Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-09-2025 |
| 2 | 14-08-2025 | BOQ | BOQ | 25-08-2025 |
| Sl. No. | Item Description |
| 1 | B and R Division Items |
| 2 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed. |
| 3 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing complete all as specified and as directed. |
| 4 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed. |
| 5 | Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work complete all as specified and as directed. |
| 6 | Dismantling boarding any description fixed in any position with nails completeall as specified and directed. |
| 7 | Dismantling wall and ceiling boards (AC,fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. complete all as specified and as directed. |
| 8 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 9 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 10 | Dismantling rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed. |
| 11 | Taking down chokhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified and as directed. |
| 12 | Taking down chokhats or frame with shutters (without taking off shutters from frame) each exceeding 1.50 Sqm but not exe 4 Sq cm each complete all as specified and as directed. |
| 13 | Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 14 | Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 15 | Surface dressing n.exc. 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 16 | Excavating in post holes(or similar holes ) each n.exc. 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth round in layers n.exc. 25 cm in soft/loose soil complete all as specified & as directed. |
| 17 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified.Site clearance as in soft/loose soil complete all as specified and as directed. |
| 18 | Returning, filling in including spreading and levelling watering and well remming in layeres n.exc. 25cm thick complete all as specified and directed. |
| 19 | Removing excavated material not exceeding 50 meters & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 20 | Excavating in post holes(or similar holes ) each n.exc. 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth round in layers n.exc. 25 cm in soft/loose soil complete all as specified & as directed. |
| 21 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick ,spread, levelled ,rammed and consolidated to required gradient and camber with 0.2 to 0.5 tone hand roller including watering complete all as specified and as directed. |
| 22 | Use and waste Formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 23 | M&L for PCC 1:4:8type C2 using 40 mm graded broken stone as in foundation, filling and mass concrete complete all as specified and as directed. |
| 24 | M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub-bases for floors, complete all as specified and as directed. |
| 25 | M&L for PCC 1:3:6type C2 using 40 mm graded broken stone as in foundation, filling and mass concrete complete all as specified and as directed. |
| 26 | M & L for 75mm thickcement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement laid inpanels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 27 | M & L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregates) as in coping over walls, benching, etc. including neccessary formwork complete all as specified and as directed. |
| 28 | Material and labour for 40 mm thick Plain Cement concrete type B-1, P.C.C 1:2:4 (20mm graded aggregate) for base in floor fair and even without using extra cement complete all as specified and as directed. |
| 29 | Material and labour for providing Reinforced Cement Concrete 1:1.5:3 type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 30 | M&L Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6.00 mtr mean radius built in cement mortar 1:6 Complete all as specified and as directed. |
| 31 | M&L brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick wallin cement mortar 1:4 complete all as specified and as directed. |
| 32 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed . |
| 33 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or condrete surfaces in CM (1:4) & water proofing compound mixed with second layer (5mm thick) @ 3% finished fair and even complete all as specified and as directed.( Note -W.P.C. shall be measured and paid separetly . ) |
| 34 | M&L for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair without using extra cement complete all as specified and as directed. |
| 35 | M&L for rendering 10mm thick in cement mortar (1:6) on other than fair surfaces of PCC block / brick masonry wall / concretesurfaces, etc. finished fair and even without using extra cement complete all as specified and as directed. |
| 36 | Supply only integral water proofing compound complete all as specified and as directed. |
| 37 | M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding15mm thickscreed bed in cement mortar 1:6layingon floor complete all as specified and as directed. |
| 38 | M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including10mm thickbacking coat in cement mortar 1:4layingof skirting/dado on wallscomplete all as specified & as directed. |
| 39 | M&L of Glazed ceramic coloured tilesin vertical surface size 450mm x 300mm x6mm to 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls complete all as specified and as directed. |
| 40 | M&L in repairs for 18-20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 15mm thick screed in cement mortar (1:4) (rate shall be included) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab and taking off old damaged slab and disposing off complete all as specified and as directed. |
| 41 | M&L pre-polished chequered coloured paver tiles 25mm thick, area of each tile exceeding 0.06sqm but not exceeding 0.11sqm, in floors, set, jointed & pointed with neat white cement slurry mixed with pigment to match colour of tile, laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) (rate shall be included) complete all as specified and as directed. |
| 42 | Material and labour for 10mm dia and overTMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 43 | Material and labour for 6 to 8mm dia and overTMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 44 | Material and labourfor Mild steel TMT bars of Fe 500 or Fe 500D, 8 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 45 | S&F Framed worksuch as grills, gratings, etc.,with ends of bars shouldered and or riveted, or forged in to spikes;framed guard bars; similar work conforming to Fe 290 Gde E-165 completeall as specified and directed. |
| 46 | Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-210 complete all as specified and directed. |
| 47 | S & F rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc Fe 410W (Gde-E-250) quality \"A\" complete all as specified and directed by Engr-in-Charge. |
| 48 | S & F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachmentof Fe 410W (Gde-E -250) Quality \"B\" complete all as specified and directed by Engr-in-Charge. |
| 49 | Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made slidingbolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 completeall as specified and directed. |
| 50 | S & F Prepainted galvalume aluminium zinc coating steel based corrugated/semi corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof coverings/claddings to wall, fixed with self tapping screws, complete all as specified and directed. |
| 51 | S & F Prepainted galvalume aluminium zinc coating steel based plain steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof coverings/claddings to wall, fixed with self tapping screws complete all as specified and directed. |
| 52 | S & F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2020). |
| 53 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified. |
| 54 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 55 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified. |
| 56 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 57 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 58 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed. |
| 59 | Material and labour Second class hard wood as in 35 mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed . |
| 60 | S&FPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 61 | S&F Mortice lock, vertical type size 100mm, of brass 04 levers vertical type complete all as specified and as directed. |
| 62 | S&F300mm length of Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified. |
| 63 | Supply and fix 200 mm long aluminum anodised barrel tower bolts of extruded section completeall as specified and directed. |
| 64 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 65 | S&F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed. |
| 66 | Supply & FixedStainless steel wire cloth 0.36mm nominal dia of wire as in repair and average width of aperture 1.40 mmall as directed and specified. |
| 67 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane completeall as specified and directed. |
| 68 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane completeall as specified and directed. |
| 69 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square exc 0.5 sqm in each pane complete all as specified and directed. |
| 70 | M & L for 12 mm thick Prelaminated particle board,Exterior grade, prelaminated on bothside with decorative choice lamination & otherside balancing white lamination, complete all as specified and as directed. |
| 71 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic)in a grid of GI system duly suspended with 4mmdia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid all as specified and directed.Make:Everest Industries Ltd or equivalent as per IS 14862. |
| 72 | S&F 25 mm dia MS chromium platedcurtain rods with fixing side brackets end knobsand fixed with PVC rawl plugs & steel screwsetc complete all as specified and as directed. |
| 73 | Supply, lay and fix 15 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed. |
| 74 | Supply, lay and fix 20mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors. all as specified and directed. |
| 75 | Cuttinggrooves or rebates not exceeding 15 cm girth, and trimming with or without reinforced surfaces complete all as specified and directed. |
| 76 | Supply and fix, as in repair,vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and as directed. |
| 77 | Supply & Fixed inrepairsVitreous china wash down water closet pan ( pedestal pattern ) , whitewith P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 78 | Supply and fix in repairHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 79 | S & F in repairsPVC valveless,syphonic action type,low level PVC flushing cistren 10 ltr capwhite with flush pipe &all fitting and flush pipe complete all as specified. |
| 80 | S &F Soap Dish chromium Plated complete all as specified& as directed. |
| 81 | Supply and fix in repairs15 mm bore bib taps,chromium plated,cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 82 | Supply and fix in repairs15 mm bore pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe complete all as specified and as directed. |
| 83 | Supply and fix in repairs15 mm bore stop/angle valve,cast copper alloy,,screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions complete all as specified and as directed. |
| 84 | Supply and fix, asin repairs, 32 mm dia and 800mm long PVC flexible corrugated waste pipe for wash basin/sink complete all as specified and as directed. |
| 85 | S&F in repairs PVC connections 15mm dia size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 86 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fxed to wooden plugs with chromium plated brass screw and cup washer etc complete all as specified and as directed. |
| 87 | S&F in repair brass chromium plated tubular towel rail 20 mm dia 60 cm long, with fancy type brass chromium plated bracket on both sides and fixed with steel screws and wooden/ rawl plugs complete all as specified and as directed. |
| 88 | S&F for 110 mm dia PVC (SWR) pipes single socked in any length with rubberjoints, laid in trenches or in floor all as specified & directed. |
| 89 | S&F for 75 mm dia PVC (SWR) pipes single socked in any length with rubberjoints, fixed to walls complete all as specified and as directed. |
| 90 | M&L for 110mm PVC(SWR) bends fixed in pipe complete as specified and directed. |
| 91 | M&L for 75mm PVC(SWR) bends fixed in pipe complete as specified and directed. |
| 92 | Supply & Fixed PVC (SWR) vent cowl (75 mm) fixed in pipe complete as specified and directed. |
| 93 | M&L preparation of new wood or wood base surface of any description over 10cm width or girth applying two coats of synthetic enameled paint over one coat of pink primer complete all as specified and as directed. |
| 94 | M&L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 95 | Material & Labour for 1mm thick wall care putty over plastered surfaces and finishing even and smooth complete all as specified and as directed |
| 96 | Material and labour for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 97 | M&L for prepration of new or priviously untreated surface and applying two coat of oil bound distemper over a coat of primer on wall complete all as specified and directed. |
| 98 | Material and labour for preparation of old decorated plastered surface or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying two coats of Oil bound distemper using roller over a coat of primercomplete all as specified and as directed. |
| 99 | Material & Labour for for preparation of old decorated plastered surface or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 100 | Material & Labour for preparation of new plastered surface applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 101 | E and M Division Items |
| 102 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 103 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 104 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 105 | Taking out old U/s XLPE cable of any size/type taking out of olf bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 106 | Taking out old U/s GI PIPE of any size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 107 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- |
| 108 | One light point controlled by one switch. |
| 109 | One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 110 | One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 111 | One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 112 | M&L for point wiring with FRLS stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly with makig good surface for One 3/5 pin socket outlet 15 amps on the independent board complete all as specified and directed |
| 113 | M&L for point wiring with FRLS stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly with makig good surface for One 3/5 pin socket outlet 15 amps on the independent board complete all as specified and directed |
| 114 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 115 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 116 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 117 | S&Fswitch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 118 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 119 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 120 | M&L for submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC casing caping with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC casing caping will be measured as one length. |
| 121 | M&L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC casing caping with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 2.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC casing caping will be measured as one length. |
| 122 | M&L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC casing caping with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC casing caping will be measured as one length. |
| 123 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed. |
| 124 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 125 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 126 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook includingincluding taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed.Make- Crompton,Bajaj,Usha. |
| 127 | S&F plastic body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 128 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 129 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 130 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 131 | S&F MCB TPN of capacity 63 Amps 4 pole,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 132 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 133 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 134 | S&F MCB TPN of capacity 63 Amps 4 pole,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 135 | Returning, filling in trenches incl. spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 136 | Removing of surplus soil to a distance not exceeding 50 meter and deposited where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 137 | Supply and laying burnt bricks of sub-class \"B\" designation of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 138 | Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqdcover after punning down complete all as specified and directed. Note: Thickness of sand cushioning after punning down will be measured and paid separately. |
| 139 | M&L 100 mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 140 | M&L for steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 141 | Material & labour GI tube light grade 50 mm bore for protection ofcable complete all as specified and directed. |
| 142 | Material & labour GI tube medium grade 80 mm bore for protection ofcable complete all as specified and directed. |
| 143 | M&L for cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete |
| 144 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 145 | S&f Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 146 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make - Crompton Havells/M/S Jaquar & Company Pvt Ltd. |
| 147 | Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set (engine as per IS-10001/10002 and alternator as per IS-13364) of capacity 58.5 KVA, 415 Volts +/- 5% AC, 3 phase 4 wire, 50 Hz at 0.8 PF (lagging) at 1500 RPM complete with AMF panel with necessary protection & meters including sound proof canopy, including the following:-(A) ENGINE:- Engine shall be multicylinder four stroke (58.5 KVA), Radiator water/coolant turbo charged with mechanical governor with the following:-(i) Fuel level indicator.(ii) Fuel tank of capacity as per manufacturer\"s recommendation.(iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement.(iv) Exhaust manifold and residential type silencer.(v) Continuous 10% overload capacity in every 12 Hrs running.(vi) Self starting with and including maintenance free battery including charging circuit.(vii) Radiator with first fill of coolant.(viii) Turbocharger with continuous duty rating. |
| 148 | (ix) First fill of lub oil.(x) Coolant temp gauge, Lub oil, Pressure gauge, Tacho-cum-hour-meter.(xi) Engine spare parts list and maintenance manual - 03 copies.(B) ALTERNATOR:- 58.5 KVA, 0.8 PF (lag), 415 Volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with self regulated brushless self excitation & automatic voltage regulator with band of voltage regulation + 2.5% of rated voltage.(C) BASE FRAME:- Sturdy robust MS frame duly bolted, coupled, aligned, tested and housed within acosutic enclosure with anti-vibration pad.(D) ACOUSTIC ENCLOSURE:- It should be compact, modular construction and approved by ARAI (Nodal agency of CPRI) with the following:-(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition. (ii) Inside illumination shall be suitable as per manufacturer\"s design. |
| 149 | (E) AMF PANEL:- Inbuilt Gen set control & AMF Panel with microprocessor controller with engine safety protection & AMF Panel with suitable electrical & control fixture of auto start & stop, protection class IP-65, dust, weather proof and vermin proof duly powder coated after seven tank process, with electrolyte grade copper bus bar of 300 Amps capacity for three phase & neutral, with all standard switch gear such as power contactors of 250 Amps, relays etc. and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of the following:-(i) MCCB 415 Volts, 250 Amps, rating 4 pole 25 KA rupturing capacity, microprocessor based release for incoming supply overload, short circuit abd earth fault protection - 02 No.(ii) Ammeter 0-500 Amps, 96 x 96 mm square dial flush type ISI marked with selector switch 3 way - 01 Set.(iii) Voltmeter 0-500 Amps, 96 x 96 mm square dial flush type ISI marked with rotary selector switch 3 way - 01 Set.(iv) Phase indicator lamp (RYB) - 01 set.(v) Frequency meter digital type 45 to 55 Hz - 01 No.(vi) KWH meter 3 phase unbalanced load 1200 Amps capacity including CT coil - 01 Set.(vii) Auxilliary contacts.(viii) All standard relays circuits and protection required for automatic operation of GEN Set.(ix) Battery Charger.NOTE:- |
| 150 | (a) Any other accessories shall be provided as per manufacturer\"s recommendation and cost of the same deemed to be included in the quoted rate.(b) Cost of testing including arrangement of artificialload upto 110% of rated capacity, temporary arrangement of connecting cables, decibel meter and cost of fuel & testing material shall be deemed to be included in the quoted rate.(c) Construction of PCC foundation as per OEM design for mounting the DG Set including cost of necessary excavation and earth work in any type of soil shall be deemed included in the quoted rate. |
| 151 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. Note:Rate of under ground cable includes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc. |
| 152 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 153 | M&L in replacement for earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 154 | M&L for earthing with galvanised steel earth plate electrode600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level and connected to 32 x 6mm thick GI strip protected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternater layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of soil to a distance not exceeding 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed. |