}

Tender For Construction Work Of Shri Annapurna Rishikul Brahmacharya Ashram Sanskrit Secondary School, Shivpur, Varanasi- Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5, varanasi-Uttar Pradesh

Rural Engineering Department has published Tender For Construction Work Of Shri Annapurna Rishikul Brahmacharya Ashram Sanskrit Secondary School, Shivpur, Varanasi- Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5. Submission Date for this Tender is 14-08-2025. Building Work Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50489521
Tender For Construction Work Of Shri Annapurna Rishikul Brahmacharya Ashram Sanskrit Secondary School, Shivpur, Varanasi- Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5
Tender
Indian
Uttar Pradesh
Varanasi
14-08-2025

Tender Documents

Tender Details

Tender For Construction Work Of Shri Annapurna Rishikul Brahmacharya Ashram Sanskrit Secondary School, Shivpur, Varanasi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for All kinds of soil.As per DSR:Vol.1:2023 item 2.8.1 2 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete,As per DSR:Vol.1:2023 item 2.25A 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).As per DSR:Vol.1:2023 item 4.1.8 4 Providing and laying in position, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.As per DSR:Vol.1:2023 item 5.1.2 5 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per DSR:(Vol.-1):2023 Item 5.2.2 6 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).as per DSR:(Vol.-1):2023 Item 5.3 7 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete as per DSR:(Vol.-1):2023 Item 5.9.1 8 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform as per DSR:(Vol.-1):2023 Item 5.9.3 9 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 10 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts as per DSR:(Vol.-1):2023 Item 5.9.6 11 Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges as per DSR:(Vol.-1):2023 Item 5.9.19 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR:(Vol.-1):2023 Item 6.1.2 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand):as per DSR:(Vol.-1):2023 Item 6.4.1 14 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and aboveplinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 15 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece.as per DSR:(Vol.-1):2023 Item 10.5.2 16 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per DSR:(Vol.-1):2023 Item 10.11.1 17 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per DSR:(Vol.-1):2023 Item 10.11.1 18 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 4.0 mm thick glass panes as per DSR:(Vol.-1):2023 Item 10.30.1 19 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.1.2 20 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.2.2 21 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) as per DSR:(Vol.-1):2023 Item 13.2.1 22 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement as per DSR:(Vol.-1):2023 Item 13.9.2 23 Making groove in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30 24 Making drip course in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30 25 Providing and laying Vitrified tiles in floor in Glazed vitrified floor tiles polished finish of size600x600mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. as per DSR:(Vol.-1):2023 Item 11.41A.2.1 26 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. as per DSR:(Vol.-1):2023 Item 11.39 27 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade as per DSR:(Vol.-1):2023 Item 8.31 28 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : as per DSR:(Vol.-1):2023 11.19.4 29 Distempering Two or more coats on new work with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre, as per manufacturers specification. as per DSR:(Vol.-2):2023 13.41.1 30 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 Ltr/10 sqm):. as per DSR:(Vol.-2):2023 13.47.1 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per DSR:(Vol.-2):2023 Item 13.80 32 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture as per DSR:(Vol.-2):2023 Item 13.48.3 33 Providing and fixing on wall face unplasticised 110mm dia Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per DSR:(Vol.-2):2023 12.41.2 34 Providing and fixing on wall face unplasticised - PVC moulded 110mm Coupler fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing withseal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.1.2 35 Providing and fixing on wall face unplasticised - PVC moulded 110mm Bend 87.5° fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.5.2 36 Providing and fixing on wall face unplasticised - PVC moulded 110mm BShoe (Plain) fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.6.2 37 Providing and fixing unplasticised -PVC 110mm pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. completeas per DSR:(Vol.-1):2023 12.43.2 38 S/F of Informatory Signboard at site 39 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A 40 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVCConduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 41 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 42 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 43 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 44 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 45 Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes. 46 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections,painting etc. as required. 47 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 48 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door 49 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 50 Double pole 51 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 52 Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes for pipe entryof the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work. 53 Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests 54 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 55 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Semi rigid pipe. 32 mm dia 56 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 57 Providing and fixing unplasticised PVC connection pipe with brass unions 15 mm nominal bore 58 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms. ( for sink) 15 mm nominal bore 59 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore 60 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 61 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 62 Providing & fixing soil, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 a) 100mm dia centrifugally cast iron S & S pipe. 63 b)75mm dia centrifugally cast iron S & S pipe. 64 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia 65 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 66 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm 67 Bend 87.5 degree 110 mm Bend 68 Shoe (Plain) 110 mm Shoe 69 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 70 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 71 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes 72 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes 73 25mm dia nominal outer dia pipes 74 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32mm dia nominal bore 75 Providing and fixing gun metal gate valve with wheel of approved quality.32mm dia nominal bore 76 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore 77 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Capcity in Per Liters 78 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 79 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded brick aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 80 M-150 brick work in 1:6 cement and coarse sandmortar in foundation and plinth including supply of all materials, labour and tools and plants etc required for proper completion of work. 81 R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 (1cement : 1.5coarse sand : 3stone ballast) in Slab, excluding supply of reinforcement and its bending with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. 82 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 83 Providing & Filling of O.B. brick ballast 25 mm to 40 mm size inside of upper layer in soak pit. 84 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 85 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded brick aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 86 M-150 brick work in 1:6 cement and coarse sandmortar in foundation and plinth including supply of all materials, labour and tools and plants etc required for proper completion of work. 87 R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 (1cement : 1.5coarse sand : 3stone ballast) in Slab, excluding supply of reinforcement and its bending with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work.Partition 88 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 89 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) (1:6) cement : c. sand 90 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 91 C.I. Pipe (100 mm dia) 92 C.I.cowel. 93 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg

Key Value

Document Fees
INR 3214 /-
EMD
INR 100000.0 /-
Tender Value
INR 49.99 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail