| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 2 | Supplying and filling the basement with Good Earth filling in layers of not more than 15cmthick well rammed watered and compacted - etc., complete complying with standard specification. |
| 3 | Plain Cement concrete 1:4:8 using 40mm HBG metal for foundation, flooring including cost and conveyance of all materials at site and all labour charges for mixing, laying, tampering, compacting leveling and curing concrete and all other incidental charges such as denaturing if necessary complete Complying with std. specifications. |
| 4 | Supplying, fabricating and placing in position of mild steel and tar steel for all reinforced cement concrete works including cost and conveyance of steel and biding wire and all other labour charges for cutting, bending, tying grill charges for cutting, bending tying grill, straightening, welding charges and other incidental charges etc. complete complying with std. specifications. |
| 5 | Providing Centering, Strutting necessary strutting arrangements for the sides and softest for RCC column , slab, lintel, bed lock T & L Beams, staircase waist slab, landing material at site and all labour charges and other incidental charges etc. complete for 3m height and removing the same after the specification period as directed by the departmental officer etc complete as per standard specification. |
| 6 | WithoutStrutting : |
| 7 | WithStrutting : |
| 8 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - |
| 9 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using III class ground moulded bricks - 83/4” x 41/4” x 21/4” including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 10 | Plastering with c.m. 1:5-12mm Thick with good river sand including cost and conveyance of all materials from approved quarry including all labours for mining laying watering and all other incidental charges etc. complete as per standard specification. |
| 11 | Plastering with c.m. 1:3-10mm Thick with good river sand including cost and conveyance of all materials from approved quarry including all labours for mining laying watering and all other incidental charges etc. complete as per standard specification. |
| 12 | Supplying and fixing of rolling shutter by using new iron work Departmental officersincluding cost and conveyance ofincluding fixing charges for the same in position and all other incidental charges etc completed as per standard specifications. |
| 13 | Manufacturing supplying and fixing ofMILD STEEL Window made out of 40 x 40 x 6 mm M.S angle for outer frame, 35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets ( 18 G ) with 5Nos,of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase ofDouble shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. |
| 14 | Providing Granolethic floor finish in cement concrete 1:2:4 mix using 10-12mm ISS HBG metal to 50mm thick including cost and conveyance of all materials to site and all round charges for mixing, laying and curing etc., complete |
| 15 | Paving the Floor with scratch proof ceramic tiles of size 305x305x6mm finished thickness with c.m 1:3-20mm Tk and polished with same colorcement including all cost and |
| 16 | Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specificationsfor 10 sqm |
| 17 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 18 | Wiringwith2x1.5sq.mm.PVCinsulatedsinglecoreunsheathedFRLScopperconductorcableof1100VgradeinsuitablePVCrigidpipeonwallandceilingwithPVCaccessoriesandwithTWswitchboxand5AFTswitchwithpaintingofsuitablecolourwithcontinuousearthwireconnectionof1.5sq.mmcopperwireforopenPVClightpoint/fanpoint(for electronic regulator) (SD-16) |
| 19 | Supply and Fixing of 48” Ceiling Fan 5 Star Rated (without Regulator) including all Cost etc |