Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 05-09-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 2 | Material and labour forbrick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 3 | Material and labour forbrick work with sub class `B` bricks, old size (Except bricks),straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.Note: Serviceable bricks obtained from demolition vide serial Item No. 1 shall be re-used. |
| 4 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including raking out joints, hacking for Key, scrubbingdown with water etc. complete all as specified and as directed. |
| 5 | Material and labour for 15mm thick rendering in CM (1:4) onbrick work or concrete surface as on wall in two separate coat (10mm thick backing coat and 5mm thick as finishing coat mixed with integral water proofing compound @ 2% by wt of cement,finished the surface even and fair complete all as specified and directed.(Note:Water proofing compound shall be measured & paid separately) |
| 6 | Materials and labour for 5 mm thick rendering onconcrete surfaces as on ceilingin cement mortar (1:3) andfinished the surfaces even and smooth without using extra cementcomplete all as specified and as directed. |
| 7 | Material and labour for repair to ends of chajjas/soffits/ceiling (thickness of slab 10cm) by removing loose concrete materials at the height upto 12m, cleaning the reinforcement, fixing of wiremesh to reinforcement and finishing surfaces fair and even by using CM 1:4 and applying two coats of weather proof paint over a coat of alkali primer including necessary scaffolding etc complete all as specified and as directed. |
| 8 | Materials and labour for 10 mm thick rendering on other than fair faces of brick work or concrete surface as on wallin cement mortar (1:6) andfinished the surfaces even and smooth without using extra cementcomplete all as specified and as directed. |
| 9 | Supply only integral water proofing compound (WPC) of best quality (ISI marked) completeall as specified and as directed. |
| 10 | Demolition of cement concrete (unreinforced) in ground floors and paving n.exc.15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed.. |
| 11 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in flooring/plinth protection and finish the surface even and smooth without using extra cement complete all as specified and as directed. |
| 12 | M & L for Forming Contraction Joint [Dummy], 65mm deep X 10mm wide, filled with sealing compound and sealed with Sealing Compound Grade \"A\" complete all as specified and directed. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding, (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 14 | Material & Labour for non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38sqm in floors etc.set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE |
| 15 | Material & Labour for non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38sqm as in skirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over and including rendering of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed.Note: The colour / shade / design of tiles shall be as approved by GE |
| 16 | Material & Labour for non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.06 sqm but not exc 0.11sqm in floors etc.set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE |
| 17 | Material & Labour for glazed ceramic coloured tiles 450 x 350 x 7 mm thick of premium quality as in skirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over and including rendering of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 18 | Material & Labour for Granite Stone Slabs of 20 mm thick of Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite shall be of design / pattern as directed including screed bed of mortar 20 mm thick in Cement Mortar 1:3complete all as specified and as directed. Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves. |
| 19 | Demolition of Stone Slab laid, bedded and pointed in Cement Mortar of any thickness complete all as specified and as directed. |
| 20 | Material and labour for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base floor and finish the surface even and rough complete all as specified and as directed. |
| 21 | Material and labour for 25mm thick PCC (1:2:4) type B0 (using 12.50mm graded stone aggregate) as floor finished even and rough to receive the top layer complete all as specified and as directed. |
| 22 | Material & Labour for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed of mortar 20 mm thick in Cement Mortar 1:3 complete all as specified and as directed. |
| 23 | Material & Labourfor machine cut kota stone slab as in riser of steps, skirting, dado etc. using 20 to 25mm thick slabs laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including borders, margins in two or more shades of slabsover and including rendering of 10mm thick in cement mortar 1:3 complete all as specified and as directed. |
| 24 | Taking down chowkat with shutter without taking off shutter from the frame exc 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed. |
| 25 | Taking down shutters of any description exceeding 2.00 Sq.m each and removing unserviceable material from site of work complete all as specified and as directed. |
| 26 | Taking down shutters of any description not exceeding 1.00 Sq.m each and removing unserviceable material from site of work complete all as specified and as directed. |
| 27 | Taking down shutters of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each and removing unserviceable material from site of work complete all as specified and as directed. |
| 28 | Taking down and refixingin the same opening shutters of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed. |
| 29 | S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. |
| 30 | S & F Factory made, 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 31 | Supply & Fixing factory made, 35mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [a] and fitted to Chowkats complete all as specified and as directed. |
| 32 | S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening, sizes of sections and other details as specified in SSR Part – I, Section 8, Clause 8B.3.1 complete all as specified and as directed |
| 33 | Supply and fixfactory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top andbottom rails. MS frame shall be covered with heat moulded decorative coloured laminates PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and decorative coloured laminates PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail or bottom rail ; panelling of decorative coloured laminates PVC sheet to be fittedin the MS frame welded/sealed to the stiles & rails with suitable PVC laminated sheet beeding, and joined together with solvent cement, supplying and fixing in the frame at the site as per specification and drawings as shown in SSRcomplete all as specified and as directed. |
| 34 | Providing and fixing factory made uPVC white colourSliding window Three track area not exceeding 2.00 Sqm each made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and as directed.Note: (i) The unit rate quoted by contractor excludescost of glass and includes all other connectedaccessories. (ii) Net Opening will be measured lorpayment purpose. |
| 35 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixinghardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealantover backer rod of required size and of approvedquality, all complete as per approved drawing &direction of Engineer-in-Charge. (Glass shall be paidseparately).Note: (i) For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.(ii) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 36 | Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staplescomplete all as specified and as directed. |
| 37 | Supply and fixing 4mm thick plain tinted sheet Glass ordinary quality in squares not exceeding 0.5 Sq.m each pane for aluminium window complete all as specified and as directed. |
| 38 | Supply and fixing Floor Door Stopper of size 140 mm ofaluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed. |
| 39 | Supply and fixing 75mm size Butt hinges, mediumweight, cold rolled mild steel, and fixed complete all as specified and as directed. |
| 40 | Supply and fixing 100mm size Butt hinges, mediumweight, cold rolled mild steel, and fixed complete all as specified and as directed. |
| 41 | Supply and fixing aluminium anodized, barrel tower bolts, 150mm long of extruded section complete all as specified and as directed. |
| 42 | Supply and fixing aluminium anodized, barrel tower bolts, 200mm long of extruded section complete all as specified and as directed. |
| 43 | Supply and fixing 150mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed. |
| 44 | Supply and fixing Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 45 | Supply and fixing 50mm size Butt hinges, mediumweight, cold rolled mild steel, and fixed complete all as specified and as directed. |
| 46 | Dismantling of Mild Steel or Wrought Iron Work of any description not otherwise provided for complete all as specified and as directed. |
| 47 | Material and labour mild steel work as in holdfast and similar works conforming to Fe290 GDE E-165 complete all as specified and as directed. |
| 48 | Material and labour Plain cement concrete type C-1 1:3:6 (20 mm graded stone aggregate) as in hold fast complete all as specified . |
| 49 | Supply and fixing in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and \"P\" or \"S\" trap including making good the disturbed floor complete all as specified and as directed. |
| 50 | Supply and fixing in repair of Stainless steel kitchen sink with drainage board, made of stainless steel sheet of 1 mm thick, with plugs, washers, Waste Fittings, 32 mm dia, Brass, Chromium plated and 32mm dia PVC flexible Waste Pipe, 750 mm long, including bedding in Cement Mortar to dwarf wall or including fixing cantilever CI Brackets and connecting union to waste pipe overall size 915mm x 460mm and bowl size 410mm x 330mmx 160mm depth complete all as specified and as directed . |
| 51 | Dismantling of plain or corrugated steel sheeting,any gauge, thickness, including similar pattern roof covering complete all as specified and as directed. |
| 52 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated trapezoidal profie sheet steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 53 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 54 | Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed . |
| 55 | Supply and fixing Mild Steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290, Grade E-165 complete all as specified and directed. |
| 56 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets complete all as specified and as directed. |
| 57 | Supply& Fixing 4mm thick plain E board of size 600 X 600 mm of approved texture, design and patterns, suspended on the Exposed Metal Frame Ceiling Grid of 600mm x 600mm size and applying two coats of Oil Bound Distemper over a coat of alkali resistant primer and including GI powder coated snap grid frame work of size600 mm x 600 mm with main/ cross tee of size 24 x 38 x 0.70mm thick and wall /cleat angle of size 25 x 25 x 0.35 mm duly suspended with 4 mm dia GI wire hanger 1200 mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed. |
| 58 | Supply and fixing 2nd class HW Weather boarding,clean sawn, plain 20mm thick or reather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and as directed. |
| 59 | Supply and fixing in repair18/19 mm thick interior grade prelaminated particle board prelaminated on one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work complete all as specified and as directed. |
| 60 | Supply & Fixing Continuous [Piano] Hinges, Mild Steel, Bright finish or Electrogalvanised and width of Flaps 30mm [When Open] complete all as specified and as directed. |
| 61 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 62 | Supply & Fixing in repairs white Vitreous China Squatting Pan \"Orissa Pattern\" of size 580 mm X 440 mmwith integral foot rests and \"P\" or \"S\" Trap includingprovision of lime concrete bedding complete all as specified and as directed. |
| 63 | Supply and fixing in repairs 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed. |
| 64 | Supply and fixing vitreous china light colour shade wash basin white, oval shape of size 550x400 mm including32mm dia PVC waste pipeCP brass wast coupling 32 mmdia , pair of MS angle brackets or MS fastener/ bolts for fixing arrangements completeat site and all as directed . |
| 65 | Supply and fix in repair pillar taps 15mm dia bore fancy typewith capstain heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified directed. |
| 66 | Supply and fixing in repair 75 mm dia PVC (SWR) floor trap, plain with grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B-1, diameter of outlet pipe 75mm complete all as specified and as directed. |
| 67 | Supply and fix in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 68 | Supply and fixing in repairs 15mm bore fancy type chromium plated bib taps with crutch of butterfly handle screwed down for iron pipes complete all as specified and directed. |
| 69 | Supply and fixing in repairs Stop Valves, 15 mm dia, cast copper alloy, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed. |
| 70 | Supply and fixing in repairs of size 125 mm brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe or union complete all as specified. |
| 71 | Supply and fixing in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed. |
| 72 | upply and fixing in repairs looking mirror ofsize 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and as directed. |
| 73 | Supply & Fixing in repairs Shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms complete all as specified and as directed. |
| 74 | Taking up or down steel tubing 15mm bore and connections including cleaning for refixing and deposited to stores complete all as specified and directed. |
| 75 | Supply and fixing 15mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid under floors complete all as specified and as direcetd. |
| 76 | All as per Serial Item No. 75 but except 15mm bore galvanised steel water tubing medium grade complete all as specified and as direcetd.Note: The serviceable pipes obtained from taking down vide serial No. 74 shall be re-used. |
| 77 | M&L for cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 tro ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc. 10 cm girth complete all as specified and directed.Note: Cutting of holes will be carried out by using mechanical means like Groove cutter/ wall chaser. |
| 78 | Taking up or down steel tubing 20mm bore and connections including cleaning for refixing and deposited to stores complete all as specified and directed. |
| 79 | Supply and fixing 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid under floors complete all as specified and as direcetd. |
| 80 | All as per Serial Item No.79 but except 20mm bore galvanised steel water tubing medium grade complete all as specified and as direcetd.Note: The serviceable pipes obtained from taking down vide serial No. 78 shall be re-used. |
| 81 | upply and fixing in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 82 | Supply and fixing 110 mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/ laid in floors complete all as specified and directed. |
| 83 | Supply and fixing 75 mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls / laid in floor complete all as specified and directed. |
| 84 | Supply and fixing 110 mm bore PVC (SWR) bends in any types complete all as specified and directed. |
| 85 | Supply and fixing 110 mm bore PVC [SWR] Branch Piece, Single [Single \"T\"] equal or unequal including jointing with solvent cement complete all as specified and as directed. |
| 86 | Supply and fixing 75 mm bore PVC [SWR] Branch Piece, Single [Single \"T\"] equal or unequal including jointing with solvent cement complete all as specified and as directed. |
| 87 | Supply and fixing 75 mm bore PVC (SWR) bends in any types complete all as specified and directed. |
| 88 | Supply and fixing 110 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 89 | Supply & fixing in repair of fancy type decorative Drapary MS rod of 20mm dia suitable for window and doors with decorating doom holders fixed to wall with screwscomplete all as specified and as directed. |
| 90 | Supply and fixing in repair Rotational Moulded Polythene [HDPE] triple layered Water Tanks, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including Ball Valves, 20 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 20mm - 210 Grams] etc. complete all as specified and as directed. |
| 91 | Supply and fixing Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long including fixing arrangementcomplete all as specified and as directed. |
| 92 | S & F Vitreous China soap tray embedded in the wall complete all as specified and as directed. |
| 93 | S & F in repairs Vitreous china urinal, half stall type, flat back, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, grating and union for discharge pipe, CP screws etc complete all as specified and as directed. |
| 94 | Supply and fixing in repair Vitreous china urinal partition white of size 310x700 mm complete all as specified and as directed. |
| 95 | Material and labour for preparing newly plastered Wallsurfacesandapplying two coats of Oil Bound Distemper over a coat ofprimer over one mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed. |
| 96 | Material and labour for Complete removal of existing treatment of any description on wallsurfaces and applying 1mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Oil Bound Distemper over one coat of primer on wallsurfaces complete all as specified and as directed. |
| 97 | Material and labour for preparation of newly plastered wall surfaces and applyingAcrylic Smooth exterior paint of required shade, two coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqmon wallsurfaces complete all as specified and as directed. |
| 98 | Material and labour for removal of existing finishes, preparation of surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 99 | Material and labour for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed. |
| 100 | Material and labour forpreparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and as directed. |
| 101 | Material and labour for preparation of new steel surfaces to receive painting over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primercomplete all as specified and directed. |
| 102 | Material and labour for preparation of old wooden surfaces over 10cm width or girth and applying one coat of syntheticenamel paint complete all as specified and directed. |
| 103 | Material and labour for preparation of old steel surfaces over 10cm width or girth and applying one coat of syntheticenamel paint complete all as specified and directed. |
| 104 | Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in surface channel and like etccompleteall as specified and as directed. |
| 105 | Materials and labour for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.completeall as specified and as directed. |
| 106 | Material and labour for Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto - |
| 107 | Material and labour for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, benching, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed. |
| 108 | Demolition and breaking up drain pipes of 75/100 bore (Salt glazed ware, AC or Reinforced concrete)/ PVC/CI set in cement mortar complete all as specified and directed. |
| 109 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 15mm thickin cement mortar 1:4 on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound @ 2% by weight of cement of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, applying one coat of hot paving bitumen of penetrationvalue 85/25 conforming to IS 73 @ 1.20 kg/sqm over a coat of bitumenous primer @ 0.30 ltrs per sqm and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.00 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) shall be applied overBitumenious primer (Application of polymeric memberane shall be by torch application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinaldirection) polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall ( Cont..) |
| 110 | and shall be finished by membrane flashing, coved fillet in PCC (1:2:4) type B-0 of radius 75 mmshall be provided at the junction of roof & other vertical surfaces& surfaces shall be painted with hot paving bitumen of penetrationvalue 85/25 conforming to IS 73 @ 1.20 kg/sqm including taking down existing Roof Treatment of any description and removing rubbish to a distance not exceeding 50 M complete all as specified and as directed. Note: (i) Water proofing compound will be measured and paid separately. |
| 111 | Material and labour PCC tiles of size 300mmx300mm of 25mm thick as in floors set , jointed & pointed with neat cement slurrywith white cement and pigmentincluding15 mm thick screed bedor bedding layer incementmortar (1:4) complete all as specified and as directed. |
| 112 | Material and labour pre polished, precast Chequered cement concrete tiles of size 300mmx300mm of 25mm thick as in floors set , jointed & pointed with neat cement slurrywith white cement and pigmentincluding15 mm thick screed bedor bedding layer incementmortar (1:4) complete all as specified and as directed. |
| 113 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, (including unscrewing from boards/out-let boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.), removing materials off the site of work and making good disturbed surfaces of walls, floors, etc.all as directed. |
| 114 | Material and labour for point wiring, concealed on wall or ceiling for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LS) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LS) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuitywire connected to common earth dolly drawn through and including 20mm dia PVC rigid conduit of adequate sizewith all accessories and the cables will terminate to Modular Type Pressed Metal Flush Box made out of 1.6mm thick MS Sheet of suitable size duly painted with black bitumen paint over a coat of red oxide primer and providing white modular cover plate for mounting modular Switches, Sockets, bell/buzzer and Regulators etc. concealed in walls complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting chases will be carried out by using mechanical means like Groove cutter/ wall chaser.(iii) payment for cutting chases shall deemed to be included in the quote rate. |
| 115 | .-Ditto- all as per item No 113.00 here-in-before butfor 3 pin 6 amps switch socket outlet on the independant boardwith 1.5 Sqmm cable and -ditto-. |
| 116 | .-Ditto- all as per item No 113.00 here-in-before butfor 3 pin 6 amps switch socket outlet on the same board with 1.5 Sqmm cable and -ditto-. |
| 117 | .-Ditto- all as per item No 113.00 here-in-before butfor one 3 pin 16 Amps socket outlet on independent boardwith 2.5 sqmmPVC (FR-LS) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LS) copper conductor cable as earth continuity conductor. |
| 118 | Supply and fixing modular switch, 1 way, 6 A, 1 module complete all as specified and as directed. |
| 119 | Supply and fixing modular socket,6 A, 2/3 pin, 2 module complete all as specified and as directed. |
| 120 | Supply and fixing modular socket,6 / 16 A, 2/3 pin combined, 2 module complete all as specified and as directed. |
| 121 | Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 65mm x 50mm,ISI marked three terminals complete all as specified & directed. |
| 122 | Supply and fixing modular switch, 1 way, 16 A, 1 module complete all as specified and as directed. |
| 123 | Supply & Fixing bell push modular type 5 Amps complete all as specified and directed. |
| 124 | Supply & Fixing bell electric ding dong modular type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 125 | Supply and fixing modular fan regulator 120 watt step type AC 220 Volt complete all as specified and as directed. |
| 126 | Supply and fixing of MCB DB SPN 8 ways double door including bus bar neutral link, earth bar and din rail,recessed with wall surfaces by chase cutting and making good surfaces of wall including taking down of existing unserviceable DB complete all as specified and as directed. |
| 127 | Supply and fixing of MCB DB VTPN four way double door, ( for DB where MCBs to be used), 415 Volts, powder paintedincluding bus bar neutral link, earth bar and din rail,recessed with wall surfaces by chase cutting and making good surfaces of wall including taking down of existing unserviceable DB complete all as specified and as directed. |
| 128 | Supply and fixing of MCCB 125 Amps, FP, 415 Volt, breaking capacity 16 KA complete all as specified and as directed. |
| 129 | Supply and fixing of MCB 40-63 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 130 | S & F in repair SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 10 Amps, 240 Volts complete all as specified and as directed. |
| 131 | Supply and fixing of MCB 6 to 32 Amps, SP, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. Note for serial Item No. 125 to 130: MCB, MCCB, MCB DB and MCCB DB shall be of same make as approved by GE. |
| 132 | S & F in repairs round shape recessed type ceiling LED Light of 15 Watt with high efficiency PMMA diffuser soft glare free light complete with drivers, holders with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 133 | S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 20 W, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 134 | Supply and fixing in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting mirror type, of 10 W, 2 feet long, 6500 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 135 | S & F Energy efficient LED Flood Light fitting of 30 watt, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 136 | S & F in repairs Integral LED Post Top Lanterns, 20 Watt, cast aluminium spigot housing with decorative opal acrylic diffuser and IP-65 protection complete all as specfied and as directed. Note: Light fitting shall be of PF>0.95 |
| 137 | S & F Energy efficient & Long life Building Security Light Luminaire, of not less than 25 W, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mmincluding taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 138 | Supply and fixing ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with squirrel cage induction motor including taking down of unserviceable ceiling fan and deposited to MES store yard complete all as specified and directed. |
| 139 | Taking down exhaust fan carefully of any size from its original position, kept in safe custody, cleaning, painting and refixing the fan, connecting to ceiling rose with 3 core flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and directed. |
| 140 | Taking down exhaust fan carefully of any size from its original position, kept in safe custody, cleaning, painting and refixing the fan, connecting to ceiling rose with 3 core flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and directed. |
| 141 | M & L for surface sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces inculding taking down the old unserviceable one all as specified as directed. Note : (i) 3 Runs of 10.00 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.(ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 142 | M & L for surface sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces inculding taking down the old unserviceable one all as specified as directed. Note : (i) 3 Runs of 6.00 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.(ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 143 | M & L for surface sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces inculding taking down the old unserviceable one all as specified as directed. Note : (i) 3 Runs of 4.00 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.(ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate. |
| 144 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 145 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail