| 1 | Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrabbing down with water etc of any description complete all as specified and directed. |
| 2 | Demolition of cement concrete unreinforeced of any description and in any postion not other wise specifically provided for roofs, floors (other than ground floors) beams,staircase.landing,chajja and similar suspended work complete all as specified and directed. |
| 3 | Demolition of concrete in ground floors and paving n.exc 15 cm thickness (below or above the ground level) complete all as specified and directed. |
| 4 | Dismantling of structural steel work including door, gate but excluding framed truss etc complete all as specified and directed. |
| 5 | Dismantling fencing wire mesh any type complete all as specified and directed. |
| 6 | Demolition of brickwork or stone/boulder masonary built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 7 | Dismantling posts or struts (wood, steel or RCC) any section embedded in concrete, brick work, masonary etc including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 8 | M&L for rendering 20 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 finished even and smooth with out using extra cement by mixing of water proofing compound at the rate of 3% by weight of cementcomplete all as specified and directed. Note :- WPC shall measured and paid separately. |
| 9 | M&L for cement concrete in foundations, filling and mass concrete Type D-2 1:4:8 (40 mm graded stone aggregate) complete all as specified and directed. |
| 10 | M&L for cement concrete in foundations, filling and mass concrete Type D-2 1:2:4 ( 40 mm graded stone aggregate) complete all as specified and directed. |
| 11 | M&L for 25 mm thick cement concrete type B-0 1:2:4 (12.5 mm graded stone aggregate) complete all as specified and directed. |
| 12 | M&L for 75 mm thick cement concrete type D-2, 1:4:8 as in sub floors,sub bases, floors and paving etc complete all as specified and directed. |
| 13 | M&L for 75 mm thick cement concrete type D-2, 1:4:8 as in sub floors, sub bases, floors and paving etc complete all as specified and directed. |
| 14 | M&L for Brick Masonry with subclass \"B\" bricks, straight or curved on plan exc 6M mean radius built in Cement Mortar 1:6 complete all as specified and directed. |
| 15 | S&F for weldedsteel wire fabric of mesh density 5mm (square hole 2\" x 2\") fixed complete to wood or steel membersof weight per square mtrt exc 4 Kg complete all as specified and directed. |
| 16 | S&F for chain link MS galvanised fencing any size or type including line wires, any mesh,size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. |
| 17 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum in soft/ loose soil, getting out, returning,filling in and ramming earthor brilen rubble mixed with earth around, inlayers not exceeding 25 cm, eatering and removing surplus soil to a distance n.exc 50mtrand making good surface complete all as specified and directed. |
| 18 | S&F for Fe-410 W(Gde-250)quality B for fabrication of framed work as in doors or gates of angle or other section with gusset plate, rails braces etc complete drilled forfixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel, sheeting or other covering, running rails and guides) hanging also fastening and fixing complete all as specified and directed. |
| 19 | S&F for Fe-410 W (Gde-250) quality Bjoist, channel, angle or tee section fixed independently, with out connecting plates (cut to ordinary length i.e. within 20mm of the length indicated complete all as specified and directed. |
| 20 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 21 | Excavating over areas n.exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cmcomplete all as specified and directed. |
| 23 | Removing excavated material n exc. 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 24 | M&L for RCC nominal mix type B-1 1:2:4(20 mm graded stone aggregates) as in foundations, including rafts, footing, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles complete all as specified and directed. |
| 25 | M&L for RCC nominal mix Type B-1 1:2:4 (20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 26 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundations (if any) of foundation and plinth beams ,and similar work, verticalor to batter for flat rough finished surfaces complete all as specified and directed. |
| 27 | Formwork to square, rectangular or polygonal concretesidesof pillars, posts, struts, piers, columns and stanchionsfor fair finished concrete surfaces complete all as specified and directed. |
| 28 | M&L for providing precast cementconcrete Type B1 ( 20 mm graded stone aggregate) set in cement mortar 1:6 in landings,cover slabs (for manholes etc) chullah hoods,chajjahs water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 29 | M&L for rendering 15mm on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in cement mortar 1:4, finished even and smooth with out using extra cement complete all as specified and directed. |
| 30 | M&L for TMTmild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 31 | All as item No- 30 here in before but 6-8 mm dia and over as in stirrups,spacers and binder etc complete all as specified and directed. |
| 32 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 33 | M&L for Endura tiles 8 to 10 mm thk (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm, in footpath etc complete all as specified and directed. |
| 34 | M&L for 100 mm thick Plain cementconcrete 1:4:8 type C2 using 40mm graded stone aggregate as sub bases, sub floors/ paving complete all as specified and directed. |
| 35 | M&L for 15 mm thick screed bed or bedding layer of cement mortar 1:4 under the endura tiles complete all as specified and directed. |
| 36 | M&L for broken stone or boulder hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 37 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 as in sub floors, sub bases, floors and paving etc complete all as specified and directed. |
| 38 | M&L for 100 mm thick cement concrete type D-2, 1:2:4 as in sub floors, sub bases, floors and paving etc complete all as specified and directed. |
| 39 | M&L for Forming 12 mm thick expansion joints in 100 mm thick concrete slabfilled with pre -formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade \"B\" complete all as specified and directed. |
| 40 | M&L for Forming contraction joints (Dummy) joints of size65 mm x 10 mm wide, filled with sealing compound of Grade \"B\" complete all as specified and directed. |
| 41 | M&L for 450 mm reinforced concrete pipes,class NP3, laid and jointe dcomplete with collars complete all as specified and directed. |
| 42 | M&L for cement concrete type B1 1:2:4 using 20mm graded stone aggregate in roof kerb or mud stops, rounded or chamfered on edgein lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 43 | M&L for surface walltwo coat cement paint over priming plastered and other surfaces with alkali-resistant paint complete all as specified and directed. |
| 44 | M&L for Preparation of new steel Surfaces of any description, over 10cm in width or girth,of any description and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 45 | De-watering of SWT, septic tanks and soakage wells by manually or with pumping set and draining out the same out of cantt area complete all as specified and directed. |
| 46 | Taking up or down 15mmsteel tubing and connections, including cleaning for re-fixal or removal to store complete all as specified and directed. |
| 47 | Taking up or down 15mmsteel tubing and connections ,including cleaning for re-fixal or removal to store complete all as specified and directed. |
| 48 | S&F for 15mm dia medium grade GI tubing with all fitting and fixed to wall, ceilling or laid in floor etc complete all as specified and directed. |
| 49 | S&F for 20mm dia medium grade GI tubing with all fitting and fixed to wall, ceilling or laid in floor etc complete all as specified and directed. |
| 50 | Supply, laying, jointing and testing mild steel galvanised water tubing 100 mm bore, medium grade including all GI fittings, flange, nut bolt etc laid in trenches/ wall/ surface complete all as specified and directed. |
| 51 | Supply, installaling and testing of 15 HP, discharge rate 2000 LPM, 3 phase,415 volt, 50 Hz, minimum 15-20mtr head, self primingopenwell submersible pump set minimum 3 star including suction and delivery pipe and mounting arrengement with suitable size of nut bolt and washercomplete suitable for 100 mm Gl pipe in suction and delivery line complete all as specified and directed.Make:- Crompton Cat Part No OSW15.2. |
| 52 | S&F in repair PVC Sheathed, PVC insulated flat submersible copper cable, water proof best quality of size3 core, 10 Sqmm, 1100 volts gradefor connection to submersible pump set complete all as specified and directed. |
| 53 | Cutting of existing CI/ GI pipe 100 mm in position for insertion and including of new tee of size 100 mm complete all as specified and directed. |
| 54 | S&F in replacement of cast iron sluice valve of 100 mm bore, class PN 1.6, ISI marked with iron wheel head both end flanged, brass spindle any pattern with check nut complete with jointing material nut, bolt and washers etc complete all as specified and directed. |
| 55 | M&L for construction of valve pit chamber ofinternal dimension 90 x 90x 90 cm with sub class \"B\" bricks in cement mortar (1:4) and 10 mm thick plastering in cement mortar (1:4), PCC (1:4:8), type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 5 mm thick MS sheet cover plate with locking arrangement, double door type opening, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete including dismantling of old complete all as specified and directed. |
| 56 | Dismantling of old unserviceable Steel tubular pole of any size and type complete with insulators and cross arms including breaking of PCC foundation of pole after necessary earth work and returning filling of soil complete all as specified and directed. |
| 57 | Dismantling stay assembly complete all as specified and directed. |
| 58 | Dismantling of ACSR or AAC conductors from existing steel tubular LT pole complete all as specified and directed. |
| 59 | Materal and labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and directed. |
| 60 | M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified and directed.Note:- Earthwork/ PCC shall be measured and paid under appropriate items in Schedule. |
| 61 | M&L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as required or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 62 | M&L for stay assembly of stay rod of diameter 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed. |
| 63 | M&L for galvanised stay strand 7/3.15 complete all as specified and directed. |
| 64 | M&L for loop insulator large size with overall dimensions 90mmx140mm, clearance of hole 25.5mm complete all as specified and directed. |
| 65 | M&L for shackle type porcelain insulator, vitreous, white, brown or green including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and directed. |
| 66 | S&F for LED Flood Light 100 Watt 230 Volt AC, Outdoor type with Thermal Management in Multiple Optics and equipped with IP 66 Protection with Impact and Corrosion Resistant with Driver and Lamp including Electrically Connected complete all as specified and directed. |
| 67 | S&F cable junction boxes IP 66 \"halogen free and weather proof for outdoor installation (with metric knockouts for cable entry-Black Colour) of minimum size 200 x 140 x 95 mm for 16/25 sq mm fixed to pole /wall with suitable FI clamp 20X3 mm nuts, bolts and washers including provision of 01 No miniature circuit breaker (MCBs) single pole 240 volts 10 kA, 10 Amps and including minium 100 Amps aluminium busbar (04 Nos) with nuts, bolts & washers complete all as specified and directed. |
| 68 | S&F for 3 core copper conductor PVC insulated cable round of size 1.5 Sqmm FR RM multistranded 1100 volts grade complete all as specified and directed. |
| 69 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: Purned thickness of sand shall be measured & paid. |
| 70 | M&L for well burnt sub class B bricks of nominal size 230X115X75 mm abutting each ether for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 71 | M&L for boring/ drilling thorizontally) hole manually under existing road, pavement, hard standing (maximum 10 mtr in width) suitable for passing Gl tubing upto 80 mim bore complete all as specified and directed. |
| 72 | M&L for steel tubes, light grade galvanized of 80 mm bores laid in trenches/ surface for cable protection including fitting as clamps, nuts, bolts complete all as specified and directed. |
| 73 | Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm, 3.5 core complete all as specified and directed. |
| 74 | Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm, 3.5 core complete all as specified and directed. |
| 75 | Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm, 4 core complete all as specified and directed. |
| 76 | Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm, 2 core complete all as specified and directed. |
| 77 | Disconnecting cable from LT pole/LT panel and refix on LT panel with suitable size lugs complete all as specified and directed. |
| 78 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6.3mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means ofbolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete including dismantling the old complete all as specified and directed. |
| 79 | Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.5 mx0.9mx0.6m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement ,louvers at sides & duly powder coated includingin-panel CO2/Clean agent fire suppressing system complete for accomodating & including following accessories:- |
| 80 | DETAILS:-INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity36 kA of 200 Amps with fixed thermal and fixed magnetic setting- 01NosOUTGOING: (i) MCCB 4 Pole ,415 Volts with breaking capacity25 kA of capacity 100 Amps with thermal magnetic release -01 Nos (ii) MCCB 4 Pole ,415 Volts with breaking capacity16 kA of capacity 63 Amps with thermal magnetic release -02 Nos (iii)MCCB 4 Pole ,415 Volts with breaking capacity16 kA of capacity 40 Amps with thermal magnetic release -02 Nos (iv) MCB SPN 10-16 Amps - 01 No(v) S&F Automatic Star Delta Starter 415 volts, 50Hz, 3 phase, 15 HP including single phase preventer, over load relay protection, timer, contactors, mounting type-01. NosBUSBAR: (i) Cupper bus bar 300 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii)Digital ampere meter of 0-200 A, 3 phase, class 1 , including CT having CTR 200/5 - 01 No(iii)Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item.(ii) the GA drg of LT pannels shall be approved by GE before procurement. |
| 81 | Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1.0 m x 0.8 m x 0.45 m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- |
| 82 | DETAILS:-INCOMER: (i) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 63 Amps with fixed thermal and magnetic setting-01 Nos(b) Supply and fixing change over switch on load type, 63 Amps, 4 pole, 415 vott- 01 NoOUTGOING: (a) Supply and fixing MCCB & pole 415 Vots of brealung capacity of 16 KA of 40 Amps with fixed thermal and fixed magnetic setting-01 Nos(iii) MCB SPN 10-16 Amps - 01 No (b) S&F Automatic Star Delta Starter 415 volts, 50Hz, 3 phase, 15 HP including single phase preventer, over load relay protection, timer, contactors, mounting type-01. NosINDICATING DEVICES(a) Supply and lixing LED Indicating lamps for Main Supply Indicating R, Y, B-03 Nos(b) Supply and fixing Digital Ampere Meter for 0-100 Amp display including CT having CTR 100/5 with selector switch 01 No & Digital Voltmeter 0-500 Volts with selector switch - 01 NoBUSBAR: (i) Aluminium bus be 200 Amps, supported on non hygroscopic libres and brass screws for mounting-04 Nos |
| 83 | M&L for sub main wiring with two run of 2.5 sqmm PVC insulated unsheathed FLRS copper conductor single core multi strandedand one run of insulated copper earth wire 2.5 Sqmm drawn through PVC Casing caping complete all as specified and directed.Note :- Copper conductor 3 run of 2.5 sqmm and one run PVC Casing caping shall be measured as one length. |
| 84 | S&F for Modular switch 1 way 16A,1 module complete all as specified and directed. |
| 85 | S&F for Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 86 | S&F for White cover plate with frame, 4 module complete all as specified and directed. |
| 87 | S&F for Modular Metal flush box 4 module complete all as specified and directed. |
| 88 | Supply, installation,commis-sioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz having capacity of 500 Ltrs complete all as specified and directed. |
| 89 | Supply, installation,commis-sioning of Ice making Machine of capacity 60 Ltrs, self standing, made out of stainless steel body, air cooled with eco friendly refrigerant R- 404a working on single phase 240 volts, 50HZ power supply 29 Kg/24 hrs rated capacity and 9 Kg ice storage bin complete all as specified and directed. |
| 90 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |