| 1 | Surface excavtion in soft/ loose soil n.exc 30 cm in depth and averaging 15 cm deep and getting out complete all as specified and directed. |
| 2 | Excavtion in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundations etc or for shafts, wells, cesspits, manhole, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 mtr in depth in soft/ loose soil andgetting out complete all as specified and directed. |
| 3 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil complete all as specified and directed. |
| 4 | Returning, filling in ,including spreading, levelling, watering and well ramming in layers n.exc 25 cm in depth complete all as specified and directed. |
| 5 | Removal of excavted soil n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate crushed stone aggregate as in foundations/ mass concrete complete all as specified and directed. |
| 7 | M&L for RCC M-25 (nominal mix) as in foundations, footing, plinth beams complete all as specified and directed. |
| 8 | M&L for RCC M-25 (nominal mix) as in columns complete all as specified and directed. |
| 9 | Use and waste of formwork to sides of concrete foundations, footings, sides and soffits of foundations (if any) of foundation and plinth beams and similar work ,verticalor to batter for rough finished surfaces complete all as specified and directed. |
| 10 | Use and waste of formwork to sides and soffits of floors or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports.Overhangs etc splays between floors and beams for flat fair finished surfaces complete all as specified and directed. |
| 11 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor fair finished surfaces complete all as specified and directed. |
| 12 | M&L for TMT steel bars as in reinforcement, 10 mm dia and over ,cut to length, bent to shape required, including cranking, hooking ends and blinding withmild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 13 | All as item No 12 above herein beforebut 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and blinders etc complete all as specified and directed. |
| 14 | M&L for Fe410-W(Gde-250)quality B roof truss (framed), trussed, prulins.crane gantries, rails and fasteining and heavybracket framing (beams, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 15 | M&L for girder or single stanchion, built up of one beam or channel section with flange plates, caps, bases, splices angle brackets, cleats and other connections complete all as specified and directed. |
| 16 | M&L for mild steel bolts of 20 mm dia purpose made with hexagonal or square head one end and serewed other end or screwed both ends, each serewed end to end fitted with washers and one hexagonal or squarre nut, exc 30 cm long complete all as specified and directed. |
| 17 | S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of camouflage pattern having tensile strength of 550 mpa as in roof covering/ ridge/ cladding to wall, fixed with self tapping screw (heavy duty) with in built washers and neoprene and EDPM washers, in roofs, walls etc complete all as specified and directed. |
| 18 | S&F for pre painted galvalume aluminium zinc coating GI based plain/ corrugated steel sheet 0.50 mm thick of camouflage pattern having tensile strength of 550 mpa as in ridges, hips, valley gutter, drip or straight fastening etc fixed with self tappingscrew etc complete all as specified and directed. |
| 19 | M&L for brick work with sub class \"B\" bricks (old size), straight or curved on plan exceeds 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 20 | M&L for Rendering 15mm thick in cement mortar 1:4 on other than fair faces of brickwork or concrete sur faces even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brickwork or concrete sur faces even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for Preparing newly plaster surfaces of wall and applying two coat of white wash complete all as specified and directed. |
| 23 | M&L for preparation of new plastered surfaces and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 24 | M&L for Hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface for plinth protection/ under floor complete all as specified and directed. |
| 25 | M&L for 75 mm thick plain cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protection complete all as specified and directed. |
| 26 | M&L for 100 mm thick plain cement concrete Type D-2 1:4:8 (using 40 mm graded stone aggregate) as in paving/ under floor complete all as specified and directed. |
| 27 | M&L for 100 mm thick plain cement concrete Type B-2, 1:2:4 (using 40 mm graded stone aggregate) in flooring complete all as specified and directed. |
| 28 | M&L for Moorum/ red bajri filling in floors orpavings, laid in layers n.exc 15 cmthick, spread, levelled and rammedincluding watering complete all as specified and directed. |
| 29 | M&L for Preparation of new steel Surfaces of any description, over 10cm in width or girth, of any description and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 30 | S&F for Glass dividing strips, 3 mm thick 38mm width and inserted in postion complete all as specified and directed. |
| 31 | Supply only integral water proofing compound complete all as specified and directed. |
| 32 | S&F for Steel windows with side hungshutters including projecting typehinges with steel handle, and steelpeg stay,complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 33 | M&L for 2nd Class Hard wood ( Sal) Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed including tarring back of chowkhats with tar or coal tar black paint complete all as specified and directed. |
| 34 | M&L for 35 mm thick, IInd class HW(sal), factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR part-I, Section-8, clause 8.24 (a) supplied and fitted to chowkhats complete all as specified and directed. |
| 35 | M&L for 35 mm thick, IInd class HW(sal), factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into square with plain, chamfered or rounded, mitred and rebated sash bars, any numbers with edge of sash bars, forming moulded for window etc provided with stile and rails as specified in SSR part-I, Section-8, clause 8.24 (b)supplied and fitted to chowkhats complete all as specified and directed. |
| 36 | M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in hold fast block, filling in pressed steel chowkats including necessary form work etc complete all as specified and directed. |
| 37 | S&F for 4mm thick sheet glass, ordinary quality, in squares not exceeding 0.5 Sqm in each pane, glazed with putty or fixed with beads complete all as specified and directed. |
| 38 | S&F for butt Hinges, medium weight, cold rolled mild steel, 125 mm size complete all as specified and directed. |
| 39 | S&F for Aluminium handles, cast type anodised, 150 mm long complete all as specified and directed. |
| 40 | S&F for Aluminium, anodised, barrel tower bolts of extruded section and fixed, 150 mm length of bolt complete all as specified and directed. |
| 41 | S&F for aluminium anodised slidingdoor bolt 250mm long with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 42 | M&L for framed work such as grills,gratings etc with ends of barsshouldered and/ or riveted,or forged into spikes, framedguard bars, barred iron doors,ladders, framedbalusters, walkways, railings, framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 43 | M&L for Treating the bottom and sides of excavationat the rate of 5 litres of emulsion per squaremetre of surface area complete all as specified and directed. |
| 44 | M&L for treating the backfill in contact withfoundation at the rate of 7.5 Litres ofemulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 45 | M&L for Treating the top surface of filled earth atthe rate of 5 Litres of emulsion per squaremetre of surface complete all as specified and directed. |
| 46 | M&L for Treating the soil under plinth protectionat the rate of 5 Litres of emulsion per squaremetre of surface area complete all as specified and directed. |
| 47 | M&L for Treating the soil along with externalperimeter of building at the rate of 2.25 Litreof emulsion per metre of the perimeter wall complete all as specified and directed. |
| 48 | M&L for plain cement concrete 100 mm thk 1:3:6 type C-2 ( using 40 mm graded stone aggregate) crushed stone aggregate as in sub floors, sub bases, floors and paving etc complete all as specified and directed. |
| 49 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 50 | M&L for plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation, filling, mass concrete works complete all as specified and directed. |
| 51 | M&L for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts ; angle posts and struts in fencingincluding cutting tops to shape as directed, driliing holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessarydrilling, bolting or riveting etc and similar work complete all as specified and directed. |
| 52 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square n.exc 5cm but n.exc 10 cm of dia 10mm complete all as specified and directed. |
| 53 | Supply only Chain link MS galvanisd fencing anysize or type complete all as specified and directed. |
| 54 | Fixing only chain link fencing including linewires, any mesh, size and type to any typeof standards, rails, straining bolts, etc including provission of binding wire complete all as specified and directed. |
| 55 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 56 | M&L for framed work such as grills gratings, etc, with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, framed and hung as gates, including pintle hinges, holdfasts etc, pivots to be fixed in PCC as directed by GE, stops, hand made MS sliding bolts, tower boldts incl ornamental and design etc complete all as specified and directed. |
| 57 | Removing excavated material exc 250 m but n.exc 500 m and depositing where directed complete all as specified and directed. |
| 58 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggreate) as in foundation/ mass concrete complete all as specified and directed. |
| 59 | M&L for applying two coats of cement based paintover a coat of primer andalkaliresistant priming paint on newly plaster surface complete all as specified and directed. |
| 60 | M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour codingdrawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etcincluding provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FRLS (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly, modular sheet steel sunken terminal box of appropriate size suitable for modularswitch/ fittingsconcealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits andsinking for boxes and making good to the disturbed surfaceof wall/floor and matching with existing specifications. Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles complete all as specified and directed for the following :- |
| 61 | One light point controlled by one way switch 5/6 amps. |
| 62 | One ceiling fan/Exhaut fan/Wall Fan point controlled by one way switch 5/6 amps. |
| 63 | One socket out let 5/6 amps point on the independent board |
| 64 | One socket out let 5/6 amps point on the same board |
| 65 | S&F for switch socket combination 3 pin 5/6 Amps, piano flush type 230 V complete all as specified and directed. |
| 66 | S&F for switch piano flush type 5/6 Amps, 230 volt, one way, single pole complete all as specified and directed. |
| 67 | S&F for ceiling rose surface type bakelite 3 terminals 230 volts AC complete all as specified and directed. |
| 68 | S&F for IP 20, class I, LED light 1X18/20 W (or nearest next higher wattage) (4feet), 6500K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecing up complete all as specified. Make : Havells Cat Part No:- LHEXAPP7PN1W020. |
| 69 | S&F for copper wound ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE.Energy efficient, five star rated, with brushless direct current motor (BLDC) complete with mounting arrangment as per site requirementand connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed. |
| 70 | S&F for LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete withstreet light bracket made out of GI pipe light grade 25 mm dia 1.5 mtr long bent to required shape as directed and fixed to pole complete with two coats of aluminium paint over a coat of red oxide primer including clamps and nut, bolts and washers complete all as specified and directed.Make : Crompton Cat Part No TRP-400-35-57-SL-LM-NSR. |
| 71 | S&F for MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar, neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and directed. |
| 72 | S&F for MCB TPN4 pole 25 to 63 Amps, 415 volts, C - curve, 10 kA complete all as specified and directed. |
| 73 | S&F for MCB SP 10 to 32 Amps, 230 volts, C curve, 10 kA complete all as specified and directed. |
| 74 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6.3mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion complete all as specified and directed. |
| 75 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid. |
| 76 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified. |
| 77 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and directed. |
| 78 | M&L for horizontal boring across the existing road without disturbing the road surface for insertingGI pipe complete all as specified and directed. Note :-(i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch \"A\". |
| 79 | M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. |
| 80 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLS Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC casing caping, medium grade of suitable size including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover / plastic gang box for mounting of switch, socket,fan regulator complete all as specified and directed for following:- |
| 81 | Exhaust fanpoint controlled by one number one way switch. |
| 82 | S&F for exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250 mm including making hole for 250 mm Sweep plastic fan in suitable square/rectangle/circle shape in wall/window and making good disturbed surfaces of walls/minor alteration in window frame if required complete all as specified and directed. |
| 83 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |