Tender For Renovation Of Staff Quarters Type-Iii (6 Nos) F-32 To F-37 And Type-Ii (29 Nos) G-53 To G-81 At Csir-Ceeri, Pilani.; 1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to floor V level : 2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 4 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 7 Thermo-Mechanically Treated bars of grade Fe-500D or more. 8 Brick work in superstructure of class designation 7.5 bricks above plinth level and below plinthupto floor V level inc.m. 1:6(1 cement: 6 coarse sand) 9 Cement mortar 1:6 (1 cement : 6 coarse sand) 10 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 11 Cement mortar 1:4 (1 cement :4 coarse sand) 12 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. including dismantling of existing kota stone slab with mortar and preparation of surface etc complete 13 Granite stone slab of all colour and texture Area of slab over 0.50 sqm 14 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 15 Granite work 16 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 17 Providing and fixing Ist quality ceramic glazed wall tiles (Size not less than 300 mm x 450 mm) conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades (light,dark and designer etc ) of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand),having below rough plaster of average 20 mm of 1:4 ( cement :4 coarse sand) for surface preparation and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 18 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including dismantling of existing door etc complete 19 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 20 Providing and fixingS.S. 304pipe curtain rods with SS brackets of best quality 21 20 mm dia (heavy type) 22 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat 23 Fixed to steel windows by welding 24 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete 25 Size 300x16 mm 26 250x16 mm 27 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete 28 Size 250x10 mm 29 Size100x10 mm 30 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 31 Size 125 mm 32 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment). 33 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 34 Providing and fixing T-iron /angle iron frames for doors, windows and ventilators chajjas of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 35 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 36 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 37 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete including dismalting of exiting one as required. 39 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 40 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 41 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 42 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 43 40 mm thick with 20 mm nominal size stone aggregate 44 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete 45 Providing and laying Vitrified tiles with spacer in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness including grouting of joints (Payment for grouting of joints to be made separately). The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily including levelling of existing floor with cement mortar 1:3 (1 cement : 3 coarse sand) upto average 40 mm thick as required and including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge 46 Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm 47 Providing and laying Vitrified tiles with spacer in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm and including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge 48 Size of Tile 600x600 mm 49 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) with water proofing agent as per standard, withmaking chasing including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design including chasing and dismentling existing gola and disposal of malba within CEERI campus etc. complete. 50 In 75x75 mm deep chase 51 20 mm average outer cement plaster of mix : including proper double scoffolding system and fibre mesh of 150 mm width at joints RCC and bricks or as required 52 1:4 (1 cement: 4 coarse sand) 53 15 mm cement plaster on rough side of single or half brick wallof mix, including proper double scoffolding systemand fibre mesh of 150 mm width at joints RCC and bricks or as required 54 1:4 (1 cement: 4 coarse sand) 55 20 mm cement plaster of mix finished with a floating coat of neat cement of mix 56 1:4 (1 cement: 4 coarse sand) 57 Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand) with water proofing agent as per statndard including raking out joints. 58 Flush/ Ruled/ Struck or weathered pointing 59 Interior finishing (A) Removing dry or oil bound distemper, water proofing cement paint and even for cement plaster surface the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (B)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (C)Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coatsto achieve even shade and colour including water thinnable priming coat with cement primer etc complete 60 Two or more coats 61 Exterior Finishing :- (A) Removing dry paint,lime white wash,exterior paint and even for cement plaster surface the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (B) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade including proper double scoffolding system 62 Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm 63 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 64 Two or more coats on new work 65 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 66 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre 67 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade 68 Two or more coats on old work 69 Providing and fixing bright finished SS304 hard drawn hooks and eyes : 70 Size 150 mm 71 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. 72 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within CEERI campus lead) as per direction of Engineer-in-Charge. 73 Internal Work- Exposed on wall 74 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with stainless steel 304 hinges with screws,etc. as required and proper closing,locking system by sawing , chiseling,plaining, tightening, hammering , welding etc with new nails/screws all complete as per the direction of the Engineer-in-charge. 75 Demolishing cement concrete Nominal concrete 1:3:6 or richer mix and brick work in cement mortarmanually/ by mechanical means including disposal of material within CEERI Campusand proper cleaning, levelling & dressing the dismolished surface as per direction of Engineer-in-charge as per direction of Engineer - in - charge. 76 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete andRepairs of reveals and jambs of doors andwindows with cement mortar 1:3 (1 cement :3 fine sand) including chiseling the damagedarea anddisposal of material within CEERI Campusas per direction of Engineer - in - charge 77 Of area 3 sq. metres and below 78 Of area beyond 3 sq. metres 79 Dismantling C.I. or asbestos rain water/waste pipe with fittings and clamps including stacking the materialwithin CEERI Campusas per direction of Engineer - in - charge 80 75 to 80 mm dia pipe 81 100 mm dia pipe 82 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within CEERI Campusas per direction of Engineer - in - charge 83 Up to 150 mm diameter 84 Dismantling of gully chamber of carious sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within CEERI campus including refilling the excavated area as per Direction of Engineer-In-Charge. 85 Dismantling old plaster & tiles with plaster or skirting/ terrazzo in dados/ tiles,Kota stone etc. raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within CEERI Campus as directed by engineer in charge. 86 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations , stacking serviceable and unserviceable material separately including cutting reinforcement bars disposalwithin CEERI Campusas per direction of Engineer - in - charge 87 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 88 In cement mortar 89 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 90 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 91 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm Hubless centrifugally cast iron P or S trap, 10 litre low level ISI white P.V.C. flushing cistern, including flush pipe, long pvc bend with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 92 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 93 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level ISI white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 94 W.C. pan with ISI marked white solid plastic seat and lid 95 Providing and fixing wash basin with C.I. brackets and dash fastner, 15 mm C.P. brass pillar basin mixer with central hole and long braided hoses , 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : 96 White Vitreous China Wash basin size 550x400 mm with C.P. brass pillar basin mixer with central hole and long braided hoses 97 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, waste coupling ,with C.P. brassSink mixer with swinging casted round shape spout wall mounted with connecting legs and wall flanges including painting of fittings and brackets, cutting and making good the walls wherever required and dismalting of existing sink safely as per direction of Engineer-In-Charge. 98 Kitchen sink without drain board 610x510 mm bowl depth 200 mm 99 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. 100 Semi rigid pipe 32 mm dia 101 Providing and fixing mirror of size 600x450 mm superior glass (of approved quality) and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing, fixed to wooden cleats with C.P. brass screws and washers complete. 102 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 103 Providing and fixing soil, waste and vent pipes : 104 100 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 105 75 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 106 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete 107 100 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 108 75 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 109 Providing and fixing plain bend of required degree. 110 100 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 111 75 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 112 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 113 100x100x100x100 mm mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 114 75x75x75x75 mm dia Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 115 Providing and fixing terminal guard 116 100 mm Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 117 Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 118 100 mm dia SS 304 grade coupling with EPDM rubber gasket 119 75 mm dia SS 304 grade coupling with EPDM rubber gasket 120 Providing and fixing Steel finished clamps with base holder plate with accessories etc complete for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 121 100 mm dia 122 75 mm dia 123 Providing and fixing P-trap / Floor trap of self cleansing design with screwed down or CP hinged grating with frame with or without hole, vent arm complete, including cost of cutting and making good the walls and floors : 124 100 mm inlet and 100 mm outlet Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 125 100 mm inlet and 75 mm outlet Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 126 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls and floor etc. Internal work - Exposed on wall including synthetic enamel paint of approved brand and manufacture of required colour to give an even shade 127 15 mm dia nominal bore 128 20 mm dia nominal bore 129 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 130 15 mm dia nominal bore 131 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling ,including painting with anti corrosive bitumastic paint and connection with main line with fillings,Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work etc complete 132 20 mm dia nominal bore 133 Providing and fixing Brass Ball Valve with operational handle of approved quality (screwed end) 134 20 mm nominal bore 135 Providing and fixing uplasticised PVC connection pipe in SS finishwith brass unions : 136 45 cm length & 15 mm nominal bore 137 Providing and fixing C.P. brass shower With Shower Arm & Wall Flange of 15 or 20 mm inlet ofapproved quality and design as per direction of Engineer - in - charge 138 100 mm diameter 139 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 140 15 mm nominal bore 141 20 mm nominal bore 142 Providing and placing on terrace (at all floor levels) polyethylene water torage tank,IS: 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with 03 nos tank nipples and the base suppport for tank & including providing and fixing 20mm dia ball valve (brass) of approved quality, High or low pressure, with plastic floats complete for each tank.including taking down existing pvc tank & deposited in store yard as per direction of Engineer in-Charge. 143 Providing and fixing C.P. brass bib cock with wall flange of approved quality conforming to IS:8931as per direction by Engineer in charge. 144 15mm nominal bore. 145 Providing and fixing C.P. brass long body bib cock of approved quality 146 15mm nominal bore. 147 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 with wall flange as per direction by Engineer in charge 148 15mm nominal bore. 149 Cutting holes up to 30x30 cm in walls including making good the same: 150 with common burnt clay F.P.S. (non modular) bricks 151 Providing,laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints including trenching , refilling anddismalting of existing old SW pipe etc.complete : 152 100 mm diameter S.W.pipe 153 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 154 100 mm diameter S.W.pipe 155 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight FRP/GRPcover with frame of 300 x300 mm size (inside) the load capacityof cover to be not less than 12.5T as per standard design: 156 150 x 100 mm size P type without common burnt clay F.P.S (non modular ) bricks of class designation 7.5 157 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 158 For pipes 100 to 250 mm diameter 159 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 160 Refixing old G.I. pipes complete with new G.I. fittings and clamps, i/c cutting and making good the walls etc with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade15 to20 mm dia nominal bore internal work -exposed on wall 161 Dismantling EWC/Indian WC with cisternand fittings including depositing in store as per directed by Engineer-In-Charge 162 Providing and fixing CP Brass Towel railof size 600mmx20mm with brackets fixedto wooden cleatsetc. complete of approved quality and makeas per direction of Engineer-In-Charge. 163 Providing and fixing 35mm thick panelled / glazed shutters for doors and window frames made of hollock wood/shisham wood and 12mm thick water proof ply paneling/SS wire gauge 0.63mm dia & aperture 1.40mmm as per the design existing in the colony including SS butt hinges, screws and removing the old shutters and depositing as per direction of Engineer-In-Charge. 164 Providing and fixing 8 mm dia C.P. brasshealth faucet (hand shower) with flexible ss finished tube upto 1 metre long with necessary fittings to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 165 Providing and fixing C.P. brasswall mixer with provision for overhead shower with 115mm long bend pipe on upper side,connecting legs and wall flanges including all fittings of approved quality conforming to IS:8931 of quality and make as approved by Engineer - in - charge. 15mm nominal bore. 166 Providing and fixing C.P. brass pillar basin mixer with central hole and long braided hoses with wall flanges including all fittings of approved quality conforming to IS:8931 15mm nominal bore. 167 Providing and fixing MS window handles with washers, nuts & bolts etc. Complete as per direction of Engineer-In-Charge. 168 Repair of existing broken RCC cornersof chajjas, railings, projected areas, shelves,nosing of staircase steps by chiseling the existing surface,removing of loose materials andrepairing the same with cement concrete 1:2:4 withfibre mesh of 150 mm width at jointsas required,plastering with Cement mortar 1:4and finishing as per existing as per direction of Engineer-In-Charge. 169 Chisselling the flaked and cracked RCC slabs ceiling plaster and replastering the same in c.m. 1:3(1 cement:3 coarse sand) of sufficient thickness to cover the exposed reinforcement with fibre meshas required and make the ceiling smooth including finishing as per existing as per direction of Engineer-In-Charge. 170 Providing and fixingKota stone slab without base including making 75x75mm chases and making good with c.m. 1:3(1 cement: 3 coarse sand) etc. complete. 18-25mm thick as per direction of Engineer-In-Charge. 171 Repairs of reveals and jambs of doors andwindows with cement mortar 1:3 (1 cement :3 fine sand) including chiseling the damagedarea and disposal of Malba in low layingarea in CEERI Campus as per direction of Engineer-In-Charge. 172 Providing and fixing CP brass 100mm dia grating ( hole or without hole)with frame in bathroom, kitchen and wash-basindrain including removing the old CI/CP gratingand making good the floor after fixing the new one as per direction of Engineer-In-Charge. 173 Taking down PVC tanks of 500.00 ltr capacity and including refixing the same complete after proper cleaning of the tankwith new 20 mm brass float valve and tank cover if broken to be deposited CEERI Store yards per direction of Engineer-in-charge 174 Taking out sinder from sunken floor of toilet including proper stacking including refilling the same with proper campaction as per direction of Engineer-in-charge 175 Take down White Vitreous China Wash basin with fittingsand refixing the same wash basin after proper cleaning with new C.I. brackets,dash fastners,new 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required 176 20 mm cement plaster on roof including of mix 1:4 (1 cement: 4 coarse sand) including admixed with water proofing compound conforming to IS : 2645and laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry upto 300 mm on all round wall height (gola is not paid extra in this item)and making pattern of 300x300 mm square 3 mm deep grooving. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test and preparartion and cleaning of existing surface with wire brush etc complete as per direction of Engineer-in-charge 177 Providing and fixing 19 mm thick block board ,best quality including 4mm thick teak wood beading all round of each shutter with wooden frame of hollock wood/shisham wood in required size all round work and piano hinges stainless steel,Hasp& staple for locking arrangement , backing or studding with screws etc. Complete as per direction of Engineer-In-Charge. 178 Providing and fixingmanhole cover with water tight FRP/GRPcover with frame of 455x610 mmsize (inside) the load capacityof cover to be not less than 12.5T as per standard design of approved make including rising of manhole upto 450 mm with brick work,plaster and slab casting as per standard parameter as discribed and dismaltling of existing oneetc complete finishingas per direction of Engineer-In-Charge. 179 Part B Electrical Work:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable including fibre mesh to cover the chases etc. as required. 180 Group B (Irrespective of any length) 181 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 182 Supplying and fixing two module 180 watt stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 183 Supplying and fixing following size/ modules, GI box alongwith modular base, cover & blankingplate for modular switches in recess etc. as required. etc as required. 184 1 or 2 Module (75mmX75mm) 185 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 186 5/6 amps switch 187 3/5 Pin, 5/6 amp Socket 188 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduitmaking good including fibre mesh to cover the chases where as required. 189 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 190 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 191 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 192 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 193 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 194 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 195 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 196 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 197 3 x 2.5 sq. mm 198 3 x 4 sq. mm 199 Supplying & Fixing of following sizes of steel conduitalong with heavy duty accessories, junction box etc. in surface / recesse including painting in case of surface conduit, or cutting the wall, repair and making good the same including fibre mesh to cover the chasesas required. 200 20 mm 201 25 mm 202 32 mm 203 Supplying & fixing5 to 32 Amp. 240/415 Volts, 10KAC curve, MCB for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 204 Double pole 40 amp 205 Single pole 10 to 32 Amp 206 Supplying and fixing 40 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 207 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 208 P & F of heavy duty capacitor start Exhaust fan Size-300 mm sweep, 900 RPM, single phase, IS: 2312 marked ofapproved make in existing opening including grouting of metal fastener with bolts, nuts making connections , testing etc. as reqd. 209 P & F of gravity louver shutter of superior quality made out of frame of 18 SWG MSsheet & louvers made from 24 swg Al. sheet with nut bolts enamel paint etc as required. Size Up to 380mm. ( for 200 mm and 300mm Exhaust Fan) 210 P & F of capacitor start Exhaust fan Size-200 mm sweep,1350 RPM, single phase, IS: 2312 markedWhite equivalent make in existing opening including grouting offastener with bolts, nuts making connections , testing etc. as reqd. 211 Making hole in wall/ window of required size for housing exhaust fan of above Size of exhaust fan sweep and making good the damages with cement morter, weldingetc. as required. 212 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 213 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, after removing recessed existing board, disconnectionmaking connections and testing etc. as required. 214 Supplying & fixing call bell/ ding dongsuitable for single phase ,230 volts on the existingbox/wooden blockincluding making connections etc. as requierd. 215 S/F 20A SPNindustrial socket outlet , with 2 pole and earth, metal enclosed plug top along with 20 Amp, C, curve SP, MCB, in sheet steel enclosure, on surface or in recess, with chained matal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 216 Supplyof following sizes Pearl Ivory white colour, ceiling fan r apprved make without regulator complete withdoubleball bearing, motor, blades, down rod, canopy,etc. complete as required. 217 Size 1400 mm. 218 Size 1200 mm 219 Installation, testing and commissioning of ceiling fan, including wiring the down rods of length upto 30 cmwith 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. complete as required. 220 SITC of wall mounted dust and vermin SMC Junction box with mcb Din rail detachable gland plate, locking arrangement for equipment/ switchgear withS/F of 100 amp 3 pole Isolator and 100 amp neutral link 221 SITC of wall/ surface mounted dust and vermin SMC Junction box (200 x 140 x 95) with3 phase 4 wire connector sintex make or equivalent with mcb Din rail detachable gland plate, locking arrangement for equipment/ switchgear 222 SITC of wall mounted dust and vermin proof, compartmentalised 900 X 900 X 230 cubical meter panel made out of CRCA sheet, required hardware, duly painted by powder coating with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate, fixing of glass for observe meter reading without opening the hinged door with locking arrangement for equipment/ switchgear/ busbar chamber/ cable alley . Thickness of sheet shall not be less than 2.0mm of any compartment. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls compartments having bolted type doors with detachable extension type structure. S/F of following accessories and their inter connections with lugs, terminating all the outgoing and incoming supply terminals in cable alley fixed on SMC/DMC type insulators/ suitable size connectors (as per requirement) with suitable size copper strip with heat shrinkable PVC sleeves/ wire, testing etc as required.( face area of board not less than 2.41 sqmtr.) 223 also only outer area of board should be measured).(Panel should be fabricated & assembled as per attached drawing through electrical panel builders and delivery challan should be produced along with panel)1No- quick make and quick break 4 Pole current limiting MCCB 125 Amp., 25 KA adjustable O/L & fixed S/C setting with Thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs/ spreaders, Direct rotary handle etc. as required for incoming circuit. b) 1 Set – 200 A, 4 strips copper busbar of suitablelength, fixed on SMC/DMC type insulators & colour coding with heat shrinkable PVC sleeves c) 1Set 240/220 volts pilot lamps with intenral circuit, terminal block,including 3 nos. SP MCB 0-5AMP. B curve,10 KA, 415 V. grade of approved make for 3- phase supply, making connections with lugs, testing for incoming circuit etc. d) 5Nos. Single phase, two wire solid state (static) fully electronic energy meters of accuracy class 1.0 & current rating 10-60 A, with backlit LCD display for 240 Volt systems, direct operated type, 50Hz having resolution 0.1kwh, led indicator for temper operation and meter sealing as per IS: 13779 etc. as required.e) 5 sets63 amp SP&N MCB for outgoingwith suitable size FRLS PVC insulated copper conductor up to MCBs, to receive XLPE aluminium/ copper cable/10 Sq.m copper wire of 1.1KV grade for outgoing ckts. 224 SITC of wall mounted dust and vermin proof, compartmentalised 1100 X 1200 X 250 cubical meter panel made out of CRCA sheet, required hardware, duly painted by powder coating with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate, fixing of glass for observe meter reading without opening the hinged door with locking arrangement for equipment/ switchgear/ busbar chamber/ cable alley . Thickness of sheet shall not be less than 2.0mm of any compartment. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls compartments having bolted type doors with detachable extension type structure. S/F of following accessories and their inter connections with lugs, terminating all the outgoing and incoming supply terminals in cable alley fixed on SMC/DMC type insulators/ suitable size connectors (as per requirement) with suitable size copper strip with heat shrinkable PVC sleeves/ wire, testing etc as required.(face area of board not less than 3.7 sqmtr.) 225 also only outer area of board should be measured).(Panel should be fabricated & assembled as per attached drawing through electrical panel builders and delivery challan should be produced along with panel)a) 1No- quick make and quick break 4 Pole current limiting MCCB 125 Amp., 30 KA adjustable O/L & fixed S/C setting with Thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs/ spreaders, Direct rotary handle etc. as required for incoming circuit. b) 1 Set – 200 A, 4 strips copper busbar of suitablelength, fixed on SMC/DMC type insulators & colour coding with heat shrinkable PVC sleeves c) 1Set 240/220 volts pilot lamps with intenral circuit, terminal block,including 3 nos. SP MCB 0-5AMP. B curve,10 KA, 415 V. grade of approved make for 3- phase supply, making connections with lugs, testing for incoming circuit etc.d) 6Nos. Single phase, two wire solid state (static) fully electronic energy meters of accuracy class 1.0 & current rating 10-60 A, with backlit LCD display for 240 Volt systems, direct operated type, 50Hz having resolution 0.1kwh, led indicator for temper operation and meter sealing as per IS: 13779 etc. as required. e) 6 sets63 amp SP&N MCB for outgoingwith suitable size FRLS PVC insulated copper conductor up to MCBs, to receive XLPE aluminium/ copper cable/10 Sq.m copper wire of 1.1KV grade for outgoing ckts. 226 EARTHING: Earthing as per IS:3043 with G.I earth plate 600 x 600 x 6mm thick including accessories embodying by digging 4mtr below the ground lavel with alternate layers of salt and charcoal (95 kg. each) with 20mm dia G.I. B class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete and testing of earth resistance as required. 227 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 228 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 229 Supplying & drawing following sizes hard drawn copper/ GI wires on existing cross arms through insulator/ on poles with all necessary T & P reqd. including binding and twisting, connections etc. as reqd.. 230 8 SWG G.I. wire(hot dipped) 231 Supply of XLPE insulated PVC sheathed 1.1 kv. Grade al. conductor armoured CableIS: 7098 Part-1 of approved make. 232 4 X 16 Sqmm. Aluminium cable 233 4 X 25 Sqmm. Aluminium cable 234 4 X 10 Sqmm. Cu. cable 235 4 X 16 Sqmm. Cu. cable 236 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 237 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on wall/ roof/ duct/ / Pole, shaft including fixing by means of screws & rag bolts, suitable size MS U clamps complete as per specifications, repairing works etc as reqd. of following sizes of cables. 238 upto 35 Sqmm.(clamped with 1mm thick saddle) 239 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 240 Upto 35sq.mm 241 Supply& making one end termination with heavy duty single compression brass gland SIBG type, aluminium/ copper lugs duly crimped with crimping tool, PVC tape etc. for following size of XLPE insulated & PVC sheathed aluminium/ copper cable of 1.1 KV grade as required. 242 2 X 10 sq. mm 243 4 X 16 Sqmm 244 4 X 25 Sqmm. 245 4 X 10 Sqmm (Copper) 246 P & F Bakelite sheet of following thickness on the R.C.C. pole including fixing of nut-bolts, drilling holes etc. as reqd. for fixing of porcelain cutouts.( Make – Hylam , Formica ) 247 12 mm thick. 248 P & F 415 Volts , kitkat fuses complete with base on existing bakelite sheet on top of the R.C.C. poles including making connections etc. as reqd of following ratings. 249 100A, 415 Volts 250 Fixing of jumpher wires or joints at one or both ends for existingO.H. 3 phase lines irrespective of sizes on pole, per job consist of single wire joint or re-jumphering either in O.H. lines or in kitkat fuse. 251 Supplying and making outdoor end termination with heat shrinkable/cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 252 4 X 25 Sqmm. 253 DISMANTLING: Labour charges for Dismantling of circuit wiring 1.5 Sq.mm to 6 Sq.mm wires in existing conduit /cassing capping, conduit fittings and depositing the same with listing of materials in stores / EME Div as required..( length of conduit/ batten measured only ) 254 Labour charges for dismantling of surface/ recessed light power point switch board of any size and depositing the same with listing of material in store. 255 Dismantling of existing armoured cables of following sizes safely from Lab room duct/ shaft/ wall/ board including disconnections & making good the damages,return back the dismantled items to store/ EME Div. etc as required. 256 Upto 35Sqmm.