| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) upto 2.25m deep including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in charge |
| 3 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundations filling in mass concrete all as specified. |
| 4 | M&L for brick work with sub- class \"B\" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) all as specified |
| 5 | M&L for RCC M25 grade (Design mix) (with 20 mm graded stone aggregate) as in foundation, footing & plinth beam etc complete all as specified and directed. |
| 6 | M & L for RCC M25 grade (Design mix)(with 20 mm graded stone aggregate) as in columncomplete all as specified and directed. |
| 7 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface all as specified & directed by Engineer in Charge. |
| 8 | Rough finished Formwork to sides of pillars, posts, struts, columns and stanchions circular on plan |
| 9 | M&L for TMT steel bars 10mm dia and over to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed by Engineer in Charge. |
| 10 | All as per item Serial No 9.00 here in above but 5mm dia & over upto and including 10mm dia in stirrups, spacers and binders. |
| 11 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified. |
| 12 | M&L for Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in copingand including necessary form work weathering slightly rounded or chamfered angles and throating as directed |
| 13 | M&L for Providing precast cement concrete louvres and jallies, set in cm 1:4type B-0 1:2:4 (12.5mm aggregate) 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified and directed. |
| 14 | M & Lfor rendering 15mm thick on fair faces of brick or concrete wall surfaces in cement mortar 1:4finished surfacesfair & even using WPC (Water Proofing Compound) as per manufacturers instructions complete all as specified and directed.Note : WPC measured and paid separately. |
| 15 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 16 | S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connectionssimilar work conforming to Fe-410-W(Gde- E-250) quality- B, with riveted, bolted or welded atachment complete all as specified and directed. |
| 17 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. and similar work conforming to Fe-410-W(Gde- E-250) quality- B, with riveted, bolted or welded atachment complete all as specified. |
| 18 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified. |
| 19 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof ridge, fixed with self tapping screws, complete all as specified. |
| 20 | S&F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 21 | S&F 10mm thik PVC insulation panels of size 600x600 mm with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing |
| 22 | S&F Anodised aluminium snap grid frame work of size 605x605 mm for false ceiling all as specified |
| 23 | Material & Labour for Preparing new plastered or unplastered surfaces and applying Two coats of 100%Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and as directed. |
| 24 | M&L for preparation for new steel untreated surfaces of any description, over 10 cm in with of girth, not otherwise describedtwo coats of synthetic enamel paint over a coat of red oxide zinc chrome primerall as specified. |
| 25 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting outin soft/loose soil all as specified |
| 26 | M&L for Hardcore of guage exc 63mm but not exc. 100 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified. |
| 27 | M&L for PCC1:3:6 type C2 using 40 mm graded stone aggregate as in floor 75 mm thick complete all as specified. |
| 28 | M&L for colured Virified Ceramic tiles double charged 7-8mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm not exceeding1.0 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 29 | M&L for Coloured rubber moulded Chequred cement concrete tiles 300 x 300 x 25mm thick, set, jointed and pointed in grey cement mixed with pigments in floors, over 20mm screed bed in CM 1:6, complete all as specified and directed. |