Tender For Special Repair Of 10 X Jcos Living Accn (Bldg No Ta- 207 & Ta-208) Under Ge 865 Ews; 1 Demolition of cement concrete (unreinforced) in ground floor and pavings not exc. 15cm thick below or above ground level complete all as specified and/or as directed by the Engr-in-Charge. 2 Demolition of cement concrete (unreinforced) in any description and any position not otherwise specifically provided for complete all as specified and/or as directed by the Engr-in-Charge. 3 Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members, complete all as specified and/or as directed by the Engr-in-Charge. 4 Dismantling wooden fillets, rails, posts, rafters, purlins, grids for ceiling & wall panelling etc.under 40 Sq.cm in section as in unframed work, complete all as specified and/or as directed by the Engr-in-Charge. 5 Demolition of precast concrete block walling built in cement mortar including all quoins, arches, pillars etc. complete all as specified and/or as directed by the Engr-in-Charge. 6 Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and/or as directed by the Engr-in-Charge. 7 Taking down chowkhats/ frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each complete all as specified and/or as directed by the Engr-in-Charge. 8 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified and/or as directed by the Engr-in-Charge. 9 Hacking out old broken glass (any thickness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and/or as directed by the Engr-in-Charge. 10 Dismantling plain or corrugated steel/ fibre sheeting any gauge thickness including nanital or similar pattern complete all as specified and/or as directed by the Engr-in-Charge. 11 Dismantling wrought iron or mild steel work of any description not otherwise provided for angle iron or flat iron as in post and guard bars or grating, complete all as specified and/or as directed by the Engr-in-Charge. 12 Dismantling floor, hearth or wall tiling including wall cement mortar bedding (but not backing) and rubbish off premises complete all as specified and/or as directed by the Engr-in-Charge. 13 M&L for 25mm thick PCC 1:2:4, type B-0, (using 12.5mm graded crushed stone aggregate) as infloor finishes complete all as specified and/or as directed by the Engr-in-Charge. 14 M&L forNon skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11Sqm and not exc 0.18 Sqm in flooretc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match and and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and/or as directed by Engr-in-Charge. 15 M&L forNon skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18Sqm and not exc 0.38 Sqm in flooretc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match and and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and/or as directed by Engr-in-Charge. 16 M&L for glazed ceramic coloured tiles in vertical surfaces of size 450x350x7mm/ 350x250x7mmthick set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including rendering 10 mm thick in cement mortar (1:4) as in backing coat complete all as specified and/or as directed by Engr-in-Charge. 17 Demolition of reinforced cement concrete in ground floor and pavings not exc 15cm thick below or above ground level complete all as specified and/or as directed by Engr-in-Charge. 18 M&L form work to soffits of suspended slabs such as roof, floor slabs, landings etc not exc 200mm thick (horizontal or sloping), complete all as specified and/or as directed by Engr-in-Charge. 19 M&L for reinforced cement concrete 1:2:4 nominal mix type B-1 (20 mm graded aggregate) as in beam cantilevers, bressummers, lintels over 1.5 m span, complete all as specified and/or as directed by Engr-in-Charge. 20 M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirallyfor hoopingfor columns, hooking endsand binding with and includingmild steel wire (annealed) not less than0.9mm dia or securing with clips, complete all as specified and/or as directed by Engr-in-Charge. 21 M&L for mild steel steel TMT bars 6mm to 8mm dia cut to length, bent to shape reqd, incl cranking, bending spirally for hooping columns hooking ends and binding with mild steel wire annealed not less than 0.9 mm dia or securing with clips, complete all as specified and/or as directed by Engr-in-Charge.. 22 M&L for9mm thick prelaminated particle boardmedium interior grade, prelaminated oneside with decorated choice lamination & other side balancing whitelamination fixed with nails to timber frame work as in wall panelling, shelves/boarding complete all as specified and/or as directed by Engr-in-Charge. 23 M&L for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing whitelamination fixed with nails to timber frame work as in ceiling panelling, complete all as specified and/or as directed by Engr-in-Charge. 24 M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & liningfixed with nails exc 13 sqcm and not exc 25 sqcm in section, complete all as specified and/or as directed by Engr-in-Charge. 25 M&L for 2nd class soft wood clean sawn as in beading for edges of ceiling, lining, or wooden flooring work fixed with nails exc 6 sqcm and not exc 13 sqcm in section, complete all as specified and/or as directed by Engr-in-Charge. 26 M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws complete all as specified and/or as directed by Engr-in-Charge. 27 M&L for 75 mm PCC 1:2:4 type B-2 using 40mm graded aggregate as in plinth protection finished even and smooth without using extra cement, complete all as specified and/or as directed by Engr-in-Charge. 28 M&L Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade A in plinth protection, complete all as specified and/or as directed by Engr-in-Charge. 29 M&L for PCC 1:4:8, type D2, using 40mm graded crushed aggregate as in mass concrete and filling of foundation, complete all as specified and/or as directed by Engr-in-Charge. 30 Material and Labour precast cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in block masonry with solid blocks, exc.10cm in width and set in cement mortar 1:6, complete all as specified and/or directed by Engr-in-Charge. 31 All as per Serial item No. 30 above, but except blocks. 32 M&L for 10mm thick rendering on fair faces of brick or block works finished even and smooth without using extra cement in cement mortar 1:6 complete all as specified and/or as directed by Engr-in-Charge. 33 M&L for 10 mm thick rendering on fair faces of brick works finished even and smooth without using extra cement in cement mortar 1 : 4 including mixing WPC as per manufacturers instructions, complete all as specified and/or as directed by Engr-in-Charge. 34 Supply only integral liquid water proofing compound.Make : Pidilite/Sika/Asian paints 35 M&L for preparation of new plastered wall surface of any description and applying three coats of white wash complete all as specified and as directed. 36 M&L for preparation of new plastered wallsurface of any description and applying two coats of cement based paint over a coat of chalk whiting complete all as specified and/or as directed by the Engr-in-Charge. 37 S&F 2nd class soft wood plain, solid, straight chowkets and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and/or as directed by the Engr-in-Charge. 38 S&F for 35mm thick2nd class softwood, plain, framed, panelled shutters (any number ofpanels) with panels of timber flat on both sides (feather edged), or ofveneered particle board medium density, wood particle board with commercial face veneers, supply and fixed to chowkats, complete all as specified and/or as directed by the Engr-in-Charge. 39 S&F for 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides, supply and fixed to chowkhats, complete all as specified and/or as directed by the Engr-in-Charge. 40 S&F 2nd class soft wood 35 mm thick Glazed and Skelton shutter, open and prepared to receive the glass, gauze etc. (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc. complete all as specified and/or as directed by the Engr-in-Charge. 41 S&F for 30mm thick2nd class hardwood plain framed factory made glazed and skeletonwindow / ventilators shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beds for securing glass etc. size of members of shutters as specified in SSR part I, Section 8, clause 8.24(a) supplied and fitted to chowkats, complete all as directed by Engr-in-charge. 42 M&L for preparation of new untreated wood or wood based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 43 M&L sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane complete all as specified and as directed. 44 S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed. 45 S&F 3 mm thick figured glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed. 46 S&F 150mm long aluminium anodized, barrel tower bolt of extruded sectioncompleteall as specified and as directed. 47 S&F 100mm long aluminium anodized, barrel tower bolt of extruded section complete. 48 S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed. 49 S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodized, complete all as specified and as directed. 50 S&F in repair aluminium (die cast) body door closer hydraulically designation No 3 universaltype suitable for door shutter of 851 to1000mmin widthand weight61 to 80 kg complete all as specified and as directed. 51 S&F floor door stopper (length of cover plate ) 150mm long aluminium alloy body and tongueanodised with hard drawn steel springfixed in floorcompleteall as specified and as directed. 52 S&F 75mm long aluminium anodized, butt hinges of extruded section type C-21, completeall as specified and as directed. 53 S&F 100mm long aluminium anodized, butt hinges of extruded section type B-21 completeall as specified and as directed. 54 S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed. 55 S&F in repair 1200mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified. 56 M&L for cement concrete 1:4:8, type D-2, (40mm graded stone aggregate) 75 mm thick as in sub -floors, sub- bases, floors and pavings, etc. complete all as specified and/or as directed by the Engr-in-Charge. 57 M&L forchequered cement concrete tiles (glazed) 30cm X 30cm X 20mm thick, set, pointed & jointed in neat cement slurry in floors polished with grey cement & pigments and laid over 20mm thick cement screed base (1:6) and all as directed by Engr-in -Charge. 58 S&F MS Rolled sections in main and cross beams, hip and jack rafters; purlins where connected to common rafters running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and similar workconfirming to Fe-290, Gde-E-165 complete all as specified and as directed. 59 S&F Plates Fe-410W (GdeE-250)Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and as directed. 60 M&L for preparation new steel surfaces of any description, not otherwise described, over 10cm width/girth and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. 61 S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mps as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and/or as directed by the Engr-in-Charge. 62 S&F in repair19mm dia mild steel, chromium plated curtain rods,withbrackets, end bulbs all as specified and as directed by Engr-in-charge. 63 Demolition of stone boulder masonry built in cement mortar including all quoins, arches, pillars etc and removing demolished material off the premises complete all as specified and/or as directed by the Engr-in-Charge. 64 M&L walling of random rubble stone masonry, uncoursed well bonded, and solidly hearted, built in CM 1:6 complete all as specified and/or as directed by the Engr-in-Charge. 65 All as per Serial item No. 64 above, but except stones. 66 M & L for reinforced Cement Concrete 1:2:4 type B1 using 20mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge. 67 M&L for precast cement concrete 1:2:4, type B1,(20mm graded stone aggregate) in landings, cover slabs (for manholes etc), chullah hoods, chhajja, water troughs, shelves and similar articles with plain faces, setting in CM 1:6, including necessary formwork complete all as specified and/or as directed by the Engr-in-Charge. 68 M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge. 69 M&L form work to rough finished edges of concrete flats, treads breaks in floors, window cills, concrete failings, openings in concrete walls, floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls,horizontal or sloping and similar work , complete all as specified and directed. 70 S&Fin repairs Towel Hanger with 6 Nos of pin and600mm long chromium plated complete fitted all as specified and/or as directed by the Engr-in-Charge. 71 Taking up or down existing steel/ PPR tubing and connections, 25 or 32 mm bore of pipe and connections in any position including cleaning for refixing or removal to store complete all as directed by Engr-in-Charge. 72 S&F 3-layer PP-R( Polypropylene random copolymer)pipes 25mm diaSDR 7.4 & SDR 11 UV stabilized and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floor etc. all as specified and directed. 73 S&F 3- layer PP-R( Polypropylene random copolymer)pipes 32mm diaSDR 7.4 & SDR 11 UV stabilized and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floor etc. all as specified and directed. 74 S&F 25mm PP-R Gate valves (brass insert) conforming to ISO 2000 screw down end for PPR pipe or for union and fixed, complete all as specified and/or directed by Engr-in-Charge. 75 Dismantling water tanks and removing to store exc 250 and not exc 500 ltrs capacity, complete all as specified and as directed. 76 S&F500 litres capacityrotational moulded polyethylene water storage tanks (Cylindrical vertical, with closed top), hoisted and fixed in position all as specified in SSR Part I, complete all as specified and as directed. 77 S&F in repairs vitreous China wash basin fancy type pedestal pattern, white, flat back, size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and as directed. 78 S&F in repairs vitreous China squatting pan or Orissa pattern580 x 440 mm white with integral foot rest (excluding cistern)with front or back inlet ant pattern as in repairs incl bedding with PCC 1:2:4 type B-I, using 20 mm graded crushed stone aggregate, complete all as specified and/or directed by Engr-in-Charge. 79 S&F in repairVitreous china wash down water closet (Pedestal), white (EWC) including Plastic seat of same colour of WC, closed pattern with flat bottom, and cover and Mild steel chromium plated hinging device complete all as specified and/or directed by Engr-in-Charge. 80 S&F PVC (SWR) S’ trap of 125/110 mm bore, complete all as specified and as directed. 81 S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 82 S & F in repairs CPtoilet jet spray ABS with double lock 1.2 mtr CP tubestainless steel flexible hose all as specified and as directed. 83 Supply & fix sheet glass shelf assembly consisting of 8mm thick glass shelf 300 x 300mm as in corners wide with bevelled edges/hatching of edges fixed with stainless steelD bracket fixed and railing complete all as specified and directed. 84 S&FSoap dish, any type, fixed to plugs with chromium plated brass screws completed all as specified and directed. 85 Supply and fix flushing cistern of PVC 10 ltr. cap. with dual flushing system, white colour, valveless symphonic action type,low level, with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified and directed. 86 S&F in repair Bib taps, CP,fancy type long nose with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete in all respect all as specified.Make : Jaquar/ Hindware/ Cera/ Prayag 87 S&Fin repair angular Stop Cock, CP, fancy type with wall flange, fancy type chromium plated cast copper alloy screwed down, high pressure, screwed ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified.Make : Jaquar/ Hindware/ Cera/ Prayag 88 S&F in repair towel rod CP 60 cm long between flanges and including all accessories like brackets/screws etc. as recommended by manufacturer and complete fixed in position complete all as specified. 89 S&Fin repairPVC connections 15mm size with brass nuts of length 450mm complete all as directed and specified. 90 S&F in repair 15 mm bore pillar taps, fancy type Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and as directed. 91 Supply only 32 mm dia PVC waste pipe for wash hand basin / Kitchen sink etc complete all as specified. 92 S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified. 93 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) 94 S&F PVC (HDPE) SWR 110 mm bore, single socketed in any length with rubber ring joints using solvent as per manufacture instruction,laid in trenches or in floor complete all as specified and directed by Engr-in-Charge.Make : Astral / Prince / Finolex 95 S&F in PVC (HDPE) SWR 75 mm bore, single socketed in any length with rubber ring joints using solvent as per manufacture instruction, fixed to wall complete all as specified and directed by Engr-in-Charge. 96 S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 97 S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 98 S&F PVC (HDPE) SWR 75 mm bore, single socketed in any length with rubber ring joints using solvent as per manufacture instruction,laid in trenches or in floor complete all as specified and directed by Engr-in-Charge.Make : Astral / Prince / Finolex 99 S&F in repairs PVC (SWR) 75 mm dia floor trap with plain with grating including jointing with solvent cement complete all as specified and directed. 100 S&F in repairs grating doom 75mm dia of PTMT (min weight 25gms) complete as specified and directed. 101 S&F PVC (SWR) 75 mm bore vent cowl complete all as specified 102 M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100mm bore pipe line complete all as specified and as directed by the Engineer-in-Charge 103 Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as specified and directed. 104 Taking down of submain wiring surface of wall, floors / ceiling and match the existing complete all as specified and directed. 105 Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth leadall as specified and directed for the followings:- 106 One light/exhaust fan point controlled by one way switch. 107 One switch socket outlet 6 Amps, 230 volts point on Same board. 108 One switch socket outlet 6 Amps, 230 volts point on independent board. 109 All as peritem No 105 above, but using cables 4 Sq mm size. 110 Supply and fix in replacement of lamp holder insulated body with back plate complete all as specified and directed. 111 Supply and fix switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and directed. 112 Supply and fix switch Socketoutlet two in one5 pin 6 Amps flush type.230 volts complete all as specified and directed. 113 Supply and fix switch Socket combination outlet multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as specified and directed. 114 Supply and fix ceiling rose, surface Bakelite three terminals complete all as specified and directed. 115 Supply and fix in replacement of sheet metal enclosure for DBs double door when MCBs to be used single pole & neutral 240 Volts 8Ways complete all as specified and directed. 116 Supply and fix MCB SPN 63 Amp, 240 Volts, AC ISI marked complete all as specified and directed. 117 Supply and fix MCB SP 6-32 Amps, 240 Volts,50 HZ complete all as specified and directed. 118 Supply and fix submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing caping wire size 2x6.0 sq. mm + 1x6.0 sq. mm earth wire complete all as specified and directed. 119 Supply and fix in replacementLED light fitting 1 x 20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 120 Supply and fix in replacement LED luminaire 600mm x 600 mm, 35/36 watt,220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable sizecomplete all as specified and directed 121 Supply and fix in replacement connecting and testing LED security light fitting 35 watt, 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp and bracket with impact and corrosion resistant incl thermal management in multiple optics complete all as specified and directed. 122 Supply and fix in replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtrs deep below normal ground level with top edge of earth plate not less than 1,5 ntrs below normal ground level connected to galvanised iron strip 32 x 6mm as earthing leads by means of galvanised bolts, nuts, check nuts and washer of galvanised iron or steel complete with 20 mm dia GI Pipe light grade for watering and 40mm dia GI light grade pipe for protection of strip up to test point including test point of strip 50x50x3mm GI, charcoal dust, common salt 15cm all around the earth plate all as shown in electric plate No.3 of MES SSR Part-I all as specified or indicated and testing on completion including necessary excavation, earth work PCC pit and with RCC cover of suitable size water funnel with wire mesh complete all as specified and/or directed by Engr-in-Charge. 123 Supply and fix in repairairCirculatorsteel body AC single Phase 230V of size 300 mm with electric driver with blades, and frame and louvers complete all as specified and directed. 124 Supply, lay and testing cable XLPE in replacementInsulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core from bus bar panel to main DB complete all as specified and directed. 125 Supply, lay and testing cable XLPE in replacementInsulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core complete all as specified and/or directed by Engr-in-Charge. 126 Excavation in trenches, not exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cable in trenches not exc. 10sqm on plan and not exc 1.5 m in depth in any type of soil and getting out complete all as specified and directed. 127 Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed. 128 Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the startingpoint, complete all as specified and directed. 129 M&L for Sand cushioning to under ground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, 2009.Note : Punned thickness only will be measured and paid. 130 Supply and layingof factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-2 flat size 250 mm x 150 mm x 40mm, complete all as specified and directed. 131 Supply and fix in replacementof bus bar chamber size 600 x 450 x 300 mm outdoor type made out of MS sheet 2.0 mm thick mounted on angle iron frame duly painted with two coats of synthetic enamelled paint over a coat of primer and comprising of three phase aluminium bus bar 200 amps mounted on insulators including provisioning of foundation all as specified and directed.