Supply, Installation, Testing and Commissioning of Lifts in three buildings-- 1 Supply, Erection, Testing and Commissioning of 13 Passenger Machine Room less Gear less, Lift for IIandHS (G plus 3) Storey Building at KUK with 5 year AMC (after warranty period). Make: OTIS/ KONE/ ORBIS /MITSUBISHI/ SCHINDLER/OMEGA/ JOHNSON ELEVATOR 2 Supply, Erection, Testing and Commissioning of 08 Passenger Machine Room Less Gearless Elevator in 06 (G plus 05) Storey Sports Hostel (Near Harsh Bhawan) Building at KUK with 5 year AMC (after warranty period). Make: OTIS/ KONE/ ORBIS /MITSUBISHI/ SCHINDLER/ OMEGA/ JOHNSON ELEVATOR 3 Supply, Erection, Testing and Commissioning of 08 Passenger Machine Room Less GearlessElevator in 03 (G plus 02) Storey Ranganathan Block of JLN Library Building at KUK with 5 year AMC (after warranty period).Make: OTIS/ KONE/ ORBIS /MITSUBISHI/ SCHINDLER/ OMEGA/ JOHNSON ELEVATOR 4 [30.34.1]Distempering with 1st quality acrylicdistemper (ready made) having VOC content less than 50 gm per litre. of approved manufacturer and of required shade and colour complete. as per manufacturer`s specification. 1. One or more coats on old work [Through Rate] 5 [5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. [Through Rate] 6 [6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate] 7 [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). [Through Rate] 8 [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] 9 [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] 10 [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] 11 [7.27.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in : 2. cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] 12 Renovation of house NO. D-101(B) and D-105 at kurukshetra 13 Providing and laying Designer anti skid parking floor tiles of size 12mm thick of approved make in all colours and shade .20mm thick cement mortar in 1:4 cement sand mix . 14 P/F 110MM UPVC FLOOR TRAP as per is-14735 with concrete 1:2:4 under the floor trap upto level cutting and makking good the wall floors.