}

Tender For Addn /Altn To Room No 39, 40, 65 & 66 At Chandimandir, chandimandir-Haryana

Military Engineer Services has published Tender For Addn /Altn To Room No 39, 40, 65 & 66 At Chandimandir. Submission Date for this Tender is 25-08-2025. Building Work Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

50514894
Tender For Addn /Altn To Room No 39, 40, 65 & 66 At Chandimandir
Tender
Indian
Haryana
Chandimandir
25-08-2025

Tender Documents

Tender Details

Tender For Addn /Altn To Room No 39, 40, 65 & 66 At Chandimandir; 1 Powder coated aluminium door frame ofhollow section 100x40mm and including aluminium glazed shutters stiles 95x45mm & having grooves for bush beading and top rail of hollow section 80x45mm .Lock rail of hallow section 115x45mm and bottom rail of hallow section 125x45mm with aluminium butt hinges of size 125mm, aluminium anodised handle 200mm long and aluminium floor door stopper, hydraulic door closer mortise lock 65mm,4 leavers and aluminium and glazing with selected quality tinted glass 4.8mm thick and rubber beading and aluminium beading and PVC bush beading complete all as specified and directed(Note- Thickness of aluminium section not less than 1.58mm and offrs designation / Room Name printed in glass). 2 Fabrication powder coated aluminium air tight sliding type window with AI box frame 65 x35x2 mm shutter with bottom and top rails of section 45x45x2 with 5mm thick selected quality tinted glass pan inclding rebated fixing builder hard ware and fitting springs, glazing clips rubber packing for air locking, anodised AI snap beading screw etc for fixing glass pane in frame shutters cover selected quality glass 5mm thick rubber packing including aluminium grill size of 75x75 mm cast type with aluminium beading, gasket etc complete and stailess steel wire mesh complete all as specified and directed. 3 10mm thick toughned glassglass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required,complete all as specified and directed. 4 Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty , complete all as specified and directed. 5 D type 150mm powder coatedaluminium handle for aluminum door, complete all as specified and directed. 6 Solid 14mm thick wood polymer composite louvers wall paneling (size 192mm x 2900mm x 14mm) fixed to walls with necessary clip, screw / adhesive complete all as specified and directed.NOTE : The wall paneling has to be in conformity with the existing wall paneling at site. Bidders ae requestd to visit the site before quoting their bid. 7 2mm thik PVC sheet fillet/ angle / beading of width 35mm for making frame for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing, complete all as specified and directed at site. 8 Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed 9 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 10 Rendering 10mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 11 Preparation of old plastered surfaces of walls and applying two coats of oil bound distemper overand including a coat of primer complete all as specified and directed. 12 Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper overand including a coat of primer, including 2mm thick (Average) wall care putty and sand papering complete all as specified and directed. 13 Anodised aluminium snap grid frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including dismantling ceiling board complete all as specified 14 4mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed. 15 Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) complete all as specified and directed 16 Coloured vitrified ceramic tiles, light shade,8-10mm thick (square ) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6,complete all as specified and directed. 17 All as per serial item No 16 hereinbefore but on skirting / vertical surfaces laid over and including 10mm rendering in cement mortar 1:4, compelte all as specified and directed 18 Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame,complete all as specified and directed. 19 Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. 20 Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete 21 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. 22 All as per serial item 21 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed 23 All as per serial item 21 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 24 All as per serial item 21 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor 25 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 26 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 27 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 28 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 29 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 30 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 31 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 32 LED lamp9 watts, B-22 type complete all as specified . 33 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 34 MCCB, 125 Amps, four pole, 3 phase , 36KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 35 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 36 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V completed all as specified and directed. 37 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 38 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB complete all as speicified and directed. 39 MCB, SPN, 240 volt,40 to 63 Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 40 SPN 32 Amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single pole and current carrying capacity in the MCB DB complete with connection testing and commissioning compelte all as specified and directed. 41 MCB, SP, 240 volt,40 Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 42 MCB ,SP, 240 volt, 6 Amps to 32 Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 43 32 Amp RCBOsfor earth leakage protection, overload & short circuit protection double pole 30mA complete all as specified and directed. 44 Surge protection device AC 2 Pole 20 to 40kA complete all as specified and directed. 45 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 46 LED panel recess mounted ultra slim 2x2 - 36 wattsultra slim (cool day) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fittingcomplee all as specified and directed. 47 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 48 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 49 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE FOR SERIAL ITEM NO 34, 35 & 36:(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 50 Supply and fixing sub main wiring with Four singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)Four runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 51 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . 52 25mm dia, rigid non metallic PVC concealed conduit, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed . 53 32mm dia, rigid non metallic PVC concealed conduit, ISI marked, inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed . 54 Round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, fixed as in repair complete all as specified and directed. 55 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mmand provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. 56 Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed. 57 Supply Installation, commissioning & testing LT Panel indoor type made out of 3.15mm thick steel and angel iron supports complete factor made plinth mounted, cubical type, dust and vermin proof, front back and sides openable duly provided with bus bar chamber, cables entry chamber, cabinets of suitable size for housing MCCBs metering cabinet for fixing voltmeter, ammeter and indicators lamp and painted with two coats of synthetic enamel paint (Powder coated )over one coat of red oxide primer and using copper bus bar of 250 Amps rating for phase and half of the rating of neutral duly fixed with suitable insulators and nuts and bolts comprising of the following incoming and outgoing feeder control complete all as specified and directed.(A) INCOMING :-(a)MCCB 250 Amps, 4 Pole, 35 KA -01 Nos(b)Voltmeter digital type 0 to 500 volts with selector switch – 01 No(c) Ampere Meter digital type 0 to 100 front operated Amp with selector switch – 01 No(d)Change over switch off load type 4 pole, 250 Amp – 01 No(B)OUTGOING(a)MCCB 200 Amps 4 pole 35 KA- 01 No(b)MCCB TPN, 25 KA, 160 Amp -01 No(c)MCB SPN 40 amp – 01 No 58 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter 59 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v)unit rate including protection pipe and GI strip 32x 6mm from top to earth plate upto 7.5 meter 60 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe pipes of pressure rating 6 kgf/sq. cm conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection, make as approved by Engineer-in-charge completeall as specified and directed 61 Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified, including taking down old unserviceable cable compelte all as specified and directed. 62 Supplying, installing and commissioning of split type air conditionerwith coolingfunction EER 3.2 of capacity 2TR, 05 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning,PVC pipe medium duty 25 mm dia for draining out condensed water,all as required including necessary electric connections, complete all as specified and directed.Note :- (i) Quoted rates shall deem to include the cost ofdrain pipe, copper tubing of requisite length and 4 sqmm multi standard copper cable, brackets, etc.(ii)Installation and commissioning to be done through OEM / itsauthorised service centre / agency. 63 Supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5.0 KVA complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 41660.0 /-
Tender Value
INR 20.83 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail