}

Tender For Construction Of Interior And Renovation Work In Pg Block Third Floorat Vpsv Ayurveda College , Kottakkal - Construction Of Interior And Renovation Work 2 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stackin, kottakkal-Kerala

Ayurveda Medical Education has published Tender For Construction Of Interior And Renovation Work In Pg Block Third Floorat Vpsv Ayurveda College , Kottakkal - Construction Of Interior And Renovation Work 2 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stackin. Submission Date for this Tender is 19-08-2025. Building Work Tenders in kottakkal Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

50539708
Tender For Construction Of Interior And Renovation Work In Pg Block Third Floorat Vpsv Ayurveda College , Kottakkal - Construction Of Interior And Renovation Work 2 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stackin
Tender
Indian
Kerala
Kottakkal
19-08-2025

Tender Documents

Tender Details

Tender For Construction Of Interior And Renovation Work In Pg Block Third Floorat Vpsv Ayurveda College , Kottakkal - Construction of Interior and Renovation Work 2 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm 3 15.12.1Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below 4 15.56Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 5 15.7.4Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 15.60Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved 7 5.2.2Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 8 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 9 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 10 6.47Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor Vlevel with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-inCharge. (Thepayment of RCC band and reinforcement shall be made for seperately). 11 50.6.1.8Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete 12 13.1.112 mm cement plaster of mix:1:4 ( 1 cement :4 fine sand) 13 od24058/2025_2026Supplying and filling with cinder under ramming consolidating and dressing complete. Including all cost of materials, Labour charges etc complete. 14 4.2.2Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3 (1 cement : 11/2 coarse sand :3 graded stone aggregate 20 mm nominal size) 15 22.5Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 16 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 17 11.46.2Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm 18 od4180/2025_2026Modified 8.31 Providing and fixing Camilla Marfil wall tiles of size 400 x 800 mm conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, as approved Engineer-incharge shades except burgundy, bottle green, black of any size as approved by EngineerinCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement 3 coarse sand) and jointing with cement slurry @ 3.3 Kg per sqm, Including pointing in white cement mixed with pigment of matching shade complete. 19 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete. 20 9.119Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturers specification and direction of Engineer-in Charge. 21 9.1.20.1Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC C channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5mmx2)thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufactures specification & drawing.30 mm thick plain PVC door shutters 22 50.9.15.1Supplying and fixing 200 mm Aluminium aldrop 23 9.147C.2Providing and fixing factory made uPVC white colour casement/ Casement cumfixed glazed doorcomprising of uPVC multi-chambered frame, sash and mullion(where ever required) extruded profilesduly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hingesand one handle on each side of panels along with zinc plated mild steel multipoint locking having transmission gear, cylinder with keeps and one side key,G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessarystainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded includingdrilling of holes for fixing hardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealent over backer rod of required size and of approvedquality, all complete as per approveddrawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealent shall be paidseparately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% toleranceindimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with3D and S.S. friction hinges (400 x19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110mm & mullion67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead /doubleglazing bead of appropriate dimension.(Area of door upto 2.50 sqm) 24 9.147D.3Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in heightdimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and ofapproved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single /double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame andsash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall beacceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm &sash 46 x 62mm both having wall thickness of 2.3 +/- 0.2 mm and single glazingbead / double glazing bead ofappropriate dimension . (Area of window above1.75 sqm upto 2.50 sqm). 25 9.151Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. 26 21.1.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron ) 27 21.1.2.3For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn) 28 21.3.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 29 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 31 13.88Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc complete. 32 13.98.1Wall painting with plastic emulsion paint of approved brand and manufactureto give an even shade:One or more coats on old work 33 13.99.1Painting with synthetic enamel paint of approved brand and manufacture ofrequired colour to give aneven shade :One or more coats on old work 34 25.7Designing , fabricating, Testingand fixingin positioncurtainwall with Aluminiumcompositepanel cladding ,with open grooves for linear as well ascurvilinear portion of the building, for all heights and all levels etc. includinga) Structural analysisand designand preparationof shop drawingfor pressure equalisationor rainscreen principle as required, proper drainage of water to makeit watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium compositepanel cladding in pan shape in metalic colour of approved shades made out of4mm thick aluminium composite panel material consisting of 3mm thick FR grademineral core sandwiched between two Alumini um sheets (each0.5mm thick). Thealuminium composite panel cladding sheet shall be coil coated, with Kynar500based PVDF / Lumiflon based fluoropolymer resin coating of approved colourand shade on face # 1 and polymer (Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backerrods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanisedwith serrations and serrated washers to arrest the wind load movement, fasteners,SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators toprevent bi-metallic contacts all complete required to perform as per specificationand drawing The item includes cost of all material & labour component, the cost ofall mock ups at site, cost of all samples of the individual components for testing inan approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wallwith aluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose ofpayment, only the actual area on the external face ofthe curtain wall with Aluminum Composite PanelCladding (including width ofgroove) shall be measured in sqm. up to two decimal places. 35 25.1Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account). 36 od4807/2025-26Cement fiberboardceilingwithGroovesprovidingand fixing falseceilingat allheight includingproviding and fixing offramework made of specialsections, powerpressedfrm M.S Sheetsand galvanized with Zinccoatingof 120gms/sqm(both side inclusive ) as perIS:277 andconsisitingof angle cleats od size25 mm wide x1.6mm thickwith flanges of 27 mm and 37mm at 1200mmcentre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,.Including the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeterchannels suitably fixed, all complete as per drawings, specification and direction of the Engineer inCharge but excluding the cost of painting with: 6 mm thick High density cement fibre board(CenturyZykron /Equivalent) with grooves on joints and finished with silicon 37 od4832/2025_2026Gypsum Board Partition : Providing and fixing partition up to ceiling height (upto 360cm) consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both sideinclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacturesspecification and direction of engineer in charge all complete.75 mm overall thickness partition with12.5 mm thick Moisture Resistant Board.9.105.1 (Modified) 38 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface:Water thinnable cement primer 39 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 40 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Twoor more coats on new work 41 od4890/2025_2026Toughened Glass Partition : Providing and fixing 12mm thick Toughened glass(Saint Gobain)Partition System(upto a height of 165cm ) with SS Patch Fittings(Dorma /Equivalent) as per drawing /instruction of Engineer in charge.Including all cost and conveyance of materials, labour etc complete. 42 od4892/2025_2026:Toughened Glass Door Providing and fixing door of 12mm thick Toughened glass door (SaintGobain) with dorma (Crown) patch fittings(Floor Spring, Top patch, pivot Pin, Bottom patch, Corner lock, Handle.Including all cost and conveyance of materials, labour etc complete. 43 od4903/2025_2026:Flush door( Laminate Finish) : Providing & Fixing Plywood Door as per architect approveddrawing. Shutter frameworks finished with 19 mm plywood (IS 710 Grade,BWP Prestige/Equivalent).Both sides of the frame to be finished 9 mm plywood with 1 mmthick laminate finish (Genial weave 4855 , laminates/equivalent) using suitable adhesive(HeatX/Equivalent).8mm thick Clear glass to be fixed in the door as per design intent.Complete usingnecessary SS Hinges, Tower bolts, lock,handle etc, (Hafele/Hettich/Ebco/equivalent) etc., Finish the doors with necessary grooves etc. if any. Including cost and conveyance of all materials labour charges etc. complete as per drawing. 44 od4936/2025_2026Sliding door( Laminate Finish) : Providing & Fixing Sliding Plywood Door as per design intent. Shutter frameworks finished with 19 mm plywood (IS 710 Grade,BWP Prestige/Equivalent).Bothsides of the frame to be finished 9 mm plywood with 1 mm thick laminate finish (Genial weave 4855 , laminates/equivalent) using suitable adhesive (Heat X/Equivalent).8mm thick Clear glass to be fixed in the door as per design intent.Complete using necessary Sliding Track,lock,handle, etc ( Hafele /Hettich/Ebco/equivalent) etc., Finish the doors with necessary grooves etc. if any. Including cost and conveyance of all materials labour charges etc. complete as per drawing. 45 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 46 od4952/2025_2026Plywood panelling /Decking (19 mm):Providing and fixing panelling using plywood, 19 mm thick plywood (IS 710 Grade BWP Prestige/Equivalent ) to be fixed onto existing framework using drywall screws and adhesive.Complete as per the direction of Engineer- in- Charge including all cost of accessories, labour charge etc. complete. 47 od4963/2025_2026:Carpet Flooring (Stage) :Providing and fixing 5 mm thick carpet (Shade: Lotus , Brand: ROSSETTA, Make:MILANO /Equivalent) as per design Intent. Including cost and conveyance of all materials labour charges etc.complete as per direction of Engineer-in charge 48 9.84Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 49 17.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 50 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in-charge 51 17.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 52 17.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillers 53 17.23Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of430x260x350 mm or 340x410x265 mm sizes respectively. 54 od24030/2025_2026Supplying and fixing 100mm or nearest size PVC floor trap and Stainless steel gratings (150x150 mm)with all fittings, Including cost and conveyance of all materials and labour charges etc. 55 od23832/2025_2026Providing and fixing C.P Brass angle valve for basin mixer and geyser points of approved quality 56 od23833/2025_2026Providing and fixing of steel urinal push cock of approved quality make. including all conveyance and labour charges etc 57 od23834/2025_2026Providing and fixing C.P brass long body bib cock of approved quality.including all conveyance andlabour charges etc 58 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials andlabour charges etc complete as per the direction of site Engineer-in-charge. 59 50.18.8.6.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 60 50.18.8.7.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 61 50.18.8.8.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 62 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 63 50.18.7.6.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall 64 50.18.9.17.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall 65 50.18.9.18.1Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. Thisincluded jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 66 50.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 67 od23843/2025_2026OD Derived Providing and fixing GI slotted rail of approved design. projecting 75 mm outsidethe wall surface and fixed on wall with 2 nos, 6/8 mm dia expansion hold fasteners, includingdrilling necessary holes in brick wall / CC / RCC surface and the cost of bolts included. The pipesshall be fixed to the already fixed brackets with the help of 8 mm galvanised GI U bolts ofspecified shape and shall be fixed with GI nuts, bolts, & washers of suitable size, one bolts on eachside of the pipe. 68 od24029/2025_2026Providing and fixing in position FRP manhole cover and frame of required shape and approved quality.LD-2.5 Rectangular in shape 600x600 mm internal dimensions 69 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 70 50.18.9.20.2Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow 71 0.18.9.20.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 72 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 73 50.18.9.20.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 74 50.18.9.20.9Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling 75 od23961/2025_2026Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Y 76 50.18.9.21Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow 77 50.18.9.21.2Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 78 50.18.9.21.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 79 50.18.9.21.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee 80 50.18.9.21.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 81 50.18.9.21.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 82 50.18.9.21.9Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling 83 od23965/2025_2026Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing withPVC solvent cement - 75 mm dia Y 84 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow 85 50.18.9.22.2Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 86 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 87 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee 88 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 89 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 90 50.18.9.22.11Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 91 50.18.7.2.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall 92 50.18.7.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall 93 50.18.7.4.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 94 50.18.7.5.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10 Kgf/cm2- Internal work- exposed on wall 95 d23971/2025_2026 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Y 96 od23972/2025_2026Providing and fixing ball valve (brass) of approved quality of following sizes. Make:Zoloto/SKS/Cim/Equivalent50mm dia 97 od23973/2025_2026Providing and fixing ball valve (brass) of approved quality of following sizes.Make:Zoloto/SKS/Cim/Equivalent 32 mm dia. 98 od24031/2025_2026Providing and fixing ball valve (brass) of approved quality of following sizes. Make:Zoloto/SKS/Cim/Equivalent 40mm dia 99 od24032/2025_2026Providing and fixing ball valve (brass) of approved quality of following sizes. Make:Zoloto/SKS/Cim/Equivalent 25 mm dia. 100 18.19.3.2Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominalboreVertical 101 od23975/2025_2026CORE CUTTING + HOLE PACKING Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant withnecessary form work, staging, tools, etc., ( if required) RCC SLABS (Up to 30 cm Thickness) 110 mm 102 od23976/2025_2026CORE CUTTING + HOLE PACKING Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant withnecessary form work, staging, tools, etc., ( if required) RCC SLABS (Up to 30 cm Thickness) 50 - 75 mm 103 od23977/2025_2026CORE CUTTING + HOLE PACKING Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant with necessary form work, staging, tools, etc., ( if required) RCC SLABS (Up to 30 cm Thickness) 40 - 50 mm 104 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 105 Electrification work 106 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 107 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 108 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 109 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 110 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. Mm 111 1.17.30Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. Mm 112 1.17.32Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. Mm 113 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduitas required1 run of Cable 114 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc. as required.Group C 115 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm 116 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 117 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 118 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 119 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 120 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 121 1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). 122 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.1 or 2 Module (75mmX75mm) 123 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.3 Module (100mmX75mm) 124 1.27.3Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.4 Module (125mmX75mm) 125 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.6 Module (200mmX75mm) 126 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.8 Module (125mmX125mm) 127 90.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recessincluding making good the damages, colour washing etc as required (RoHS compliant )2 modulemoulded plastic box on surface 128 1.34Supplying and fixing brass batten/ angle holder including connection etc. as required 129 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincludingconnection etc as required. 130 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modularplate as required. 131 1.21.3Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32mm 132 od25263/2025_2026Suppling and fixing modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. RJ45 CAT 6 Socket 133 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plateswitch box including connections but excluding modular plate etc. as required. 134 90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) 135 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door 136 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 137 od24857/2025_2026Supplying and fixing 5 to 40 Amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. Triple pole 138 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps 139 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps 140 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 141 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 142 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 143 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 X 10 sq. mm (25mm) 144 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm withfactory made clamp 145 4.6.4Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisationthickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joinedwith connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. asrequired.300 mm width X 50 mm depth X 1.6 mm thickness 146 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) 147 1.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of alltypes, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required 148 1.50.1Installation of exhaust fan in the existing opening, including making good the damage connection testing,commissioning etc. as required.Upto 450 mm sweep 149 od24883/2025_2026Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers workingon 230 V AC supply complete with all accessories as required. 150 od25049/2025_2026Supply and installation of 9 watt LED Bulb , day cool white 151 od25166/2025_2026supply of 1x20 W LED box type tube fittings. The fittings shall be made from CRCA MS sheet of minimumthickness 0.50 mm nominal thickness inside & outside (including LED Tube). 152 od25235/2025_2026Supply and fixing of 60 cm galvanized steel or powder coated fan rod with suitable fan hook, including allaccessories etc as required 153 d25495/2025_2026Supply of LED recessed or surface mounted 12 Watt panel light . Housing made up of aluminium diecast,act as heat sink.LED efficiency not below 90 lumen/ watt, colour, 6500 K Colour temperaturesuitable for indoor applications, including all connections are required. make wipro , philips, equilant 154 od25497/2025_2026Supply of LED recessed or surface mounted 9 Watt panel light . Housing made up of aluminium diecast,act as heat sink.LED efficiency not below 90 lumen/ watt, colour, 6500 K Colour temperaturesuitable for indoor applications, including all connections are required. make wipro , philips, equilant 155 od29408/2025_2026Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes usingstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVCinsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan(BLDC) complete with 300mmdown rod , canopies, shackles and blades working on 230V/240V single phase A/c 156 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Complete 157 13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as permanufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.Onsteel work 158 1od25259/2025_2026Preparation of all drawings, submitting and getting approval from Electrical Inspectorate, Submitting ofcompletion certificates and arranging inspection , getting sanction and energization certificates fromElectrical inspectorate and commissioning of the whole installation in the premises. All statutorypayments will be reimbursed on production of the original receipts.

Key Value

Document Fees
INR 2500 /-
EMD
INR 50000.0 /-
Tender Value
INR 43.11 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail