Tender For Provn Of Certain Work Services At Sarmat Range Af Stn Jamnagar; 1.01 Sch `A’ Part I : Design and Construction of LHQ building and Sanitary Annexe with permamnent specification such as RCC framed structure, RCC roof, ATT, PCC block masonary, WPT, mosquito proofing, camouflage painting, internal services etc complete all specified and shown in drawing. Note for item No 1.01 (i) Plan, Elevation, Section, Schedule of finishes and connected TD drawing is attached herewith.(ii) Schedule A Part-I not pre-price by MES and bidder shall be insert their lump-sum amount in green coloured field under Col-6 only(iii) Structure design of building, Structural drawing and complete estimate prepared by the contractor based on architectural Plan, elevation, section, schedule of finishes and connected TD drawing.(iv) For designing the foundation conducting structure is designed based on considered SBC of 30 T/SQM at depth of 1.50m below natural ground level as per soil investigation report. 1.02 Sch `A’ Part I : M&L On site LLDPE septic tank 10 users conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified. 1.03 Sch `A’ Part I : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M-25/ SFRC cover, 2.4 M dia X 3.0 M effective depth interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 3.0 M effective depth Complete all as specified and shown on drawing No CEAA/TD/80 Sheet 1/2 to 2/2. 2 Lump sum price worked out for (SITE CLEARANCE, EXCAVATION AND EARTH WORK) as listed in Sch `A’ Part II 3 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch `A’ Part III. 4 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch `A’ Part IV. 5 Lump sum price worked out for ROAD/PATH/CULVET as listed in Sch `A’ Part V. 6 Lump sum price worked out for External Electrification as listed in Sch `A’ Part VI. 7 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch `A’ Part VII. 8 Lump sum price worked out for BOUNDARY WALL/FENCING/GATE as listed in Sch `A’ Part VIII. 9 Lump sum price worked out for SUMMER APPLIANCE as listed in Sch `A’ Part IX. 10 Lump sum price worked out for DEMOLITION OF CERTAIN BUILDING (B/R & E/M) as listed in Sch `A’ Part X. 11 SCHEDULE A PART - XI (MISC ITEMS)(Note for items here in after: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES) 12 Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode).Air conditioner will have following conditions:-(i) Refrigerent - R 410a (ii) EER - min 5 w/w (5 star rating)(iii) Tonnage - 2(iv) Indoor Noise Level - Not more than 48 Db(v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter(vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode (h) MS bracket for outdoor unit (I) copper pipe duly imvlated proper indoor unit to outdoor unit complete as per site requirement.All specification will be as per IS-1391 (Part 2) 1992Room Air Conditioners 13 Supply & Fixing for Voltage stabilizer for automatic operation single phase as per BIS 8448: 1989 reaffirmed 2003 air cooled, digital display, copper wound, wall mount, indoor type with digital voltmeter & designed for input voltage variation between 140 to 280 Volt with output voltage stabilised at 220 volt ± 9% with time delay relay (TDR ) of 2 to 3 minutes and high low voltage cut off.Capacity 5 KVA complete all as specified and directed 14 M&L for Providing and applying 2.5mm thick road marking paint (retro-reflective with glass beads @ 250 gms per sqm) of approved shade / colour using hot thermoplastic material by fully / semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc complete as per direction of Engineer-in-charge and accordance with applicable specifications. 15 M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider. 16 Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat of size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed. 17 M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT Cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed. 18 Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 50 to 95 Sqmm all as specified and as directed.