Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Work :-Removing white wash or colour wash by steel wire brushing and / or scrapping sand preparing and reparing the wall surface smooth including necessary repairs to scratches etc. complete.Spec.No.: As directed by Engineer in charge |
| 2 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. As directed by Engineer in charge |
| 3 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. Note : Following items to be executed As directed by Engineer in charge |
| 4 | Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 5 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc |
| 6 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 7 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 8 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 9 | Removing cast iron or wrought iron or A.C. pipe or G.I Pipe and stacking them as directed with all leads, lifts etc. complete. |
| 10 | Removing cement or lime plaster including disposing of the spoils as directed with all leads, lifts, complete.Spec : As directed by Engineer In Charge |
| 11 | Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. |
| 12 | PCC WorkProviding and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC WITHOUTSCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed) |
| 13 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 14 | Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 15 | Providing, filling and compacting Siporex Block Filling in the Sunken areas all as directed. |
| 16 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC WITHOUTSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed ) |
| 17 | Providing and laying Cement Concrete ware coat as Flooring 80 mm thickwith 1:2:4 cement concrete(M15)laid to proper level and slope in alternate bays, including compaction, filling joints, finishing smooth with extra cement in any colour as directed , making grooves as per architectural drawing and curing complete. |
| 18 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 19 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. Complete. A) Flooring |
| 20 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of sizeSize of Tile1200 x 1200 mm |
| 21 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 22 | Providing & Fixing in position, Carpetmore than 800+ gsm, made with 100% stain proof FR grade fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge. |
| 23 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherevernecessary, curing, etc. complete. |
| 24 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. |
| 25 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 26 | Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. |
| 27 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen daysscaffolding etc.complete |
| 28 | Providing and applying lustre finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. Spec. No.: As directed by Engineer in charge |
| 29 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. |
| 30 | Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. |
| 31 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding,preparingthe surface.(excluding the primer coat)etc. complete. |
| 32 | Providing and applying priming coat on concrete/masonary/Asbestos Cement plastered surfaces including scaffolding if necessary,preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matter and sand paper in gas requiredetc.complete |
| 33 | Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting, scaffolding etc. complete. |
| 34 | Providing and applying melamine polishof required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polishing, scaffolding if required etc. complete. Spec: As directed by engineer in charge |
| 35 | Providing & applying exterior emulsion Paint of APEX grade of Asian Paints or equivalent quality/ approved makes/ approval make for the external walls after necessary surface preparation and applying one coat of primer having atleast 50% white cement content & curing for atleast 3 days period and then applying three coats of exterior emulsion paint. The item shall include scafolding, cleaning etc complete.Spec. As directed by engineer incharge.Materials to be used as per approved make list. |
| 36 | Providing and filling crack filling material to conealed existing crackat any location by Dr. Fixit crack filler |
| 37 | Furniture and Misc. Work Heavy duty fully upholstered mid back Auditorium Chairs with writing tablet 570/580 mm c to c tip-up type. total height 970 to 1030 mm. having following specifications: Powder Coated Heavy duty MS Stand. Moulded Polyurethane Foam cushion. PU foamdensity 48 – 52 kgs/cu m. Moulded Polyurethane Foam manufactured in certified ISO 9001 facilityto ensure consistency in density for longevity. Upholstered in Foam laminated stretched sandwich FR grade Fabric for clean finish and soft comfortable feel as per the colour & pattern selected by the client. Seat bottom and rear of Back having moulded synthetic protective cover. Wooden or PU armrestof required size & length. Mounted using Chemical fasteners. Along with Seat & row numbers in auto glow. Godrej Jupiter, Pen-workers PW04/ 05, TSI layric, Wipro symphony as approved by engineer In-charge |
| 38 | Window Blinds - Providing and fixing Rolling Blinds of approved make & shade with Blackout fabric& telting with chain(Ball)system with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-charge prior execution of work) Spec. No: - As directed by Engineer in charge . Brands- D Décor, MAC,Johnson |
| 39 | UPVC Fixed double glazed window Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter. 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2, 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C, 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2, 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2, 5 Mean Breaking Stress for welded corner, (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2, (b) For the compression bending test Shall not be < 30N/mm2, 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %, 7 Surface Spread of flame BS : 476 - Part 7 Classification 1, 8 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable, 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa, 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa, 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. A) 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47 mm |
| 40 | Providing and fixing of factory made uPVC casement window / Fixed Window & Casement Door (White Colour) comprising uPVC multi-chambered frame, Sash, & Mullion with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter. 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2,2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C, 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2, 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2, 5 Mean Breaking Stress for welded corner, (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2, (b) For the compression bending test Shall not be < 30N/mm2, 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %, 7 Surface Spread of flame BS : 476 - Part 7 Classification 1, 8 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable, 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa, 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa, 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. A) Casement Window (Big Series) frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm |
| 41 | Acoustics & Interior Providing & Fixing in position, Acoustical Panelling made from FR grade Fabric wrapped Compressed polyester fibre nonwoven 9mm panels on, 50 x 50 mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm FR grade synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects, as directed by the engineer in charge. (part of auditorium side & rear walls ) fabric base rates 450/ sq m following work is to be done at any floor and all heights |
| 42 | Providing & Fixing in position, Acoustical Ceiling made from Gypsum Plain Panels on approved heavy duty G.I. frame ceiling channels at 450 c to c, & intermediate channels not more than 1200 c to c, along with ply wood formssuspended with Hangers from Roof, in front of 1000 Gsm FR grade synthetic wool 50 mm thick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge. (part of auditorium ceiling) |
| 43 | Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra(Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid backed with 1000 GSM FR Grade Synthyetic wool 50 mm thick. The tiles should haveHumidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, ColourWhite, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x600 x 15mm , suitable for Green Building application, with Recycled content of 66% GWand 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T -section flanges colour white having rotary stitching on all T sections i.e. the Main Runner,1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carryingcapacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The TSections have a Galvanizing of 90 grams per M2 and need to be installed with Suspensionsystem The Tile and Grid system used together should carry a 10 year warranty. The T-Grid system should be of Silhouette type with Black groove. product approved as per GRIHA and BS 476 etc. complete |
| 44 | Wooden Partitions full height - Providing & Fixing in position 75mm thk.+/- 2 mm wooden partition, including 50x50mm Salwood frame work and covering with12mm. ply & 1.0 mm. thk laminate on both sides, insertion of T.W. member whereever necessary, cutting of holes to partition, provision for electrical conduits,laminate covering of approved colour & shade, providing additional angle supports wherever necessary for standalone partitions and additional strengthening wherever necessary,all as per details provided in drawing. |
| 45 | Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600mm c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge. |
| 46 | Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1mm laminateon, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm FR grade synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge. |
| 47 | Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm FR grade synthetic wool 50mm thick and 3mm Tecsound from both sides, 6mm promate fire board, 12mm waterproof ply & 1 mm laminate from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.)4 no each leaf,with Door-closer (Dorma / Geze or eq.)including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design, including all the necessary fixtures, InstructionsComplete in all aspects as directed by the engineer in charge (Door should match 1 Hr fire rating) |
| 48 | Providing & Fixing in position, Podium made from 18mm wp plywood, laminate from out side & polish inside asper given drawing & Instructions, Complete in all aspects as directed by the engineer in charge.All specificatation and sizes as per drawing. |
| 49 | Providing and fixing in position a table of size 600 mm x 2000 mm, per the approved drawing and instructions of the Engineer-in-Charge. The table top shall be made from 50 mm thick BWP plywood, finished with 1 mm laminate on the top surface and teak wood edge profile duly polished. The sides and front panels shall be made from 25 mm thick plywood, laminated on the outer surfaces and polished from the inside. A footrest box shall be provided, made from 25 mm thick plywood, finished with laminate externally and polished internally. All exposed edges shall be finished with teak wood lipping, The item shall be completed in all respects, including cutting, fixing, polishing, edge finishing, and hardware installation, using materials of approved quality and as per the detailed drawing and specifications. |
| 50 | Audio and Video work (Providing, Supplying and Installing)Providing, Supplying and Installing Line Array Speaker: Frequency Range (-10 dB) :41 Hz – 18 kHz ; Nominal Impedance: 8Ω ; HF Transducer : 2\"compression driver ; Frequency Response (-3 dB)¹ : 70 Hz – 14 Hz; Max. SPL/1m (calc)²: 134dB ; Coverage: H: 90°;Vertical coverage: 40° ; LF Transducer : 15\" ;Sensitivity 1 W/1 m : 101dB; Power handling: 500 W continuous . |
| 51 | Providing, Fixing Mounting/hanging arrangements for above speaker cluster |
| 52 | Providing and Fixing Passive loudspeaker for Stage Monitors: Frequency Range (-10 dB) :55 Hz - 20 kkHz; HF Transducer :1-inch titanium compression driver; Speaker Type:Full-Range, two-way ; Frequency Response (-3 dB)¹: 82 Hz - 18 kHz ;Max. SPL/1m (calc)² : 131dB; Coverage (H x V): 90˚ x 60˚;LF Transducer: (12 in) ;Power handling: 350 W continuous . |
| 53 | Providing and Fixing Power Amplifier: Dual channel power amplifier; Power output per channel: 900W @8Ω, 1700W @4Ω; V- Bridged Power: 6000W @4Ω; THD+N: < 0.05%; Frequency response: 10Hz – 21kHz; S/N ratio: 109dB; Built in DSP function ; Crosstalk : < -80 dB ; Input Impedance :20 k Ω . |
| 54 | Providing and Fixing Mixer: Mixing channels : 16 Line Inputs (8 mono and 4 stereo) ;GROUP : GROUP Bus, FX Sends ;Mic inputs :Mic inputs ; Phantom power : 48V phantom power per channel; Line inputs : |
| 55 | Providing and Fixing Podium Microphone : Frequency response: 50 Hz to 20,000 Hz ;Output impedance, 1 kHz: 200 ohms ;Sensitivity: 1 kHz: 5.6mV/Pascal ;Dynamic range: >101 dB ;Power requirements:Phantom, 12 - 52 VDC . |
| 56 | Providing and Fixing Wireless Handled Microphone:Number of Channels: 32 ;Modulation: ± 40 kHz ; Frequency Response: 80 Hz – 18 kHz ± 2 dB ;Balanced Output: 20 dBV ; Unbalanced Output: Adjustable 8 mV to 0.755V RMS ;Signal-to-Noise Ratio: > 100 dB A-Weighted ;Dynamic Range: > 95 dB . |
| 57 | Providing and Fixing Head worn Microphone: Receiver Type: Synthesized PLL ;Number of Channels: 32 ;Modulation: ± 40 kHz ; Frequency Response: 80 Hz – 18 kHz ± 2 dB ;Balanced Output: 20 dBV ; Unbalanced Output: Adjustable 8 mV to 0.755V RMS ;Signal-to-Noise Ratio: > 100 dB A-Weighted ; Dynamic Range: > 95 dB . |
| 58 | Providing and Fixing General Microphone: Frequency Response, Close: 30 Hz – 17 kHz; Frequency Response, Far: 70 Hz – 17 kHz; Maximum SPL: >140 dB ; Impedance: 350 ohms balanced (low-z) ; Microphone Connector: 3-pin, XLR-type . |
| 59 | Providing and Fixing Microphone Stand long type |
| 60 | Providing and Fixing Speaker Cable:2 conductor 14 AWG stranded, twisted, and unshielded cable, Insulation: Semi-rigid polyvinyl chloride;Jacket: Polyvinyl chloride. |
| 61 | Providing and Fixing Mic Cable: 2 conductor 22 AWG stranded, twisted, and shielded cable; Insulation: Semi-rigid polyvinyl chloride; Jacket: Polyvinyl chloride. |
| 62 | Providing and Fixing Equipment Rack: 32U Equipment Rack for housing all rack mountable equipments with internal wiring, front glass door; heat dessipation fans; power distribution units etc. |
| 63 | Video SystemProviding and Fixing Projector :Brightness 6,000 Lumens; ANSI lumens: 6,000 ;Contrast ratio :4,000,000:1; Dynamic contrast :6,000:1; Resolution :WUXGA (1920 x 1200) ; Signal input :Standard: HDMI x 2; DVI-D x 1 (Digital only) ;HDBaseT (RJ45 x 1) ; Control & networking :RS232 In ;Signal output:HD15 x1. |
| 64 | Providing and Fixing Mounting/Hanging arrangements for above projector |
| 65 | Providing and Fixing Motorised Projection screen tab tensioned of 150\" having aspect ratio of 16:10 |
| 66 | Providing and Fixing HDMI - HDMI 02 M cable |
| 67 | Providing and Fixing HDMI cable 20 m |
| 68 | Providing and Fixing Connectors and patch cables |
| 69 | Installation & Commissioning of Audio Visual System |
| 70 | HVAC Work Including SUPPLY & INSTALLATION,TESTING & COMISSIONING OF AIR CONDITIONING SYSTEMS as follows Ductable A.C. 5.5 tr with R410 GasInverter |
| 71 | Installation of Supply and return G.I. Ducting --Rectangale Ducting 22 G |
| 72 | Installation of supply & return G.I DuctingRectangale Ducting 24 G |
| 73 | Installation of Supply and return G.I. Ducting -- Flexible Canvas connection for Machine |
| 74 | Installation of Supply and return G.I. Ducting --Al. Powder coated Supply & Return Grill |
| 75 | Installation of Supply and return G.I. Ducting -- Al. Volume Control Damper for supply |
| 76 | Thermal InsulationDuct Accoustic insulation 9 mm |
| 77 | Duct Thermal Insulation 9 mm nitryle rubber |
| 78 | Refrigerant PipingRef. Piping with Copper Tubing & NitryleFoam insulation-Hard piping |
| 79 | ElectricalElectrical Cabling Between Control Panel, Outdoor & Indoor Units with Control wiring4CX1.5 Sq.mm |
| 80 | Drain PipingDrain water piping 1 1/2inch |
| 81 | M.S.StandM.S Stand for Indoor Units |
| 82 | M.S Stand for outdoor Units |
| 83 | GasAdditional Gas R 410 |
| 84 | Intallation,Testing&Comissioining of ACUnits including Pressure Testing,Vaccum Testing,GasLifting, Shifting of Indoor units Ductable |
| 85 | Intallation,Testing&Comissioining of ACUnits including Pressure Testing,Vaccum Testing,GasLifting, Shifting of outdoor units Ductable |
| 86 | Intallation,Testing&Comissioining of ACUnits including Pressure Testing,Vaccum Testing,GasInstallation Indoor & Outdoor Ductable 5.5 tr |
| 87 | Electrical WorkPoint wiring for light / bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW (light pt -2 Nos.) As per note no-1 on page no. 23, for point wiring above 6 meters of length of, add 10% of overall rate of point wiring for every additional 1 meter ength or part there of. |
| 88 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 89 | Point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-HW ( All other areas except Toilet)(Light Pt-12 Nos) |
| 90 | Point wiring for ceiling fan hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVC conduit / casing n caping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no.WG-HW . (With modular plate & Box) |
| 91 | Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring onnections complete..(Fan-10 Nos.) |
| 92 | Wiring for plug on board with switch socket surface / concealed type, copper wiring and earthing and with modular accessories as per specification no. WGPW/ CW (con plug - 5 Nos. ) |
| 93 | Point wiring for independent plug in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW. |
| 94 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete.(P/PP-2Nos) |
| 95 | Supplying and erecting modular type switch 16/20 A with indicator on provided plate and box with wiring connections complete.(P/PP-2Nos) |
| 96 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (Power plug-2Nos) |
| 97 | FIRE ALARM SYSTEM & CCTV SYSTEM:-Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC (for Camera ) |
| 98 | Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/S |
| 99 | Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 100 | Supplying, installing, testing and commissioning hooters with CRCA enclosure complete as per specification no. FFFAAS/HT |
| 101 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 102 | Supplying, installing, testing and commissioning of 2 Zone Microprocessor based, conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, complete as perspecification no. FF-FAAS/FACP (2 Zones . ) |
| 103 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 104 | Supplying & erecting of High definition 2 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS, Video Resolution : minimum 1920 x 1080 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 30m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 30m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 105 | Supplying, installing, testing & commissioning of 8/10 Ch. Network Video Recorder (NVR), suitable for 2 MP cameras only with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920x1080.Support H.265 or higher, H.264, MJPEG,Incoming Bandwidth 80Mbps with minimum 2 SATA Hard Disks,ANR Technology,2 SATA interfaces for 2 HDDs and capacity of each HDD up to 8TB,minimum 02 USB port, Alarm I/O 4/1, RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,support multi brand network Cameras,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc complete as per specifications no. CCTV-NVR |
| 106 | Supplying & erecting 2TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 145MB/Sec to 180MB/S. Drive bay supported 08, Cameras supported up to 64, Cache (MB) 64, Load/Unload Cycle -3000000, Work Load Rating per Year180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD for Recording and backup upto 72hrs. |
| 107 | Supplying & erecting 32\" professional LED Monitor with 1920*1080 (Full HD) Display, suitable for 16 channel NVR and following features Brightness: minimum 250 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC, USB, Audio In, Built-in speakers maximum 2 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 108 | Supplying and fixing PoE adaptor to provide DC supply to ethernet devices as per specification no. WG-NAS/PEA |
| 109 | Supplying, fixing, and configuring 8-ports 1 GE un-managed gigabit PoE switch compliant with IEEE 802.3 standards, min. 120W PoE capacity with 2GE SFP uplink erected in provided rack complete |
| 110 | Supplying, fixing, and configuring broadband router with all accessories on provided rack. (Networking Switch) |
| 111 | WIRING MAINSSupplying & erecting mains withFRLSH, flexible copper PVC insulated wire of following size, 1.1KV grade with ISI mark laid with suitable & apropriate size of conduit / trunking / inside pole/ wall / Busbars or any other places.Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid insuitable conduit/trunking/ inside pole/Bus bars or any other places (Extra Long Point wiring for lights & fans) |
| 112 | Supplying & erecting mains with 2 X 1.5 Sq.mm.& earth wire 1.5 sq.mmFRLSH copperPVC insulated wire laid insuitable conduit/trunking/inside pole/Bus bars or any other places.(forDB to SB-100 mtr) |
| 113 | Supplying & erecting mains with 2 X 2.5 Sq.mm.& earth wire 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG MA/BW (for power plug) |
| 114 | Supplying & erecting mains with 4 x1.5 sq.mm & earth wire 1.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (If required) |
| 115 | Supplying & erecting mains with 4 X 4 Sq.mm.& earth wire 2.5 sq.mmFR copperPVC insulated wire in HMS PVC conduit min.25 mm dia.as per specification No.WG-MA / PC,para. no.1.4.1.(if required) Double the rate of (1-3-3/5)+ half rate of2x 2.5 sq.mm wire ( 1-3-2/5)+(1-2-4/3) ( for DB -5mtr) |
| 116 | Supplying and erecting HMS PVC conduit 25 mm dia.with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 117 | Supplying and erecting HMS PVC conduit 32 mm dia.with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 118 | Cable & ExcavationSupplying, erecting & terminating FR XLPE insulated, galvanised steel wirearmoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (LDB, PDB incoming Cable) |
| 119 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wirearmoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU(AC DB to OD Unit) |
| 120 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipeas per specification no. CB-LT/CU(AC DB incoming) |
| 121 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no. CB-LT/AL(Main incoming Cable) |
| 122 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. (Aprox. Main incoming Cable upto Main DB from Exsiting point of Supply) |
| 123 | FITTINGS:-Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years .(18W Square- 4 nos ) |
| 124 | Supplying and erecting LED square / circular Max. 25 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 125 | Supplying LED concealed type foot / step light with aluminium body for indoor / outdoor application suitable for 4W - 6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with minimum 1 year warranty as per specification No. FG-IDF/LED. |
| 126 | Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED.(15W Circular-4Nos) |
| 127 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1400 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8, PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in positionas per specification no. FG-FN/CF. |
| 128 | DISTRIBUTION BOARDSupplying & erecting triple pole and neutral distribution board (TPNDB), 3 poleMCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron / GIframe (vertical busbar type) as per specification no. SW- WR/MCBDB1 (As main incoming DB) |
| 129 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TPMCBs total 4 ways/12 Poles, with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB.( AC DB) |
| 130 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB.(LDB- 1 No. & PDB 1 No) |
| 131 | Supplying,erecting & marking SP MCB 6A to 32A, C-series with rated short-circuit breaking capacity (Icn) 10 kA in provided distribution board as per specification no. SW-MCB |
| 132 | Supplying, erecting & marking TP MCB 6A to 32A, with rated short- circuitbreakingcapacity(Icn) 10 kA in provided distribution board as per specification no.SW-MCB |
| 133 | Supplying, erecting & marking TP MCB 40A to 63A, with rated short- circuitbreakingcapacity(Icn) 10 kA in provided distribution board as per specificationno.SW-MCB |
| 134 | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixedmagnetic setting with provided leads, provision for installation of shunt / UV / trip alarmcontact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, noline-load bias in provided enclosure/panel as per specification no. SW-MCCB ( Rate converted to 4 Pole MCCB) |
| 135 | Supplying, erecting & marking FP MCB 6A to 32A, with rated short- circuitbreaking capacity (Icn) 10 kA in provided distribution board as per specification no.SW-MCB(LDB,PDB Incomer) |
| 136 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short- circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB (AC DB Incomer) |
| 137 | EARTHING :-Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI( for DB-2 No) |
| 138 | Supplying & erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with neccessory copper clamps fixed on wall / cable/ conduit with screws in an approved manner. (8 SWG) (0.1155 x20 Mtr.= 2.31 Kg for DB ) |