Renovation Of Electrical Works In Veterinary Hospital, Madanpur Khadar Village, New Delhi-110072.- 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group-C 3 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 4 20 mm 5 25 mm 6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 7 3 x 1.5 sq. mm 8 3 x 6 sq. mm 9 3 x 4 sq. mm 10 6 x 4 sq. mm 11 3 x 6 sq. mm 12 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 13 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 14 Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc as required. 15 3 Module (100 mmX75 mm) 16 6 module (200mm x 75mm) 17 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required. 18 a) 5/6 amp switch 19 b) 3 pin 5/6 amp socket outlet 20 c) 15/16 amp switch 21 d) 6 pin 15/16 amp socket outlet 22 Supplying and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box i/c connections but excluding modular plate etc as reqd. 23 Supplying and fixing suitable GI box with modular plate and cover in front on surface or in recess i/c providing and fixing 25A modular socket outlet and 25A modular SP MCB C curve i/c connection, painting etc as reqd. 24 Supplying and fixing following way, single pole and neutral, sheet, steel, MCB distributions board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 25 a) 16way Double door 26 b) 6way Double door 27 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 28 a) Single pole 29 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 30 a) 40 amp 31 b) 63 amp 32 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 33 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 34 a) 63 mm dia (OD-63 mm & ID-51 mm nominal) 35 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 36 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 37 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 38 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driverefficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 39 18- 22 watt 40 Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 41 a) 18 watt 42 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 43 a) 36watt 44 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 a) 70 watt 46 Supplying and fixing of suitable H-shape angle iron suitable for fixing/mounting LED flood light on terrace etc as reqd. 47 Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 48 1.5 TR with 5 Star BEE Rating 49 Supplying ,installation , testing and commissioning of 4 KVA voltage stablizerwall mounted type for domestic use copper woundcompleteupto 1.5TR Capacity Air Conditioners unit, , Operating Voltage range (Input): 150-280 volts,Output 230+ 10 Volts, 50Hz AC supply etc. as required. 50 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 51 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. 52 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : a) bituminous road 53 Supplying. Installation, testing and commissioning of 300 mm sweep metallic heavy duty 900 rpm exhaust fan suitable for operation on 230V, 50 Hz single phase AC supply complete with louvers / shutters in the existing opening including making the hole to suit the size of the above fan making good the damage and connections etc. as reqd. 54 Supplying & fixing 400mm sweep wall mounted cabin fan with speed regulator oscilatting type i/c testing & commsisioning suitable for 230volt 50Hz AC supply etc as reqd. 55 Supplying, Installation, testing and commissioning of ceiling fan, (1200 mm) including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable suitable for 230V, 50Hz single phase AC supply etc. as required. 56 Supplying and fixing of pole box (200mmx140mmx95/100 deep) made out hot moulded SMC with 01no 16amp 3pole connector, din channel and 01 No. 6 Amp SPMCB complete with connections earthing testing etc as reqd. 57 Supply and fixing of 15/16Amp 3pin top plug including connection complete as reqd. 58 Supplying and fixing of Extra copper refrigerantpiping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd. 59 Providing and fixing of 4 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/ surface/ existing channel, i/c making connection etc as reqd. 60 Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd. 61 Supplying & Fixing wall/floor mounted stand for outdoor units of split AC complete etc as rquired. 62 Supplying & Laying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured cable on surface as reqd. 63 a) 3 x 10 Sqmm 64 Supplying & Laying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured cable in existing pipe/HUME as reqd. 65 a) 3 x 10 Sqmm 66 Supplying, Installation, Testing & Commissioning of 24volt 2000 VA pure sine wave inverter suitable for output voltage 200volt -240volt, 50Hz complete etc as required. 67 Supplying and installation of 12Volt, 150 AH tubular battery comprising of polypropylene material with suitable thimble and battery terminal for 2000VA invertor complete as required. 68 Supplying and fixing of MS double battery inverter trolly complete etc as reqd. 69 Supplying Installation Testing and commissioning of water cooler with 150/150ltr storage suitable for operation on 230Volts 10%, 50Hz, single phase AC supply with high efficiency compressor faster cooling, ergonomically desgined for greater safety and operational convenience low power consumption, superior quality grooved copper tubes in heat exchager, ISI marked blue fins on condensor coil, stainless steel body for longer product lift, stainless steel tank food grade water piping float valve and other components which come in contact with drinking water, water inlet, hosepipe, overflow pipe to be provided with water cooler packing adjustable pedestal made of high non corrosive strong material minimum two number faucets etc complete as reqd. 70 Supplying Installation Testing and Commissioning of RO System of 50LPH capacity i/c making plubming connection and interconnection with pipe, pipe accessories complete etc as reqd. 71 Supply and installation of automated switching on/off device for level monitoring in existing water cooler with testing, commissioning etc complete as reqd. 72 Supply and fixing of pre filter bowl assembly with complete tesing and commissioning etc as reqd. 73 a) Pre Filter Assembly 74 Dismantling of existing old/damaged DB, conduit, cable, angle iron, flood light on terrace i/c repair of damage during dismantling work etc as reqd. 75 Credit for dismantle materials 76 Assorted :Ceiling Fans 77 Assorted :Switch/socket/regulator (Piano/Modular) 78 Assorted: SP /DP MCB upto 63 A 79 Assorted : SP MCB DB 80 Assorted : copper Wirewith insulation 81 Assorted : MS conduit 82 Assorted : GI Box with modular plate/phenolic sheet 83 Assorted : LED batten/Downlighter/fl. Fitting