| 1 | S&F Single pointed Air Termination aluminium rod 12mm dia and 300mm long including necessary fixing arrangement including taking down existing complete all as specified and as directed. |
| 2 | S&F Aluminium Strip25 x 3.00 mm complete with saddle and fixing screw, epoxy insulators for roof or down conductor or fixed to pole or any other indicated situation for loop earthing etc, as required including making test point and testing complete all as specified and as directed. |
| 3 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm, drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal head screws with suitable enclosure made out of 3 mm thick CRCA sheet box complete all as specified and as directed. |
| 4 | M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtrsdeep below ground level) with top edge of the platenot less than 1.5 mtrs below normal ground level,connected togalvanised iron strip 32×6mm as earthing leadby means of bolts, nuts, check nutsand washers of galvanised iron or steel all as shownin electrical plate No 3 in SSR Part -I 2009 connected to eartingtest point all as specified complete withexcavation & earth work, PCC pit with 50mm thickRCC cover (grade M-15) having suitable handle(10mm MS Rod) 20mm dia GI pipe medium gradeISI marked watering pipe with GI funned with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth leadconductorcomplete all as specified and directed & testing on completion. |
| 5 | M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nutsand screws as specified type 410 SP-22, 8.5 metres long including erection, painting with two coat of synthetic enamel paint over a coat of red oxide or primer complete including taking down old unserviceable PCC/Steel Polecomplete all as specified and directed(Note Excavation earth work and PCC paid and measured seperately) |
| 6 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil complete all as specified and directed |
| 7 | Returning filling in including spreading, levelling, watering and well ramming in layers complete all as specified and directed |
| 8 | Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed |
| 9 | Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts complete all as specified and directedby Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose |
| 10 | Supply and lay burnt brick sub class ‘B’ of standard size laid in trenches as protection to cables complete all as specified and directed |
| 11 | Boring of holes under road, pavement, hard standing by trenchless technologytechnique for 40-80 mm dia pipecomplete all as specified and directed |
| 12 | Supply and fixing GI pipe light grade for cable protection , laid in trenches or fixed on pole/wallfor passing LT cables ofsizes40 mm dia including taking out old rusted pipe complete all as specified and directed |
| 13 | Supply and laying LT UG cable XLPE insulated heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 10 sq mm 2 core including taking out old unserviceable cable complete all as specified and directed |
| 14 | All as per item No 13 above but 16 sq mm 4 core |
| 15 | Disconnecting & Taking down unserviceable security light fitting/ flood light fitting of any type/specification complete from the any type of pole, high mastfor repair and replacement of burnt/worn out accessories where required, including repairs to u/s wiring, connection, minor spares like nut & bolt, connectors, screws, washers etc and reconnecting/refixing the same and testing complete all as directed.Note:- (i) Vehicle, ladder, tools & plants as required at site for repair/repalcement of light fittings shall be provided by the contractor at his own cost & arrangement.(ii) Spare required will be measured and paid separately under relevant schedule of items and only minor spares like nut & bolt, connectors, screws, washers etc deemed to be included in the quoted rate. (iii) Contractor will deposit new material/ spares at subdivision for acceptance of Engr -in-charge & further issue to contractors rep based on day to day complaints. |
| 16 | All as per item No 15 above but without taking down the light fitting from its position & tightening the fitting rigidly in postion after necessary repair/replacement of spares parts all as specified & directedby Engineer-in Charge. |
| 17 | All as per item No 15 above but taking down the post top lantern/Bollard/Garden light fitting of any type from Gates/GI poles etc. for repair and replacemnt of burnt/worn out accessories for repair or removing from site all as directed. |
| 18 | Supply onlyelectronic driver for LED street light, Post top lantern, Bollard/garden lights upto 30/35 watt of suitable size as per existing driver of light fittings completeall as directed.Note :-Driver should be as per existing size and make of light fitting. |
| 19 | Supply onlyelectronic driver for LED street light, Post top lantern upto 40/50 watt of suitable size as per existing driver of light fittings including taking down existing completeall as specified.Note :-Driver should be as per existing size and make of light fitting. |
| 20 | Supply onlyelectronic driver for LED street light, flood light upto 60/120 watt of suitable size as per existing driver of light fittings completeall as directed.Note :-Driver should be as per existing size and make of light fitting. |
| 21 | Supply only electronic chip/PCB plate with optical lens, suitable for LED Street light/ flood light/ post top lantern/ bollard/ garden light upto 30/35 watt capacity to make the light fitting serviceable completeall as specified and as directed. |
| 22 | Supply only electronic chip/PCB plate with optical lens, suitable for LED Street light/ flood light/ post top lantern 40 to 70 watt capacity to make the light fitting serviceable completeall as specified and as directed. |
| 23 | S & FLED Street light fitting 1 X 35/45 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting with suitable size PVC insulated wire ISI marked, including taking out the existing unserviceable light fitting complete all as specified and directed. |
| 24 | S & FLED Street light fitting 1 X 60/70 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting with suitable size PVC insulated wire ISI marked, including taking out the existing unserviceable light fitting complete all as specified and directed. |
| 25 | S & FLED Street light fitting 1 X 90 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting with suitable size PVC insulated wire ISI marked, including taking out the existing unserviceable light fitting complete all as specified and as directed. |
| 26 | S & FLED Flood light fitting 1 X 50/70 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting with suitable size PVC insulated wire ISI marked, including taking out the existing unserviceable light fitting complete all as specified and as directed. |
| 27 | S & FLED Flood light fitting 1 X 90/100 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting up with suitable size PVC insulated wire ISI marked, including taking out theexisting unserviceable light fitting complete all as specified and as directed. |
| 28 | S&FLED Flood light fitting 1 X 120 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting with suitable size PVC insulated wire ISI marked, including taking out the existing unserviceable light fitting complete all as specified and as directed. |
| 29 | S&F Dacorative Post top lantern for 360 degree direction of 40W LED IP 65 Protection, glare free and better uniformity with fixing accessories and connection complete all as specified and directed. |
| 30 | S&F LED Bollard light fitting 10W, powder coated housing with PC diffuser, IP 65 protection height not less than 600mm including fitting and fixing accessories and connection complete all as specified and directed. |
| 31 | S&F LED Bollard, Pyramid tripod type light fitting 10W, powder coated housing with PC diffuser, IP 65 protection including fitting and fixing accessories and connection complete all as specified and directed. |
| 32 | S&F in repairs of Aviation obstruciton Red colour LED lights fitting of 10 Watt in yellow painted die cast aluminium housing and fixing arangement with accessories on water tank/high towerincluding taking down the existing unserviceable. |
| 33 | Removing the existing unserviceable GI pipe bracket along with clamps and supply and fix GI pipe light grade bracket 32mm dia, 1.2m long bent to shape as required and fixed with suitable size of MS clamps,nut, bolt, washers etc to poles/walls complete all as directed. |
| 34 | S&F weather proofcable terminal boxfor outdoor installation of size not less then 205 x 255x 112mm including terminals with locking arrangments including necessary mounting arrangement of any steel tubular /RCC poles with suitable size of clamps nuts bolts washer etc. fixed with poles including one single pole MCB of capacity 6-32A and PVC connector for cable termination including removal of old unserviceable plastic cable terminal box all as directed all as directed |
| 35 | S&F wheather proof copper twin core cable of size 1.5 Sqmm drawn in and including UPVC conduit medium grade fixed to pole with suitable size clamps or fixing accessories incl. taking down old u/s complete all as specified and directed. |
| 36 | M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in platform, filling and mass concrete, coping to pole for embedding stay road all as specified, including necessary form work and applying two coats of white wash to exposed surface of coping/platform all as specified. |
| 37 | M&L for cement concrete type B2 1:2:4 using 40 mm graded aggregate for making good surfaces in pole foundation, stay concrete etcall as directed |
| 38 | S&F Timer distribution board/street light panel outdoor type as per standard specification and suitable size of capacity 32/40A, (Min Load Capacity 6 KW) 230 volt 3 pole with astronomical/digital time switch, contactor, MCBs and out going terminal with necessary mounting arrangement as per sample including taking down U/S panel complete all as specified and directed by Engineer-in-Charge. Note : height of the panel shoulld not less than 600mm from GL. |
| 39 | Supply and fix astronomical / digital timer switch 3 years 110 - 240 VAC suitable for controlled 3 Phase - 4 Wire 3 Channelincludingall necessary electrical connection in LT panelincluding taking down U/S timer switchcomplete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F triple pole contactor of capacity 40A of coil voltage of 415V AC with auxillary contact arrangement of having 2 NO (Normally open) + 2 NC (Normally closed) including taking down U/S contactor complete all as specified and directed by Engineer-in-Charge. |