| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-08-2025 |
| Sl. No. | Item Description |
| 1 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Two or more coats |
| 2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 3 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. |
| 4 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 5 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 7 | Re-lettering with black Japan paint of approved brand and manufacture. |
| 8 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. With cement mortar 1:4 (1cement: 4 coarse sand). |
| 9 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 10 | Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. |
| 11 | Providing and applying multicoat synthetic plaster as per approved design, pattern texture in 3 mm thick on new plastered surface finished in proper line and level as directed by Engineer-in-charge in five coats consisting of composition of four order of application given as under includig all materials, labour Tools and Plant etc.1) Scrapping of the new surface and applying sealer primer mixed with water in the ratio 1:3 (part sealer primer : 3 part water) and applying by brush @ 0.25 kg/sqm.2) Applying levelling coat of spectrum rustic fine or equivalent with trwel as a putty finished to generate required texture by trowel.3) Applying third coat of synthetic plaster with trwel @ 2.5 kg/sqm finished to generate required texture by trwel.4) Applying two coats of exterior super fine pigmented acrylic wall coating as top coat @ 0.5 kg/sqm in two coats and colours as approved by Engineer-in-charge all up to a height of 10m |
| 12 | Repairing and Maintenance of cupboard doors by replacing hinge handle lock towel bolt etc. as per site condition and fixing of new door by similarmaterial whereever required as per instruction and direction of E-in-C ( Total 20 flat and in one flat three cupboard of size 1.2Meter x 3 Meter). contractor is requested to visit and access site condition |
| 13 | Pest control by Anti terminate treatment of approved chemical as per BIS 6313 2022 and process adopted for existing buildings including drilling hole, injection chemicals, sealing holes by white cement, spraying in walls etc. complete in approved quantity and dilution of chemicalas per instruction and direction of E-in-C ( total floor area of per flat is around 110.0 sqm includingcommon space) contractor is requested to visit and access site condition |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Providing and fixing Ist quality ceramic glazed wall tiles of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm ,including pointing in white cement mixed with pigment of matching shade complete. |
| 16 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 17 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes 110 mm diameter |
| 18 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm |
| 19 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermalexpansion.Single tee with door 110x110x110 mm |
| 20 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. ----12.42.4 Single tee without door -110 x110 x110mm |
| 21 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermalexpansion.110 mm bend 87.5 |
| 22 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion.110 mm shoe |
| 23 | Providing and fixing on wall face unplasticised - PVC pipe clips of approvd design to unplasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarsed sand ) and making good the wall etc complete.110 mm clips |
| 24 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 25 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 26 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 27 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 28 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 29 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 30 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge. |
| 31 | In cement mortar |
| 32 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 33 | For thickness of tiles 10 mm to 25 mm |
| 34 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : |
| 35 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe |
| 36 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical meansincluding stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 37 | 15 mm to 40 mm nominal bore |
| 38 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal ofunserviceable materials within 50 metres lead. |
| 39 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping groundwithin 50 metres lead. |
| 40 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 41 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :610x460 mm bowl depth 200 mm |
| 42 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of E-IN-C |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 44 | Flexible pipe 40 mm dia |
| 45 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 5 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall50 mm nominal outer dia Pipes |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.25 mm nominal dia Pipes |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makinggood the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.32 mm nominal outer dia Pipes |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40mm nominal outer dia pipes |
| 50 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 51 | 45 cm length20 mm nominal bore |
| 52 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 53 | Cutting holes up to 30x30cm in walls including making good the same 18.76.1 with common burnt clay F.P.S. (non modular) bricks |
| 54 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 55 | For pipes 100 to 250 mm diameter |
| 56 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 57 | The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 58 | Providing and fixing C.P. brass angle valve angular stop valve with wall flange MAKE SOMANY /JAGUAR /Kohler/Hindustan for basin mixer and geyser points of approved quality, 15mm nominal bore including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 59 | Providing and fixing two way bib cock with wall flangeMAKE SOMANY / JAGUAR / Kohler/Hindustan complete as per instruction of E in C including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C(KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 60 | Providing and fixing Square Jali-150 mmof make as specified of approved qualityas per instruction of E-in-C |
| 61 | Providing and fixing unplasticised PVC moulded fittings / accessories for unplasticised Rigid soil and waste pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10 mm gap for thermal expansion. Cowel MR-110 mm |
| 62 | Providing and fixing unplasticised PVC moulded fittings / accessories for unplasticised Rigid soil and waste pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10 mm gap for thermal expansion.P-Trap 110 X 110 |
| 63 | Providing and fixing white vitreous water closet wall mount with wall support mounting, clamp, and all other required acessories for connecting flush pipe with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 64 | Providing and fixing soft close lid in white vitreous water closet wall mount with, clamp, and all other required acessories with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 65 | Providing and fixing Hand shower (Health fauchet) brass with flexible tube upto 1.5 metre longincluding all fiitings etc completeas approved by Engineer - in - charge MAKE Kohler/ Hindustan/SOMANY/JAGUAR |
| 66 | Providing and fixingtowel rail 60 cm complete with brackets fixed tocleats with CP brass screws with concealed fittings arrangement of approved quality and colourMAKE Kohler/ HindustanSOMANY/JAGUAR 600 MM LONG as per manufacturer specifications (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 67 | Providing and fixingMetropole flush Valve 32 mm size (Concealed body)(3.0 liters/6.0 liters per flushing)1.5\" make SOMANY/ JAGUAR/ Kohler/Hindustan as per manufacturer specification and direction of engineer incharge. (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 68 | Brick work with chimny brick ofsuperstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 69 | Providing and fixing shower arm 15\" wall mounted with flangeMAKE SOMANY/JAGUAR/ Kohler/ Hindustan CP Brass as approved by Engineer in charge of quality & make including cutting and makinggood the walls and floors wherever required as per manufacturer instructions and direction of E-in-C (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 70 | Providing and fixing rain showerMAKESOMANY/ JAGUAR/ Kohler/Hindustan CP Brassof quality& make as approved by Engineer in charge including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 71 | Providing and fixing CPVC valve 50mm dia to existing pipeline near water tank |
| 72 | Providing and fixing brass female thread brass elbow FABT to angle cock/bib cock other fitting in15 mm dia with all accessories fittings and fixutres complete as per direction and instructon E-in-charge. |
| 73 | Providing and fixing brass FABT to Metropole push valve/ other fitting in32mm dia with all accessries fittings and fixutres complete as per direction and instructon E-in-charge. |
| 74 | Providing and fixing brass MABT to push vale/ Divertor/ other fitting in40mm dia with all accessries fittings and fixutres complete as per direction and instructon E-in-charge. |
| 75 | Providing and fixingbrass FABT to push vale/ other fitting in40mm dia with all accessries fittings and fixutres complete as per direction and instructon E-in-charge. |
| 76 | Providing and fixing brass female trade brass FABT to push vale/ other fitting in50mm dia with all accessries fittings and fixutres complete as per direction and instructon E-in-charge. |
| 77 | Providing and fixing brass male trade brass MABT to push vale/ other fitting in50mm dia with all accessries fittings and fixutres complete as per direction and instructon E-in-charge. |
| 78 | Providing and fixing CPVC tank nipple 50mm dia to existing water tank in water supply as per instruction and direction E-in-C |
| 79 | Providing and Fixing Epoxy based Putty/ M seal including cutting, scraping, finishing of pipe etc. complete as per instruction of E in C |
| 80 | Providing and fixing C.P. brassswan neck bib cock with wall flange MAKE SOMANY/JAGUAR/KOHLER/HINDWARE for kitchen sink of approved quality, 15mm nominal bore including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C (KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 81 | Providing and fixing CP Brass Soap Dish Holder Dual having concealed fitting arrangements |
| 82 | Providing and fixing CPVC UNION 50mm dia to existing pipeline near water tank |
| 83 | Providing and fixing Brass Ball cock of approved quality and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 84 | Providing and fixing pillar cock withMAKE SOMANY / JAGUAR / Kohler/ Hindustan complete as per instruction of E in C Including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C(KINDLY REFER TO ORIGINAL EQUIPMENT MANUFACTURER CATLOUGE FOR RESPECTIVE MODLE AND MAKE AS APPROVED BY E-IN-C) |
| 85 | Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for patam in window sills, door sills, ventilator sillsfacias and similar locations in walls of thickness .20 cm of required size to hold door of size 0.9mx2.1m ,approved shade, colour and texture by suitable adhesive/cement mortar , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish, making hole for door aldrop etc. complete at all levels. ( for door size 0.9mx2.1 m) including dismantling chowkhat and making good the same |
| 86 | Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for patam in window sills, door sills, ventilator sillsfacias and similar locations in walls of thickness .20 cm of required size to hold ventilator of size 0.75M x0.5M, in approved shade, colour and texture by suitable adhesive/cement mortar , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish,etc. complete at all levels. ( for ventilator of size 0.75M x0.5M) |
| 87 | Removing and Refixing and fixing Wall Mixer with hot and cold water supplywith all necessary fittings, fixures and acessoriescomplete including keeping mixer in custody and refixing as per instruction of E in C Including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C |
| 88 | Removing and Refixing and fixing wash basin with pillar cock and connecting to water supplywith all necessary fittings, fixures and acessoriescomplete including keepingin custody and refixing as per instruction of E in C Including cutting and making good the walls and floors wherever required as per manufacturer instructions and direction of E-in-C |
| 89 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. . Size of Tile 600 x 600 mm |
| 90 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm |
| 91 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 92 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 93 | Of area 3 sq. metres and below |
| 94 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 95 | Of area beyond 3 sq. metres |
| 96 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 150 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 97 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 150 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 98 | Providing and fixing 16 mm thick granite, mirror polished,premoulded and prepolished, machine cut for plateform,of required size,approved shade, black colour and texture laid over pink marble 16 mm thickjoints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish . |
| 99 | Providing and fixing 16 mm thickpink marble ,premoulded and prepolished, machine cut for kitchen platforms,of required size,approved shade, colour and sandwitched withpink marble 16 mm thick in vertical partition for kitchen plateformjoints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels. |
| 100 | Providing and fixing over cabinet in exiting structure of kitchen ofwithdoors of required size and other fittings likehandles locks, etc. as needed and High-Density High Moisture Resistance (HDMR ) plyboard 16 mm and mica 1mm on front and balancing lamination 0.75mm on back and fitting of make hettich/ hafle/ blum.The over cabinet of the platform will be made of ply board with mica on top with fitted with hinges including all fittings and fixtures etc. complete.as required as per site requirement and instruction and decision of E-in-c.for any query related to this item site visit may be done and E-in-c may be contacted if required. |
| 101 | Providing and fixing under cabinet withdoors of required size andbaskets for modular kitchen which include Preforated Cutlery Basket 100 mm Thali Basket SS 200mm and Plain wire basket 150 mm including teliscopic channels other fittings likehandles hinges magnetic latchetc. as needed inEdges in framing with butt hinges, latch, handle and fitting of standard make.The shelves ofunder cabinet of the platform will be made of High-Density High Moisture Resistance(HDMR) ply board 16mm with mica 1mm on top with fitted with support for storageincluding all fittings and fixtures etc. complete.as required as per site requirement and instruction and decision of E-in-c. For any query related to this item site visit may be done and E-in-c may be contacted if required. |
| 102 | Dismantling Pelmets including removing brackets and leveling the wall by putty etc to give smooth finish and dumping all useless material to Dumping ground or place as decided by E-in C |
| 103 | Providing and fixing brackets in SS to hold pipe of 25 mm dia for curtains |
| 104 | Providing and Fixing SS Pipe 25 mm dia medium guage including cutting in required size and filing sharp edges along with suitable endcaps in door, windows, partitions and other required places as per instructions and location decided by E-in-C |
| 105 | Providing and fixing Multilayer Ply Blockboard based Door 30 mm thick of sixw 2.1 Meter x1Meter approx with including fixing in chowkhat in Butt Hinges and withSS Fittings like aldrop 10ïnch, handle 6 Inch, latch, towerbolt 8 Inch and 0.75 mm Mica on both sides in desired colour and pattern as directed by E-in-C |
| 106 | Labour for Cleaning, glass, door,window floor etc. including labour and material for cleaning etc. complete( 20 quarters / flats = 20 job per flat) |
| 107 | Labour for shifting of fridge, cupboards , desk, cabinets and other household items etc. by packers and movers with packing shifting etcupto of lead of 5 km as per direction and Instruction of E-in-C. ( 20 quarters / flats and toandfro 20x2=40 job per flat) |
| 108 | Providing and fixing door and windows in Powder coated Alumunium sectionincluding glazing and fly proof mesh ect in three track including removing old z -section window bysuitable means and fixing frame in existing opening including fixing wiremesh in doors/window and fixing by suitable means as per site condition in frame with slider lock/ latch ect complete.handles,hinges, etc all fittings and fixtures as requiredand desired by E-in-C. |
| 109 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 110 | 3 x 1.5 sq. mm |
| 111 | 3 x 4 sq. mm |
| 112 | 6 x 4 Sq. mm |
| 113 | 2 X 10 sq. mm + 1 X 6 sq. mm |
| 114 | Supplying and fixing of following sizes ofmedium size PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 115 | 20 mm |
| 116 | 25 mm |
| 117 | 32 mm |
| 118 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 119 | 5/6 A switch |
| 120 | 3 pin 5/6 A socket outlet |
| 121 | 6 pin 15/16 A socket outlet |
| 122 | TV antenna socket outlet |
| 123 | Bell push |
| 124 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 125 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 126 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 127 | 1 or 2 Module (75mmX75mm) |
| 128 | 3 Module (100mmX75mm) |
| 129 | 6 Module (200mmX75mm) |
| 130 | 8 Module (125mmX125mm) |
| 131 | 12 Module (200mmX150mm) |
| 132 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 133 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 134 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections etc. as required. |
| 135 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing- Switch - DP - 1 Way - with Indicator & Water Heater Marking - 2 Module including connections, painting etc. as required. |
| 136 | Supplying and fixing of ding dong type call bellsuitable for single phase, 230 V, AC supply with remote switch including connection testing etc. as required. |
| 137 | Supplying and fixing 6 Module GI box with modular plate and cover in front on surface or in recess, including providng and fixing 1 no. 3 pin 5/6 A modular socket outlet and 1 no. 5/6 A modular switch, 1 no. 6 pin 15/16 A modular socket outlet and 1 no. 15/16 A modular switch,connections etc. as required. |
| 138 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 139 | Supplying, Installation, testing & commissioning of size 250 mm sweep fresh air fan (Ventillation fan) in PVC body inbuilt louvers / shutter in the existing opening i/c making the hole to suit the size of the above fan with making good the damages i/c connection as reqd at site. |
| 140 | Supplying, Installation, testing and commissioning of wall mounted 400 mm sweep, oscillating type for wall mounted fans suitable for operation 230 V AC supply complete with regulator along with taken by double string etc as required. |
| 141 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) |
| 142 | 12-15watt |
| 143 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sinkof aluminum housing such that LED junction temperature shall not riseabove 90°C). |
| 144 | 18- 22 watt |
| 145 | Supplying, installation, testing and commissioning of prewired LED /fluorescent/ compact fluorescent light fitting of alltype complete with all accessories and tube etc. on ceiling/wall including connection with3 x 1.5 sq. mm FRLS PVC insulated copper conductor wire etc. as reqd.(Light fitting shall beapproved by Engineer-In-Charge before procurement and its shall be in company catalogue and price list with BIS CERTIFICATION) |
| 146 | Surface & Wall mounted LED batten 2 Feet LED mirror light fitting, 10 watt with minimum 1100 lm/W system efficacy, extruded aluminum housing provide for efficient heat dissipation with poly carbonate diffuser & integrated electronic drivehaving PF>0.95 and IP20, THD < 10%,CRI> 80 complete with electronic driver, 50000 hrs burning for lifetime etc. as required. (Make- Havells cat No. LUMILINEPLUSPROBS10WLED865SPCWHINDor similar specification Philips /Lighting Technology/Regent Lighting) |
| 147 | LED outdoor wall light/Bulkhead ,IP 65, 6.5 watt,700 lumens,4000k, minimum system efficacy of 105 lm/W, pressure die cast alumunium body,50000 burning hours,IK-7-8 rating,,P.F.>0.9, THD<20%, SDCM<5,diffuser-PC,surge protection 2.5 KV,complete etc as required (Philips cat no-WT 140 W LED 7S-NW PSU S1 PC or equivalent inPhilips / Lighting Technologies/Havells) |
| 148 | Fancy type Wall bracket light fitting single head having Premium opal glass for reduced glare and metallic body for glass stand and holder with 10-12 W, 240 V LED lamp complete with connection and testing etc. as requierd. |
| 149 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg 1.16 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025 14 to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) |
| 150 | 70 watt |
| 151 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 152 | 16 Way, Double door |
| 153 | Supplying and fixing following amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 154 | Single Pole (5-32 AMP) |
| 155 | Double pole (32Amp) |
| 156 | SITC of autoclean filter less chimney having external oil collector tray to collect oil & grease particals,1200 m3/hr,60 cm in size, 1.5 Watt Lamp, Auto off function etc. as reqd. |
| 157 | Supplying, installation, testing & commissioning of cubical outdoor type free standing totally enclosed dust & vermin proof feeder pillar suitable for 415V, 3 Phase , 50 Hz AC supply system of suitable size with 400 mm depth fabricated in compartmentalized made from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates with requiredon 35x35x5mm angle iron and leg of 35x35x5mm of 50 cm on ground level front openable & suitable size brick work padestal with plastering, i/c cleaning & finishing complete with 7 tank process with powder coating in approved shade, having 300 Amp capacity extensible type four pole Aluminium Alloy bus bars of high conductivity with PVC sleeves, DMC/SMC bus bar supports, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections,entire panel shall have a2 Nos common G.I. earth bar of size 25 mm x 5 mm all around the LT Panel with 2 Nos. earth stud, solid connection from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 Sq. mm PVC insulated copper conductor cable, cable alley,busbar chember cable gland plates,i/c providing following switch gears:- (Size of panel should not be less than 1.65 Sq. Mtr. & depth 0.4 mtr.) |
| 158 | (Incoming)-(i) 200 Amp 4 Pole, MCCB, having breaking capacity 25 kA, Thermal Magnetic, with over load and short circuit setting (Ics = 100% Icu) with spreader links and extended rotary handle. - 1 No. (ii) 3 Nos. Phase indication LED lamps with protection MCB, - 1 Set(iii) Danger Plate shall be 200 mm X 150 mm of mild steel -1 No. (iv) Digital type Volt meter with selector switch (v) Digital type Ammeter with selector switch (vi) CT\"s-400/5 Amp-3 Nos., Bus Bar :- Electrolytic high conductivity TPN aluminium bus bars of minimum of 300 Amps capacity suitable for 415 V, 3Phase, 50 Hz AC supply-100% neutral with heat shrinkable coloured sleeves and i/c DMC/SMC bus bare cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. -1 Set, (i) 63 amps4 pole MCCB having breaking capacity 25 KA at 415 volt 50 Hz AC (Ics=100% Icu) with thermanl magentic release and adjustable over load and short circuit protection complete with phase barrier, spreader link, extended operating rotary handle confirming to IS / IEC - 60947-2 etc as reqd. -6 Nos. |
| 159 | Dismelting and reinstallation of outdoor panel with completed reconnection, End terminals, cables joints if required, support withheight of 0.75 m from ground level 35x35x5mm angle iron and leg of 35x35x5mm front openable & suitable size brick work padestal with plastering, i/c cleaning & finishing complete etc as required |
| 160 | Supplying,installation, testing and commissioning of indoor type cubical Panel Board of suitable size fabricated from 2 mm thick MS sheet compartmentalised totally enclosed, floor/Wall mounted with 35 mm x 35 mm x 6 mm angle iron base frame having glass/acrylic sheet cover for meter sighting windows, higed gasketted front cover with locking arrangements i/c having provision for mounting the accessories in individual compartment i/c supply and fixing the following with connections, inter connection by 6.00 sq mm PVC insulated FRLS copper conductor wire earthing, painting,numberingetc. complete as required. (Size of panel must not be less than 1.00 Sq. mtr. and depth should be not less than 300 mm i/c loose wire box at top) |
| 161 | Incomer :-a) 63 Amp 4 Pole, 25 KA MCCB thermal Magnetic release (Ics = 100% Icu) - 1 No. b) 100 Amp 4 Strip PVC sleeved, Aluminium Bus Bar of Suitable length-1 Set Outgoing a) 32 Amp SPN MCB \"C\" Curve-10 KA-4 Nos. b) 16 Amp SPN MCB \"C\" Curve-10 KA-1 No. C) Space for single phase Energy meter-4 Nos |
| 162 | Supplying,Installation, Testing & commissioning of Single Phase, 2 wire energy meter mounting on existing meter panel suitable for 5-30 Amp., directbased metering for connection etc completed as reqd. |
| 163 | Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 164 | 3½ x 50 Sq. mm |
| 165 | Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/Loose Loop as required. |
| 166 | 3½ x 50 Sq. mm |
| 167 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 168 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 169 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface /recessed sondui /submainwiring cable as required |
| 170 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 171 | 3½ x 50 Sq. mm (35 ,mm) |
| 172 | Providing & installation of maintenance free chemical earthing with the help of GI earth electrode 3 Mtrs. Long fabricated by encapsulating 2 Nos. 65 X 6 mm GI strip primary earth electrode in B class GI pipe of 88 mm outer dia. As secondary electrode, sealed at bottom with solid conical GI base seal. The earth electrode has to be vertically driven into the rocky soil earth in 7 inches dia. hole of 3.7 mtrs. depth. The entire earthing is to be enclosed at the top with masonry chamber of size 450 mm X 450 mm made up of modular bricks of class designation 35 & also provided with square shape 300 mm cover of 6 mm thick MS sheet with frame. The vertically driven electrode to be filled with conductive 2 bags of 25 Kgs. each advanced grade earthing compound mixed with black cotton soil complete as required. |
| 173 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 174 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 175 | Dismantling of existing electrical installation inType-D Residential qtrs., which include dismantling of old light fixtures, ceiling fan, call bell, MS switch boxes, switches, sockets, etc. but without dismantling of wiring. |
| 176 | Dismantling of existing energy meter cum main distribution board,feeder pillar located ground floor of type-D qtrs block |
| 177 | Credit the cost of following dismantled electrical material received from site under buy back system |
| 178 | 1200 mm ceiling fan |
| 179 | 4 Feet floucent tube light fitting |
| 180 | Wall bracket fitting |
| 181 | Lamp holder |
| 182 | Exhaust fan 300mm/200 sweep |
| 183 | 6 Amp Piano type switch |
| 184 | 16 amp Piano type switch |
| 185 | 6 amp piano type socket |
| 186 | 16 amp piano type socket |
| 187 | Fan regulator |
| 188 | MS boxes of assorted size |
| 189 | 12 Way MCB DB with existing MCBs of assorted of size |
| 190 | Energy meter cum main distribution box comprising 4 Nos electronic energy mete, MCBs etc. |
| 191 | Feeder pillar of type-D Qtrs. Block comprising MCCBs of assorted of sizes. |
| 192 | 6 Amp, Light plug |
| 193 | Call bell |
| 194 | Bell push |
| 195 | Mirror light |
| 196 | 16/15 amp Power plug |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy