthicknessincludingsteel centering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementand structural steel).withfully automatic micro processor basedProgrammable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete.Withfineaggregate(Crushed sandVertical shaft impact (VSI)Grade).(All Floors) |
| 21 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trapmetal forReinforced cement concretecolumns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to giveasmoothandevensurfaceorrougheningifspecialfinishistobe provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor basedProgrammable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete. With fine aggregate (Crushed sandVertical shaft impact (VSI)Grade)(All Floors) |
| 22 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trapmetal for Reinforced cement concrete beamsandlintelsasperdetaileddesignsand drawings or asdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be providedandcuringetc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor basedProgrammable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete. With fine aggregate (Crushed sandVertical shaft impact (VSI)Grade).(All Floors) |
| 23 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap metal for Reinforced cement concreteslabsand landings as perdetailed designsand drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to giveasmoothandevensurfaceorrougheningifspecialfinishistobe provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor basedProgrammable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sandVertical shaft impact (VSI)Grade)(All Floors) |
| 24 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrapmetal for Reinforced cement concrete chajjaasperdetaileddesignanddrawingsincluding steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbased Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete.Withfineaggregate (Crushed sandVertical shaft impact (VSI)Grade) |
| 25 | Providingand layingCast in situ/ReadyMix cement concretein M-40 of trap metalfor Reinforced cement concrete pardiofrequiredthicknessincludingsteel centering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementand structural steel).withfully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete.Withfineaggregate(Crushed sandVertical shaft impact (VSI)Grade)(All Floors) |
| 26 | Providingand layingCast in situ/ReadyMix cement concretein M-20 of trapmetal forReinforced cement concrete coping to plinth or parapet and sill of doors and windowsmouldedasperdetaileddrawingsorchamferedasapprovedby theEngineer includingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing androughening them if special finish is to be provided and curingcomplete.(Excluding reinforcementandstructuralsteel).withfullyautomatic micro processor basedProgrammable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc.complete.Withfineaggregate(Crushed sandVertical shaft impact (VSI)Grade).(All Floors) |
| 27 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-40oftrapmetal forReinforced cement concreteWaist slab, and steps of staircases as per detailed designanddrawings or as directed including steel centering, plywood/ steel formwork, steelprops,laying/pumping, compaction, finishinguneven and honeycombedsurface withcement mortar 1:3of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc.complete.Withfineaggregate(Crushed sandVertical shaft impact (VSI)Grade).(All Floors) |
| 28 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-40oftrapmetalfor Reinforced cement concrete finsofrequiredthicknessinpositionas shown on thedrawings or as directed by Engineer-in-charge including steel centering, plywood / steelformwork, steel props, laying/pumping, compaction, finishing uneven and honeycombedsurfacewithcement mortar 1:3ofsufficientminimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement,including coverblock) Newlylaid concrete shallbe covered by gunnybag,plastic,tarpaulinetc.withfully automatic micro processor basedProgrammable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete.With fine aggregate (Crushed sandVertical shaft impact (VSI)Grade)(All Floors) |
| 29 | Providing and fixing in position Thermo Mechanically Treated (TMT)- FE - 500 bar reinforcement of various diameters for Reinforced cement concrete pile caps, footings, foundations, slabs,beams columns,canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs,drawingsand schedules. including cutting,bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 30 | Providing secondclassBurntBrickmasonrywithconventional/Indian Standard typebricksin cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.(All Floors) |
| 31 | Providing Autoclaved Aerated Concrete Block masonary ofconformingtoIndian Standard :2185 (Part 3)-1984inextrafine jointing mortaroffixoblockofUltraTechorequivalentin superstructure including striking joints,raking outjointsandscaffolding etc.Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)(All Floors) |
| 32 | Providing Autoclaved Aerated Concrete Block masonaryof conformingtoIndian Standard :2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech orequivalentin Halfbrickthickwallincludingstrikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) with 2 bars horizontal of 6millimetredia at every 3 layers of course. (All Floors) |
| 33 | Providing and fixing of expansion joint system related with floor locationas per drawings and direction of Engineer-In-Charge. The joints systemwill be of extruded aluminum base members, self aligning / self centeringarrangement and support plates etc. as per ASTM B221-02. The systemshallbesuchthatitprovidesfloor tofloor/floortowallexpansioncontrol system for various vertical localtion in load application areas thatacco millimetre odates multi directional seismic movement without stress to it’scomponents.Systemshallconsistofmetalprofileswithanuniversalaluminumbasememberdesignedtoacco millimetre odatevariousprojectconditions and finish floor treatments. The cover plate shall be designedof width and thickness required to satisfy projects movement and loadingrequirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / movesin all directions. The Self - centering arrangement shall exhibit circularsphereendsthatlockandslideinsidethecorrespondingaluminumextrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier MembraneintheJointSystemtohavewatertightjointismandatoryrequirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063).Floor Joint of 100millimetregap.(All Floors) |
| 34 | Providing and fixing of expansion/ seismic joint system of approved make related with wall joint (internal/External wall to wall/ ceiling to ceiling/ wall to corner/ any angle) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an expansion joints system suitable for vertical wall to wall/ wall or ceiling at corner/ ceiling application, with no slipping down tendency amongst the components of the joint system. The joint system shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. No screws shall be visible on centre plate (hidden fasteners). The centre plate can be individually designed to match the adjacent surface and can be printed in same adjacent wall texture. Expansion joint system shall be with all mandatory requirement as per the manufactures design and as approved by Engineer-in-charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of edge preparation, moisture barrier, polyester powder coating (Minimum 50 micron) on aluminium of approved shade and make if required. Expansion joint system shall be as approved for all floor all level including scaffolding etc complete.Internal Wall/ ceiling Joint upto 100millimetregap.. (All Floors) |
| 35 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-in-charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of acco millimetre odating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to acco millimetre odate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).Roof Joint upto 100millimetregap. (All Floors) |
| 36 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the Reinforced cement concretestructures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50millimetre . The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @ 0.70 kg per One Square Metreper coat.(All Floors) |
| 37 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the Reinforced cement concretestructures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc For horizontal surface one coat @1.10 kilogrammeper square metre.. (All Floors) |
| 38 | ProvidingwaterproofinginWater closet andbathincludingbrickbatcobainallposition includingproviding and laying 12 millimetrebedding in cement mortor 1:3 on vergin concreteslabwith waterproofing compound @ 1Kilogramme per bag of cement laying brick bat coba ofrequired thickness incentimetre1:5withwaterproofing compound1Kilogram/bag of cementgroutingandfinishingthetoplayerwith20 millimetre thickbrickbeddingin centimetremortor 1:3 with waterproofing compound 1 Kilogram/per bag ofcement and testing the treatedportionfor48hoursby pondtest and covering ten years\" guarantee onrequisite stamp paper including curing etc. complete. |
| 39 | ProvidingwaterproofbeddingforflooringofBathandWater closet 25 millimetre thickincement mortar1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.(All Floors) |
| 40 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20millimetre . thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetrex 300millimetre . making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.(All Floors) |
| 41 | Providinginternalcementplaster12 millimetrethickinsinglecoatincementmortar1:4 withoutneerufinishto concrete orbricksurfaces,inall positionsincluding scaffoldingand curing etc. complete.(All Floors) |
| 42 | Providingfinecement finish 1.5 millimetre thickover greenplaster surfaceincluding scaffolding curing etc. complete. (All Floors) |
| 43 | Providing and applying Two coats of wall care Putty on Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.(All Floors) |
| 44 | Providing and applying Texture plaster with finishing with texture materialof approved makein 3 to 4 millimeterthickness on previously plastered surface, including PlasterGroove6 millimetrethickness or Tape Grooves 35 to 45millimetrethickness or as required,inallposition including preparing the surface, scaffolding etc. complete.(All Floors) |
| 45 | Providing patti/ band 100 millimetrewide on plastered surface 12millimetreto 15millimetrethick in cement mortar1:3 line and level including neat finishing scaffolding curing etc. complete.(All Floors) |
| 46 | Providing and fixing chicken mesh of 22 gauge, with about 30centimetre . width at the junction of R.C.C members and brick work, of approved quality including fixingmesh in positionby necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.(All Floors) |
| 47 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimetre thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.(All Floors) |
| 48 | Providing and laying machine cut machine Polished Kota stone flooring 25 millimetreto 30 millimetrethick andrequiredwidthinplain/diamondpatternonbedof1:6cement mortar including cement float,filling jointswithneat cementslurry,curing,polishing andcleaningetc.complete. |
| 49 | Providingsills of required material20 millimetreto25 millimetrethick, on a bed of cement mortar 1:4includingcement float, fillingjoints with neat cement slurry, curing, mouldingedges, polishing,cleaning complete.b) Granite (All Floors) |
| 50 | Providing25 millimetre to30 millimetre thickpartitionofpolishedblackkadappastoneslabofapproved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish for Parking Area, External Gallary etc.(All Floors) |
| 51 | Providingandlayinginpositionflooringoftelephoneblack/AmbaWhite/Catbary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18millimetreto 20millimetrethickonbed1:6cementmortarincluding cementfloatsstrikingjoints,pointingin cement mortar1:3 curing and cleaning etc. complete.(All Floors) |
| 52 | Providingandfixingmachinecutmachinepolished18 millimetre to20 millimetre thicktelephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete.(All Floors) |
| 53 | Providingandfixingmachinecutmirrorpolished18 millimetreto20 millimetrethicktelephone blackgranite / AmbaWhite / Catbary brown/RBI red/ OceanBrowngranitestone partition with full moulding the edges etc.complete . Both side polish.(All Floors) |
| 54 | Providing and laying Heavy Duty vitrified mirror / glossy finish tiles decorative typehaving size 590millimetreto 605 millimetrex590 millimetreto 605 millimetreof8to 10 millimetrethicknessandconfirming to IS. 15622-2006(groupBla)ofapprovedmake,shadeandpatternforflooring inrequired position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints, curingandclearing etc. complete.(All Floors) |
| 55 | Providing and laying vitrified mirror / glossy finish tiles having size 590millimetreto 605millimetrex 590millimetreto 605millimetreof 8 to 10millimetrethickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc.complete |
| 56 | Providing and laying Heavy Duty vitrified matt fininsh tileshaving size 590millimetreto 605millimetrex to 605millimetre of 8 to 10millimetrethickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternforflooringinrequiredpositionlaidonabedof 1:4 cement morarincludingneatcementfloat,fillingjoints,curingandcleaningetc.complete. |
| 57 | Providing and laying vitrified matt finish tileshaving size 590millimetreto 605millimetrex to 605millimetre of 8 to 10millimetrethickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternfordadoandskirtinginrequiredpositionfixed in1:4cementmortar including neat cement float, filling joints, curing and cleaning etc.complete. |
| 58 | Providing andfixing in required positionskirting or dado of polishedKotahStone slab 25 millimetre to30millimetre thick fixed on baseon plaster of cement mortar1:4 including cement float,fillingjointswithcementslurry,curingrubbing,polishingandcleaning complete.(All Floors) |
| 59 | Providing and laying Antiskid Ceramic tiles of approved qualityof size 30centimetrex 30centimetreand confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurrycleaning curing etc. complete.(All Floors) |
| 60 | Providing and laying ceramic tiles ofhaving size 30centimetre . x30centimetre . and confirming tocorrespondingI.S.fordadoandskirtinginrequiredpositionwith readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete..(All Floors) |
| 61 | Providing and applying three coats of water proof cement paint of approved manufacture andofapprovedcolourto newplasteredsurfacesincludingscaffoldingifnecessary, cleaning and preparing the surface, watering for two days etc. complete. (All Floors) |
| 62 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaningoil,grease,dirtandotherforeignmatterandsandpaperingasrequiredetc.complete.(All Floors) |
| 63 | Providing andapplying one coatofsealcementprimerofapprovedmanufacture and shed includingscaffoldingpreparingthesurfacebycleaningdirtandotherforeign matters, scrapping if necessary including scaffolding etc. complete.(All Floors) |
| 64 | Providing and applying washable oil-bound distemper of approvedcolour andshade to oldand new surfaces inTwocoat including scaffolding, preparing the surfaces. (excludingthe primer coat.)etc. complete.(All Floors) |
| 65 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetrex 40 millimetrex 5 millimetrewith oil painting, etc. complete.(All Floors) |
| 66 | GI LOUVERS (13*75*13): Providing&FixingofOculus®13*75*13 millimetre louversSystem manufacturedbyM/s.OculusBuildingProductsPvt. Ltd., or Equivalentofapprovedexteriorgradepowdercoating(Singleside)RALcolorconsistingof75 millimetre widex0.5 millimetre TCTlouvershaving100 millimetre (module) c/c with the clear gap of 250 millimetre , length up to 4 meters.The Panel shall be clipped to a baked enameled GI Panel carrier of 20 millimetre wide x 45 millimetredeep x 0.5millimetrethick in standard length of 3 meters. (Vertical Application) (All Floors) |
| 67 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9millimetrewith lock plate of 3.15millimetrethickness reinforced with 35 x 35 x 5millimetreangle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thicknessnotlessthan65 millimetre and3.15 millimetre respectivelywithholdfastarrangements, M.S.Bracketplate300x300x3.15 millimetre minimumsizeandshapewithsquarebar, suspension shaft of minimum 32millimetrediameter, hood cover of M.S. sheet not less than 0.9millimetre thicknessandofanysizeattopandsafetydevicesincludingmechanicalgear operation arrangement consisting of worm gear wheels and worms of high grade cast iron ormildsteelandonecoatofredleadprimeretc.complete.(I.S.62481979)(With mechanical gear) (All Floors) |
| 68 | Providingandfixing900 millimetre highS.S.304GradeStainlesssteelrailingwith40 millimetrediameter and1.5 millimetre thickattop, 40 millimetrediameterand1.5 millimetrethickverticalsupports spaced at 1.5mcenter to center and 8 millimetrethick toughened glass including fabricating ,fixtures, errecting ,necessarywelding,grinding,finishing,buffingto stainless steel pipe etc. complete.(All Floors) |
| 69 | Providing and fixing stainless steel (Grade 304) railing made ofhollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixingtherailingwithnecessary accessoriesandstainlesssteel dashfasteners,stainless steel bolts, etc. of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of engineer in charge (for payment purpose, only the weight of the stainless steel members shall be considered including fixing accessories such as nut bolts, fasteners etc.). 50 millimetre diameterpipe, 1.5 millimetrethickness and weight 1.92 Kilogram per runningmetre.(All Floors) |
| 70 | Providingandfixing40 millimetre diameterand1.5 millimetre thickStainlesssteelhandrailingin S.S.304 Gradeincludingfabricating,fixtures,errecting,necessarywelding,grinding, finishing, buffing to stainless steel pipe etc. complete |
| 71 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15millimetrethick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8millimetrethick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete.(All Floors) |
| 72 | Supply, fixing and installation of 4 millimetrethick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50millimetrethick, total thickness of aluminium composite panels not to be less than 4millimetre , the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50millimetreX25 millimetreX 3 millimetrethick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900millimetreX 1200millimetreand fixed to the building structure as per design through 50 millimetreX50 millimetreX5millimetreMS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate)(All Floors) |
| 73 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metreasperdrawingincludingfixturesnecessaryweldingandpaintingwith onecoatof anticorrosive paint and two coats of oil painting complete.(All Floors) |
| 74 | Providingandfixing90 centimetre x60 centimetreGraniteplateengraving10 centimetre .Height letter, figures including painting the lefters/figures with approved colour and shade complete.(All Floors) |
| 75 | Providing and applyingantipeel paint of approvedmake &approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in twocoats,includingexterioracrylicprimercoat,scaffolding,preparingthe surfaceetc. complete (Heat Reflective Paint). (All Floors) |
| 76 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.(All Floors) |
| 77 | Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEMTilebasedAluminum / GI framing partitionsystemof1800/1200 millimetre ht.madeof75 millimetre thick aluminum / GI frames having two separate race-ways for laying electrical & computer wiring. The wire management shall be through to the race-way to be fitted at bottom of partition other i millimetre ediately below of work top with hook on type raceway cover for easy access of wires.FramestobejoinedbyaluminumconnectorswithM6x16pan-headmachine screw and washer with aluminum post cover. Post cover snap on fashion to be connected on aluminum connector visible aluminium to be in anodized / powdercoated finish.The top exposed sides of the frame and posts should be covered with horizontal/ Vertical trim andcapsmade ofAluminuminanodized/ powdercoated finishin orderto enhance its look.Upper tiles on the partition to be inSoft Boardor Markeror prelaminatedpartical board / Pre-Compressed Board/Compressed Board tile of9 millimetre . thk.,prelaminated partical board lower tiles in laminate finish 9 millimetre . thk. on both the sides .Size :- 1200/1800 millimetre(H)(All Floors) |
| 78 | Providing and fixing 1.5millimetrethick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete.(All Floors) |
| 79 | Providingandfabricatingstructuralsteelworkinrolledsectionslikejoists,channels, angles,tees etc. as per detailed design and drawings or as directed including cutting, fabricating,hoisting, erecting, fixing in position making riveted / bolted/welded connections withoutconnectingplates,bracesetc.and includingonecoatof anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc.complete.(All Floors) |
| 80 | Wall Guard at bottom levelProviding and fixing polyamide vinyl wall guard having vinyl snap on cover (lead free) and rubber spacer of 2 millimetrethickness each to absorb the shocks and aluminum retainer of 2 millimetrethickness that shall be fabricated from 6063-T5 aluminum. Dimensions to be of 100 millimetreheight x 20 millimetredepth. The polyamide vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth. Polyamide Vinyl Snap on cover of 2 millimetrethickness shall be extruded from chemical and stain resistant poly vinyl chloride with the addition of impact modifiers. The system shall also conform to class B1 fire rating, chemical and stain resistance. Rate shall be inclusive of all required accessories like corner piece etc complete (All Floors) |
| 81 | Wall Guard at upper levelProviding and fixing handrail of having vinyl snapon cover (lead free) of 2 millimetrethickness and aluminum retainer of 2 millimetrethickness that shall be fabricated from 6063-T5 aluminum. Dimensions to be of 145 millimetreheight x 85 millimetrewidth and 38millimetregripping diameter. The system shall resist an impact of 45.5 ft-lbs as per ASTM F-476-84. The polyamide vinyl shall not support fungal or bacterial growth. Polyamide Vinyl Snap on cover of .080\" (2 millimetre ) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers. The system shall also conform to class B1 fire rating, chemical and stain resistance.(All Floors) |
| 82 | Corner Guard (internal area)Providing and fixing corner guard having vinyl snap-on cover (lead free) of 2 millimetrethickness and aluminum retainer of minimum 1.4 millimetrethickness that shall be fabricated from 6063-T5 aluminum. Dimensions to be of 76 millimetrex 76 millimetrewings and 90 degrees angle. The polyamide vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth. Polyamide Vinyl Snap on cover of .080\" (2 millimetre ) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers. The system shall also conform to class B1 fire rating ,chemical and stain resistance. (All Floors) |
| 83 | Providing and laying in place 300 millimetrex 300 millimetrex 9.8 millimetrevitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete. (All Floors) |
| 84 | Providing and laying in place 300 millimetrex 300 millimetrex 16 millimetrecement tactile directional and warning tiles (for a person with visual impairment)of the approved brand and make and specified colour for outdoor floors such as footpath, courtyard, multimodals location etc. laid on 20 millimetrethick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement with matching pigments etc. complete as per direction of engineer in charge |
| 85 | SupplyandInstallationoftranslucentroofwithDPIFluxstandingseammulticell polycarbonatepanelsystem.ThesystemwithcompleteassemblyofcoextrudedUV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system ofmin12 millimetrethickof900 millimetre(min.)widthwithangular daylightingconcept.Panelsshall haveminimumsixlayerswithtrussbridge designfor higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MSstructure(willbepaidSeparately)with3OneNumbersself-drillingscrews& trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required.PanelshallbefixedoverMSstructuralsteel/MSpurlin(paidseparately) conforming to the detail technical specifications as per approved architectural drawings. Trainedandfactoryauthorizedlabourwithsupervisiontocompletetheentirepanel installationasperdrawing&directionoftheengineeringincharge.Colour:Asper Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12 millimetrethick panels shall be used for a roofing height of upto 15 mtrs.(All Floors) |
| 86 | Providing & Fixing of Luxalon Aluminium Aerofoil 200 Plain Fixed Louver manufactured by M/s.Hunter Douglas India Pvt.Ltd. or equivalent make of required length (above 2.0 meter) |
| 87 | Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600millimetrex 450 millimetresize as per detaileddrawing including vertical bothside polished kadappah stone 25 to 30millimetrethick supports with kadappahtop 35 to 40millimetrethick and polishedgranite16to20 millimetretopwithsidestripsofgranite atfront andbothsidesof platform raised with two verticalgranitesupports15 centimetre heightandtopgraniteof75 x40 centimetre includingcutting,opening forsink ofrequired size in kadappahas well as granite etc. complete. (Platform top size 5.00 metre x 0.60 metre and height is 0.75 metre) (All Floors) |
| 88 | Providingandapplying2Coatsofhighqualityacryliccopolymermattapproved lowVOCemulsionpaintofapprovedshadethatgivessmooth,flatandwashableand durable finishing of approvedmake. Paint should have good flow levelling property with good colourretention and incanantibacterialproperty. Paint hastobeapplied on smoothanduniformsurface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC acrylic copolymer based primer sealer that has incan antibacterial property.Theworkactivityshouldcoverallaspects ofapplyingpaintsfromsurface preparation,fillingtoerectinganddismantlingof scaffolding,finishingthesurfaceetcas directed by Engineer in charge.(All Floors) |
| 89 | Structural Glazing Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessaryforfabricationofextrudedaluminiumframework.Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.(All Floors) |
| 90 | Structural Glazing Designing, fabricating, testing, protection, installing and fixing inposition semi(grid)unitizedsystemofstructuralglazing(withopenjoints)for linear as well as curvilinear portions of the building for allheights and alllevels, including:(a) Structural analysis & design and preparation of shop drawings forthe specified design loads conforming to IS 875 part III (the systemmust passedtheprooftestat1.5timesdesignwindpressurewithoutany failure), including functional design of the aluminum sections forfixing glazingpanelsofvariousthicknesses,aluminiumcleats,sleevesand spliceplatesetc.gaskets,screws,toggles,nuts,bolts,clampsetc., structuralandweathersiliconesealants,flashings,firestop(barrier)-One Cubic Metre -smoke seals, microwave cured EPDM gaskets for watertightness, pressureequalisation&drainageandprotectionagainstfirehazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised /Aluminium alloy of 6005 T5 brackets of required sizes, sections andprofiles etc. to acco millimetre odate 3 Dimentional movement for achievingperfect verticality and fixing structural glazing system rigidly to theReinforced cement concrete / masonry/structural steelframeworkofbuildingstructureusingstainlesssteelanchor fasteners/ bolts, nylon seperator to preventbimetallic contacts with nuts and washers etc. of stainless steelgrade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant andonepartweathersiliconesealantcompatiblewiththestructuralsilicone sealant of required bite size in a clean and controlled factory/ workshopenvironment,includingdoublesidedspacertape,settingblocks and backer rod, all of approved grade, brand and manufacture,as per the approved sealant design, within and all around theperimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet1millimetrethick and of sizes, shapes and profiles, as required as per thesite conditions,tosealthegapbetweenthebuildingstructureandallits interfaces with curtain glazing to make it watertight.(e)Makingprovisionfordrainageofmoisture/waterthatentersthe curtain glazing system to make it watertight, by incorporating principles ofpressureequalization,providingsuitablegutterprofilesatbottom(if required),makingnecessaryholesofrequiredsizesandofrequired numbers etc. complete. This item includes cost of all inputs of designing, labourforfabricatingandinstallationofaluminiumgrid,installationof glazedunits,T&P,scaffoldingandotherincidentalchargesincluding wastagesetc.,enablingtemporarystructuresandservices,cranesor cradles etc. as described above and as specified. Theitemincludesthecostofgettingallthestructuralandfunctional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mockupsatsite,costofallsamplesoftheindividualcomponentsfor testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning andprotection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing havingall the performance characteristics etc. all complete as required, asper the Architectural drawings, as per item description, as specified,as per the approved shop drawings and as directed by the Engineer-in-Charge.Note:-1.Thecostofprovidingextrudedaluminiumframes,shadowboxes, extruded aluminium section capping for fixing in the groovesof the curtain glazing and vermin proof stainless steel wire meshshall be paid for separately under relevant items under this sub- head. However, forthepurposeofpayment,onlytheactualareaofstructuralglazing (including width of grooves) on the external face shall be measured in One Square Metre . up to two decimal places.Note:-2. The following performance test are to be conducted onstructural glazing system if area of structural glazing exceeds 2500 One Square Metrefrom the certified laboratories accreditated by NABL(NationalAccreditation Board forTestingandCalibrationLaboratories),DepartmentofScience& Technologies, In diameterCost of testing ispayable separately.TheNITapprovingauthoritywilldecidethenecessityoftestingonthe basis of cost of the work, cost of the testand importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4.StructuralPerformanceDeflectionanddeformationbystaticair pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50millimetre 5. Seismic Movement Test (upto 30millimetre ) as per AAMA 501.4-09testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240kpa (35psi) upto 2000 ml. (All Floors) |
| 91 | Providing,assemblingandsupplyingvisionglasspanels(IGUs) comprisingofhermetically-sealed6-12-6 millimetre insulatedglass(double glazed) vision panel units of size and shape as required and specified, comprisingofanouterheatstrengthenedfloatglass6 millimetre thick,of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6millimetrethick, spacer tube 12millimetrewide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the requiredperformances,aspertheArchitecturaldrawings,asperthe approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in One Square Metre .(i)Colouredtintedfloatglass6 millimetre thicksubstratewithreflectivesoft coating on face # 2, + 12millimetreAirgap + 6millimetreHeat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. (All Floors) |
| 92 | Providing and fixing vision panel made out of 5millimetrethick toughen glass of any shape any size in all type of flush doors (for non fire rated door). Glass shall be fixed with superior class teak wood beading on both side the door of required size as shown in drawing and direction of Engineer-in-charge. Rate shall be inclusive of the cost of making opening in door, provision of glass, superior class teak wood beading both side, extra batten support required around periphery of opening, cost of PU polishing etc complete. Installed glass area shall be measured for payment without considering any wastage. (All Floors) |
| 93 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35 millimetrethick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202–1966(Revised)includingapprovedfaceveneersonbothsides,withoutglazingand venetians including mat finish stainless steelfixtures and fastening, stoppers and finishing withfrenchpolishing etc.(Excluding doorframe)(Sample to be got approvedfrom Ex. Engineer before use) CommercialHard Wood shutter. (All Floors) |
| 94 | Providing and fixing 34millimetrethick moulded door shutter consisting of solid core single leaf flush door of 30millimetrethickness lipped with 15millimetre( 5 millimetrex 3) thick x 30millimetrewidth on onestyle and top rail and 10millimetre(5 millimetrex 2) thick x 30millimetrewidth on other style and bottom rails. The inner panels laminated with 2millimetrethick termite proof, water proof and fire resistant mouldedPoly vinyl chloridesheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2millimetreplain and /or pre lamPoly vinyl chlorideon other side using rubber adhesive on flush door and solvent cement adhesive on thePoly vinyl chloridelipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete. (All Floors) |
| 95 | Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at NationalTest House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\"Non Combustible by Nature\"). a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st classMalaysian Hardwood Frame densified (810 Kilogram/One Cubic Metre ) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70millimetrespray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimetrex 4 millimetreaffixed in the slit of the Frame for fire and smoke sealing, etc. complete. (All Floors) |
| 96 | Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at NationalTest House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\"Non Combustible by Nature\").b)Shutter : Supplying & Fixing of 55 millimetrethick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8 millimetreCalcium Silicate boards over Chemically treated (with Fire retardant chemicals in vacOne Cubic Metrepressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/One Cubic Metre ) frame work of 100x32millimetrewith 32 millimetrethick infill of ceramic fiber (density 128 Kilogram/One Cubic Metre ), vermaculite mix faced with 3 millimetreFire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10 millimetre x4 millimetreaffixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. (All Floors) |
| 97 | c) Vision Panel:2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10millimetreinside the shutter on all sides with U- glazing. An additional insulated powdercoated \"Z\" channel of 16 swg MS sheet to be fixed for reinforcement of the joints. (Any size 300x200,450x120,600x100 millimetre ) (All Floors) |
| 98 | Door Closure: (For 2 Hr fire Rated EN-3 Door Closure) Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900 millimetre ) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction &satisfaction of Engineer -in Charge including all taxes & incidental charges. (All Floors) |
| 99 | 12\"SS Handle: (For 2 Hr fire Rated 12\"SS Handle) Supplying, fitting & fixing Stainless Steel \"D\" or \"H\" type of size 300millimetrex 19millimetretubularHandle with Grade 304, CE certified, marked & conforming to EN - 1154 of approvedquality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnumetc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes & incidental charges. (All Floors) |
| 100 | Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5millimetrethick float glass etc. complete. a) With colour anodizing Note While arriving at the rateofitemofitem weight at 6.90 KilogrammeOne Square Metre is considered. (All Floors) |
| 101 | Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75 millimetre, 3.18millimetrethick and shutter comprising of powder coated section having bottom and lock rail of size 150millimetrex 44.5millimetrex 3.00millimetrethick top rails47.62 x 44.45millimetrex 3.00millimetrethick , vertical style 47.62 x 44.45millimetre , 3.00millimetrethick andfor shutter plain glass panes 5millimetrethick for top panels and 12 millimetrethick both sidelaminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark, heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy dutyconcealed lock, necessary beading, glazing clips,Poly vinyl chloridegaskets, 250 millimetrelength aluminium tower bolts, 150 millimetre diameterpad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete (All Floors) |
| 102 | Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/ Ocean Brown granite stone of 18 to 20millimetrethick for door frame/ dado/ window boxing etc.Oncement mortar 1:6includingfillingjointswithpolymerbasefillerOne Number ing/mouldingthe sharp edges wherever necessary, curing,etc. complete.(All Floors) |
| 103 | Providingandfixing45 centimetre widemildsteelladderof40 millimetre x6 millimetre mildsteelflat stringers andstepsof18 millimetrediameter mildsteelbarforwatertankincludingfixingit in (1:2:4) M-15cement concrete block 60 centimetrex 30 centimetrex 30 centimetreand painting the laddercomplete.(Anti Corossive Paint) (All Floors) |
| 104 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary ha millimetre er drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s reco millimetre endations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10millimetredia 200 millimetredepth. (All Floors) |
| 105 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary ha millimetre er drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s reco millimetre endations. The adequate diameter and embedment of rebars to bedecided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -16millimetredia 320 millimetredepth.(All Floors) |
| 106 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary ha millimetre er drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s reco millimetre endations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -25 millimetredia 500 millimetredepth. (All Floors) |
| 107 | Providing and wet drilling accurate and clean holes of specified diameter in Reinforced cement concretewalls, slabs, beam or any other Reinforced cement concretemember without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer-in-charge. Core cutting - Up to 52millimetre diameter |
| 108 | Providing and wet drilling accurate and clean holes of specified diameter in Reinforced cement concretewalls, slabs, beam or any other Reinforced cement concretemember without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer-in-charge. Core cutting - Beyond 52millimetre diameterup to 102millimetre diameter .(All Floors) |
| 109 | Providing and wet drilling accurate and clean holes of specified diameter in Reinforced cement concretewalls, slabs, beam or any other Reinforced cement concretemember without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer-in-charge. Core cutting - Beyond 102millimetre diameterup to 202millimetre diameter. |
| 110 | Providing in position rigidPoly vinyl chloridepipe sleeves of 6 kilogramme per centimetre 2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 metre). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge.Poly vinyl chloridesleeve - 200millimetreDiameter. (All Floors) |
| 111 | Providing in position rigidPoly vinyl chloridepipe sleeves of 6Kg/ centimetre 2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 metre ). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge.Poly vinyl chloridesleeve - 160millimetreDiameter. |
| 112 | Providing in position rigidPoly vinyl chloridepipe sleeves of 6 kilogramme per centimetre 2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 metre). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge.Poly vinyl chloridesleeve - 110millimetreDiameter. (All Floors) |
| 113 | Providing in position rigidPoly vinyl chloridepipe sleeves of 6 kilogramme per centimetre 2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge.Poly vinyl chloridesleeve - 75millimetreDiameter. (All Floors) |
| 114 | Providing in position rigidPoly vinyl chloridepipe sleeves of 6Kg/ centimetre 2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-chargePoly vinyl chloridesleeve - 50millimetreDiameter. (All Floors) |
| 115 | Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400millimetre . Std Sizes (W x D x H): 900millimetrex 1550millimetrex 2400millimetre , (Height is including 100millimetregap from bottom) Door Width- 600millimetre ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure > 5 MPa and temperature >120° C, All doors will be of single colour and made of 18millimetrethick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12millimetrethick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete. (All Floors) |
| 116 | Providing of Lead Lined Door system with 120x60millimetreHardwood Frames, interlayered with 3 millimetrelead and 44 millimetreSolid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type), interlayered with 3 millimetrelead with prior approval of concerned Superitending Engineer. a) Door Frame: Providing Frames for Lead Lined door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70millimetrewith 45 millimetrethick two layered 3 millimetreLead Line Sheets being overlapped from either side, spray quoted with 2 coats of Enamel paint after one coat of white wood primer of minimum 200 micron etc. complete as per direction of Engineer in Charge. (All Floors) |
| 117 | Providing of Lead Lined Door system with 120x60millimetreHardwood Frames, interlayered with 3 millimetrelead and 44 millimetreSolid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type), interlayered with 3 millimetrelead.b) Shutter: Supplying of \" 44 millimetreSolid core flush door shutters conforming to the I.S.specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32 millimetreWooden structure of 1st class Hardwood or Pinewood of at least 50 millimetrewidth, top and bottom rails of 75 millimetrewidth, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3 millimetreHDF & other side 3 millimetrelead & 6 millimetreBWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron.(All Floors) |
| 118 | Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries orReinforced cement concretebattens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : From Sill Level to Slab Level External |
| 119 | Providing & Fixing inpositionAcoustical Doorsalong with150x150 millimetreteakwood frame, doors made from 50 millimetreTeak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50 millimetrethick and 3 millimetreTecsound from both sides, 12 millimetrewaterproof ply & veneer from both sides , including 150 millimetreheavy duty SS hinges (Geze / Dorma or eq.)4 no each leaf,with Door-closer (Dorma / Geze or eq.)including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete |
| 120 | Providing & Fixing in position, Acoustical Ceiling made from Rigitone 8/18 perforated panels on approved heavy duty G.I. frame, ceiling channels at 300 c to c, & intermediate channels not more than 1200 c to c, suspended with Hangers from Roof, in front of 1000 Gsm synthetic wool 50millimetrethick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishingetc complete. (All Floors) |
| 121 | Providing & Fixing in position, Acoustical Panelling made from 12 millimetrewp Ply wood & 1.5 millimetrelaminateon,50 x50millimetreSal-wood frame of600x 600c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50millimetrethick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings /finishing-items/paint&Scaffolding,asperArchitectural&AcousticalDesign& Instructions & Complete in all aspects.including all materials labour,finishing etc complete .(All Floors) |
| 122 | Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38 millimetreround AluminiumchannelwithBlackoutfabric&teltingwithchain(Ball)systemwithall necessaryfixturesandfittingetc.complete.(All Floors) |
| 123 | PRIVIDINGAND FIXINGANTIMICROBIALACOUSTICALFALSE CEILING:Bioguard Mineral Fibre Acoustical Suspended Ceiling System with 19 millimetrethick Acoustics Microlook 90 Edge Tiles with 15 millimetreface exposed grid. The tiles shall have smooth bright laminatedvisualwithHumidityResistance(RH)of99%,NRC0.7(Averagevalueof Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTME-1477,Thermal Conductivity k=0.052-0.057W/mK,ColourGlobal White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTM E 84with 19 millimetre SquareTegular/Microlook90˚edgeand8 millimetre dropinmodulesizeof600x 600 millimetre ./ 600x1200 millimetre . The scrim on the face of the tile shall be cleanable, washable up to 500 cycle as per ASTM D-4828 and resistant to disinfectants. The tile shall be treated with Anti Microbial coating on the face of the tile to achieve cleanroom classification of class5(Class100)asperISO14644-1andsuitablefor zone4areahavingpartical emissionundernormalconditionsofISO5,DecontaminationClassofCP10and Bacteriological Cleanliness Class B1 for specific strains as per NF S 90-35:2003 The tile shall have a rating of8or above (face) fortests conductedfor Resistance to growthof Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, withRecycledcontentof35%havingVOCandFormaldehydeemissionratelessthan 0.1 mg/m2/hr.ThetileshallhavecertificationsfromGRIHAandGreenProthereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on 15millimetrewide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200millimetre& 600millimetreCross Tees with a web height of 38 millimetre(all sections). The deflection loading of the system shall be 12.5 kilogramme per square metre(as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15 kilogramme per metre . (All Floors) |
| 124 | Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595 millimetrex 595 millimetrehaving 15 millimetrethick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600 millimetremade from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6 millimetrereveal profile (white/black), wherein, main T runner of size 42 millimetre x14 millimetrebetween main tee 600 millimetrecenter-tocenter and secondary cross T of size 33x14x0.43 millimetrethick of length 600 millimetrelong spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200 millimetre x600 millimetreresting on periphery wall Profile wall section 19 millimetre(7+7) x 19 millimetre x0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6millimetreof required length fixed to the ceiling with 6 millimetredia and 50 millimetrelong dash fastener, 4 millimetredia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8 millimetrespaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings and as per The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bendingcapability. All border cross tee/main beam shall be levelled using perimeter fill. INSTALLATION: To comprise main runner spaced at 1200 millimetresecurely fixed to the structural soffit using suspension system (specifications above) at 1200 millimetremaximum. The First/Last suspension system at the end of each main runner shall not be greater than 450 millimetrefrom the adjacent wall along with the first and the last main beam shall be at less than 600 millimetrefrom the wall. Flush fitting 1200 millimetrelong cross tees to be interlocked between main runners at 600 millimetreto form 1200 x 600millimetremodule. Cut cross tees longer than 600 millimetrerequire independent support. 600 x 600 millimetremodule to be formed by fitting 600 millimetrelong flush fitting cross tees centrally between the 1200millimetrecross tees. Perimeter trim to be wall angles of size 3000x19x19 millimetre , secured to walls using screws at 450 millimetrecentre to centre maximum. Installation shall be carried out as per Manufacturer reco millimetre ended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5millimetreof 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7 millimetrethick Grade 1 C55 galvanized spring steel of dimension 100 x 20 millimetreand 4millimetreaquiline wire to be used for level adjustment during installation purpose in main runners). (All Floors) |
| 125 | Providing and fixing in position Gypsum board false ceiling with 12.5millimetrethick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50millimetremaximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. (All Floors) |
| 126 | METAL BAFFLE CEILING : Providing & fixing of horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black & White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5 at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U- profile of 20 x 30 x 3700 millimetre(Thk-1.5 millimetre ) having slots in module of 25 millimetreto keep baffles at an on-center spacing in multiples of 25 millimetre . Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5 millimetre& 28x6.5 millimetrerespectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve . (All Floors) |
| 127 | uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L)millimetreand is rolled form from 1.5 millimetrethick mild steel with a powder coating thickness of 60- 80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. (All Floors) |
| 128 | Providing and fixing 2 hr fire rated 122 millimetrethick double layered dry wall partition system of approved make which includes (on both faces/ elevations) inner layer of tapered edge minimum 12.5 millimetrethick Fire Resistant Gypsum Board having density minimum 790 kg/m3 (conforming to IS 2095 Part 1 : 2011/ EN520::2004, TYPE-F/ ASTM C1396, TYPE X) and outer layer of tapered edge 12.5 millimetrethick calcium sulphate dihydrate encased in high gsm paper liners with glass fibers and other additives for enhanced the fire, acoustics and impact performance, third party EPD Verified as per ISO 14025, having minimum density 900 kg/m3, with maximum allowable point load on single board 25 kg to 30kg without any ply backing, complies with BS EN 520:2004 – Type A, F, D, R, I, Thermal Conductivity: 0.24 w/mºK, Thermal resistance: 0.05 m2 K/w.Framing system - GI framing system consists of Close stud/ C stud of size approximate 70 x34x36x 0.5 millimetreconfirming to IS 513 having Y/S-minimum 230 Mpa, and Finish - AZ150 (IS 15961). Stud shall be placed at 600 millimetrec/c in 72x32x32x0.5 millimetre(approx.) floor channel and 72X32x32x0.5millimetreceiling channel. Floor & Ceiling channel is anchored to the floor & ceiling using zinc coated Rawl plugof size Ø8x45 millimetreand having Pull out Load -7.5 kN/ anchor fasteners of required capacity as per manufacturer\"s specification at 600 millimetrec/c. Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. Noggin channel of 70x40x0.5 millimetrehas to be provided at the horizontal joints of the two boards and top of the board in case the top is not going up to the ceiling channel. All frame members shall be connected to each other by using metal screws. 50 millimetreRock wool slab of density 24kg/m³ shall be placed in metal framework. Glass wool holding clip should be used to hold Glass wool slab in its position. (All Floors) |
| 129 | Providing and fixing in position frames/ shutter for any type of aluminium work like aluminium door, composite door-window, window (sliding, openable, side hung, top hung, fixed etc.), casement window, aluminium partition, aluminium fixed louvers, fixed window with any type of aluminium sections of make Jindal/ Indal/ Hindalco as per approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors/ all levels/ all heights/ all shapes/ all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge.Rate shall be inclusive of providing aluminium sections (conventional and/ or Euro-profile sections), cutting, fabrication, errection and fixing to the best workmanship manner, including1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame;2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatiblemicrowave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI or equivalent for fixing the frame assembly to the Reinforced cement concreteor masonry surfaces. Minimum 1 anchor fastener shall be used for every 600millimetrelength of section for stability of frame. 5) 10 millimetreGI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4 millimetrethick solid aluminium corner cleat of full thickness of sectionfor connecting style and horizontal rails; 6) providing and fixing packing at every 600 millimetrec/c of average 6millimetrecompact sheet of width (equal to section width less 30 millimetrefor backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10millimetrethickness of approved make and color and then sealing the remaining gap with |
| 130 | neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required but excluding. 1) necessary hardware; 2) Glazing or panelling material and shutter.Shop drawing shall be prepared and get approved from the consultants before procurement of material by the contractor. Work shall carried out as per the approved shop drawings and approved sample. Actual weight of installed Aluminium sections which are visible shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. (All Floors) |
| 131 | EXTERNAL WORK |
| 132 | Excavationforroadway inearth, soil ofall sorts,sand,gravel orsoft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.(All Floors) |
| 133 | Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20 centimetre . to 30 centimetre . thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from departmental Land)(All Floors) |
| 134 | Excavationforcatch/sidewatergutterinallsortsofsoilstothespecifiedsection including stacking theexcavatedstuffinaregularbundanddisposingofunsuitableor excess stuff as directed all sorts of soils. (All Floors) |
| 135 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader/ Paver on prepared surface, mixing by mix in placemethod with rotavator at Optimum moisture content, and compacting with vibratory roller to achieve thedesired density, complete as per clause 401 -- By Mix in Place Method and Grading - III Material (All Floors) |
| 136 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/Vertical shaft impact (VSI)grade finely washed crushed sand)conforming to IS: 383, the size of coarse aggregate not exceeding 25millimetre , , cement content not to be less than 150 kg/ One Cubic Metre , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub- grade surface if required etc. complete. with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer) etc. complete. (All Floors) |
| 137 | Providing and laying in-situ M-35 Grade unreinforced plain cement concrete pavement with max 20% fly Ash ( Fly-ash upto 20% by weight of Cement) over a prepared sub basewith 43 grade cement , coarse and fine aggregate ( natural sand/Vertical shaft impact (VSI)grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixeras per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and grades as directed by Engineer-in charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80millimetreat bottom and 40millimetreat top with depth of 75 millimetreand maintaining the same throughout curing period by any other method approved by Engineer-in-charge.(All Floors) |
| 138 | ProvidingandfixingfactorymadeHydraulicallypressedMechanicallyvibratedand compactedprecastinterlockingcementconcretepavingblocks100 millimetre thickinM-50 gradeofapprovedsizeandshapeforCitystreetsandroadswithhighvolume/heavy traffice as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading andstackingasdirected,layingpavingblocksinpositionoverpreparedbedofnatural sand/crushedsandof50 millimetre thicknessincludingnecessaryexcavationinallstratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete. (All Floors) |
| 139 | Supplying and fixing of Swareflex or equivalent Metal Road studs with shank, made of Die-cast Aluminum alloy molded body with the size of 100*100*19.8millimetre , shank size 50 millimetre , having reflective panels of 34 glass reflective elements embedded in plastic and 19 degrees tilted to provide the highest reflectivity having reflective panels in yellow, red and white plastic with yellow, red, white or green glass elements. The weight of Aluminum stud should be not less than 370 grams. The studs shall have a compressive strength test certificate of 40 tons in accordance with ASTDM D 4280-04 and successfully passing retro reflectivity test as per EN 1463 part 1 & part 2, from a reputed international laboratory . The bidder shall attach a product warranty certificate against Breakage and loss of reflectivity from the manufacturer for 3 years from installation. The fixing of road studs shall be done by using a reco millimetre ended Two Component Epoxy after drilling 60millimetre hole on the road for the shank to go inside. (All Floors) |
| 140 | Providing and applying Cold plastic paint two component rolled on surfacing material solvent free,high build two pack seamless,tough,skid resistant,material with has property of attaining 2.00 millimetrethickness in single coat application white(or as required colour )based on glass and colour retaining acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. complete. (All inclusive on bitumen or concrete surface) work shall carried out as per IRC 35-2015 clause 2.2) (All Floors) |
| 141 | Providing and laying Neelgiri/Mexican grass turf with earth 50 millimetreto 60 millimetrethickness of existing ground prepared with proper level andrammingwith required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till t(All Floors) |
| 142 | Preparation and plantation of required variety of trees including excavation pit size 0.6 x0.60 x0.60, supplying on-site fresh Garden soil and well decomposed Farm Yard Manure FYM, mixing garden soil & manure, Filing fresh garden soil and manure in excavated area with maintenance of newly planted trees for the period 36 months till well established including mortality of plant materials, material supply on site must be approved by Horticulturist / Garden in charge & should be certified by competent authority. etc complete. (All Floors) |
| 143 | WATER SUPPLY & SANITARY WORKS |
| 144 | Providing and fixing sink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) (All Floors) |
| 145 | Providing and fixing Chromium platedBIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.(All Floors) |
| 146 | Providing and fixing Hand shower (health faucet) with8 millimetrediameter 1mlongflexibletube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in Charge. (All Floors) |
| 147 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) (All Floors) |
| 148 | Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) (All Floors) |
| 149 | Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 millimetresize with pillar cock, Chromium plated Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180millimetrethick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.(All Floors) |
| 150 | Providing and fixing Table top white wash basin of size 120x635x405 millimetrerubber plugs and brass chain, with pillar cock, Chromium plated Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. (All Floors) |
| 151 | Providing and fixing white Opal series European type wall-hung, ofsize 400millimetrex 370millimetrex 575 millimetrewith approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 millimetredia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.(All Floors) |
| 152 | Providing and fixing Orissa Pan of size 580x445x260millimetrewith approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 millimetre diameterC.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. (All Floors) |
| 153 | Providing and fixing Chromium plateda 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (All Floors) |
| 154 | Providing and fixing white glazed urinal of size710x460x300 millimetrewith sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetrediameterPoly vinyl chlorideflush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete. (All Floors) |
| 155 | Providing and fixing 15 millimetredi ameterPoly vinyl chlorideAqua kraft type of approved makesuper jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete |
| 156 | Providing and fixing wall-hung white wash basin of size 470x575x190 millimetreofapproved make half pedestal, pillar cock, Chromium platedAngular stop cock, long thread continental including S.S. bottle trap of having necessary pipe connections up to the outside face of the wall.etc complete. (All Floors) |
| 157 | Providing and fixing 450 millimetrex 550 millimetresize superior type Belgium mirror with 16 millimetre diameternickel plated towel rod etc. complete. (All Floors) |
| 158 | Providing and fixing partition with kadappa stone of all sizes and 25millimetrethick polished on both side and edges to original including fixing in position in cement mortor 1:4 curing polishing, cleaning etc complete. (All Floors) |
| 159 | Providing and fixing chromium plated towel rod 16millimetredia and 75centimetre . in length including all accessories complete. (All Floors) |
| 160 | Providing and fixing stainless steel sink of size 600 x 510 x 200millimetreincluding coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. (All Floors) |
| 161 | Providing and fixing Chromium platedAngular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.(All Floors) |
| 162 | Providing and fixing Glass self 125millimetrewide and 600millimetrelong with necessary chromium plated brackets providing teak wood gutties etc. complete. (All Floors) |
| 163 | Providing and fixing on walls/ ceiling/ floor 15 millimetre diameter Chlorinated Polyvinyl chloridepipe with necessaryfittings,remakinggood the demolished portion etc.complete.Including removing existingpipeline if necessary and conveying and stacking the sameas directedetc. complete. (All Floors) |
| 164 | Providing and fixing on walls/ ceiling/ floor 20 millimetre diameter Chlorinated Polyvinyl chloridepipe with necessaryfittings,remakinggood the demolished portion etc.complete.Including removing existingpipeline if necessary and conveying and stacking the same as directedetc. complete. (All Floors) |
| 165 | Providing and fixing on walls/ ceiling/ floor 25 millimetre diameter Chlorinated Polyvinyl chloridepipe with necessaryfittings,remakinggood the demolished portion etc.complete.Including removing existingpipeline if necessary and conveying and stacking the sameas directedetc. complete. (All Floors) |
| 166 | Providing and fixing on walls/ ceiling/ floor 32 millimetre diameter Chlorinated Polyvinyl chloridepipe with necessaryfittings,remakinggood the demolished portion etc.complete.Including removing existingpipeline if necessary and conveying and stacking the sameas directedetc. complete. (All Floors) |
| 167 | Providing and fixing on walls/ ceiling/ floor 40 millimetre diameter Chlorinated Polyvinyl chloridepipe with necessaryfittings,remakinggood the demolished portion etc.complete.Including removing existingpipeline if necessary and conveying and stacking the sameas directedetc. complete. |
| 168 | Providing and fixing on walls/ ceiling/ floor 50millimetre diameter Chlorinated Polyvinyl chloridepipe with necessaryfittings,remakinggood the demolished portion etc.complete.Including removing existingpipeline if necessary and conveying and stacking the sameas directedetc. complete. (All Floors) |
| 169 | Supplying and erecting ISI mark GI pipe 65 millimetre .dia‘C”class position with accessories complete. Specification no. CW-PLB/GP-(All Floors) |
| 170 | Supplying and erecting ISI mark GI pipe 80millimetre .dia‘C”class position with accessories complete. Specification no. CW-PLB/GP(All Floors) |
| 171 | Supplying and erecting ISI mark GI pipe 100 millimetre .dia‘C”class position with accessories complete. Specification no. CW-PLB/GP(All Floors) |
| 172 | Providing and fixing screw down for 25millimetre diameterwheeled stop tap of brass including necessary sockets/union nut complete. (All Floors) |
| 173 | Providing and fixing screw down for 32millimetre diameterwheeled stop tap of brass including necessary sockets/union nut complete. (All Floors) |
| 174 | Providing and fixing screw down for 40millimetre diameterwheeled stop tap of brass including necessary sockets/union nut complete. (All Floors) |
| 175 | Providing and fixing screw down for 50millimetre diameterwheeled stop tap of brass including necessary sockets/union nut complete. (All Floors) |
| 176 | Ball cock for 15 millimetre diameter . (All Floors) |
| 177 | Ball cock for 25 millimetre diameter(All Floors) |
| 178 | Ball cock for 32millimetre diameter(All Floors) |
| 179 | Ball cock for 40millimetre diameter(All Floors) |
| 180 | Providing and fixing 50 millimetrediameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber] (All Floors) |
| 181 | Providing and fixing 100 millimetrediameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock.[Without chamber]. (All Floors) |
| 182 | Supplying and erecting 50millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV(All Floors) |
| 183 | Supplying and erecting 65millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV (All Floors) |
| 184 | Supplying and erecting 75/80millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV(All Floors) |
| 185 | Supplying and erecting 100millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV(All Floors) |
| 186 | Supplying and erecting 150millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV(All Floors) |
| 187 | Supplying and erecting 200millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV(All Floors) |
| 188 | Supplying and erecting non return valve 65millimetredia in position made of gun metal complete. (All Floors) |
| 189 | Supplying and erecting non return valve 80millimetredia in position made of gun metal complete. (All Floors) |
| 190 | Supplying and erecting non return valve 100millimetredia in position made of gun metal complete . (All Floors) |
| 191 | Providing andfixing 40millimetre . dia Ball cock medium type withPoly vinyl chloridefloat including sockets and necessary fittings and tested as per municipal requirements etc. complete. (All Floors) |
| 192 | Providing and making ISI Mark ferrule connection of 25 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (All Floors) |
| 193 | Providing and making ISI Mark ferrule connection of 50 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (All Floors) |
| 194 | Supplying and erecting 100millimetredia cast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV.(All Floors) |
| 195 | Supplying and erecting 100millimetredia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS .(All Floors) |
| 196 | Supplying and erecting 12/16millimetre(ID/OD) Chlorinated polyvinyl chloride pipe (Chlorinated Polyvinyl chloride ), thickness 1.7millimetreconforming to IS 15778 (CTS Series) with necessary Chlorinated Polyvinyl chloridefittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV. (All Floors) |
| 197 | Supplying and erecting 16/20millimetre(ID/OD) Chlorinated polyvinyl chloride pipe (Chlorinated Polyvinyl chloride ), thickness 2.0millimetreconforming to IS 15778 (CTS Series) with necessary Chlorinated Polyvinyl chloridefittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV. (All Floors) |
| 198 | Supplying and erecting 20/25millimetre(ID/OD) Chlorinated polyvinyl chloride pipe (Chlorinated Polyvinyl chloride ), thickness 2.6millimetreconforming to IS 15778 (CTS Series) with necessary Chlorinated Polyvinyl chloridefittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV. (All Floors) (All Floors) |
| 199 | Supplying and erecting 25/32millimetre(ID/OD) Chlorinated polyvinyl chloride pipe (Chlorinated Polyvinyl chloride ), thickness 3.2millimetreconforming to IS 15778 (CTS Series) with necessary Chlorinated Polyvinyl chloridefittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV. (All Floors) |
| 200 | Supplying and erecting 32/40millimetre(ID/OD) Chlorinated polyvinyl chloride pipe (Chlorinated Polyvinyl chloride ), thickness 3.8 millimetreconforming to IS 15778 (CTS Series) with necessary Chlorinated Polyvinyl chloridefittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV. (All Floors) |
| 201 | Supplying and erecting 40/50millimetre(ID/OD) Chlorinated polyvinyl chloride pipe (Chlorinated Polyvinyl chloride ), thickness 3.8millimetreconforming to IS 15778 (CTS Series) with necessary Chlorinated Polyvinyl chloridefittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(All Floors) |
| 202 | Providing and fixing on walls /ceiling/ floor 40 millimetrediameteru Poly vinyl chloridepipe with necessaryfittings,remaking good the demolished portion etc.complete.Including removing existingpipe line if necessary and conveying and stacking the samein MSIDCchowky or as directedetc. complete. (All Floors) |
| 203 | Providing and laying cast iron pipes of B class of 150 millimetrediameter with sockets and spiget ends/ flanges and cast centrifugally/ vertically including specials, laying pipes and back filling the trench complete including excavation. (All Floors) |
| 204 | Providing and making flanged connection for the 150 millimetrediameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete. (All Floors) |
| 205 | Providing and fixing 75millimetredia stabiliser pipe/Poly vinyl chloridesoil vent/waste pipeandwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete. (All Floors) |
| 206 | Providing and fixing 100millimetredia stabiliser pipe/Poly vinyl chloridesoil vent/waste pipeandwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete. (All Floors) |
| 207 | Providing and fixingPoly vinyl chlorideRain water pipes of 160 millimetreouter diameter and having wall thickness of 2.2 to 2.7millimetreconfirming to I.S. 13592-1992 including proper rainwater receiving recess withPoly vinyl chlorideplug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25 millimetreto 40 millimetrefrom face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All thePoly vinyl chloridefittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. Complete. (All Floors) |
| 208 | Providing and fixingPoly vinyl chlorideRain water pipes of 110 millimetreouter diameter and having wall thickness of 2.2 to 2.7millimetreconfirming to I.S. 13592-1992 including proper rainwater receiving recess withPoly vinyl chlorideplug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25 millimetreto 40 millimetrefrom face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All thePoly vinyl chloridefittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. Complete. (All Floors) |
| 209 | Providing and fixing in position U Poly vinyl chlorideultra violet stabilized 110millimetreouter diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. (All Floors) |
| 210 | Providing and fixing 15 centimetrex 10 centimetresalt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. (All Floors) |
| 211 | Providing and laying concrete pipes of I.S.NP. class of 150 millimetrediameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 212 | Providing and laying concrete pipes of I.S.NP. class of 225 millimetrediameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 213 | Providing and laying concrete pipes of I.S.NP. class of 300 millimetrediameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 214 | Providing and constructing Brick Masonry Inspection Chamber 60 centimetrex 45 centimetrex 90 centimetreincluding 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete withReinforced cement concreteCover medium duty 140 Kilogram with frame etc complete. (All Floors) |
| 215 | Providing and constructing Brick Masonry inspection trap Chamber 90 centimetrex 45 centimetreincluding 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete withReinforced cement concreteCover medium duty 140 Kilogram. etc complete. (All Floors) |
| 216 | Providing and constructing Brick Masonry Inspection Chamber 90 centimetrex 45 centimetreWithReinforced cement concreteraft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight with 75millimetrethickReinforced cement concretecover medium duty 140Kilogram etc. Complete. (All Floors) |
| 217 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450 millimetrediameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 218 | Providing and constructing Ductile Iron circular manhole 45centimetre diameterAt top 90centimetreat bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15centimetrethick burnt brick mansonry with 1:1 cement mortar plaster 25millimetrethick inside and outside 20millimetre(1:3) ductile iron heavy type cover with ring 125Kilogramin weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. |
| 219 | Cast Iron Steps for Manhole (All Floors) |
| 220 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the cement concrete/rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.(All Floors) (All Floors) |
| 221 | Providing and fixing 8centimetrerigidPoly vinyl chlorideNahani trap includingPoly vinyl chloridegrating ,bend, connecting piece of U Poly vinyl chloridepipe up to the outside face of wall ,making the good damaged surfaceandtestingetc.complete. (All Floors) |
| 222 | Providing and fixing 15centimetrerigidPoly vinyl chlorideNahani trap includingPoly vinyl chloridegrating ,bend, connecting piece of U Poly vinyl chloridepipe up to the outside face of wall ,making the good damaged surfaceandtestingetc.complete(All Floors) |
| 223 | Providing and fixing 10centimetre Poly vinyl chloridenahani trap with grating etc. complete. (All Floors) |
| 224 | Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in Reinforced cement concreteTank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testingetc. 50 millimetrepipe. (All Floors) |
| 225 | Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in Reinforced cement concreteTank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testingetc. 80 millimetrepipe. (All Floors) |
| 226 | Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in Reinforced cement concreteTank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testingetc.150 millimetrepipe. (All Floors) |
| 227 | Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in Reinforced cement concreteTank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testingetc. 200 millimetrepipe. (All Floors) |
| 228 | FURNITURE ITEMS |
| 229 | EXECUTIVE TABLE ARISTO TBL1800 LH RU 1200 PDL:Or Equivalent brands like Blowplast / Featherlite/ WiproPrimary Work Surface Made of 25 millimetrethick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 millimetre Poly vinyl chloridemembrane pressed on to top Soft closing access flap with in-build power box are provided on work surface for wire management Secondary Work Surface Made of 25 millimetrethick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 millimetre Poly vinyl chloridemembrane pressed on to top.Modesty Panel Made of 25 millimetrethick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 millimetre Poly vinyl chloridemembrane pressed on to top.Under structure Made of 25 millimetreThick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping.Integrated Pedestal Made of 25 millimetreThick Pre-laminated twin board of E1-P2 grade and approved shadeconfirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping.Drawer fronts made of 25 millimetrethick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 millimetre Poly vinyl chloridemembrane pressed on to top Pedestal construction is BOX-BOX-FILE type which Uses powder coated 400millimetrelong metalPanel Drawer Slides. Drawer extension is 325millimetre .Drawers have a soft closing & anti slam mechanism.Handles are provided for ease of opening.Pedestals are provided with lock for security.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 230 | EXECUTIVE TABLE BCKUNTARISTO BCKUNT 1800W 750H: Or Equivalent brands like Blowplast / Featherlite/ WiproTop Panel-Made of 25 millimetrethick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 millimetre Poly vinyl chloridemembrane pressed on to top.Slide Door Unit-Made of 25 millimetreThick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping for body panels like side, bottom,back and shelves.Shutters are made of 25 millimetrethick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4 millimetre Poly vinyl chloridemembrane pressed on to top. Shutters have a soft closing & anti slam mechanism. Handles are provided for ease of opening.Storage is provided with lock for security.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 231 | HIGH BACK CHAIRQuartz Leatherette-High Back: Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT/BACK ASSEMBLY: the seat assembley is made up of 15 millimetrethick moulded plywood layered with assembly of PU form of 45 kg/m3 density and slab stock foam of 28kg/m3 density and whole sub-assembly is then upholstered with leatherette cover.the back assembly is made up of 12 millimetrethick moulded plywood layered with P.U. foam of 45kg/m3 density and U-foam of 28kg/m3 density. A 200GSM recron sheet is placed over the P.U foam and whole sub assembly is upholstered with leatherette Cover TILT MECHANISM, SPINES & SPINE CONNECTOR: The mechanisam is designed with the following feature360 degree , 3 Positing locking , Tilt tension adjustment.ARMRESTS: The armrest is made of die-cast aluminimum with buffing finishPNEUMATIC HEIGHT ADJUSTMENT: The pnenumatic height adjustment has a storke of 10.0+-0.3 centimetre .PEDESTAL ASSEMBLY: The pedestal is made of high pressure die cast polished aluminium with a buffed outside surface and black colour coated internal surface. it is fitted with 5 castor and has a pitch center diameter of 67.5+_0.5centimetre TWIN WHEEL CASTORS :5 One Number . twincastors are injection moulded in black polyamide.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 232 | FULL BACK CHAIRQuartz Leatherette-Full Back: Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT/BACK ASSEMBLY: the seat assembley is made up of 15 millimetrethick moulded plywood layered with assembly of PU form of 45 kg/m3 density and slab stock foam of 28kg/m3 density and whole sub-assembly is then upholstered with leatherette cover.the back assembly is made up of 12 millimetrethick moulded plywood layered with P.U. foam of 45kg/m3 density and U-foam of 28kg/m3 density. A 200GSM recron sheet is placed over the P.U foam and whole sub assembly is upholstered with leatherette CoverTILT MECHANISM, SPINES & SPINE CONNECTOR: The mechanisam is designed with the following feature360 degree , 3 Positing locking , Tilt tension adjustment.ARMRESTS: The armrest is made of die-cast aluminimum with buffing finishPNEUMATIC HEIGHT ADJUSTMENT: The pnenumatic height adjustment has a storke of 10.0+-0.3 centimetre .PEDESTAL ASSEMBLY: The pedestal is made of high pressure die cast polished aluminium with a buffed outside surface and black colour coated internal surface. it is fitted with 5 castor and has a pitch center diameter of 67.5+_0.5centimetre TWIN WHEEL CASTORS :5 One Number . twincastors are injection moulded in black polyamide.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 233 | 3 SEATER SOFA Pisa 3 Str :Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT FOAM : The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette.BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette.UNDERSTRUCTRE : Understructure is made up of 1.2±0.1centimetre . thick hot pressed plywood [moisture resistance & termite proof as per IS:303] & pinewood of cross sections devoid of major knots & surface defects. 6 One Number . per seat & 3.8 millimetreDia zigzag spring assembly is mounted over understructure for cushioning purpose.LEG ASSEMBLY : It is a welded Assembly made in Stainless steel (grade SS 202) tube & plate with plastic endcap.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 234 | CENTER TABLECenter Table Or Equivalent brands like Blowplast / Featherlite/ Wipro: Black tinted Toughened glass UV glued with bushes made in SS 202 grade for focing with understructure.2)PISA SIDE & CENTER TABLE UNDERSTRUCTURE: It is a welded Assembly made in SS202 grade diameter12±0.04 as per IS:1762.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 235 | WOODEN STORAGE UNITECHO - ALL WOOD STORAGE UNIT 900X740X450 Or Equivalent brands like Blowplast / Featherlite/ WiproWooden storage range comprises of a range of Low height to medium height wooden HDUBody : Body is made from 18 millimetrePLB with all the edges sealed with 0.8millimetrethickPoly vinyl chlorideEdgeband. The Back panel is 9 millimetreWhite PLT. The entire construction is ready to assemble unit and is assembled with suitable KD fittings.The shelves and separator panels ( if available ) is made from 18millimetrewhite PLT and edges are sealed with 0.8millimetreedge band. The bottom shelf is fixed and other shelves have one step adjustment for optimizing the space.Doors : Door Panels ae made from 18millimetrePLB with 2millimetreEdge band on all edges ad a flush Plastic handle is fitted vertically at the center of the door. The hinge door has suitable hinges and HDU is fitted with an adjustable fitting forheight adjustment.HDU has a three point lock All the storages are fitted with a 6millimetreleveler at bottom for levelling.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 236 | MIDDLE MAIN DESK WITH ERUTrident Middle Main Deskwith ERU (LHS) Or Equivalent brands like Blowplast / Featherlite/ Wipro. size : 1650 Width x 700 Depthx 743 Height(Main Desk) 1000 Width X 450 DepthX 743 Height (ERU).Top shall be of 18millimetrethickness made of PLT board with 2millimetreEdge banding. Wenge and savannah Maple PLT board shall be used. The Understructure shall be in pre-laminated panels made with PLT boards . 2- Drawerand 3 - Drawer storage units with different combinations to support tops made with 18millimetrePLT boards of different colours.Modesty and back panels made with 18millimetrePLT boards. The pedestals / storages shall be fitted with necessary locks.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 237 | HIGH BACK CHAIR Marvel-High Back: Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT ASSEMBLY : The Cushioned seat should be made of Injection molded Plastic outer & inner. Plastic Inner should be upholstered with leatherette and moulded High Resilience (HR) Polyurethane foam of Density 45±2 kg/m3,and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression.*Seat SIZE : 47.0centimetre . (W) x 48.0centimetre . (D)BACK ASSEMBLY: The Cushioned back should be made of PU Foam with insitu molded MS E.R.W Round Tube of size 1.9±0.03 centimetrex 0.16 ±0.0128 centimetre . It upholstered with Leatherette.HIGH BACK SIZE: 47.7centimetre . (W) x 76.4centimetre ARMRESTS: The armrest top should be moulded from polyurethane(PU) and mounted on to a drop lift adjustable type tubular armrest support made of 03.81±0.03centimetrex 0.2±0.01centimetrethk M.S. E.R.W tube having chrome plated finish.The armrest height adjustable up to 6.5±0.5 centimetrein 5 steps.ACTIVE BIO-SYNCHRO MECHANISM : The adjustable tilting mechanism should be designed with the following features:• 360\" revolving type. • Front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort. • Tilt tension adjustment can be operated in seating position. • 5-position Tilt limiter giving option of variable tilt angle to the chair. • Seat/back tilting ratio of 1: 2 • The mechanism housing should be made up of HPDC Aluminium black powder coated.SEAT DEPTH ADJUSTMENT : Seat depth adjustment should be integrated in the seat through a sliding mechanism. Seat depth adjustment range should be of 6.0±0.5centimetre .ADJUSTABLE BACK SUPPORT: Back Frame should be connected to the Up/Dn mechanism housed in Plastic T spine.It can be adjusted in the range of 7.42±0.5centimetrefor the comfortable back support to suit individual need. PNEUMATIC HT. ADJUSTMENT: The pneumatic ht adjustment has an adjustment stroke of 10.0±0.3centimetre .PEDESTAL ASSEMBLY: The pedestal should be High Pressure Die cast polished Aluminium and fitted with 5 One Number . twin wheel castors. The pedestal should be 65.0 ± 0.5 centimetre . pitch-centerdiameter (75.0 ± 1.0 centimetre . With castors.)TWIN WHEEL CASTORS:The twin wheel castors should beinjection moulded in black PP having 6.0± 0.1 centimetrewheel Diameter.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 238 | MID BACK CHAIRMarvel-Mid back : Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT ASSEMBLY : The Cushioned seat should be made of Injection molded Plastic outer & inner. Plastic Inner should be upholstered with leatherette and moulded High Resilience (HR) Polyurethane foam of Density 45±2 kg/m3,and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression.*Seat SIZE : 47.0centimetre . (W) x 48.0centimetre . (D)Marvel-Mid back : BACK ASSEMBLY: The Cushioned back should be made of PU Foam with insitu molded MS E.R.W Round Tube of size 1.9±0.03 centimetrex 0.16 ±0.0128 centimetre . It upholstered with Leatherette.HIGH BACK SIZE: 47.7centimetre . (W) x 76.4centimetre ARMRESTS: The armrest top should be moulded from polyurethane(PU) and mounted on to a drop lift adjustable type tubular armrest support made of 03.81±0.03centimetrex 0.2±0.01centimetrethk M.S. E.R.W tube having chrome plated finish.The armrest height adjustable up to 6.5±0.5 centimetrein 5 steps.ACTIVE BIO-SYNCHRO MECHANISM : The adjustable tilting mechanism should be designed with the following features:• 360\" revolving type. • Front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort. • Tilt tension adjustment can be operated in seating position. • 5-position Tilt limiter giving option of variable tilt angle to the chair. • Seat/back tilting ratio of 1: 2 • The mechanism housing should be made up of HPDC Aluminium black powder coated.SEAT DEPTH ADJUSTMENT : Seat depth adjustment should be integrated in the seat through a sliding mechanism. Seat depth adjustment range should be of 6.0±0.5centimetre .ADJUSTABLE BACK SUPPORT: Back Frame should be connected to the Up/Dn mechanism housed in Plastic T spine. It can be adjusted in the range of 7.42±0.5centimetrefor the comfortable back support to suit individual need PNEUMATIC HT. ADJUSTMENT: The pneumatic ht adjustment has an adjustment stroke of 10.0±0.3centimetre .PEDESTAL ASSEMBLY: The pedestal should be High Pressure Die cast polished Aluminium and fitted with 5 One Number . twin wheel castors. The pedestal should be 65.0 ± 0.5 centimetre . pitch-centerdiameter (75.0 ± 1.0 centimetre . With castors.)TWIN WHEEL CASTORS:The twin wheel castors should beinjection moulded in black PP having 6.0± 0.1 centimetrewheel Diameter.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 239 | VISITOR CHAIRMARVEL- Or Equivalent brands like Blowplast / Featherlite/ Wipro Visitor 1) SEAT ASSEMBLY : The Cushioned seat should be made of Injection molded Plastic outer & inner. Plastic Inner should be upholstered with leatherette and moulded High Resilience (HR) Polyurethane foam of Density 45±2 kg/m3,and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression.*Seat SIZE : 47.0centimetre . (W) x 48.0centimetre . (D)2) BACK ASSEMBLY: The Cushioned back should be made of PU Foam with insitu molded MS E.R.W Round Tube of size 1.9±0.03 centimetrex 0.16 ±0.0128 centimetre . It upholstered with Leatherette.BACK SIZE: 47.7centimetre . (W) x 60.1centimetre . (D)Visitor TUBULAR FRAME: The tubular frame should becantilever type and made of Ø2.54± 0.03centimetreX 0.02 ± 0.016 centimetrethick SS 202 tube. The back should beconnected to frame through chrome plated high pressure die case connector pieceNote: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 240 | T 20 GGYL 1200 millimetre600 millimetre750 millimetreOr Equivalent brands like Blowplast / Featherlite/ WiproWorktop-Made of 25 millimetreThick Pre-laminated board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping.Access Flap provided on work surface for wire management.Modesty Panel-Made of 18 millimetreThick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping.Legs-Cube legs are fabricated from MS ERW Tube of 50millimetrex 25millimetrex 1.2 millimetrethick and 40millimetrex 40millimetrex 1.2millimetrethick (as per IS: 7138). At the top surface of leg, support brackets of 3millimetrethick HR (as per IS: 2062) are welded for fixing worktop. These arewelded together by argo shield welding. This welded structure is coated with 50 micron epoxy polyester coating. At the base, a plastic cap with M8 molded insert isfixed, on to which a straight M8 leveler fitted which allows for adjustment of the heightupto 50 millimetre .Cross Members-Cross Members in Unitised T-2 Desk Series are made from 50 millimetreX 25 millimetreX 1.2 millimetrethick ERW tube (as per IS:7138). These are coated with 50 micron epoxy polyester coating.Cross Members are assembled by friction fit PDC joinery and grub screws. There are always two cross members for one table.Access Flap-Soft closing access flap is used in Unitized T-2 Desk Series. Provision for standard size of 8 module electrical (Anchor Roma) is offered. Access flap is made from Aluminum extrusion, PDC parts made from Aluminum Alloy and plastic parts are made from Nylon 6 and wire brush with nylon bristles.Power Box-Power box made with 0.8millimetrethick CRCA (IS: 513), with switch plate (8 Module cutout provision for Anchor Roma). This is fixed with worktop along the depth at Access Flap position. Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 241 | T 20 GGYL 1800 millimetre750 millimetre750 millimetreOr Equivalent brands like Blowplast / Featherlite/ WiproWorktop-Made of 25 millimetreThick Pre-laminated board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping.Access Flap provided on work surface for wire management.Modesty Panel-Made of 18 millimetreThick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2millimetrethickPoly vinyl chloridelipping.Legs-Cube legs are fabricated from MS ERW Tube of 50millimetrex 25millimetrex 1.2 millimetrethick and 40millimetrex 40millimetrex 1.2millimetrethick (as per IS: 7138). At the top surface of leg, support brackets of 3millimetrethick HR (as per IS: 2062) are welded for fixing worktop. These arewelded together by argo shield welding. This welded structure is coated with 50 micron epoxy polyester coating. At the base, a plastic cap with M8 molded insert is fixed, on to which a straight M8 leveler fitted which allows for adjustment of the height upto 50 millimetre . Cross Members-Cross Members in Unitised T-2 Desk Series are made from 50 millimetreX 25 millimetreX 1.2 millimetrethick ERW tube (as per IS:7138). These are coated with 50 micron epoxy polyester coating. Cross Members are assembled by friction fit PDC joinery and grub screws. There are always two cross members forone table. Access Flap-Soft closing access flap is used in Unitized T-2 Desk Series. Provision for standard size of 8 module electrical (Anchor Roma) is offered. Access flap is made from Aluminum extrusion, PDC parts made from Aluminum Alloy and plastic parts are made from Nylon 6 and wire brush with nylon bristles.Power Box-Power box made with 0.8millimetrethick CRCA (IS: 513), with switch plate (8 Module cutout provision for Anchor Roma). This is fixed with worktop along the depth at Access Flap positionNote: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 242 | Wooden Pedestal-UNIT WDN PED 3 BBF 400millimetre450millimetre /400W X 450D X 640H: Or Equivalent brands like Blowplast / Featherlite/ WiproAll Panels :- 18 millimetrePLB board BBF & FF PEDESTAL :-Leveller base height 18 millimetreheight with levelling adjustment max 10 millimetre Side, Bottom Panel :- 0.8 millimetre Poly vinyl chlorideEdgebandBack Panel :- No Edgeband 0.8 millimetre Poly vinyl chlorideEdgeband for BF PedestalTop Panel :- 2millimetre Poly vinyl chlorideEdgeband 0.8 millimetre Poly vinyl chlorideEdgeband for BF PedestalFascia :- 18 millimetrePLB with 2 millimetreEdgebandBack Panel :- 18 millimetrePLB with 0.8 millimetreEdgebandBottom Panel :- 6 millimetrePLB MDF - No EdgebandHandle :- MS Powder coated handleSlide :- Powder coated Single extension full panel drawer Slides with rollersFile Drawer :- File drawer provided with fifth roller arrangmentBBF Pedestal :- Cam Lock & Central RH locking with actuator lever & locking strip mechanism for Box - Box - FileNote: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 243 | Motion High Back Larger Seat - Adjustable Armrests Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT/BACK ASSEMBLY: The cushioned seat assembly consists of seat base moulded in glass-filled Poly-amide, moulded Polyurethane foam & upholstered with high stretch knitted polyester fabric. The cushioned back assembly consists of back inner moulded in Polypropylene in-situ moulded with Polyurethane foam & upholstered with high stretch knitted polyester fabric. Back Size : 45.5centimetre . (/1/) x 53.0centimetre . (H)Seat Size : 48.5centimetre . (W) x 47.0centimetre . (D) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam used in seat and backcushion is moulded in Density Min 48 kg/m3, and hardness load 15 ± 2 kgf as per IS:7888 for 25% compression. TILT MECHANISM, SPINES & SPINE CONNECTOR: The seat and back are firmly connected to the base frame and are cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need for complex manual adjustments. The cantilevered seat offers impact cushioning while sitting and synchronises with the back movement during posture changes. The \"\"S\"\" shaped spines moulded in high strength glass-filled Poly-amide and the spine connector moulded in glass-filled Poly-amide form the back-spine structure involved in multi-dimensional recline motion. The variable tilt angle recline motion can be adjusted with 3 position Tilt Limit featurewhich should be inbuilt in seat base and the tension (return force) should be user weight dependent. ADJUSTABLE ARMRESTS: The assembly consists of armrest housing sliding over the armrest structure, both moulded in glass-filled Poly-amide: The height adjustment feature should be button operated having adjustment of 6.6±0.5 centimetre . The Armrest Top should be made up of integral skin PU moulded over plastic inner moulded in glass-filled Poly-amide. PNEUMATIC HEIGHT ADJUSTMENT: The seating height can be adjusted with a pneumatic gas-lift having an adjustment stroke of 9.2 ± 0.3centimetrePEDESTAL ASSEMBLY: The pedestal should be injection moulded in glass-filled Poly-amide and fitted with 5 One Number . twin wheel castors. The pedestal should be 66.0±0.5centimetre . pitch centre diameter and 76.0±1.0centimetre . with castors TWIN WHEEL CASTORS :5 One Number . twin wheel castos are injection moulded in Poly-amide having 5.0 ± 0.1centimetrewheel diamter assembled to the pedestal.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 244 | Relax Quarter desklet Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT / BACK ASSEMBLY : The Seat is injection moulded in glass filled Polypropylenecompound which is upholstered with fabric upholstery covers and moulded Polyurethane foam.The Back is injection moulded in glass filled Polypropylene compound which is upholstered withMesh fabric (Refer colour chart for seat & Back upholestry in product catalog). * SEAT SIZE : 50.0 centimetre . (W) x 48.0centimetre . (D) * BACK SIZE : 53.0centimetre . (W) x 39.0 centimetre . (H) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam ismoulded with density 45±2 kg/m³ and hardness 16±2 kgf as per IS:7888 for 25% compression. M.S. POWDER COATED FRAMES FOR 4 LEG CHAIRS :The powder coated ( DFT50±10 microns) welded tubular main frame is made from Ø 2.54 ± 0.03centimetrex 0.2 ± 0.016centimetreandØ1.6±0.3 millimetrex 0.16 ± 0.0128 centimetreM.S. E.R.W tube. The Ø1.9 ±0.3 millimetrex 0.12 ±0.0096centimetre M.S.E.R.W. tube used as connecting member between LH & RH frames.Desklet support frame is made from Ø 2.22 ± 0.03centimetrex 0.16 ± 0.0128centimetreand welded to mainframe M.S. POWDER COATED FRAMES FOR SLED BASE CHAIRS :The powder coated( DFT 50±10 microns) welded tubular main frame is made from Ø 2.54 ± 0.03centimetrex 0.2 ± 0.016 centimetreand Ø1.9 ±0.3 millimetrex 0.12 ±0.0096centimetreM.S.E.R.W. tube.SHOE : The shoes are made of glass filled Polypropylene compound with and pressed fitted with tubular frame. Felt is provided below the shoes .ARMREST : The Armrest are made of glass filled Polypropylene compound andassembled over the tubular frame.QUARTER DESKLET: The \"L\" shape desklet is made of 1.8 ±0.05 centimetre . thk. pre-laminatedparticleboard with 0.2 ± 0.05 centimetre . thk. injection moulded PolyPropylene all around. Desklet hasFront and back adjustment of 8.0centimetre± 0.5centimetre OUTER DIMENSION: 31.5±0.1 centimetre . (W) X 47.0±0.1 centimetre . (D)TWIN WHEEL CASTORS: The twin wheel castors are injection moulded in Black Poly Amide.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 245 | Gain Pro Locker-PLU MAIN 4 DR CAM LOCK-1950 H x 375 W x 470 D: Or Equivalent brands like Blowplast / Featherlite/ WiproOverall size of 4 Door PLU - Lkr (Base) shall be 380 millimetre (W)x450 millimetre (D)x1830 millimetre (H).DMX Drg.- PL 13-A4-33797,R1 - 4 Sheets(Cam Lock) DMX Drg.- PL-13-A4-36467,R1-4 Sheets(Hasp.) Stackability shall have add- on units that can be stacked width wise to form bank of lockers having co millimetre on side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6millimetrethickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABSplastic handle . Ventilation shall be attractive punched pattern for ventilation . Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 246 | OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H)-Optz Plus TD3 Solid back panel: Or Equivalent brands like Blowplast / Featherlite/ WiproOverall Dimensions of TD3 Twin Drive Unit 3 bay(U/C + Fittings + Cover) shall be 3600 millimetre (W)x800 millimetre (D)x2047 millimetre (H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4) .Finish shall be Epoxy polyester powder coated thickness of 40 microns . Shelf construction shall be made from CRCA steel 0.8millimetrethick IS :513 .Uniformly distributed load capacity of 100 Kg . Undercarriage shall have construction in welded frame made of HR sheet 3millimetrethick conforming to IS : 3062. The Movements shall be Drive Type configuration : In case of D2,D3 & D4 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving ,3 antifriction ball bearing for rolling. The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the Uchannel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection-molding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is of Godrej make & placed at suitable height .The ‘sprocket-chain’ arrangement is covered by a 1millimetrethk. CRCA sheet Drive Unit Cover with dimensions 1302 millimetrex 398 millimetrex 87 millimetreand is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99.0millimetre . Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; and with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized / blackodized / Zn Plated.Also total no. of loading levels per understructure shall be 36 for TD3. Label holder - It is an aluminium extrusion of length 396 millimetrefor LD/SD and 796 millimetrefor TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394 millimetrefor LD/SD and 794 millimetrefor TD.Over that a transparent plastic of corresponding length of 150-300 micron polythene is to be inserted.TD units are designed with tie rod assembly options as well. it acts as a substitute to the back panels (only in twin body) if the customer chooses to not have back panels. The assembly consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles. The tie rods are fixed in a shape of ‘X’ between two opposite shelves. The tie rods are made of 4 millimetrediameter rods of MS while the fixing brackets are made of 2 millimetrethk. CRCA Steel conforming to IS: 513 Gr.D. This assembly is available for both heights – 1980H and 2361H. Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 247 | Optz Plus SD3: Or Equivalent brands like Blowplast / Featherlite/ WiproOverall Dimensions of SD 3 Single Drive Cover Unit 3 Bay(U/C + Fittings + Cover) shall be 3600 millimetre (W)x400 millimetre (D)x2047 millimetre (H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4) .Finish shall be Epoxy polyester powder coated thickness of 40 microns . Shelf construction shall be made from CRCA steel 0.8millimetrethick IS :513 .Uniformly distributed load capacity of 100 Kg . Undercarriage shall have construction in welded frame made of HR sheet 3millimetrethick conforming to IS : 2062. The Movements shall be Drive Type configuration : In case of D2,D3 & D4 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving ,3 antifriction ball bearing for rolling.LD understructure has 2 One Number . of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the Uchannel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection-molding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together.(All Floors) .The ‘sprocket-chain’ arrangement is covered by a 1millimetrethk. CRCA sheet Drive Unit Cover with dimensions 1202 millimetrex 398 millimetrex 87 millimetreand is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99.0millimetre . Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; and with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized / blackodized / Zn Plated.Also total no. of loading levels per understructure shall be 18 for SD3. Label holder - It is an aluminium extrusion of length 396 millimetrefor LD/SD and 796 millimetrefor TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394 millimetrefor LD/SD and 794 millimetrefor TD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 248 | Optz Plus LD3: Or Equivalent brands like Blowplast / Featherlite/ WiproOverall Dimensions of LD3 Single last Drive Unit 3 Bay(U/C + Fittings + Cover) shall be 3600 millimetre (W)x400 millimetre (D)x2047 millimetre (H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4) .Finish shall be Epoxy polyester powder coated thickness of 40 microns . Shelf construction shall be made from CRCA steel 0.8millimetrethick IS :513 .Uniformly distributed load capacity of 100 Kg . Undercarriage shall have construction in welded frame made of HR sheet 3millimetrethick conforming to IS : 2062. The Movements shall be Drive Type configuration : In case of D2,D3 & D4 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving , 3 antifriction ball bearing for rolling. LD understructure has 2 One Number . of anti-tilt bearing assembly. The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the Uchannel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection-molding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together.The Recess handle lock is of Godrej make & placed at suitable height .The ‘sprocket-chain’ arrangement is covered by a 1millimetrethk. CRCA sheet Drive Unit Cover with dimensions 1202 millimetrex 398 millimetrex 87 millimetreand is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99.0millimetre . Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; and with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized / blackodized / Zn Plated.Also total no. of loading levels per understructure shall be 18 for LD3. Label holder - It is an aluminium extrusion of length 396 millimetrefor LD/SD and 796 millimetrefor TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394 millimetrefor LD/SD and 794 millimetrefor TD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 249 | Optz Plus D3 CHNL 800 millimetre : Or Equivalent brands like Blowplast / Featherlite/ WiproIt consists of ‘C’ section 2millimetrethk HR sheet & Square 25.4 millimetreX 2 millimetrethk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug & screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800 millimetre , 1600 millimetreand 2400 millimetre .Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 250 | Optz Plus D3 CHNL 1600 millimetre :Or Equivalent brands like Blowplast / Featherlite/ WiproIt consists of ‘C’ section 2millimetrethk HR sheet & Square 25.4 millimetreX 2 millimetrethk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug & screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800 millimetre , 1600 millimetreand 2400 millimetre .Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 251 | Optz Plus D3 CHNL 2400 millimetre :Or Equivalent brands like Blowplast / Featherlite/ WiproIt consists of ‘C’ section 2millimetrethk HR sheet & Square 25.4 millimetreX 2 millimetrethk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug & screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800 millimetre , 1600 millimetreand 2400 millimetre .Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 252 | Traverse 3 seater with 2: Or Equivalent brands like Blowplast / Featherlite/ Wipro3 seater with SS 304 arms at the endsMII 100%Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. (All Floors) |
| 253 | Thrill Mesh Full Back:Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT/BACK ASSEMBLY: The seat is made up of 1.5 ±0.1 centimetre . thick hot-pressed plywood measuredand upholsteredwith fabric upholstery covers and moulded Polyurethane foam. The seat has extra thick foam on front edge to give comfort to popliteal area.The Back is injection moulded in glass filled Polypropylene which is upholstered with Mesh fabric.The back consist of adjustable lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 ±0.1centimetre . The chair seat & back size are SEAT SIZE 53.5centimetre . (W) x 51.0centimetre . (D)*MESH BACK SIZE51.0centimetre . (W) x 70.0centimetre . (H). HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45±2 kg/m³ and hardness 14±2 kgf as per IS:7888 for 25%compression. ARMRESTS :The adjustable armrest is designed with the following features :· Up-Down adjustment– 6 steps (7.2 ± 0.5 centimetrerange)· Armrest top is mounted on Armrest structure made of glass filled Nylon· Fixed Armrest Top is PU moulded over Polypropylene insert.CENTER TILT SYNCHRO MECHANISM WITH MULTI LOCK : The mechanism is designed with the following features: 360° revolving type.· 3 position locking with anti shock mechanism.· Tilt tension adjustment.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 9.5 ± 0.3 centimetre .PEDESTAL ASSEMBLY : The pedestal is injection moulded in black glass-filled Nylon and fitted with 5 One Number . twin wheel castors. The pedestal is 66.1 ±0.5 centimetre . pitch-centerdiameter (76.1 ±1.0 centimetrewith castors). TWIN WHEEL CASTORS : The twin wheel castors are injection moulded in Black Nylon.WIDTH (W): 76.1centimetre .DEPTH (D): 76.1centimetre .HEIGHT (H): 101.5 - 111 .5 centimetre .SEAT HEIGHT (SH): 46.0 - 56.0centimetre Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 254 | PISA-2 Str: Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT FOAM : The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette.BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette.UNDERSTRUCTRE : Understructure is made up of 1.2±0.1centimetre . thick hot pressed plywood [moisture resistance & termite proof as per IS:303] & pinewood of cross sections devoid of major knots & surface defects. 6 One Number . per seat & 3.8 millimetreDia zigzag spring assembly is mounted over understructure for cushioning purpose.LEG ASSEMBLY : It is a welded Assembly made in Stainless steel (grade SS 202) tube & plate with plastic endcap.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands. |
| 255 | Time Out 4 Seater PU Coated:Or Equivalent brands like Blowplast / Featherlite/ WiproTime Out 4 Seater PU Coated size shall be1135 Widthmillimetre x 1175 Depthmillimetre x 750 Heightmillimetre . Top shall be 25millimetrethick base material shall be 25millimetreMDF board . On top PU painting of minimum 2H hardness with 75% glass as per color chart .Combination color graphics on the centre . Brown Laminate on bottom specially profiled edges for comfort . The Understructure shall be having bend pipe structure of MS powder coated . Pipe dia 38millimetre, 2millimetrethick and it shall be fitted with top by SS machine screws . Legs shall be of MS powder coated and 38millimetre diameterpipe legs are fixed with inderstructure and table top . Glide shall be of Plastic fixed at the understructure to prevent the damage of table top during stacking .Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 256 | Unwind Café Chair:Or Equivalent brands like Blowplast / Featherlite/ WiproThe Seat and Back should bemade up of injection moulded indoor grade PolyPropylene compound SEAT SIZE : 52.5centimetre . (W) x 53.2centimetre . (D) BACK SIZE : 51.6centimetre . (W) x 40.5centimetre . (H) The powder coated ( DFT 50±10 microns ) welded tubular frame should bemade from 0 2.22 ± 0.03centimetrex 0.16 ± 0.0128centimetreand 3.5 ± 0.03centimetrex 1.5 ± 0.03centimetrex 0.16 ± 0.0128centimetreMSERW tube. The shoes should bemade of indoor grade PolyPropylene compound and snap fitted with tubular frame. Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 257 | OXBO-Mid back: Or Equivalent brands like Blowplast / Featherlite/ WiproSEAT ASSEMBLY: The seat assembly should bemade up of 1.2 ±0.1 centimetre . thick hot-pressed plywood , upholstered with fabric upholstery covers and moulded Polyurethane foam.SEAT SIZE: 47.0centimetre . (W) x 48.0centimetre . (D)BACK ASSEMBLY: The back asembly. should bemade of powder coated (OFT 40-60 microns) tubular frame of 0 2.54 ±0.03 centimetre . x 0.2 ±0.016 centimetre .thk. MS ERW tube designed with contoured lumbar support for extra comfort. The back should beupholstered using double layer spacer mesh fabric with high tenacity yarn.BACK SIZE : 46.5centimetre(W) x 60.5centimetre(H)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should bemoulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgffor 25% compression.ARMRESTS: The one-piece armrests should beinjection moulded from black Co-polymer Polypropylene. CENTRE-TILT mechanism: The mechashould be m should bedesigned with the following features:• 360° revolving type.• 17° ±2° maximum tilt on pivot at centre • Upright position locking. Tilt tension adjustment..PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 11.0 ±0.3 centimetre .TELESCOPIC BELLOW ASSY: The bellow should be3 piece telescopic type and injection moulded in Black Polypropylene.PEDESTAL ASSEMBLY: The pedestal should beinjection moulded in black 33% glass-filled Nylon66 and fitted with 5 One Number . twin wheel castors. The pedestal should be66.3 ±0.5 centimetre . pitch-centerdiameter(76.3 ±1.0 centimetrewith castors.) TWIN WHEEL CASTORS: The twin wheel castors should beinjection moulded in black nylonNote: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 258 | Trident Junior 1 Main DeskOr Equivalent brands like Blowplast / Featherlite/ WiproSize shall be1200 Widthx 600 Depthx 743 Height.Top shall be of 18millimetrethickness made of PLT board with 2millimetreEdge banding. Wenge and savannah Maple PLT board shall be used. The Understructure shall be in pre-laminated panels made with PLT boards . 2- Drawerand 3 - Drawer storage units with different combinations to support tops made with 18millimetrePLT boards of different colours.Modesty and back panels made with 18millimetrePLT boards. The pedestals / storages shall be fitted with necessary locks.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 259 | CAFETERIA TABLE 4 LEGGED PU 1800X900-1800 x 900 x 750Polyurethane (PU) WORKTOP : Or Equivalent brands like Blowplast / Featherlite/ WiproWorktop is made of Medium density fibreboard, IS:12406 (MDF) 25 millimetrethk PU tops (E1 grade).On top side PU painting of minimum 2H pencil hardness with High gloss and matte on bottom side as per color chart. The Work tops are available in 3 shapes, viz.: Circle (DIA 800), Rectangle (1200x800), (1800x900), (2400x900) & Square (800x800), (900x900).UNDER-STRUCTURE POD TYPE : (HEIGHT - 740 / 1020) This under-structure consists of swaged coloum assembly, top mounting tube frame / plate & square/ rectangle base plate assembly. The swaged coloum is made of 1.2 millimetrethk CRCA (IS:513) & 5 millimetrethk HR steel plates (As per IS:2062) welded together using Argo shield welding. The top plate is 5 millimetrethk HR steel plates (As per IS:2062). The base plate assembly is made up of 3 millimetre& 5 millimetrethk HR steel plates (As per IS:2062), 8x8 millimetreSquare rod & DIA 30 millimetrerod (As per IS:432) welded together using Argo shield welding.The whole structure is EPOXY POLYSTER Powder Coated (DFT 40-60 microns). The product has knock down construction. It is assembled using alloy steel hardware & levellers at bottom.UNDER-STRUCTURE ROD TYPE : (HEIGHT - 740 / 1020) The rod type understructure is made of DIA 16 millimetre& 8 millimetreMS rod (As per IS:432) & 3 millimetrethk HR steel plates (As per IS:2062) welded together using Argo shield welding. The whole structure is EPOXY POLYSTER Powder Coated (DFT 40-60 microns). It is assembled using SS hardware & shoe at bottom.Trio legs is fabricated from combination of 1.2millimetre , 2millimetrethk CRCA (as per IS: 513), 3 millimetre , 5 millimetrethk HR (as per IS: 2062) which has a triangular shape. Argo Shield welding is used for fabrication.This is a three dimensional leg which has inclination in 2 planes, it has a ball socket M8 leveler with bottom translucent cap, that allows adjustment up to 50millimetreheight. The whole structure is EPOXY POLYSTER Powder Coated (DFT 40-60 microns). It is assembled using Alloy steel hardware (Ni / Zn plated).Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 260 | Polyurethane (PU) WORKTOP : Or Equivalent brands like Blowplast / Featherlite/ WiproWorktop is made of Medium density fibreboard, IS:12406 (MDF) 25 millimetrethk PU tops (E1 grade).On top side PU painting of minimum 2H pencil hardness with High gloss and matte on bottom side as per color chart. The Work tops are available in 3 shapes, viz.: Circle (DIA 800), Rectangle (1200x800), (1800x900), (2400x900) & Square (800x800), (900x900).UNDER-STRUCTURE POD TYPE : (HEIGHT - 740 / 1020).This under-structure consists of swaged coloum assembly, top mounting tube frame / plate & square/ rectangle base plate assembly. The swaged coloum is made of 1.2 millimetrethk CRCA (IS:513) & 5 millimetrethk HR steel plates (As per IS:2062) welded together using Argo shield welding. The top plate is 5 millimetrethk HR steel plates (As per IS:2062). The base plate assembly is made up of 3 millimetre& 5 millimetrethk HR steel plates (As per IS:2062), 8x8 millimetreSquare rod & DIA 30 millimetrerod (As per IS:432) welded together using Argo shield welding.The whole structure is EPOXY POLYSTER.Powder Coated (DFT 40-60 microns). The product has knock down construction. It is assembled using alloy steel hardware & levellers at bottom.UNDER-STRUCTURE ROD TYPE : (HEIGHT - 740 / 1020)The rod type understructure is made of DIA 16 millimetre& 8 millimetreMS rod (As per IS:432) & 3 millimetrethk HR steel plates (As per IS:2062) welded together using Argo shield welding.The whole structure is EPOXY POLYSTER Powder Coated (DFT 40-60 microns). It is assembled using SS hardware & shoe at bottom.Trio legs is fabricated from combination of 1.2millimetre , 2millimetrethk CRCA (as per IS: 513), 3 millimetre , 5 millimetrethk HR (as per IS: 2062) which has a triangular shape. Argo Shield welding is used for fabrication. This is a three dimensional leg which has inclination in 2 planes, it has a ball socket M8 leveler with bottom translucent cap, that allows adjustment up to 50millimetreheight. The whole structure is EPOXY POLYSTER Powder Coated (DFT 40-60 microns). It is assembled using Alloy steel hardware (Ni / Zn plated).Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 261 | Storwel Plain: Or Equivalent brands like Blowplast / Featherlite/ Wipro Storwel plain shall have an overall size of916 millimetre (W) x 486 millimetre (D) x 1981 millimetre (H) with welded construction. It should have the shelf thickness of 0.7millimetre , Back thickness of 0.8 millimetre , Door thickness of 0.8 millimetre(high yield strength) and all other components shall have a thickness of 0.9 millimetre . These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Plenty of colour options and shelving options shall be available.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 262 | Englishten Desk One Cubic Metrebench Or Equivalent brands like Blowplast / Featherlite/ Wipro: Enlighten is an ingenious product which provides an elegant,modular solution to the needs of modern day classroom. It offers flexibility in layout and efficiancy in space management Without compromising on seating comfort.A)Legs: Legs are made of MS ERW tube section (157138) of size 75x25x2millimetrethick oval tube with 5millimetrethk HR brackets as per IS:2062 and 2 millimetrethk CRCA brackets as per IS-513welded on to the tubes. Assembly is powder coated with epoxy polyester.Leg height varies from 705 to 1005 in pitch of 50 as per layout.Sturdy anchoring by anchor bolts on to base of 8 millimetrethk plate for proper resting of Leg**.Shoe made of ultramid -Nylon are provided at the bottom for covering the base plate.B)Side dads: Two side clads made of e18millimetrethk plate with 0.8 millimetrethkPoly vinyl chloridelipping and on the outside covered with welded metal structure made of 2millimetrethk CRCA as per 1S-513 powder coated with Epoxy polyester .C)Worktop: Worktop are made of 25millimetrethick Pre-Laminated Board of El-P2 Grade and approved shade conforming to IS:12823:1990. All the edge of work surface are provided with machine pressed 2 millimetrethickPoly vinyl chlorideedge band glued with hot melt glue.D)Seat: Seat has self closing mechanism which will operate by means of dead weight .Seat understructure is made from combination of welded fabricated structure of 5 millimetreThk HR as per IS:2062 and 8 millimetrethk ply as per 1S:303 with moulded PU foam of density 55 kg/cu.mtr. on top which in turn is covered with stitched upholstery made of leatherite as per INT/DSN/MSS/UPH1038 or foam back fabric as per TNT/DSN/MSS/UPH/013.Seat assembly is covered on bottom side by means of seat cover made of pp. E )Seat Back: Seat back is made from combination of 8 millimetrethk ply as per 15:303 with moulded foam on top which in turn is covered with stitched upholstery made leaterite as perINT/DSN/MSS/UPH/038 or foam back fabric as per INT/DSN/MSS/UPHJ013.F) Seat Support Frame : Seat support frame is made from combination of MS ERW tube section (IS 7138) of size 80x40x2.5millimetrethick rectangular tube and MS ERW tube section(IS 7138), of size 48x19.1x2millimetrethick oval tube welded together . Assembly os powder coated with Epoxy polyester.CAP made of ultramid are provided from front to cover the oval tubes.G)Modesty: Modesty is made of 25 millimetrethick pre-laminated twin board of E1-P2 Grade and approved shade conforming to IS:12823:1990. All the edge of modesty are provided with machine pressed 2millimetreThickPoly vinyl chlorideedge band glue with hot melt glue.Note: Architect/Engineer in-charge reserve the right to select the similar items from the any reputed brands.(All Floors) |
| 263 | Chemical Bolt M8 Packet of 20 |
| 264 | Electrical Work |
| 265 | HT PANELSupply, erection testing andcommissioningof Ten breaker panel board totally enclosed sheet steel clad floor mounting, vermin proof, fully interlocked horizontal isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having single / double isolation features complete with circuits as detailed below. The switchboard shall be complete with necessaryPoly vinyl chlorideinsulated copper busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11kv 3 phase, 50 cycle, earthed system with a rupturing capacity of 12 MVA at 11kv as per specification. |
| 266 | Two Incoming Breakers Panel each Equipped with2No.Air insulated metal clad housing.2set of 3 phasePoly vinyl chlorideinsulated copper busbars 630Amp. single pole cluster type Isolating contacts i.e. plug and switches.2No. Triple pole draw out truck mounted 2 MVA, 630 Amp, 11000 volts Vacuum Circuit Breaker.2No. Trip free motor spring charged closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical \"OFF\" & \"ON\" indicator.2No. 24 volt DC shunt trip coil. 1No. 24 volt DC closing coil.2 No. 230 volt AC Spring Charging Motor./Motor wound spring operated.6 Nos. Cast resin Current transformers of ratio 30A/5A, 15 VA burden Class 5P10 for protection.6Nos. Cast Resin Current transformers of ratio 30A/5A, 15 VA burden Class 1.0 for metering.6 Nos. Single Phase cast resin horizontal draw out line potential transformer ratio 11kV/110 volts, connected star/star with HV and LV connections, H.V. and L.V. fuses, Isolating plugs for H.V. and L.V. connection.1set of Strip heater to prevent absorption of moisture. |
| 267 | The Instrument and Relay Panel Fitted with: (For each incomer breakers Panel) 1No. Square Digital voltmeter of 96x96millimetresize of 0 to 15 KV range with 3 way and OFF selector switch.2No. Triple pole Microprocessor IDMT overcurrent & earth fault relay with two outer elements connected for overcurrent protection and the middle element for earth fault protection overcurrent setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N).2 No. circuit breaker control switch for electrical (T/N/C). 1No. Master trip relay (86)2No. Trip circuit supervision relay (95)2set of Red/Green indicating lamps for close and open position.2 No. Amber indicating lamp for auto trip.2 No. clear indicating lamp for trip circuit healthy.2set of white indicating lamps one per phase.2 No. blue indicating lamp for spring charged.1 No. clear indicating lamp for trip circuit healthy.1set of white indicating lamps one per phase.2 No. blue indicating lamp for spring charged.2 No. Push button on front door for emergency trip.2 hooter of 230volt with NO-NC contactor for 24 volt DC No. cable termination BOX to receive 11kV XLPE cable 3 core 185sqmillimetre .1 No. hooter.1set of ferrules, fuses, limit switch and wiring as required. |
| 268 | OUTGOINGS ( SIX NOS FOR TRANSFORMER + 2 SPARE)8No. Air insulated metal clad housing.8set of 3 phasePoly vinyl chlorideinsulated copper busbars 630 Amp rating.24 Nos. single pole cluster type Isolating contacts i.e. plug and switches.8No. Triple pole draw out truck mounted 12 MVA, 630 Amp, 11000volts Vacuum Circuit Breaker.8No. Trip free motor spring charged closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical \"OFF\" & \"ON\" indicator.8No. 24 volt DC shunt trip coil. 1No. 24 volt DC closing coil.8 No. 230 volt AC Spring Charging Motor/Motor wound spring operated mechanism24 Nos. Cast resin Current transformers of ratio 40-60A/5, 15VA burden Class 5P10 for protection & class 1.0 for metering. 1 Set of Strip heater to preventabsorption of moisture. The Instrument and Relay Panel Fitted with 1No.Square Digital A millimetre eter of 96millimetresize of 0-,30Amps,, range with 3 way and OFF selector switch. |
| 269 | 8 No Digital solid state multifunction meter for KV, Amp., KW, KVAr, KVA, KWH, KVAH, KVArh, P.F. Amp-h, HZ measurements.8 set of Red/Green indicating lamps for close and open position..8 No. Amber indicating lamp for auto trip.8 No. clear indicating lamp for trip circuit healthy.8 No. blue indicating lamp for spring charged.8 set of white indicating lamps one per phase.8 No. Push button on front door for emergency trip.8 No. Triple pole Microprocessor I.D.M.T. overcurrent and earth fault relay, with two outer elements connected for overcurrent and the middle element for earth fault protection overcurrent setting 50% - 200% Earth fault setting 20% -80% and with instantaneous element on all 3 pole settings 500-2000% on overcurrent and 200-3200% on earth fault (51, 51N, 50 and 50N)8 No. circuit breaker control switch for electrical (T/N/C).8 set of fuses, limit switches wiring etc. as required.8 No. Master trip relay (86).1No. Trip circuit supervision relay(95). 8 hooter of 230volt with NO-NC contactor for 24 volt DC1 No. cable termination box to receive 11kV XLPE cable 3 core 185 sqmillimetre .The switchboard shall be complete with earth bus, all interconnections, labels wiring, etc as required. |
| 270 | Supply of following capacity (continous loading) BEE 4 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq millimetreXLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. |
| 271 | The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c)Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-One Cubic Metre -sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; |
| 272 | h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o)Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. |
| 273 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 274 | Supplying and fixingPoly vinyl chloridesynthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652– 2006 having 2.5millimetrethicknessup to 11 kV |
| 275 | Providing pair of duly tested rubber hand gloves as per IS :47705suitable forworking up to 22 kV supply complete. |
| 276 | Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544duly tested, with necessary test certificate from manufacturer. |
| 277 | Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete. |
| 278 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 185 sq.millimetre . aluminium conductor laid in provided trench / pipe |
| 279 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq.millimetre . with necessary material as per specification |
| 280 | Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq.millimetre . with necessary material as per specification |
| 281 | Providing and erecting Heat shrinkable straight through joint kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x120 to 185 sq.millimetre . with necessary material as per specification |
| 282 | Supplying, erecting andcommissioningof diesel generating set with alternator of 2000 kVA input continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722- 2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a co millimetre on fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel day tank, exaust piping with support upto the terrace, control cabling etc. and obtaining necessary approval from Electrical inspector / MPCB as per specification. |
| 283 | Supply & installation of suitable Exhaust pipe, B class, 12\" MS ERW pipe (as per IS 3589) including all bends, etc. |
| 284 | Supply & installation of Insulation of Exhaust pipe with 24 gauge Al sheet with 100kg/m3 rockwool density , 50 millimetrethk for 8\" pipe. |
| 285 | Supply & Installation of insulation for silencer with 24 gauge Al sheet with 100kg/m3 rockwool density , 50 millimetre . |
| 286 | Supply & installation of S.S BELLOW 12\"\" with required mounting accessories. |
| 287 | Supply & installation of MS structure for exhaust pipe, silencer, Fuel tank, Fuel pipe,cable tray etc. (Painting with one coat of Primer and 2 coats of Enamel aluminium Paint is applicable only on MS structure). |
| 288 | Supply, installation, Testing andcommissioningof DG SYNCHRONIZING PANEL. All incomershall have SPD Class 1+2 with 100A 4P MCCB , RYB phase indicator lamp with MCB, on / off / trip indicator lamp, Digital voltmeter, Digital A millimetre eter, Digital MFM compatible for BMS control, CT for metering, CT for Sync Relay, control wiring, Under Voltage relay, Phase Sequence relay, Negative Phase protection Relay, reverse power relay, Over & under frequency relay, MP BASED GENERATOR CONTROL / SYNC RELAY, DC Voltmeter, DC A millimetre eter, AC power contractor, ON indicator lamp, Off indicator lamp, Push button, TNC switch, AM Switch, Digital Hooter, Annunciation window, Generator Master trip relay, Line voltage minitor, Battery changer.The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. I/C 3200A, 4P, 65kA, EDO, LSIG ACB - 4No6000A TPN 65kA CU BUSBAR. BUSBAR.O/G 3200A, 4P, 65kA, EDO, LSIG ACB - 4 NoAll outgoing shall have on / off / trip indicator lamp, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring.All incomer and outgoing shall be with automatic change over scheme, electrical & mechanical interlocking, auto/Manual on & off of DG Sets, breakers etc.Synchronizing Relay like Woodward/ Dief/ Deepsea/ PC centimetreor equivalent shall be provided for each DG set |
| 289 | Selection of Master DG Sets, operation(Opening/closing) of breakers as required and complete with interfacing with DG Set Controller 8 Channel temperature scanner for monitoring bearing and winding temperature, 16 window facia annunciator, Auto - manual selector switch for individual breaker & PLC. |
| 290 | Supply, installation, Testing andcommissioningof ISOLATER PANEL I/C- 3200A 4P MP, 50kA. ACB - 1 Nos , 3200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. |
| 291 | Supply, installation, Testing andcommissioningof ATS PANEL3200A 4P SOLENOID DRAW OUT TYPE ATS - 1 Nos , 3200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB. The Panel shall complying to latest IEC standards&It should be verified by OEM.. |
| 292 | Supply, installation, Testing andcommissioningof MAIN LT PANEL-1. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.MAIN LT PANEL-1I/C 3200A, 4P, 50kA, EDO, LSIG ACB - 3 No4000A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.BUSCOUPLER of3200A, 4P, 50kA, EDO, LSIG ACB - 2 No with on/off/trip indication lampO/G- 3200A, 4P, 50kA, EDO, LSIG ACB - 05 No1600A, 4P, 50kA, EDO, LSIG ACB - 03 No 1250A, 4P, 50kA, EDO, LSIG ACB - 03 No1000A, 4P, 50kA, EDO, LSIG ACB - 01 No800A, 4P, 50kA, EDO, LSIG ACB - 01 No 630A, 4P, 50kA,MP,MCCB - 01 No 200A, 4P, 50kA, MP- MCCB-01 No 100A, 4P, 50kA, MP, MCCB - 01 No |
| 293 | Supply, installation, Testing andcommissioningof MAIN LT PANEL-2. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.MAIN LT PANEL-2I/C 3200A, 4P, 50kA, EDO, LSIG ACB - 3 No4000A 50kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.BUSCOUPLER of3200A, 4P, 50kA, EDO, LSIG ACB - 2 No with on/off/trip indication lampO/G-3200A, 4P, 50kA, EDO, LSIG ACB - 05 No 2500A, 4P, 50kA, EDO, LSIG ACB - 01 No 1600A, 4P, 50kA, EDO, LSIG ACB - 01 No 1250A, 4P, 50kA, EDO, LSIG ACB - 04 No 800A, 4P, 50kA, EDO, LSIG ACB - 02 No 630A, 4P,50kA, TM, MCCB - 01 No 400A, 4P, 50kA, TM,MCCB - 01 No 200A, 4P, 50kA,TM, MCCB - 01 No 100A, 4P, 50kA,TM,MCCB- 01 No |
| 294 | Supply, installation, Testing andcommissioningof EMERGENCY PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.EMERGENCY PANEL- I/C- 2500A 4P MP, 50kA,ACB - 1 Nos & 1000A 4P MP, 50kA,ACB - 1 Nos with Electrical & Mechanical Interlocking 2500A 50kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.BUSCOUPLER of2500A, 4P, 50kA, EDO, LSIG ACB - 1 No with on/off/trip indication lampO/G- 630A FP MCCB 36kA TM BASED - 04 Nos400A FP MCCB 36kA TM BASED - 04 Nos200A FP MCCB 36kA TM BASED - 01 Nos100A FP MCCB 36kA TM BASED - 01 Nos |
| 295 | Supply, installation, Testing andcommissioningof LIFT PANEL-1&2. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.LIFT PANEL- 1 & 2 I/C- 400A 4P MP, 36kA. MCCB - 1 Nos 400A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 63A FP MCB 10kA - 15 Nos 100A FP MCCB 25kA - 01Nos |
| 296 | Supply, installation, Testing andcommissioningof STACK PARKING PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.STACK PARKING PANEL- I/C- 630A 4P MP, 36kA. MCCB - 1 Nos 630A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 400A FP 36kA TM BASEDMCCB - 13 Nos |
| 297 | Supply, installation, Testing andcommissioningof EV CHARGING PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.EV CHARGING PANEL- I/C-630A 4P MP, 36kA. MCCB - 1 Nos 630A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-100A FP MCCB 25kA - 11 Nos |
| 298 | Supply, installation, Testing andcommissioningof BASEMENT VENTILATION FAN DISTRIBUTION PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.BASEMENT VENTILATION FAN DISTRIBUTION PANEL- I/C- 630A 4P MP, 36kA. MCCB - 1 Nos630A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP 25kA TM BASEDMCCB-07 Nos |
| 299 | Supply, installation, Testing andcommissioningof700 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC |
| 300 | Supply, installation, Testing andcommissioningof BASEMENT FLOOR -L & PPANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.BASEMENT FLOOR -L & PPANEL- BLOCK-AI/C- 100A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 100A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 63A FP MCB 10KA- 10 Nos |
| 301 | Supply, installation, Testing andcommissioningof BASEMENT FLOOR -L & PPANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.BASEMENT FLOOR -L & PPANEL- BLOCK-BI/C- 100A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 100A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 63A FP MCB 10KA - 10 Nos |
| 302 | Supply, installation, Testing andcommissioningof GROUND FLOOR -L & PPANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.GROUND FLOOR -L & PPANEL- BLOCK-AI/C- 800A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 800A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 250A FP MCCB 16kA TMBASED - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 06 Nos |
| 303 | Supply, installation, Testing andcommissioningof GROUND FLOOR -L & PPANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.GROUND FLOOR -L & PPANEL- BLOCK-BI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 04 Nos 63A FP MCB 10KA - 08 Nos |
| 304 | Supply, installation, Testing andcommissioningof FIRST FLOOR -L & PPANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.FIRST FLOOR -L & PPANEL- BLOCK-AI/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-100A FP MCCB 25kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 05 Nos |
| 305 | Supply, installation, Testing andcommissioningof FIRST FLOOR -L & PPANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.FIRST FLOOR -L & PPANEL- BLOCK-BI/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 400A FP MCCB 25KA TM BASED MCCB - 02 Nos 100A FP MCCB 16kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 05 Nos |
| 306 | Supply, installation, Testing andcommissioningof SECOND FLOOR -L & PPANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.SECOND FLOOR -L & PPANEL- BLOCK-AI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED MCCB - 06 Nos 63A FP MCB 10KA - 04 Nos |
| 307 | Supply, installation, Testing andcommissioningof SECOND FLOOR -L & PPANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.SECOND FLOOR -L & PPANEL- BLOCK-BI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 06 Nos 63A FP MCB 10KA - 03 Nos |
| 308 | Supply, installation, Testing andcommissioningof THIRD FLOOR -L & PPANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.THIRD FLOOR -L & PPANEL- BLOCK-AI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 05 Nos |
| 309 | Supply, installation, Testing andcommissioningof THIRD FLOOR -L & PPANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.THIRD FLOOR -L & PPANEL- BLOCK-BI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED MCCB - 07 Nos 63A FP MCB 10KA - 04 Nos |
| 310 | Supply, installation, Testing andcommissioningof FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-AI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 63A FP MCB 10KA - 10 Nos |
| 311 | Supply, installation, Testing andcommissioningof FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & PPANEL- BLOCK-BI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 08 Nos |
| 312 | Supply, installation, Testing andcommissioningof EIGTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.EIGHTH FLOOR -L & PPANEL- BLOCK-AI/C-800A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 800A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-100A FP MCCB 25kA TM BASED MCCB - 08 Nos 63A FP MCB 10KA - 06 Nos |
| 313 | Supply, installation, Testing andcommissioningof EIGTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.EIGHTH FLOOR -L & PPANEL- BLOCK-BI/C-800A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 800A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-100A FP MCCB 25kA TM BASED MCCB - 06 Nos 200A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 07 Nos |
| 314 | Supply, installation, Testing andcommissioningof NINTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.NINTH FLOOR -L & PPANEL- BLOCK-AI/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-200A FP MCCB 25kA TM BASED MCCB - 03 Nos 100A FP MCCB 25kA TM BASED MCCB - 02 Nos63A FP MCB 10KA - 07 Nos |
| 315 | Supply, installation, Testing andcommissioningof NINTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.NINTH FLOOR -L & PPANEL- BLOCK-BI/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 03 Nos63A FP MCB 10KA - 05 Nos |
| 316 | Supply, installation, Testing andcommissioningof TENTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.TENTH FLOOR -L & PPANEL- BLOCK-AI/C- 200A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 63A FP MCB 10KA- 10 Nos100A FP MCCB 25kA TM BASED MCCB - 01 Nos200A FP MCCB 25kA TM BASED MCCB - 01 Nos |
| 317 | Supply, installation, Testing andcommissioningof TENTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.TENTH FLOOR -L & PPANEL- BLOCK-BI/C- 250A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 250A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 63A FP MCB 10KA- 08 Nos100A FP MCCB 25kA TM BASED MCCB - 02 Nos200A FP MCCB 25kA TM BASED MCCB - 02 Nos |
| 318 | Supply, installation, Testing andcommissioningof ELEVENTH FLOOR -L & P PANEL- BLOCK-A & B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.ELEVENTH FLOOR -L & PPANEL- BLOCK-A & BLOCK-BI/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G-200A FP MCCB 25kA TM BASED MCCB - 03 Nos 100A FP MCCB 25kA TM BASED MCCB - 01 Nos63A FP MCB 10KA - 08 Nos |
| 319 | Supply, installation, Testing andcommissioningof TWELFTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.TWELFTH FLOOR -L & PPANEL- BLOCK-AI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 14 Nos |
| 320 | Supply, installation, Testing andcommissioningof TWELFTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.TWELFTH FLOOR -L & PPANEL- BLOCK-BI/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 200A FP MCCB 25kA TM BASED MCCB - 03 Nos 63A FP MCB 10KA - 10 Nos |
| 321 | Supply, installation, Testing andcommissioningof GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A - I/C- 200A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking. 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED - 02 Nos 100A FP MCCB 25kA TM BASED - 07 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 322 | Supply, installation, Testing andcommissioningof GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 1600A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking. 1600A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 630A FP MCCB 25KA TM BASED - 02 Nos 400A FP MCCB 25KA TM BASED - 04 Nos 200A FP MCCB 25kA TM BASED - 05 Nos 100A FP MCCB 25kA TM BASED - 03 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 323 | Supply, installation, Testing andcommissioningof FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A-I/C- 1600A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 1600A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 630A FP MCCB 25KA TM BASED - 02 Nos 400A FP MCCB 25KA TM BASED - 04 Nos 200A FP MCCB 25kA TM BASED - 05 Nos 100A FP MCCB 25kA TM BASED - 03 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 324 | Supply, installation, Testing andcommissioningof FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 1600A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking . 1600A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 630A FP MCCB 25KA TM BASED - 02 Nos 400A FP MCCB 25KA TM BASED - 04 Nos 200A FP MCCB 25kA TM BASED - 05 Nos 100A FP MCCB 25kA TM BASED - 03 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 325 | Supply, installation, Testing andcommissioningof SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A- I/C- 630A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED - 04 Nos 100A FP MCCB 25kA TM BASED - 06 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 326 | Supply, installation, Testing andcommissioningof SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 200A FP MCCB 25kA TM BASED - 02 Nos 100A FP MCCB 25kA TM BASED - 05 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 327 | Supply, installation, Testing andcommissioningof THIRD FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.THIRD FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A - I/C- 200A 4P MP, 25kA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED - 05 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 328 | Supply, installation, Testing andcommissioningof NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A - I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED - 11 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 329 | Supply, installation, Testing andcommissioningof NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-BI/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED - 11 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 330 | Supply, installation, Testing andcommissioningof ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A- I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED - 11 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 331 | Supply, installation, Testing andcommissioningof ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below.ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP MCCB 25kA TM BASED - 11 NosAll outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring.All MCB outgoings shall have ON indication lamp. |
| 332 | Supply, installation, Testing andcommissioningof AHU PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.AHU PANEL- BLOCK- A & BLOCK- B - I/C-400A 4P MP, 36kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP 25kA TM BASEDMCCB-12 NosAll MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 333 | Supply, installation, Testing andcommissioningof AHU PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.AHU PANEL- BLOCK- A & BLOCK- B - I/C- 250A 4P MP, 36kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 250A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP 25kA TM BASEDMCCB-12 NosAll MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 334 | Supply, installation, Testing andcommissioningof AHU PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.AHU PANEL- BLOCK- A & BLOCK- B - I/C- 100A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 100A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 63A FP 25kA TM BASEDMCCB-12 NosAll MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 335 | Supply, installation, Testing andcommissioningof AHU PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.AHU PANEL- BLOCK- A & BLOCK- B - I/C- 200A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 100A FP 25kA TM BASEDMCCB-8 NosAll MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 336 | Supply, installation, Testing andcommissioningof PLUMBING PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.PLUMBING PANEL-I/C- 200A 4P MP, 25kA. MCCB - 1 Nos 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 16 nos of MCCB/MPCB wih starter SUITABLE FOR 10HP MOTOR as per type 2 Coordination chart + 3 SPARE of same rating (Provision only)All MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 337 | Supply, installation, Testing andcommissioningof BASEMENT VENTILATION PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below.BASEMENT VENTILATIONPANEL-I/C- 400A 4P MP, 36kA. MCCB - 1 Nos400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 6 nos of MCCB/MPCBwith starter SUITABLE FOR 20HP MOTOR+ 2 SPARE for same rating (Provision only) & 5 nos of MCCB/MPCBwith starter SUITABLE FOR 4HP MOTOR as per type 2 Coordination chart + 2 SPARE for same rating (Provision only)All MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 338 | Supply, installation, Testing andcommissioningof STAIRCASE LIFT PRESSURISATION PANEL. All incomershall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. STAIRCASE LIFT PRESSURISATIONPANEL-I/C- 630A 4P MP, 36kA. MCCB - 1 Nos630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- 4 nos of MCCB/MPCBwith starter SUITABLE FOR 40HP MOTOR + 1 SPARE (Provision only), 3 nos of MCCB/MPCBwith starter SUITABLE FOR 20HP MOTOR + 1 SPARE (Provision only), 12 nos of MCCB/MPCBwith starter SUITABLE FOR 7HP Motor & 2 nos of MCCB/MPCBwith starter SUITABLE FOR 16HP Motor as per type 2 Coordination chart + 1 SPARE (Provision only)All MCB outgoings shall have ON indication lamp.All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. |
| 339 | Supply, installation, Testing andcommissioningof MAIN HVAC PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.MAIN HVAC PANEL-I/C 3200A, 4P, 50kA, EDO, LSIG ACBIncomer ACBwith tripping mechanism in case of Fire- 1 No2500A 50kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS.O/G- a) MCCB for 400KW with VFD with Bypass Arrangement Starters forPrimary Pumps(4W+1SB) for Chiller b) MCCB for 25KW with VFD with Bypass Arrangement Starters for Primary Pumps (4W+1SB) c)400A, 4P, 36kA, MP, MCCB - 01 No for secondary Pump control Paneld) MCCBs for 12KW with VFD with Bypass Arrangement Starters for Cooling Tower Fans (4W + 1SB )e) MCCBs for 80KW with VFD with Bypass Arrangement Starters for Condenser water Pumps as per pump specification (4W + 1SB)f)Spare MCCB20%All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS |
| 340 | Supply, installation, Testing andcommissioningof 20 HP STARTER PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. 20 HP, 3 PHASE Motor Starter panels wall mounted type made out of 2/1.6millimetrethick steel sheet duly painted and comprising of following. The panel shall be compatible for integration with BMS system with required NO+NC contacts. Meters shall be digital type.All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS 1 No. TPN MPCB with inbuilt over load relay of 25 KA breaking capacity. 1 Set Phase indication lamps with protection fuse.1 No. ON indication lamp with protection fuse.1 Set \"Start/ Stop\" push button.1 No. 24 Volt Transformer. (for AHU panels only). 1 No. A millimetre eter of suitable range with 1CT. TP power contactors (AC3 Duty). Voltmeter and a millimetre eter with selector switch. Time delay relay for delayed automatic restart of air handling unit motor(0-180 Sec) wiring for microswitch for starting/stopping the fan when fire damper closes |
| 341 | Supply, installation, Testing andcommissioningof 15HP STARTER PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. 20 HP, 3 PHASE Motor Starter panels wall mounted type made out of 2/1.6millimetrethick steel sheet duly painted and comprising of following. The panel shall be compatible for integration with BMS system with required NO+NC contacts. Meters shall be digital type.All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS 1 No. TPN MPCB with inbuilt over load relay of 25 KA breaking capacity. 1 Set Phase indication lamps with protection fuse.1 No. ON indication lamp with protection fuse.1 Set \"Start/ Stop\" push button.1 No. 24 Volt Transformer. (for AHU panels only). 1 No. A millimetre eter of suitable range with 1CT. TP power contactors (AC3 Duty). Voltmeter and a millimetre eter with selector switch. Time delay relay for delayed automatic restart of air handling unit motor(0-180 Sec) wiring for microswitch for starting/stopping the fan when fire damper closes |
| 342 | Supply, installation, Testing andcommissioningof 10 HP STARTER PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. 20 HP, 3 PHASE Motor Starter panels wall mounted type made out of 2/1.6millimetrethick steel sheet duly painted and comprising of following. The panel shall be compatible for integration with BMS system with required NO+NC contacts. Meters shall be digital type.All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS 1 No. TPN MPCB with inbuilt over load relay of 25 KA breaking capacity. 1 Set Phase indication lamps with protection fuse.1 No. ON indication lamp with protection fuse.1 Set \"Start/ Stop\" push button.1 No. 24 Volt Transformer. (for AHU panels only). 1 No. A millimetre eter of suitable range with 1CT. TP power contactors (AC3 Duty). Voltmeter and a millimetre eter with selector switch. Time delay relay for delayed automatic restart of air handling unit motor(0-180 Sec) wiring for microswitch for starting/stopping the fan when fire damper closes |
| 343 | Supply, installation, Testing andcommissioningof 7.5 HP STARTER PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. 20 HP, 3 PHASE Motor Starter panels wall mounted type made out of 2/1.6millimetrethick steel sheet duly painted and comprising of following. The panel shall be compatible for integration with BMS system with required NO+NC contacts. Meters shall be digital type.All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS 1 No. TPN MPCB with inbuilt over load relay of 25 KA breaking capacity. 1 Set Phase indication lamps with protection fuse.1 No. ON indication lamp with protection fuse.1 Set \"Start/ Stop\" push button.1 No. 24 Volt Transformer. (for AHU panels only). 1 No. A millimetre eter of suitable range with 1CT. TP power contactors (AC3 Duty). Voltmeter and a millimetre eter with selector switch. Time delay relay for delayed automatic restart of air handling unit motor(0-180 Sec) wiring for microswitch for starting/stopping the fan when fire damper closes |
| 344 | Supply, installation, Testing andcommissioningof 5 HP STARTER PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. 20 HP, 3 PHASE Motor Starter panels wall mounted type made out of 2/1.6millimetrethick steel sheet duly painted and comprising of following. The panel shall be compatible for integration with BMS system with required NO+NC contacts. Meters shall be digital type.All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS 1 No. TPN MPCB with inbuilt over load relay of 25 KA breaking capacity. 1 Set Phase indication lamps with protection fuse.1 No. ON indication lamp with protection fuse.1 Set \"Start/ Stop\" push button.1 No. 24 Volt Transformer. (for AHU panels only). 1 No. A millimetre eter of suitable range with 1CT. TP power contactors (AC3 Duty). Voltmeter and a millimetre eter with selector switch. Time delay relay for delayed automatic restart of air handling unit motor(0-180 Sec) wiring for microswitch for starting/stopping the fan when fire damper closes |
| 345 | Supply, installation, Testing andcommissioningof 3 HP STARTER PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall haveon / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sq millimetre ) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. 20 HP, 3 PHASE Motor Starter panels wall mounted type made out of 2/1.6millimetrethick steel sheet duly painted and comprising of following. The panel shall be compatible for integration with BMS system with required NO+NC contacts. Meters shall be digital type.All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS All outgoing shall be provided with stop/manual/auto selector switch to facilitate operation through BMS 1 No. TPN MPCB with inbuilt over load relay of 25 KA breaking capacity. 1 Set Phase indication lamps with protection fuse.1 No. ON indication lamp with protection fuse.1 Set \"Start/ Stop\" push button.1 No. 24 Volt Transformer. (for AHU panels only). 1 No. A millimetre eter of suitable range with 1CT. TP power contactors (AC3 Duty). Voltmeter and a millimetre eter with selector switch. Time delay relay for delayed automatic restart of air handling unit motor(0-180 Sec) wiring for microswitch for starting/stopping the fan when fire damper closes |
| 346 | Supply, installation, testing &commissioningof VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and progra millimetre ing facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and theinter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 10.0 HP/ 7.5 KW |
| 347 | Supply, installation, testing &commissioningof VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and progra millimetre ing facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and theinter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 7.5 HP/ 5.6 KW |
| 348 | Supply, installation, testing &commissioningof VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and progra millimetre ing facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and theinter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 5.0 HP/ 3.73 KW |
| 349 | Supply, installation, testing &commissioningof VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and progra millimetre ing facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and theinter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 3.0 HP/ 2.2 KW and below rating |
| 350 | Supplying, installing, testing andcommissioningair circuit breaker manual drawout type, 650V, 1250A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB |
| 351 | Supplying, installing, testing andcommissioningair circuit breaker manual drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close indication, individual fault trip indication, indications for alarm and trip, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB |
| 352 | Supplying, installing, testing andcommissioningair circuit breaker manual drawout type, 650V, up to 800A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s),with standard accessories and with ready to close, individual fault trip, alarm and tripindication, mechanical and electrical anti pumping, soft/hard rating plug (includinghard rating plug CT) with Micro-processer based LCD display release withLSIG and temperature rise protection & with 4 C/O contacts for On-OffTrip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB |
| 353 | Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. |
| 354 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 355 | Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 356 | Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 357 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 358 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 359 | Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8) |
| 360 | Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8) |
| 361 | Supplying and erecting terminal spreaders suitable for 4 pole, above 400A up to 630A MCCB (Set of 8) |
| 362 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. |
| 363 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB. |
| 364 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 365 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring &connections etc. For On/Off /Trip. |
| 366 | Supplying and erecting mains with 3x2.5 sq. millimetreFRLSH copperPoly vinyl chlorideinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 367 | Supplying and erecting GI sheet 1.6millimetre(16 SWG) caution board of size 200 x 150millimetreduly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 |
| 368 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq.millimetre . with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP BB |
| 369 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 370 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 371 | Supply, installation, testing andcommissioningof Aluminum 250A 40kA SC for 1 sec Air Insulated type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 372 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT. |
| 373 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT. |
| 374 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT. |
| 375 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT. |
| 376 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 250A 40kA Air Insulated type BBT. |
| 377 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 250A 40kA Air Insulated type BBT. |
| 378 | Supply, installation, testing andcommissioningof Aluminum 400A 40kA SC for 1 sec Air Insulated type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 379 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT. |
| 380 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT. |
| 381 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT. |
| 382 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT. |
| 383 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 400A 40kA Air Insulated type BBT. |
| 384 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 400A 40kA Air Insulated type BBT. |
| 385 | Supply, installation, testing andcommissioningof Aluminum 800A 40kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 386 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT. |
| 387 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT. |
| 388 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 800A 40kA Air Insulated type BBT. |
| 389 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT. |
| 390 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 800A 40kA Sandwich type BBT. |
| 391 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 800A 40kA Sandwich type BBT. |
| 392 | Supply, installation, testing andcommissioningof Aluminum 1000A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 393 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT. |
| 394 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT. |
| 395 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 1000A 50kA Air Insulated type BBT. |
| 396 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT. |
| 397 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 1000A 50kA Sandwich type BBT. |
| 398 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 1000A 50kA Sandwich type BBT. |
| 399 | Supply, installation, testing andcommissioningof Aluminum 1250A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 400 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT. |
| 401 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT. |
| 402 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 1250A 50kA Air Insulated type BBT. |
| 403 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT. |
| 404 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 1250A 50kA Sandwich type BBT. |
| 405 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 1250A 50kA Sandwich type BBT. |
| 406 | Supply, installation, testing andcommissioningof Aluminum 1600A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 407 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT. |
| 408 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT. |
| 409 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 1600A 50kA Air Insulated type BBT. |
| 410 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT. |
| 411 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 1600A 50kA Sandwich type BBT. |
| 412 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 1600A 50kA Sandwich type BBT. |
| 413 | Supply, installation, testing andcommissioningof Aluminum 2000A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 414 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT. |
| 415 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT. |
| 416 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 2000A 50kA Air Insulated type BBT. |
| 417 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT. |
| 418 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 2000A 50kA Sandwich type BBT. |
| 419 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 2000A 50kA Sandwich type BBT. |
| 420 | Supply, installation, testing andcommissioningof Aluminum 2500A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition |
| 421 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 2500A 50kA Sandwich type BBT. |
| 422 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 2500A 50kA Sandwich type BBT. |
| 423 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 2500A 50kA Air Insulated type BBT. |
| 424 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT. |
| 425 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for vertical Aluminum 2500A 50kA Sandwich type BBT. |
| 426 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 2500A 50kA Sandwich type BBT. |
| 427 | Supply, installation, testing andcommissioningof Aluminum 3200A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers as per design requirement & site condition |
| 428 | Supply, installation, testing andcommissioningof Aluminum3200A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5 millimetreElectro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 65 for outdoor with canopy. The total bus bar assembly & installaion at site must comply Seismic zone 4 or above. Straight length of feeder / plug in type with hanging brackets, end covers as per design requirement & site condition |
| 429 | Supply, installation, testing andcommissioningof Flange end with Adaptor box, Copper flexiblesas per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT. |
| 430 | Supply, installation, testing andcommissioningof 90 Degree Elbow / T Elbowas per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT. |
| 431 | Supply, installation, testing andcommissioningof End Feed Unit as per design requirement & site condition suitable for Aluminum 3200A 50kA Air Insulated type BBT. |
| 432 | Supply, installation, testing andcommissioningof Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT. |
| 433 | Supply, installation, testing andcommissioningof Support hanger as per site condition suitable for verticalAluminum 3200A 50kA Sandwich type BBT. |
| 434 | Supply, installation, testing andcommissioningof Fabrication Support & hardware suitable for Aluminum 3200A 50kA Sandwich type BBT. |
| 435 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 100 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 436 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 200 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 437 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 250 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 438 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 400 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 439 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 630 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 440 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 800 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 441 | Supply, installation, testing andcommissioningof Tap off box tested as per IEC 61439-6 of 1600 A Tap off box (IP-54) made of 1.6 millimetrethick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4PLSI with earthing connection point & safelty interlock |
| 442 | Supply, installation, Testing &commissioningof10KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 443 | Supply, installation, Testing &commissioningof15KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 444 | Supply, installation, Testing &commissioningof20KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 445 | Supply, installation, Testing &commissioningof30KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 446 | Supply, installation, Testing &commissioningof40KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 447 | Supply, installation, Testing &commissioningof60KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 448 | Supply, installation, Testing &commissioningof80KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 449 | Supply, installation, Testing &commissioningof120KVA UPS .as per IS 13314 & IS 11260 having following capacity & features:-Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output.UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quotedprice shall be inclusiveofrequired rating single core copper conductor cable including terminations,connections ofUPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge. |
| 450 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire,duly charged with 24 months warranty complete |
| 451 | Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete |
| 452 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 453 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no.CB-LT/AL |
| 454 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 35 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 455 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 50 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no.CB-LT/AL |
| 456 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 70 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no.CB-LT/AL |
| 457 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 95 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no.CB-LT/AL |
| 458 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 120 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 459 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 150 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no.CB-LT/AL |
| 460 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 185 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 461 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½core 240 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 462 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 300 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL |
| 463 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 400 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 464 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq.millimetre . copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 465 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq.millimetre . copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 466 | Supplying, erecting & terminating XLPE armoured cable 3 core 6 sq.millimetre . copper conductor continuous 5.48 sq.millimetre . (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU |
| 467 | Supplying, erecting & terminating XLPE armoured cable 3 core 10 sq.millimetre . copper conductor continuous 5.48 sq.millimetre . (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU |
| 468 | Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq.millimetre . copper conductor continuous 5.48 sq.millimetre . (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No.CB-LT/CU |
| 469 | Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq.millimetre . copper conductor continuous 5.48 sq.millimetre . (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No.CB-LT/CU |
| 470 | Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq.millimetre . copper conductor continuous 5.48 sq.millimetre . (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No.CB-LT/CU |
| 471 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq.millimetre . copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 472 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sqmillimetre ., with necessary material as per specification No. CB-JT/LT |
| 473 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sqmillimetre ., with necessary material as per specification No. CB-JT/LT |
| 474 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sqmillimetre ., with necessary material as per specification No. CB-JT/LT |
| 475 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq.millimetre ., with necessary material as perspecification No. CB-JT/LT |
| 476 | Providing & erecting epoxy straight through joint outdoor/indoor for LTXLPE armoured cable 240 sq. millimetre ., with necessary material as per specificationNo. CB-JT/LT |
| 477 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 300 sqmillimetre ., with necessary material as per specificationNo. CB-JT/LT |
| 478 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 400 sqmillimetre ., with necessary material as per specificationNo. CB-JT/LT |
| 479 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sqmillimetre ., with necessary material as perspecification No. CB-JT/LT |
| 480 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sqmillimetre ., with necessary material as perspecification No. CB-JT/LT |
| 481 | Providing & erecting epoxy outdoor / indoor end termination kit for LTXLPE armoured cable 70 to 120 sqmillimetre ., with necessary material as perspecification No. CB-JT/LT |
| 482 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 150 to 185 sqmillimetre ., with necessary material as perspecification No. CB-JT/LT |
| 483 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sqmillimetre ., with necessary material as perspecification no. CB-JT/LT |
| 484 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 400 sqmillimetre ., with necessary material as per specificationNo. CB-JT/LT |
| 485 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from16SWG GI sheet of 150 millimetrewidth & 75 millimetreheight complete with necessary coupler plates & hardware. |
| 486 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from16 SWG GI sheet of 200 millimetrewidth & 75 millimetreheight complete with necessary coupler plates & hardware. |
| 487 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16SWG GI sheet of 300 millimetrewidth & 75 millimetreheight complete with necessary coupler plates & hardware. |
| 488 | Providing & erecting hot dipped galvanised perforated type cable traymanufactured from16SWG GI sheet of 500 millimetrewidth &75 millimetreheightcomplete with necessary coupler plates & hardware. |
| 489 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2millimetrethick) GI sheet of 150millimetre width & 20millimetreheight complete with necessary hardware. |
| 490 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2millimetrethick) GI sheet of 200millimetre width & 20millimetreheight complete with necessary hardware. |
| 491 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2millimetrethick) GI sheet of 300millimetre width & 20millimetreheight complete with necessary hardware. |
| 492 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2millimetrethick) GI sheet of 500millimetre width & 20millimetreheight complete with necessary hardware. |
| 493 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16SWG GI sheet of 200 millimetrewidth & 100 millimetreheight with required standard accessories. |
| 494 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16SWG GI sheet of 400 millimetrewidth & 100 millimetreheightwith required standard accessories. |
| 495 | 8 WAY SPN DBSupplyingand erecting single pole and neutral distributionboard (SPNDB)surface/flush mounted with 2 polesfor incoming and 6 poles for outgoing SP MCB‟son iron/ GI frame as per specification no. SW-SWR/MCBDB |
| 496 | 12 WAY SPN DBSupplyingand erecting single pole and neutral distributionboard (SPNDB) with door surface/flush mountedwith 2 polesfor incoming and 10 poles for outgoing SP MCB‟son iron/ GI frameas per specification no. SW-SWR/MCBDB |
| 497 | 4 WAY TPN DBSupplying&erectingtriplepole and neutral distribution board (TPNDB) with door surface/ flushmountedSPMCB of 12 poles, on iron /GIframe (horizontal busbar type)as per specification no.SW-SWR/MCBDB |
| 498 | 8 WAY TPN DBSupplying&erectingtriplepole and neutral distribution board (TPNDB) with door surface/ flushmounted SPMCB of 24 poles, on iron/ GI frame/wooden board.(horizontal busbar type)as perspecification no. SW-SWR/MCBDB |
| 499 | 12 WAY TPN DBSupplying&erectingtriplepoleand neutral distribution board (TPNDB) with door surface/ flushmounted SPMCB of 36 poles on iron/ GI frame (horizontal busbar type)as per specification no.SW-SWR/MCBDB |
| 500 | 4 WAY VTPN DBSupplyinganderectingtriplepole and neutral distribution board (TPNDB) surface/ flushmounted SP/TP MCBs of12 poles/4 wayson iron / GI frame (vertical busbar type)as per specification no. SW-SWR/MCBDB |
| 501 | 8 WAY VTPN DBSupplyinganderectingtriplepoleand neutral distribution board (TPNDB) surface/ flushmounted SP / TP of 24 poles/ 8 ways on iron / GI frame(vertical busbar type)as per specificationno. SW-SWR/MCBDB |
| 502 | 12 WAY VTPN DBSupplying&erectingtriplepoleand neutral distribution board(TPNDB) surface/ flushmounted SP / TPMCB of36 poles/12ways on iron / GI frame (vertical busbar type) as per specificationno. SW-SWR/MCBDB |
| 503 | Supplying, erecting & marking SPMCB 6A to 32A, C-series (formotor / power) in provided distribution board as per specificationno. SW-SWR/MCB |
| 504 | Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB |
| 505 | Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
| 506 | Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB |
| 507 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short- circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 508 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short- circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 509 | Supplying, fixing andcommissioning2 pole,RCBO (residual current breaker with overcurrentshort circuit 10 kA and earth leakage protection),with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SWRCCB/RCBO |
| 510 | Supplying, fixing andcommissioning2 pole RCBO(residual current breaker with overcurrentshort circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40Aas per specification no SW-RCCB/RCBO |
| 511 | Supplying, fixing andcommissioning2 pole RCBO(residual current breaker with overcurrentshort circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A, as per specification no SW-RCCB/RCBO |
| 512 | Supplying, fixing andcommissioning4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO |
| 513 | Supplying, fixing andcommissioning4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO |
| 514 | Supplying, erecting &commissioning2 pole Reinforced cement concrete B 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 515 | Supplying, erecting &commissioning2 pole Reinforced cement concrete B 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 516 | Supplying, erecting &commissioning2 pole Reinforced cement concrete B 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 517 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2 millimetrethickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 518 | Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20millimetre Poly vinyl chlorideconduit / casing n capping with 1.5 sq. millimetre . (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW. Average Length 6M. |
| 519 | Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20millimetre Poly vinyl chlorideconduit / casing n capping with 1.5 sq. millimetre . (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. Average Length 8M. |
| 520 | Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20millimetre Poly vinyl chlorideconduit / casing n capping with 1.5 sq. millimetre . (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. Average Length 10M. |
| 521 | Secondary point wiring for additional light/ bell point, concealed type in min 20millimetre Poly vinyl chlorideconduit with 1.5 sq. millimetre . (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 522 | Supplying and erecting mains with 3x2.5 sq. millimetreFRLSH copperPoly vinyl chlorideinsulated wire laid in provided conduit / trunking / insidepole / Busbars or anyother places as per specification No: WG-MA/BW |
| 523 | Supplying and erecting mains with 3x4sq. millimetreFRLSH copperPoly vinyl chlorideinsulated wire laid in provided conduit/trunking /insidepole / Busbars or anyother placesas per specification No: WG-MA/BW |
| 524 | Supplying and erecting mains with 3x6sq. millimetreFRLSH copperPoly vinyl chlorideinsulated wire laid in provided conduit /trunking/ insidepole / Busbars or anyother placesas per specification No: WG-MA/BW |
| 525 | Supplying and erecting mains with 3x10sq. millimetreFRLSH copperPoly vinyl chlorideinsulated wire laid in provided conduit/trunking/inside pole/Busbars or any other places as per specification No: WG-MA/BW |
| 526 | Concealing of provided G.I. pipe/H.G. screwedconduit/ Poly vinyl chloridepipe in wall/floor/false ceiling complete as per specification No: WG-PW/CW |
| 527 | Supplying and erectingHMSPoly vinyl chlorideconduit FRLSgrade 20 millimetrediameterwith necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 528 | Supplying and erecting HMSPoly vinyl chlorideconduit FRLS grade 25 millimetre diameter with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 529 | Supplying and erectingHMS Poly vinyl chloride conduit FRLSgrade 32 millimetrediameterwith necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 530 | Wiring for plug on board with modular Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 531 | Supplying and erecting modular type switch 6A/10A duly erected on provided plate and box with wiring connections complete. |
| 532 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 533 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 534 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 535 | Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 536 | Supplying and erecting ISI mark modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 537 | Supplying and erecting lumiNous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board |
| 538 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.. |
| 539 | Supplying and erecting unbreakable concealed type modular switch box withdouble mounting plate for 2 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 540 | Supplying and erecting unbreakable concealed type modular switch box withdouble mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 541 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 542 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 543 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 544 | Supplying and erecting unbreakable concealed type modular switch box withdouble mounting plate for 12 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 545 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 546 | Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 547 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 548 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 549 | Supplying and erecting LED Panel Light(600 millimetreX 600 millimetre ) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 550 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on providedPoly vinyl chlorideBlock / wooden board with 3 years warranty. |
| 551 | Supplying and erecting CRCA /die-cast aluminium powder coatedhousing Bottom Opening Clean Room LED Luminaries 24 W with provision for plane front frame with translucent cover fixed to the housing complete.(indirect light) |
| 552 | Supplying and erecting CRCA /die-cast aluminium powder coatedhousing Bottom Opening Clean Room LED Luminaries 36 W with provision for plane front frame with translucent cover fixed to the housing complete.(indirect light) |
| 553 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty |
| 554 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on providedPoly vinyl chlorideBlock / wooden board with 3 years warranty |
| 555 | Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 x 20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S./ steel body suitable to work on 230V, AC Supply having top mounting arrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty |
| 556 | Supplying and erecting regular / standard model ceiling fan of 900/1050 millimetre . sweep complete erected in position as per specification no. FG-FN/CF |
| 557 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200millimetre , max. energy consumption of 28W having service ratio (C millimetre /W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 558 | Supplying and erecting regular/standard model ceiling fan of 1400 millimetresweep complete erected in position as per specification no. FG-FN/CF |
| 559 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10millimetredia x 75millimetrelong with necessary materials for ceiling fan. |
| 560 | Supplying and erecting fan hook box of 10millimetreM.S. round bar bounded to theReinforced cement concretebars upto 50millimetrelength each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100millimetre diameter or equivalent square size and having depth upto 75millimetrecomplete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and within any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 561 | Supplying and erecting „B‟ class G.I. pipe / M.S. pipe down rod duly painted for fan complete erected withPoly vinyl chloridethree core flexible cable 1 sq.millimetrecopperPoly vinyl chloridewire. |
| 562 | Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250millimetre . /300millimetre . sweep complete with necessary brackets for fixing cabin fans, wire etc |
| 563 | Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450millimetre . 1400 RPM complete erected in position as per specification no. FG-FN/EXF |
| 564 | Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155millimetreA/F, top 70millimetreA/F on provided foundation as per specification no. OHPL/ OPL |
| 565 | Providing and erecting galvanised 1000 millimetresingle arm sword type bracket with FRP dome and ball as per specification no. OHPL/ PBKT |
| 566 | Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG ODF/FLS2. |
| 567 | Supplying & erecting water tight terminal box of 1.6millimetre(16 gauge) CRCA sheet of size 150 x 100 x 100millimetrecomplete on pole as per specification no. CB-SB with Bakelite connector. |
| 568 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq.millimetre . copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 569 | Providing pipe type earthing with 40 millimetre .diameterG.I. pipe or 20millimetre diameterG.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 570 | Making cement concrete foundation including excavation (60 x 60 x 150)centimetredeep in 1:3:6 cement concrete 20 x 25millimetrestone metal, (45 x 45 x 45)centimetre/45centimetre diameterx 45centimetreheight plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) |
| 571 | Supplying and laying (including excavation of suitable width & depth up to 90centimetre ) 120millimetreoutsidediameterdouble wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 572 | Supplying & erecting CRCA sheet metal enclosures of 1.2 millimetrethickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short- circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. |
| 573 | Supplying, erecting, testing andcommissioningselfcontained water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres/hr and storage capacity 120 litres with partially stainless steel body complete.specification no. AP-WCR/WC |
| 574 | Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system.(FOR TDS more than 200) |
| 575 | Supply and erecting of Occupancy sensor light switch having a coverage of min. 6 metre dia at 3.6 metre with site adjustable off timing and instant ON / OFF. |
| 576 | Providing earthing with copper earth plate size 60 x 60 x 0.315centimetrewith funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA |
| 577 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6centimetrewith funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification No. EA-EP |
| 578 | Supply, Installation, Testing andcommissioningof maintenance free earthing comprising of Electrode of 17.2millimetrediameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantitycomplete. Specification No. EA-MOBI |
| 579 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bitumiNous paint in an approved manner with joints required. As per specification No. EA-EP. |
| 580 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bitumiNous paint in an approved manner with joints required. As per specification No EA-EP. |
| 581 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 582 | Supplying, erecting & terminating XLPE unarmoured cable 1 core 25 sq.millimetre . copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU |
| 583 | Supplying, erecting & terminating XLPE unarmoured cable 1 core 50 sq.millimetre . copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU |
| 584 | Air-termination Rod having height- 1000millimetre , to be mounted on side walls. It is of Material- AlMgSi, ofDiameter Ø 16millimetre, & Complied as per StandardEN 62561-2. Part No. IVANAH EL-IV-1111604 |
| 585 | Side Wall Clamp to fix Air Termination Rod on side walls. Material : SS.Complied as per Standard.EN 62561-2.Part No. IVANAH EL-IV-1229001 |
| 586 | ATR Clamp One Cubic MetreConnector,to mount on Air Terminator Rod & to connect two conductors on roof. Material : Al , Complied as per StandardEN - 62561-2 Part No. IVANAH EL-IV-1119001 |
| 587 | Roof Conductor / Mesh / Down Conductors, of Diameter Ø8millimetre , Cross-section- 50 Sq. millimetre , of Material- AlMgSi & Complied as per Standard EN 62561-2 Part No. IVANAH EL-IV-1210801 |
| 588 | Press to Fit type Conductor Holder, 20millimetreclearance height. Holding Range 8 -10millimetre . Matl.: S.S.Complied as per Standard EN 62561-1.Part No. IVANAH EL-IV-1222001 |
| 589 | Extension Pieces, connected by straight connector. Material - Al MgSi, DimensionØ8millimetrehaving Length app. 395millimetre& Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1219001 |
| 590 | Splicer / Straight Connector which is used to connect the end points of two conductors of size 8-10millimetre . Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1219002 |
| 591 | Multi Clamp / MV clamp, to conduct two conductors, round to round, which are laid acrooss. Material- Steel, with clamping range Rd 8-10millimetre , & Complied as per Standard EN 62561-1. Part No. IVANAH EL-IV-1229002 |
| 592 | Cross Connector Round to Round type,to conduct two conductors,which are laid acrooss. Also to hold down conductors connected from roof conductors. Material- SS, with clamping range Rd 8-10millimetre , & Complied as per StandardEN 62561-1.Part No. IVANAH EL-IV-1329011 |
| 593 | Horizontal Ring Conductors, of Diameter Ø8millimetre , Cross-section- 50 Sq. millimetre , of Material- AlMgSi & Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1210801 |
| 594 | Press to Fit type Conductor Holder, 20millimetreclearance height. Holding Range 8 -10millimetre . Matl.: S.S.Complied as per Standard EN 62561-1. |
| 595 | Strike Pad is fixed on connected M8 - Stud. The M8 - Studhas been connected by MV Clamp to the concealed horizontal conductor ring of size Dia10millimetreSS round bar. This is Complied as per EN 62561-2. |
| 596 | Down Conductors, of Diameter Ø8millimetre , Cross-section- 50 Sq. millimetre , of Material- AlMgSi & Complied as per Standard EN 62561-2 |
| 597 | Press to Fit type Conductor Holder, 20millimetreclearance height. Holding Range 8 -10millimetre . Matl.: S.S.Complied as per Standard EN 62561-1. |
| 598 | Splicer / Straight Connector which is used to connect the end points of two conductors of size 8-10millimetre . Complied as per Standard EN 62561-2. |
| 599 | Lightning Flash Counter / Lightning Strike Counter IVANAH make - 6 digit,Working electro mechanically without any power supply. Equipment should count lightning strokes of 0.4KA to 100 KA at the 8/20us standard. |
| 600 | Disconnecting clamp, Round to Flat type, forconnecting/disconnecting, suitable for Round Conductor of dia 8millimetre& flat sizeupto 30 millimetreconductor.Material : SS. Complied as per EN 62561-1. |
| 601 | Holderto hold Flat Conductor of Size 25X6millimetre , which is a Link to Earth Grid Ring. Material : S.S. |
| 602 | GI Flat Conductor as Link to Earth Grid Ring, of size 25 X 6 , Cross-section- 150 Sq. millimetre , of Material- GI,. Coating of 80 microns.Complied as per Standard |
| 603 | Cross Connector,Flat to Flat type, to connect two conductors which are laid acrooss. Material- Steel, with clamping range Flat size of 25X6 millimetre& Flat sizeof 25X6millimetre& Complied as per Standard EN 62561-1. |
| 604 | GI Flat Conductor as Earth Grid Ring, of size 25 X 6 , Cross-section- 150 Sq. millimetre , of Material- GI,. Coating of 80 microns.Complied as per StandardEN 62561-2. |
| 605 | Copper bonded Earthing Electrode is of low carbon Steel Rodand high tensile strength.The copper bonding is of min 250 microns /copper plating. on the outer surfaceof Diameter17.2millimetre , having Length- 3 meters. Its Terminal Plate of size 50X5X100millimetrelength. Complied as per EN 62561-2. Earth Electrode has been tested at CPRI for short time withstand current 18kA rms for 1 Sec. & Peak withstand current 45kA testand found OK.Advance Conductive Backfill Compound, ECO friendly, Non Corrosive, Hydroscopic based, ability to absorb moisture from surrounding Soil, low resistivity Ground Enhancement material 20 Kg Bags, to fill around any Earthing Electrode.Part No. IVANAHEL-IV4000001 Earthing Chamber Cover - Square, Material : Black Colour HDPE, Corrosion resistant, Tested for 5 Tons of Weight.Size - 300 X 300, Ht is 260millimetre . |
| 606 | Supplyinganderectingthree phase 10 to 60 A net meterDLMS compliance of accuracy class 1.0, 3 x 240V, 50 Hz,with backlitLCD display, optical port and RJ 232 port(measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh,V, I, kW, 6 months history of energy) with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer. |
| 607 | Supplying, installing, testing andcommissioningof 100 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD(THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contractas per Specification no. ESD-RT-ONG |
| 608 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. |
| 609 | FIRE FIGHTING SYSTEM ( HYDRANT & SPRINKLER) |
| 610 | Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clampfor erection on wall. |
| 611 | Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50millimetrex 6millimetreM.S.flat with nut and bolts grouted in wallcomplete. CSR 22-23(13-15-1) |
| 612 | Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500millimetrein length, 900millimetrein height frame made out of 30x30x4millimetre . angle iron with cross supports for legs, welded with 4hooks and duly painted with one coat of red lead and two coats of silver paint. |
| 613 | Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook . |
| 614 | Supplying, installation, testing andcommissioningof main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 140 to 120 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 93kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single/multi stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated co millimetre on base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, CSR 22-23(13-1-7) |
| 615 | Supplying, installation, testing andcommissioningof main fire pump (MFP/DP) suitable for water discharge of2850 LPM at 110 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50millimetrethick glass wool with 1.0millimetrethick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated co millimetre on base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete,CSR 22-23 (13-4-3) |
| 616 | Supplying, installation, testing andcommissioningof jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 140 to 110 m head drivenby electric motor 415 volts, 3 phase 50 Hz, AC supply of 15 kW or ofsuitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body& bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520. (b) Suitable kW Squirrel cage induction motor, TEFC, synchronous speed 3000RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation,conforming to IS-325.(c) M.S. fabricated co millimetre on base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/JP CSR 22-23(13-2-4) |
| 617 | Supplying, installation, testing andcommissioningof booster fire pump [BP]suitable for water discharge of 900 LPM at 35 m head driven by electricmotor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kWcapacityfor manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade),mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated co millimetre on base plate, coupling, coupling guard, foundation boltsetc. as required.(d)Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/B CSR 22-23 (13-3-2). |
| 618 | Supplying, erecting, testing &commissioningof fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2millimetre thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosureprotection class IP54, duly powder coated or painted with accessories dulypainted with two coats of synthetic enamel paint of fire red colour over a coat ofprimer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection withsuitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequatesize copper conductor cable, earth terminals, numbering etc. complete in allrespect, suitable for satisfactory operation of main fire pump and jockey(pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings, |
| 619 | Supplying and erecting G.I.pipe ‘C’class ERW 200millimetredia with necessary fittings complete as per specification no. FF-PPCSR 22-23 (13-6-8 ) |
| 620 | Supplying and erecting G.I.pipe ‘C’class ERW 150millimetredia with necessary fittings complete as per specification no. FF-PP CSR 22-23 ( 13-6-7 ) |
| 621 | Providing coating of bitumen paint & 4 millimetrethick wrapping for under ground 150millimetrering main of fire fighting system.CSR 22-23 (13-6-10) |
| 622 | Supplying and erecting G.I.pipe ‘C’class ERW 100millimetredia with necessary fittings complete asper specification no. FF-PP CSR 22-23 (13-6-6) |
| 623 | Supplying and erectingG.I. pipe‘C’ class ERW75/80millimetredia with necessary fittings complete asper specification no. FF-PP CSR 22-23 (13-6-5 ) |
| 624 | Supplying and erecting G.I.pipe ‘C’ class ERW 65 millimetredia with necessary fittings complete asper specification no. FF-PP CSR 22-23 (13-6-4) |
| 625 | Supplying and erecting G.I.pipe ‘C’ class ERW 50 millimetredia with necessaryfittings complete asper specification no. FF-PP CSR 22-23 (13-6-3) |
| 626 | Supplying and erecting ISI mark GI pipe 40 millimetre .dia‘C” class at position with accessories complete. Specification no. CW-PLB/GP.CSR 22-23 (16-5-11) |
| 627 | Supplying and erecting ISI mark GI pipe 32 millimetre .dia‘C” class at position with accessories complete. Specification no. CW-PLB/GP.CSR 22-23 (16-5-10) |
| 628 | Supplying and erecting G.I.pipe ‘C’ class ERW 25 millimetredia with necessaryfittings complete asper specification no. FF-PP CSR 22-23 ( 13-6-2 ) |
| 629 | Excavatingsoft Murum/Soil roadby chiseling for preparing pit for poles stay or earthplatesorforlayingcables,pipes& clearingthesitebyremovingdebris& making the site good complete. CSR 22-23 (16-1-7 ) |
| 630 | Supplying and erecting 100millimetre diameterpressure gauge , 0-300 PSI or 0-14 kg per centimetresquare fitted with 12/15millimetre diameterpad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG CSR 22-23 (13-8-14) |
| 631 | Supplyingandinstallingpressureswitch with12/15 millimetre diaisolationvalve,G.I. nipple,elbow,etccompleteasper specification no. FF-FFA/PS CSR 22-23 (13-8-15) |
| 632 | Supplyinganderectingcastirondouble flange NRV ofsize 200millimetre dia completewith PN16 pressure rating, asper specification no. FF-VL/NRV (CSR 22-23)-13-7-26 |
| 633 | Supplyinganderectingcastirondouble flange NRV ofsize 150millimetre diacompletewith PN16 pressure rating, asper specification no. FF-VL/NRV(CSR 22-23)-13-7-25 |
| 634 | Supplyinganderectingcastirondouble flange NRV ofsize 100millimetre dia completewith PN16 pressure rating, asper specification no. FF-VL/NRV (CSR 22-23)-13-7-24 |
| 635 | Supplyinganderectingcastirondouble flangeNRVofsize80 millimetre diacompletewith PN16 pressure rating, asper specification no. FF-VL/NRV (CSR 22-23)-13-7-23 |
| 636 | Supplying and erecting 150millimetre diametercast iron double flange butterfly valve ofsize complete with PN16 pressure rating, asper specification no. FF-VL/BFV (CSR 22-23)-13-7-21 |
| 637 | Supplying and erecting 100millimetre diametercast iron double flange butterfly valve ofsize complete with PN16 pressure rating, asper specification no. FF-VL/BFV (CSR 22-23)-13-7-20 |
| 638 | Supplying and erecting 65millimetre diametercast iron double flange butterfly valve ofsize complete with PN16 pressure rating, asper specification no. FF-VL/BFV (CSR 22-23)-13-7-18 |
| 639 | Supplying and erecting 50millimetre diametercast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)-13-7-17 |
| 640 | Supplying and erecting 200millimetre diametercast iron double flange sluice valvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV (CSR 22-23)-13-7-16 |
| 641 | Supplying and erecting 150millimetre diametercast iron double flange sluice valvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV (CSR 22-23)-13-7-15 |
| 642 | Supplying and erecting 80millimetre diametercast iron double flange sluice valvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV (CSR 22-23)-13-7-14 |
| 643 | Supplying and erecting 150millimetredia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS(CSR 22-23)-13-7-7 |
| 644 | Supplying and erecting 100millimetredia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS(CSR 22-23)-13-7-6 |
| 645 | Supplying and erecting 75/80millimetredia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS(CSR 22-23)-13-7-5 |
| 646 | Supplying and erecting stainless steel Double outlet hydrant valve fitted with necessaryaccessoriescompleteasper specification no. FF-VL/HV (CSR 22-23)-13-7-37 |
| 647 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessaryaccessoriescompleteasper specification no. FF-VL/HV (CSR 22-23)-13-7-35 |
| 648 | SupplyingSSBranchPipesof63 millimetre diameterfitted with 20millimetredia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NZ (CSR 22-23)-13-8-8 |
| 649 | Supplyingfirefightingreinforcedrubber lined(R.R.L.)hosepipe,63 millimetre dia, 15m in length,fitted with necessary accessories complete as per specification no. FF-FFA/RRL (CSR 22-23)-13-8-4 |
| 650 | Supplying and installing wall mounted swingingHoseReelDrumfittedwith19millimetre dia30mtrlonghighpressure polypropylene(polyhose)pipefittedwith necessaryaccessoriescompleteasper specification no. FF-FFA/HRD (CSR 22-23)-13-8-2 |
| 651 | Supplying and erecting M.S./CRCA cabinetforhousingHydrantvalve,hose pipeandbranchpipe(size1000x736x 736 millimetre .) made from16SWG sheetand angleiron25 millimetre .x25 millimetre .x4 millimetre . having front doors with viewing glass (8\" x 6\") and locking arrangement with necessaryfixingmaterialsuchasrubber biddingetc.dulypaintedinpostboxred colour. (CSR 22-23)-13-8-20 |
| 652 | Supplying and erecting 25millimetredia GM Air Release Cock with necessary GI coupling tobe fittedontopofair vesseloronwet riser as per specification FF-FFA/ARV. (CSR 22-23)-13-8-13 |
| 653 | Supplying and erecting 300millimetredia 1.5m in height air vessel / tankfabricated from min 5 millimetrethick M.S. sheet complete as per specification no. FF-FFA/ACT. (CSR 22-23)-13-8-12 |
| 654 | Supplying and erecting one no. Brass orificeplatehaving6 millimetre thickness,160millimetreouter dia at every single outlet hydrant valve as per specification No. FF- FFA/OP(CSR 22-23)-13-8-17 |
| 655 | Supplying and erecting 25millimetredia gun metal gate valve complete withPN16 pressure rating, asper specification no. FF-VL/GV(CSR 22-23)-13-7-32 |
| 656 | Supplyinganderecting15 millimetre (½\") diameterNB centimetre Bodychromefinished(pendent/ Uprighttype)quartzoidbulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR (CSR 22-23)-13-12-1 |
| 657 | Providing,fixing,testing &commissioningof 15 millimetredia quartzoid bulb type sprinkler of rating 68 deg.centigrade with required accessories Horizontal side wall sprinkler (CPWD DSR 2022)-18.21.3 |
| 658 | Sprinkler flexibledrops stainless steel complete with 15NPT on reducer thread with maximum working pressure of 175 PSI test pressureof 875 PSI(Burst) withbranchline(Inlet) 25 millimetre NPT male thread to sprinkler head (Outlet) 15 millimetre NPT female thread with reducer,nipple, 2 side brackets,center bracket,stockbar of following sizes complete as required.1500millimetre -(CPWD DSR 2022)-18.25.4 |
| 659 | Providing, installation, testing &commissioningof adjustable rosette plate for 15 millimetredia in white finish UL Listed or FM approved complete as required.(CPWD DSR 2022)-18.29 |
| 660 | Providing, installation, testing &commissioningof water curtain nozzle 15 millimetredia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.(CPWD DSR 2022)-18.27 |
| 661 | supplying,installation,testing &commissioningof deluge valve (to be used for water curtains) UL Isted With wel Pies vate with assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. 100millimetredia (CPWD DSR 2022)-18.26.3 |
| 662 | Providing, installation, testing &commissioningof electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required(CPWD DSR 2022)-18.28 |
| 663 | Making cement concrete foundation in 1:2:4 cement concrete with foundationbolts and nuts complete. (cost of wooden box is included) (for pumps).(CSR 22-23)-16-3-5 |
| 664 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq.millimetre . copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU CSR 22-23 ( 7-2-16) |
| 665 | Supplying, installing, testing andcommissioningFR, XLPE armoured cable 2 core 1.5 sq. millimetre . copper conductor complete erected on wall/ ceiling complete asper specification no. CB-LT/CU CSR 22-23 (13-9-10 ) |
| 666 | Supplying, installing, testing andcommissioningFR, XLPE armoured cable12 core 1.5 sq. millimetre . copper conductor complete erected on wall/ ceilingcomplete asper specification no.CB-LT/CU CSR 22-23 ( 13-9-13) |
| 667 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 70 sq.millimetre . aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL CSR 22-23 (7-1-18) |
| 668 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 10 sq.millimetre . copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CUCSR 22-23 (7-2-17) |
| 669 | Providing, fixing, testing &commissioningof installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riserisprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 150 millimetredia(CPWD DSR 2022)-18.24.3 |
| 670 | Supplying, erecting, testing andcommissioningvane type water flow detector 100millimetre diameterwith 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipesCSR22-23( 3-12-3) |
| 671 | Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings ofall kinds of cables, pipes and cable support system in steel, aluminium and plasticprofiles ( except hollow core conductors). The residual openings shall be closedwith filler, as per specification no FF-FRM.CSR 22-23 (13-13-1) |
| 672 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. CSR 22-23(6-1-19) |
| 673 | Supply, Installation, Testing &commissioningof Intelligent Addressable type multisensor detector with base, withMicroprocessor inbuilt, for use as heat (Fixed + Rate of Rise or individual ) or smoke or combined both with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 42 /IP 44 or better protection catagory & ambient temperature -20⁰C to + 60⁰C, the base shal have no electronics only dry contact terminals.The quoted item shall completely comply to the technical specification.Shall be Vds approvedaccording toEN 54-5, 54-7, 54-17, 54-29or UL& FM approved as per Latest standards |
| 674 | Supply, Installation, Testing &commissioningof Intelligent Addressable type optical smoke detector with base, withMicroprocessor inbuilt with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 42 / IP 44 or better protection catagory & ambient temperature -20⁰C to + 60⁰C, the base shal have no electronics only dry contact terminals.The quoted item shall completely comply to the technical specification.Shall be Vds approvedaccording toEN 54-5, 54-7, 54-17, 54-29 or UL& FM approved as per Latest standards |
| 675 | Supply, Installation, Testing &commissioningof Intelligent Addressable type thermal/heatdetectorwith rateofriseOne Cubic Metre fixedtemperature thermistorwith base, withMicroprocessor inbuilt with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 44 protection catagory & ambient temperature -20⁰C to + 60⁰C, the base shal have no electronics only dry contact terminals.The quoted item shall completely comply to the technical specification.Shall be Vds approvedaccording toEN 54-5, 54-7, 54-17, 54-29 or UL& FM approved as per Latest standards |
| 676 | Supply, Installation, Testing &commissioningofAddressable manual call point which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. This must have inbuilt short circuit isolator,. The ambient temperature range shall be -20⁰C to +50⁰C.The quoted item shall completely comply to the technical specification.shallbe Vds approved or UL& FM approved as per Latest standards |
| 677 | Supply, Installation, Testing &commissioningof Addressable Loop Powered multi tone sounder with integrated short circuit isolator(in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each loop powered sounder) & having operating temperature -10⁰C to + 55⁰C, Volume 89 dB (99 dB) ±3 dB(A)/m at 24 V DC, IP 21 andshallbe Vds approved |
| 678 | Supply, Installation, Testing &commissioningof Addressable loop powered flashing light for visual notification of a fire alarm in interior areas, should have inbuilt fault isolator. The operating Temprature should be -10⁰C to + 55⁰C, Luminous intensity: approx. 1 cd, IP 21 andshallbe Vds approved or UL& FM approved as per Latest standards |
| 679 | Supply, Installation, Testing &commissioningof Active Repeater Panel including a case, membrane keypad, minimum 800 character LCD display with 10 configurable soft buttons and 10 configurable LED\"s. Repeater panel shall not require separate power supply & battery. Vds approved Panel or UL& FM approved as per Latest standards |
| 680 | Supply, Installation , Testing &commissioningof Linear Smoke detector consists of a transmitterreceiver and reflector which are mounted opposite each other at a distance of between 5 and 120 m.The module must be VDS approved or UL& FM approved as per Latest standards |
| 681 | Supply, Installation , Testing &commissioning of Vds approved Analogue Addressable Input / Output modulewith IP66 casingfor conventional beam detector with in-built short citcuit isolator(in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each monitor module), it must be VdS approved and as per EN-54 standard. The ambient temperature range shall be -20⁰C to +60⁰C.The quoted item shall completely comply to the technical specification. |
| 682 | Supply, Installation, Testing &commissioning of32-bit dual core microprocessor basedFail Safe Intelligent Addressable Fire Alarm Control panelwith 12 loop with inbuilt Bluetooth. The FACP should have Capacity of Peer to Peer Networking of Panels,The control panel shall be Vds approved and as per EN-54 standard or UL& FM approved as per Latest standards. The panel should be modular, decentralized, with redundancy in cpu/master control unit, fail safe in loop cards, relay and interface card by means of duplicated electronics . The panel shall consisting with minimum 800 character LCD display with 10 configurable soft buttons and 10 configurable LED\"s.Panel should be able to record atleast minimum 15000 events history or more. Each loop should be capable to have atleast 250 elements / devices out of which min. 200 nos. shall be detectors. The Panel Shall have on board TCP/IP Lan port to facilate remote operation of the panel.The system should be Vds approved It is possible tocommissioningthe System through LAN Network. |
| 683 | Supply, Installation , Testing &commissioning of Vds approved or UL& FM approved as per Latest standardsAnalogue AddressableOutput modulewith IP66 casingcontaining one Relay Output with in-built short circuit isolator(in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each monitor module), it must be VdS approved and as per EN-54 standard. The ambient temperature range shall be -20⁰C to +60⁰C.The quoted item shall completely comply to the technical specification. |
| 684 | Supply, Installation , Testing &commissioning of Vds approved or UL& FM approved as per Latest standardsAnalogue Addressable Input Modulewith IP66 casingcontaining 1 inputs for monitored quering of potential free contactswith in-built short circuit isolator(in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each monitor module), it must be VdS approved and as per EN-54 standard. The ambient temperature range shall be -20⁰C to +60⁰C.The quoted item shall completely comply to the technical specification. |
| 685 | Supplying, installing, testing andcommissioning FR, XLPE armoured cable2 core 1.5sq. millimetre .copper conductor complete erected on wall/ ceilingcompleteas perspecificationno. CB-LT/CU CSR 22-23 ( 13-9-10 ) |
| 686 | Supplying, installing, testing andcommissioningremote response indicators suitable to operate on 5- 28 V dc supply having FR Polymer ABS Housing complete asper specification no. FF-FAAS/RRI CSR 22-23 (13-9-9 ) |
| 687 | Supplying, installation, testing &commissioningof fire fighter telephone handset complete as required. (CPWD DSR 2022)-17.2.17 |
| 688 | Supplying, installation, testing &commissioningof intelligent interface unit BACnet/ Modbus protocol I.e. supplying co millimetre unication links between building management system and fire alarm control panel complete as required. (CPWD DSR 2022)-17.2.18 |
| 689 | Supplying, installation, testing &commissioningof fire fighter phone jack complete as required. (CPWD DSR 2022)-17.2.19 |
| 690 | Design, supply, installation, testing andcommissioningof Windows based Central Monitoring & Control Software with 8 Licenses and expandable to 32, shall be capable to perform paging and message playing to all zones of devices over LAN. Unicast/multicast, Routing, Message Playing, Scheduler, Text to speech and volume control, shall be capable to monitor all the system components, Monitoring device status such as Offline/online or line-occupied/line available to Support TCP, UDP, SIP, RTP and IGMP protocol. The Server shall have user friendly to configuration and flexibility in button design. inclusive of required software & license. |
| 691 | Supply, installation, testing andcommissioningof Intel Core i5 Quad Core @ 3.3 GHz or Latest, 16GB dual channel DDR3 1333/1600,Graphics NVIDIA (2 GB dedicated) With DVI/HMI output with2TB 7.5K rpm SATA hard disk,PS/2/ USB Compatible, Dual Gigabit Ethernet,power supply provisions Cost should be With Life time license for Windows 8 enterprise/professional or latest software compatibleMacAfee /Symantec Anti virus, with 24 Inch LED Display Monitor & All other related software such MS office with liscesenced.The required operation & PA software etc. & Workstation should be FCC & UL listed. |
| 692 | Supply, Installation, Testing &commissioning of controller unit whichis progra millimetre able with the software on each specific system configuration, with automatic and permanent monitoring of the system controller and the system components according to EN 50849, BS5839, NEN2575 and EN54-16. Progra millimetre able over network interface with code protected access to the processing unit and other components in the system. (modules , amplifiers and paging stations).It should have following features• Monitored according to standard EN 54-16• 4 Channel Audio Player• 8 progra millimetre able buttons / LEDs• DSP for all analog and digital inputs / outputs• 2 MC LINK inputs for serial microphone consoles• 4 analog inputs -60 to 0 dBu• 2 analog outputs 0 dBu• 8 digtial monitored inputs• 4 digital potential-free change-over contacts• APS network functions(optional software package )• Web server for operating and display units(optional software package)• Embedded hardware firewall to separateVA and PA functions• Various interfaces (optional software package)for connection to control centres and buildingmanagement systems |
| 693 | Supply, installation, testing andcommissioningofDigital Zone monitoring controller according to EN 54-16It should contain line monitoring with DSP technology for uninterrupted, permanent (even with music mode) automatic monitoring of up to 32 speaker zones for short circuit, open circuit, short to ground and impedance change, by means of High-precision error detection with DSP technology by load measurement, measurement of the phase shift between current and voltage.LED indication on front-side per speaker line. It should have rotary knob and Integrated LCD display for menu-guided operation Like-deactivation of zones, Lists detailed error analysis , Automatic calibration of each individual zone,Individual adjustment of the measuring tolerance for each individual zone .Further it must havefeatures:- Fault memory in an error list in accordance with EN 54-16- Automatic isolation of the defective speaker line in short-circuit- Recognition of the re- functioning speaker line without a device reset- Permanent monitoring of each line without additional modules (eg end-of -line)- No interruption of the line for voice announcements or background music with high-quality DSP technology.CE Conformity: EN 54-16 Electromagnetic. I millimetre unity: to EN 55024 / EN 301 489 Emission standard: according to EN 55022 / EN 300220-1 |
| 694 | Supply, installation, testing andcommissioningofDigital, progra millimetre able microphone console, monitoredMicroprocessor -controlled digital microphone console for information and call announcements, a manual triggering of alarm signals and the stored emergency announcements, as well as for the selection of speaker lines and groups. Suitable for connection of up to 30 other digital microphone consoles, with permanent monitoring of the microphone capsule and the processor according to EN 54-16. Dynamic gooseneck microphone with acoustic monitoring of the microphone capsule by test frequency.24 freely progra millimetre able keys with LED indicator lights in 2 levels. A built-in buzzer provides for signalling of fault message conditions. |
| 695 | Supply, installation, testing andcommissioningofDigital Class-D power amplifier 500 watts, 100 voltsDigital, fully monitored, convection cooled power amplifier, with a continuous power of 100 watts especially according to EN 54-16. It should have a micro-controller including digital disaster management and emergency charging electronics for standards-compliant, optional redundant supply of emergency battery power unit. It should also have progra millimetre able 5 x 4 matrix, the 4 internal and the external digital, analog AF - bus can be set system-specific in the software on each amplifier channel. It should have protection circuits against overload, short circuit, open circuit, overvoltage, power failure, battery failure, data co millimetre unications failure, thermal overload. Also, it should be activatable as a standby mode.Features:Electronically balanced audio input via XLR jacksOutput power: 100W (Maximum) : 100W RMSControlling: MicroprocessorPower supply: 230 VAC + / - 10 %Frequency response: 50 Hz to 20 kHz (-3 dB)Emergency power supply: 48 VDCSignal to noise ratio:> 94 dBCE Conformity: EN 54 -16: 2008Electromagnetic. I millimetre unity: to EN 55024 / EN 301 489Emission standard: according to EN 55022 / EN 300220-1 |
| 696 | Supply, installation, testing andcommissioningofDigital Class-D power amplifier 4 x 250 watts, 100 voltsDigital, fully monitored, convection cooled power amplifier, with a continuous power of 4 x 250 watts especially according to EN 54-16. It should have a micro-controller including digital disaster management and emergency charging electronics for standards-compliant, optional redundant supply of emergency battery power unit. It should also have progra millimetre able 6 x 4 matrix, the 4 internal and the 2 external digital, analog AF - bus can be set system-specific in the software on each amplifier channel. It should have protection circuits against overload, short circuit, open circuit, overvoltage, power failure, battery failure, data co millimetre unications failure, thermal overload. Also, it should be activatable as a standby modeFeatures:4 Electronically balanced audio input via XLR jacksOutput power: 4 x 250W (Maximum) : 4 x 200W RMSControlling: DSP MicroprocessorPower supply: 230 VAC + / - 10 %Frequency response: 50 Hz to 20 kHz (-3 dB)Emergency power supply: 48 VDCSignal to noise ratio:> 94 dBCE Conformity: EN 54 -16: 2008Electromagnetic. I millimetre unity: to EN 55024 / EN 301 489Emission standard: according to EN 55022 / EN 300220-1 |
| 697 | Supply, installation, testing andcommissioningofDigital Class-D power amplifier 2 x 250 watts, 100 voltsDigital, fully monitored, convection cooled power amplifier, with a continuous power of 2 x 250 watts especially according to EN 54-16. It should have a micro-controller including digital disaster management and emergency charging electronics for standards-compliant, optional redundant supply of emergency battery power unit. It should also have progra millimetre able 6 x 4 matrix, the 4 internal and the external digital, analog AF - bus can be set system-specific in the software on each amplifier channel. It should have protection circuits against overload, short circuit, open circuit, overvoltage, power failure, battery failure, data co millimetre unications failure, thermal overload. Also, it should be activatable as a standby modeFeatures:2 Electronically balanced audio input via XLR jacksOutput power: 2 x 250W RMS : 2 x 200W RMSControlling: MicroprocessorPower supply: 230 VAC + / - 10 %Frequency response: 50 Hz to 20 kHz (-3 dB)Emergency power supply: 48 VDCSignal to noise ratio:> 94 dBCE Conformity: EN 54 -16: 2008Electromagnetic. I millimetre unity: to EN 55024 / EN 301 489Emission standard: according to EN 55022 / EN 300220-1 |
| 698 | Supply, installation, testing andcommissioningofEN 54-24 certified 6W rectangular wall mounted speaker with maximum SPL of 103 db @6W/1m and magnet 10\"500 Gs. It must have sensitivity of Sensitivity (1 W/ 1 m) 95.7 dB. The speaker should have 1.5W/ 3W/ 6W tapping.It should be of EV-Version with ceramic terminal and thermal fuse and with IP 44 protection. The speaker must be with metal enclosure. |
| 699 | Supply, installation, testing andcommissioningofEN 54-24 certified 6W Ceiling speaker with maximum SPL of 101.6 db @6W/1m and magnet 4000 Gs. It must have sensitivity of Sensitivity (1 W/ 1 m) 93.8 dB. The speaker should have 1.5W/3W/6W tapping. It should be of EV-Version with ceramic terminal and thermal fuse and with IP 44 protection. The speaker must be with metal dome. |
| 700 | Supply, installation, testing andcommissioningof EN 54-24 certified 20W Horn 360 degspeaker with maximum SPL of 118.8 db @20W/1m. It must have sensitivity of Sensitivity (1 W/ 1 m) 105.8 dB. The speaker should have2.5W / 5W / 10W / 20W tapping.It should be ofEV-Version with IP 65 protection. The speaker must be with metalenclosure canopy. |
| 701 | Supply, installation, testing andcommissioningof40W Horn 360 degspeaker with maximum SPL of 128.5 db @40W/1m. It must have sensitivity of Sensitivity (1 W/ 1 m) 112.5 dB. The speaker should have5W / 10W / 20W / 30W / 40W tapping.It should be of IP 66 protection. |
| 702 | Supply, installation, testing andcommissioningof EN 54-24 certified 15W 2 way Ceiling speaker with maximum SPL of 106 db @15W/1m. It must have sensitivity of Sensitivity (1 W/ 1 m) 94.5 dB.It should be of EV-Version with ceramic terminal and thermal fuse and with IP 44 protection. The speaker must be with metal dome. |
| 703 | Supply, installation, testing andcommissioningofEN 54-24 certified 12 W double sided design Sound projector speaker with maximum SPL of 88 db @1xW/1m. It must have sensitivity of (1 W/ 4 m) 76 dB. The speaker should have 12 / 6 / 3 W tapping.It should be ofEV-Version with ceramic terminal and thermal fuse and with IP 65 protection. The speaker must be with metelenclosure. |
| 704 | Supply, Installation, Testing &commissioningof modular type 36W volume control units with override mechanism suitable including front plate and anodised GI box in concealed manner of adequate sizes, including all fixing accessories. |
| 705 | Supply & fixing of Relay contact with standard connectivity accessories & hardware |
| 706 | Supply & fixing of warning light with relay contactor |
| 707 | Supply and wiring of 2C - 1 sq.millimetre . FRLS insulated twisted pair multistranded copper conductor armoured cable in existingPoly vinyl chloride / GI conduit or direct on ceiling surface with clamp, complete as required. |
| 708 | Supply and wiring of 4C - 1.5 sq.millimetre . FRLS insulated multistranded copper conductor armoured cable in existingPoly vinyl chloride / GI conduit or direct on ceiling surface with clamp, complete as required. |
| 709 | Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070 millimetre ) as perspecification No. WG-NAS/RAK |
| 710 | LIFT WORK |
| 711 | SITC of Electric Traction Passenger One Cubic MetreStretcher/HospitalLiftwith Rated capacity :- 20 Passenger/1360Kg Floors :- B+ G+12 floor (14 Stops/14 Landings) Travel :- 55mtrs Appx. Location of Lift Machine:- MR/MRL Rated speed :- 1.5mps VSCar/Landing door clear opening of 1200millimetrewide x 2000millimetre Clear Carsize of1300millimetrewide x 2600millimetredeep x2250 millimetrehighLift shaft available having clear size of 2400millimetrewide x 3000millimetredeep,1600millimetrePit depth,4800millimetreOverhead. |
| 712 | Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5 millimetrethick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5 millimetre , thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, |
| 713 | Lift car arrival & nexttravel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5 millimetreCRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. |
| 714 | Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of2350millimetrewide x 3000millimetredeep, 1600millimetrePit depth, aprox.4500millimetreOverhead. (Lifts with Triplex Control)Notes:-1. General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.2. Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.Amount as given in maintenance schedule will be deducted and kept aside as Security deposit for 3 years AMC period. |
| 715 | SITC of Electric Traction Passenger One Cubic MetreStretcher/HospitalLiftwith Rated capacity :- 20 Passenger/1360Kg Floors :-G+12 floor (13 Stops/13 Landings) Travel :- 50mtrs Appx. Location of Lift Machine:- MR/MRL Rated speed :- 1.5mps VSCar/Landing door clear opening of 1200millimetrewide x 2000millimetre Clear Carsize of1300millimetrewide x 2600millimetredeep x2250 millimetrehighLift shaft available having clear size of 2400millimetrewide x 3000millimetredeep,1600millimetrePit depth,4800millimetreOverhead.Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5 millimetrethick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5 millimetre , thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, |
| 716 | Lift car arrival & nexttravel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5 millimetreCRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. |
| 717 | Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of2350millimetrewide x 3000millimetredeep, 1600millimetrePit depth, aprox.4500millimetreOverhead. (Lifts with Triplex Control)Notes:-1. General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.2. Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.Amount as given in maintenance schedule will be deducted and kept aside as Security deposit for 3 years AMC period. |
| 718 | SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with progra millimetre ing and hardware e.g. logic board, necessary co millimetre unication/control/data cabling laying in rigidPoly vinyl chlorideconduits/trunking etc. complete. |
| 719 | SITC of Triplex Lift control system for three nos. microprocessor/PLC based simplex lift controllers along with necessary software with progra millimetre ing and hardware e.g. logic board, necessary co millimetre unication/control/data cabling laying in rigidPoly vinyl chlorideconduits/trunking etc. complete. |
| 720 | HVACSYSTEM |
| 721 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 400 millimetre diameter(75millimetrethick insulation) |
| 722 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 350 millimetre diameter(75millimetrethick insulation) |
| 723 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 300 millimetre diameter(75millimetrethick insulation) |
| 724 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 250 millimetre diameter(75millimetrethick insulation) |
| 725 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 200 millimetre diameter(75millimetrethick insulation) |
| 726 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 150 millimetre diameter(75millimetrethick insulation) |
| 727 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 125 millimetre diameter(50millimetrethick insulation) |
| 728 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 100millimetre diameter(50millimetrethick insulation) |
| 729 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 80millimetre diameter(50millimetrethick insulation) |
| 730 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 65millimetre diameter(50millimetrethick insulation) |
| 731 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above.50millimetre diameter (50millimetrethick insulation) |
| 732 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above 40millimetre diameter(50millimetrethick insulation) |
| 733 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above.32millimetre diameter (50millimetrethick insulation) |
| 734 | Supplying, laying/ fixing, testing andcommissioningof following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/One Cubic Metreafter a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 millimetrealuminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 millimetre& below shall be M.S. \"C\" class as per IS : 1239 and pipes size above 150 millimetreshall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 millimetrethick M.S. Sheet for pipes upto 350millimetre diameterand from minimum 7 millimetrethick MS sheet for pipes of 400millimetredia and above. 25millimetre diameter (50millimetrethick insulation) |
| 735 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.150millimetreDia |
| 736 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.125millimetreDia |
| 737 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.100millimetreDia |
| 738 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.80millimetreDia |
| 739 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.65millimetreDia |
| 740 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.50millimetreDia |
| 741 | Supply,fixing,testing andcommissioningof butterfly valve(manual) with CIbody SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified.40millimetreDia |
| 742 | Supply,fixing,testing andcommissioningofY- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified.80millimetreDia |
| 743 | Supply,fixing,testing andcommissioningofY- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified.65millimetreDia |
| 744 | Supply,fixing,testing andcommissioningofY- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified.50millimetreDia |
| 745 | Supply,fixing,testing andcommissioningofY- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified.40millimetreDia |
| 746 | Supplying and erecting GI pipe 50 millimetre diameter‘B’ class at position withaccessories complete as per specification no. CW-PLB/GP. |
| 747 | Supplying and erecting GI pipe 40millimetre diameter‘B’ class at position withaccessories complete as per specification no. CW-PLB/GP. |
| 748 | Supplying and erecting GI pipe 32millimetre diameter‘B’ class at position withaccessories complete as per specification no. CW-PLB/GP. |
| 749 | Supplying and erecting GI pipe 25millimetrediameter‘B’ class at position withaccessories complete as per specification no. CW-PLB/GP. |
| 750 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9millimetrethickness and inner diameter / sizes 28millimetrefor solar water heater/AC system. |
| 751 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9millimetrethickness and inner diameter / sizes 42millimetrefor solar water heater/AC system. |
| 752 | Supply, Installation, Testing andcommissioningof following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50millimetrevalves and 7 Bar for 65millimetre& above. Valves should have pressure rating of 25 Bar minimum.80millimetreDia |
| 753 | Supply, Installation, Testing andcommissioningof following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50millimetrevalves and 7 Bar for 65millimetre& above. Valves should have pressure rating of 25 Bar minimum.65millimetreDia |
| 754 | Supply, Installation, Testing andcommissioningof following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50millimetrevalves and 7 Bar for 65millimetre& above. Valves should have pressure rating of 25 Bar minimum. 50millimetreDia |
| 755 | Supply, Installation, Testing andcommissioningof following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50millimetrevalves and 7 Bar for 65millimetre& above. Valves should have pressure rating of 25 Bar minimum. 40millimetreDia |
| 756 | Supply, Installation, Testing andcommissioningof following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50millimetrevalves and 7 Bar for 65millimetre& above. Valves should have pressure rating of 25 Bar minimum.32millimetreDia |
| 757 | Supplying and erecting GI sheet 0.6millimetre(24 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 758 | Supplying and erecting GI sheet 0.8millimetre(22 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 759 | Supplying and erecting GI sheet 1millimetre(20 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 760 | Supplying and erecting GI sheet 1.25millimetre(18 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 761 | Supply,installation ,testing andcommissioningof GI volume control duct damper complete with neoprene rubber gaskets,nuts,bolts, screw linkages,flanges etc as per specifications |
| 762 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control Dampers as per specifications |
| 763 | Supplying & fixing of powder coats extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.( |
| 764 | Supplying, fixing testingcommissioningof supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 765 | Supplying, fixing testingcommissioningof Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 766 | Providing adhesive thermal insulation for supply return air duct with 19 millimetrenitrile rubber insulation having R-value as per the prevailing provisions in ECBC2017. |
| 767 | Providing and applying of acoustic insulation for air ducts with 25 millimetrethick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete. |
| 768 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 769 | CCTVAND LAN SYSTEM |
| 770 | Supply,installation, testing &commissioningof IP Fixed Dome camera (Indoor) with 1/2.8\" CCD/ centimetre OS, 5MP, 3.5-10millimetremotorized varifocal, P/DC- Iris lens Progressive/De-interlace, High Definition resolution (2592 x 1944), min. Quad streaming, Shutter speed - 1/1,00,000/sec, First & Second Stream should be 30 FPS @ 1920X1080, H.264/H.265 & JMPEG compression support, 0.1 lux @ Built-in IR illuminators, effective up to 30 meters, Motion detection, Tamper detection,3D DNR, Wide dynamic Range, PoE power input, 40 Mtr IR AWB, AGC, BLC, 1/1 Alarm in/out, 1/1 audio in/out, Should have a compulsory Reset button audio -In & Out Port, RJ 45 Port, SD card 256 GB, 40 Mtr IR Range, Metal Body, Support ONVIF(S,G,T), PoE, CE, FCC ,IP67, NDAA, NEMA-4X, STQCcertified. No GB/T 28181, Cybersecurity certification required (NDAA/UL/GDPR/NIST/TPM/ISO 27032/Indian Govt.). All Required Mounting Accessories and Hardware should be included. |
| 771 | Supply,installation, testing &commissioning of Outdoor IP Bullet camera with 1/2.8\"centimetre OS or better, Progressive Scan, 5MP, Day/Night,3.5 to 10millimetremotorised zoom lens with Autofocus,Remote Focus,Shutter speed - 1/1,00,000/sec, Support H.264/H.265 & MJPEG, First & Secound Stream should be 30 FPS @ 2592X1944, Quad streaming, Motion detection, video tampering, Tamper detection, Digital WDR 120 dB, Day/ Night (ICR), 3D DNR, AWB, AGC, BLC, 1/1 Alarm in/out, 1/1 audio in/out, Should have a compulsory Reset button audio -In & Out Port, RJ 45 Port, 60 Mtr IR Range,SD card 256 GB, Support ONVIF, IP67,IK10,PoE, CE, FCC, NDAA, NEMA-4X, STQC certified. No GB/T 28181, Cybersecurity certification required (NDAA/UL/GDPR/NIST/TPM/ISO 27032/Indian Govt.). All Required Mouting Accessories and Hardware should be incluided. |
| 772 | Supply, installation, testing &commissioningof Outdoor PTZ IP Camera of 4K, 8 MP PTZ DOME STARLIGHT CAMERA; vandal-proof IP66; integral 1/1.8\" day/night camera with 6.5-230millimetre35X zoom lens; 1312 ft (400 m) Range, IR; speed dry; 71 W max, requires 90 W power injector; NDAA/GSA/TAA/HTQC compliant. All Required Mounting Accessories and Hardware should be included. |
| 773 | Supply,installation, testing &commissioning of Outdoor PTZ IP Camera of 5 MP PTZ DOME STARLIGHT CAMERA; vandal-proof IP66; integral 1/2.8\" day/night camera with 4.25-170millimetre40X zoom lens; up to 250m Range IR; speed dry; 71 W max, requires 90 W power injector (VPOE-INJ-90BT-A/equivalent); NDAA/GSA/TAA compliant. All Required Mouting Accessories and Hardware should be incluided. |
| 774 | Supply,installation, testing &commissioning of WALL MOUNT; medium; for use with Roughneck multi-sensor, domes and PTZ cameras. All Required Mouting Accessories and Hardware should be incluided. |
| 775 | Supply,installation, testing &commissioning of Controller, IP system keyboardwith LED Display to control PTZ. It should be as per Technical Specification. |
| 776 | Supply,installation, testing &commissioning of 64 Channel Network Video Recorder (NVR) with neccessary monitoring software - 19\" rack mounted, Network Video Recorder 64 Channel Connect Up to 64 IP Cameras,HDMI1/ VGA1 and HDMI2/ VGA2 outputs provided, NVR Supports two HDMI port one with 4K resolution and other with 1920x1080p, atleast one VGA output with output upto 1920 × 1080, Support H.265, H.264, MJPEG, Supports RAID0/ RAID1/ RAID5/ RAID6 , Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces and capacity of each HDD upto 8TB, RS-232; RS-485, Alarm I/O 16/4, atleast 2 RJ-45 10 /100 MbpsEthernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. All Required Mouting Accessories and Hardware should be incluided. |
| 777 | Supply,installation, testing &commissioning of 10TB SURVELLAINCE Hard Disk (Minimum 30 days with 25/30 FPS, recording- motion Based, H.265 Compression Technique) |
| 778 | Supply,installation, testing &commissioning of Application server for VMS: 1U Server / Tower, Processor: Intel Xeon E-2400 series processor with up to 8 cores, RAM: 32 GB DDR5 RAM, OS Storage: OS DRIVE: 2X 480GB M.2 SSD/NVMe BOSS (RAID 1), Network Port: 2 x 1GbE RJ45, Power Supply: Dual, hot-swappable, redundant power supply units (PSUs)., OS: Microsoft Windows 11 loT LTSC, HDD: 6Gbps SATA 7200RPM 3.5in, Storage: 50 TB Usable. All Required Mouting Accessories and Hardware should be incluided. |
| 779 | Supply,installation, testing &commissioning of Remote Viewing Workstation for CCTV : Intel i7 Processor, min 32 GB high speed DDR 4 RAM, 1TB SSD,4TB HDD Pre Loaded with Windows 11 or Higher OS as per OEM recomendation, Firewall and Antivirus, DVD RQ and with Additional Graphics Card with 8GB Video RAM and Dual Monitor Display Output on HDMI/ VGA Interface, with PC Speakers, wireless mouse & keyboard etc.& Workstation shall operate for 24x7 operation. All Required Mouting Accessories and Hardware should be incluided. |
| 780 | Supply,installation, testing &commissioning ofMain Viewing Screens for above mentioned Remote Viewing Work station large wall mount LED screens, no less than 50\"\" with HDMI, PC inputs. Screen should be suitable for 24X 7 operation.It shall come with remote control and shall have various picture mode options for data representation with all necessary Fixing accessiories for viewing, The Monitor should be FCC & UL listed All Required Mouting Accessories and Hardware should be incluided. |
| 781 | Supply,installation, testing &commissioning of Video Management software system& required no. of Channel License per camera. STQC certified, ONVIF S,G,T. |
| 782 | Supply,installation, testing &commissioning ofadjustable wall Mounting MS stands for outdoor cameras,made out of 5 millimetrethick, 80 millimetredia pipe with zinc chromite primer & powder coating of suitable shade. All Required Mouting Accessories and Hardware should be incluided. |
| 783 | Supply,installation, testing &commissioning ofWeather Proof Junction Box for Camera End with required all Mouting Accessories and Hardware etc. All Required Mouting Accessories and Hardware should be incluided. |
| 784 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 785 | Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 786 | Supplying and erectingPoly vinyl chlorideSurface modular switch box with double mounting plate for 1 module complete duly erected along with 1 no of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO (Item no.1-6-26 Rs.124.00 + 1-12-2 Rs.506.00 = Rs.630.00) |
| 787 | Supplying and erectingPoly vinyl chlorideSurface modular switch box with double mounting plate for 2 module complete duly erectedalong with 2 no of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO (Item no.1-6-27 Rs.128.00 + 1-12-2 Rs.506.00 x 2 nos = Rs.1140.00) |
| 788 | Supplying and erectingPoly vinyl chlorideSurface modular switch box with double mounting plate for 4 module complete duly erectedalong with 4 nos of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO) (Item no.1-6-29 Rs.172.00 + 1-14-2 Rs.448.00 x 3 nos = Rs.1748.00) |
| 789 | Supplying and erectingPoly vinyl chlorideSurface modular switch box with double mounting plate for 4 module complete duly erectedalong with 4 nos of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO) (Item no.1-6-29 Rs.172.00 + 1-14-2 Rs.448.00 x 4 nos = Rs.2196.00) |
| 790 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 791 | Supplying and fixing Cat-6 24 port Patch panel with Tool-less keystone jacks in provided U Rack complele as per specification no WG-NAS/PP |
| 792 | Suppying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specificationNo WG-COC/PC |
| 793 | Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC |
| 794 | Supplying, Installing & Testing UTP Connector (RJ-45)as per specification No WG,NAS/UTPC |
| 795 | Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, with core dia 50/125 Lm (OM4) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC |
| 796 | Supplying and erecting LSZH armoured multimode optical fibre cable with 24 fibres, core dia 50/125 μm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC |
| 797 | Supplying and fixing Rack mounted type 12 Ports, Light guide unloaded Interconnect Unit with adapter Panel for termination of Optical fibre cables on wall/ provided U Rack complete as per specification no. WG-NAS/ LIU |
| 798 | Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU |
| 799 | Supplying and fixing SC/LC type multimode duplex adapter to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/ millimetre A |
| 800 | Supplying and plugging 3 m fibre patch cord LC-SCmillimetre(50) OM4 LSZH duplex complete as per specification no. WG-COC/FPC |
| 801 | Supplying and plugging 3 m fibre patch cord LC-LCmillimetre(50) OM4 LSZH duplex complete as per specification no. WG-COC/FPC |
| 802 | Supplying and fixing SC/LC type multimode pigtails (OM4) as per specification complete. WG-NAS/LIU2 |
| 803 | Supplying & erecting Jelly filled armoured telephone cable 20 pair with 0.5millimetre diameterlaid in provided trench as per specification No. WGTW |
| 804 | Supplying & erecting Jelly filled armoured telephone cable 50 pair with 0.5millimetre diameterlaid in provided trench as per specification No. WGTW |
| 805 | Supplying & erecting Jelly filled armoured telephone cable 100 pair with 0.5millimetre diameterlaid in provided trench as per specification No. WGTW |
| 806 | Supplying & erecting Jumper wire with 0.5millimetredia as per specification No. WG-TW |
| 807 | Supplying, erecting &commissioning50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 808 | Supplying, erecting &commissioningMDF Box 100x100 pairs made from min. 1.5 millimetrethick MS sheet as per specification no. WG-TW |
| 809 | Supplying, erecting &commissioning MDF Box 200x200 pairs made from min. 1.5 millimetrethick MS sheet as per specification no. WG-TW |
| 810 | Supplying, erecting &commissioning MDF Box 400x400 pairs made from min. 1.5 millimetrethick MS sheet as per specification no. WG-TW |
| 811 | Supplying, erecting &commissioningMDF Box 800x800 pairs made from min. 1.5 millimetrethick MS sheet as per specification no. WG-TW |
| 812 | Supplying, erecting &commissioning10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 813 | Supplying and erectingPoly vinyl chloridebox trunking of size 100x50millimetre . with accessories on wall/ceiling as per specification No:GMA/ BOX . |
| 814 | Supplying and erectingPoly vinyl chloridebox trunking of size 50x50millimetre . with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 815 | Concealing of provided G.I. pipe/H.G. screwed conduit/ Poly vinyl chloridepipe in wall/floor/false ceiling complete as per specification No:WG-PW/CW |
| 816 | Supplying & erecting HMSPoly vinyl chlorideconduit 25millimetre .diameterWith necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 817 | Supplying and erecting 25millimetre diametercorrugated flexible polypropylene conduit |
| 818 | Supplying and erectingPoly vinyl chloridetrunking ( Poly vinyl chloridecasing-n-capping) of size 25millimetrewith accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 819 | Supplying and erectingPoly vinyl chloridetrunking ( Poly vinyl chloridecasing-ncapping) of size 40millimetrewith accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 820 | Supplying and fixing 42U floor mount server rack (Dimension-DxWxH – 800x600x1866millimetre ) as per specification No. WG-NAS/RAK |
| 821 | Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070 millimetre ) as perspecification No. WG-NAS/RAK |
| 822 | Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767millimetre ) as per specification No. WG-NAS/RAK |
| 823 | Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635millimetre ) as per specification No. WG-NAS/RAK |
| 824 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500millimetre ) as per specification No. WG-NAS/RAK |
| 825 | Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 826 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS. |
| 827 | Supplying, fixing, and configuring 20 SFP ports + 4 Combo SFP 10/100/1000 Base-T erected in provided rack complete. |
| 828 | Supplying, fixing, and configuring 20 Ports+4G Combo, Managed Layer 2, POE Switch erected in provided rack complete. |
| 829 | Supplying, fixing, and configuring 1-port mini-GBIC SXmillimetrefibre transceiver (up to 550m, support 3.3V power) erected in provided rack complete |
| 830 | Supplying and laying (including excavation of suitable width & depth up to 90centimetre ) 75millimetreoutsidediameterdouble wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |