| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan ),including getting out the excavated soil and disposal of surplus earth upto 50 m including dressing of sides and ramming of bottoms, lift upto 1.5 m as directed by Engineer-in- Charge as per dar-2.8.1 |
| 2 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300mm apart i/c drilling 12mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor with Chlorpyriphos/Lindane E.C. 20% with 1% concentration.as per PWD-2.35.3 |
| 3 | Providing and laying in cement concrete 1:4:8 (1 cement:4 coarse sand:8 stoneballast 40 mm size) and curing complete. As perDsr no-4.1.8 |
| 4 | Earth filling available excavated earth (excluding rock)in tranches, plinth,sides of foundation etc. in layars nat exceeding 20cm in depth , consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m i/call DSR No-2.25 |
| 5 | Sandfilling available excavated earth (excluding rock)in tranches, plinth,sides of foundation etc. in layars nat exceeding 20cm in depth , consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m i/call DSR No-2.25 |
| 6 | Brick work wthi common burnt clay (non modular) bricks of class -150 in foundation and plinth with(1:6) cement and C/ sand mortar i/c allas per DSR No-6.1.2 |
| 7 | Brick work wthi common burnt clay (non modular) bricks of class -150 in foundation and plinth with(1:4) cement and C/ sand mortar i/c allas per DSR No-6.1.1 |
| 8 | Providing and layingcement concrete in retaining walls,return walls, walls (anythickness) i.c. attached pilaters, columns, piers, abutments, pillars, posts, struts, bullresses, string or lacing courses, parapets, coping, floor etc.of specified grade excluding the cost of centering and shuttering - All work up to five level : 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3graded stone aggregate 20 mm nominal size). As per PWD-5.3 |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. as per D.A.R. NO-5.22.6+Ch.no-1 item no-1005107.85+5550 |
| 10 | Brick work wthi common burnt clay (non modular) bricks of class -150 in superstructure above plinth level up to floor V level in all shapes and sizes in.(1:6) cement and C/ sand mortar i/c allas per DSR No-6.4.2 |
| 11 | Providing and fixing angle iron frames for doors , windows and ventilators of mild steel angle section of size 35x35x5mm joint mitred and welded by angle iron 35x35x5mm or 35x5 mm flat pieces to the existing Angle Iron chaukhat (40x40x5 mm) . As per PWD-10.31 |
| 12 | S/F of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing of woodencleats and stoppers and including fixing and adjustment of hings bolts locks handles springs fitting with necessary screws complete. As per PWD-9.21.1 -35 mm thick |
| 13 | Supply an fixing glass panes of 4mmthick glass equuivelent ISI mark quality putty brades and springs andi/c all comp. As per PWD-10.30.1 |
| 14 | 40MM thick cement flooring with concrete hardener topping under layer 40mm thick cement concrete 1;2;4 cement, c/s and 40mm stone gritt as per pwd dsr no- 11.3 |
| 15 | Providing and laying Vetrifiedfloor tiles of size 600x600 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. As per PWD-11.41.2 |
| 16 | Centering & shuttering including strutting, propping etc. and removal of form for |
| 17 | Centering & shuttering including strutting, propping etc. and removal of form for |
| 18 | Centering & shuttering including strutting, propping etc. and removal of form for |
| 19 | P/F of 110 mm dia wall face unplasticised rigid PVC rain water down pipe complete with rose heads bends as DSR NO-12.41.2 |
| 20 | 15 mm thick cement, sand plaster in 1:6 cement & C/sand mortar as per CPWD-13.5.2 |
| 21 | 12 mm thick cement, sand plaster in 1:6 cement & C/sand mortar as per CPWD-13.4.2 |
| 22 | Providing and Applying white cement based putty average thickness of 1 mm of approved brand over the plasterd wall surface.as per CPWD-13.80 |
| 23 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). As per PWD-13.47.1 |
| 24 | Providing and Applying white cement based putty average thickness of 1 mm of approved brand over the plasterd wall surface.as per CPWD-13.80 |
| 25 | Painting steel work with deluxe multi surface paint to give an even shade two or more coat applied as per incl. material,labour and T&P etc. required for proper completion of work, as per CPWD-13.48.2 |
| 26 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.as per elc.sor no-1149 |
| 27 | Wiring for light points /fan point/exhaust fan point /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surfacemultistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. DSR No. 1.1.1 Group(A) |
| 28 | Wiring point for plug with 1sq mm PVC insulated single core copper conductor cable in PVC condute with 1.5 sq mm FR PVC Complet in all respect SI No. 134 (C) |
| 29 | S/F of switch box made up of 16 SWG (1.5 mm) thick M.S. Sheet of200x250x65mm size duly painted with red oxide primer require for proper completion of work. SI. No. 162 |
| 30 | S/F of surface / flush mounting 8 ways S.P.N. Distribution board without MCB complete in all respect SI No. 1024 cat-b |
| 31 | S/F of power plug 20 A/ 250 V flush type switch and 5 pin 20 A/ 250V flush type universal socket in sutaible M.S. Box of 175x100x65 mm complete in all respect SI No. 1139 A |
| 32 | S/W of LED tube light with batten suitable for up 1x22 watt LED tube light complete in all respect SI No. 1413 AAA |
| 33 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductorDSR No. 1.7.2 |
| 34 | Supply and wiring of submain 2 number 1.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductorDSR No. 1.7.1 |
| 35 | Supply and wiring of submain with 4 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in40 mm dia heavy duty (2mm thick) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects DSR No. 1.7.8 |
| 36 | Basic price for 1200mm sweep BLDC Ceiling fan i/c all accessories /fitting /supports etc. DSR No- 4400 |
| 37 | Add 18% GST |