Tender For Addition Alteration To Building No P-36 At Nho Dehradun; 1 Demolition of PCC in ground floorand pavings not exc 15 cm thickness below or above ground levelincluding removal of rubbish out side MOD land complete all as specified and directed. 2 M&L Roughnening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per sqm. Complete all as specified and directed. 3 Demolition of concrete of any description and in any position not otherwise specifically provided for Cement concrete ( reinforced) including removal of debris etc to a distance out side MoD land complete all as specified and directed. 4 Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 5 Dismantling of boarding of any deescription and fixed in any position with nails complete all as specified and directed. 6 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to storeand rubbish off the premises from MoD land complete all as specified and as directed. 7 Dismantling of timber scantling 40 sqcm and over in section, in any position as in framed work complete all as specified and as directed. 8 Dismantling of plain or corrugated steel sheeting, any gauge, thickness in roof coverings complete all as specified and directed. 9 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 10 Excavating in trenches nexc 1.5 m width and depth exc 1.5m but nexc 3m for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. 11 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. 12 Removal of surplus soil to a distance nexc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 13 Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. 14 Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of following size complete all as specified and directed:- 15 Area not exc 1.5 sqm each 16 Area exc 1.5 sqm but not exc 4 sqm each 17 Taking down shutters of any description, of following size complete all as specified and directed:- 18 Area exc 1.0 sqm but not exc 2.0 sqm each 19 Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :- 20 15mm bore 21 20mm bore 22 M&L for brick work with old size full bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. 23 M&L for brick work with old size half bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. 24 M&L Rolled mild steel in Compound girders andstanchions, lattice girders, aerialmasts, staging for water tanks andthe like includingcaps,bases, splices etc. built up from twoormorebeam or channel sections or angleswith plates, including all lattice bars,stiffeners, gusset plates, etc.complete all as specified and directed. 25 M&L for 15mm thick plastering onbrick work or concrete surfaces in CM (1:6)finished even and fair complete all as specified and directed. 26 M&L 15mm thick rendering cement mortar (1:4) mixed with liquid water proofing compound onbrick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. (WPC shall be paid seperately) 27 M&L for 10 mm thick plaster on roof,ceiling, chajja and roof parapet of CM (1:3) on RCCfinished even and smooth without using extra cementetccomplete all as specified and directed. 28 Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. 29 S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 30 S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. 31 S&F rolled mild steel section for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. 32 S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and or riveted or forged into spikes, framed, barred iron door, ladders, fencing work ect. conforming to Fe-290 Gde E-165 complete all as specified and directed.Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account. 33 M&L for 25 mm thick PCC (1:2:4) type B0(12.5 mm graded stone agg) as in sub floor of flooring complete all as specified and directed. 34 M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.Note : Joint to be provided at each interval of 3m and corner and cost of the same deemed included in quoted rate. 35 M&L Vitrified coloured double charged tiles 10-12 mm thick light shade (Square/Rectangular) area of each tiles n. exc. 0.36 Sqm, over and including 15mm thick screed bed in Cement Mortar(1:6) in flooring,set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. 36 M&L for Vitrified Coloured double charged tiles 10-12 mm thick(square/rectangular) light shade area of each tiles not exceeding 0.36 Sqm, as in skirting/dado, over and including 10 mm thick rendering in Cement Mortar(1:4)set and jointed in neat cement slurry and pointed in coloured cement to match complete 37 M&L for providing Non skid Endura coloured tiles 12-14 mm thick (square/ rectangular) area of each tile not exc 0.16 sqm over and incl 15mm thick screed bed in cement mortar (1:6) in flooring set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. 38 -ditto-as above but on verticalsurface over and incl 10mm thick rendering in CM (1:4) complete all as specified and directed 39 M&L for non skid, joint free, coloured ceramic tiles7-8mm thick (Square/Rectunglar), as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles laid with and including over 15mm thick screed bed in CM (1:6), area of each tiles shall be of following complete all as specified and directed :- 40 Area of each tile exc 0.06 Sqm but not exc 0.11 Sqm. 41 M&L for coloured, digital glazed ceramic tiles size 350x250x7-8mm or 450x300x 7-8mm thick as in dado/ skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over 10mm thick rendering in CM (1:3) all as specified and directed. 42 M&L for 18-20mm thick granite stone slab (of any type) work (table rubbed and mirror finish polished) with and including necessay notching, chamfering the edges in steps, jambs, pillars, window-cills, cooking platforms and like bedded over and including 15mm thick screed bed in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 43 S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with MS square tube, fixing in same opening complete as all as specified and directed. 44 S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top, bottom and side rails, MS frame shall be covered with heat molded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fixed in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site complete all as specified and directed. 45 S&F second class hard wood (sal) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. 46 S&F pressed steel frames made out of 1.25mm thick mild steel sheets for door with one or morerebatesincluding necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxideprimer including cutting holes and making goodin PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, of following size complete all as specified and as directed:-Note : 10mm deformed bar shall be provided in bottom portion in each frame. The rate for the same is included in rate quoted against this item. 47 125mm x60mm size 48 105mm x60mm size 49 S&F 35mm thick factory made second class hard wood glazed and skelton door shutter open rebated and prepared to receive glass or gauge etc divided into square with plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters as specified in SSR Part-I (2009) section 8 clause 8.20 (a). 50 S&F flush shutters, ISI mark, solid core construction with block board core and ply wood face panels, commercial type on both sides for following thickness complete all as specified and directed:- 51 35 mm thick 52 S&Fpowder coated aluminium glazed side hung double door shutters with anodised aluminium frame of section 100x44x1.5mm and shutter having style, top rail, lock rail and bottom rail of 84x44x1.5mm including 5.5mm thick tinted blind sheet glass ordinary quality with all necessary suitable push & pull plate/handle, screw, jointing cleats, rubber packing, aluminium snap beading and 1 No 200mm long Al tower bolt, 100 mm long 3 No Al butt hinges B-21 type, and one No mortice brass lock 100mm size 4 leaver (vertical type) complete all as specified and directed. 53 M&L 1st class Hardwood 40mm thick Plain,Framed, Half Panelled , Half Glazed shutters (any number of panels), with panels of timber flat on b oth sides (feather edged), or of veenered particle boards medium density, wood particle board with decorative face veeners: supplied and fitted to chowkhats complete all as specified and directed 54 M&L 4mm thick Sheet Glass, ordinary quality and glazing with wooden beading in square exc 0.5sqm in each pane. Frosted on one side incl NHO and Indian Navy crest etching complete all as specified and directed 55 S&F Aluminium powder coated three track sliding windows (with three sliding shutters, (One with and incl stainless steel wire mess and two with and incl 4mm thick sheet glass panes) aluminium sections not less than 1.1kg per meter for bottom track and top track and side track 0.98 kg per metre, bottom shutter frame 0.55 kg per metre, top shutter frame 0.47 kg per metre, shutter sides, 0.47 kg per metre and interlock sides 0.45 kg per metre including suitable nylon beading channel gasket, nylon rollers Maruthi lock with handles etc complete all as specified and directed by Engr-in-Charge. 56 S&F anosided aluminum powder coated window and ventilator side hung type without sash bar aluminium sections weighing 0.55 kg/ m incl necessary joining cleat, glazing clips, rubber packing, anodised aluminium snap beading, screw, anodised aluminium fittings such as peg stay 150 mm long (1 No) hinges type B-21 100 mm long(2 Nos) Suitable handle (1 No.) complete all as specified and directed. 57 S&F powder coated aluminium (min thickness of powder coating 50 micron) work for door, windows and ventilators and partitions (fixed portion) with extruded built up standard tubular sections/ appropriate Z section of approved make incl necessary gap filling up the gaps at junctions with EPDM rubber/ neoprene gasket etc complete all as specified and directed. 58 S&F in repair 18mm thick WPC board one side prelaminated and other side plain white colour as in cup boad shutters and frames, kitchen cabinet front shutter, partion, shelf & drawer, fixed with screws, solvent cement/ adhesive complete all as specified and directed. 59 Supply only MS butt hinge, medium weight, cold rolled and fixed of following size complete all as specified and directed:- 60 100 mm long 61 S&F stainless steel barrel tower bolts of extruded section (ISI Markd)of following size complete all as directed and specified:- 62 300 mm long 63 S&F stainless steel handles fabricated type, of following size complete all as directed and specified:- 64 150 mm long 65 100 mm long 66 S&F stainless steel sliding door bolt with hasp & Staple, bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of following size complete all as specified and directed:- 67 250mm long 68 S&F 150mm Stainless Steel Hasp and Staple, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-Charge. 69 S&F in repair Hydraulic Self Closing hinges 35mm of crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position complete all as specified and directed. 70 S&F in repair aluminium body door closer hydraulically regulated, designation No -3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight 61 to 80 Kg (ISI marked) complete all as specifiedand as directed. 71 S&F in repair 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed. 72 S&F floor doorstopper (ISI Marked) of aluminium alloy body andtongue anodised, with hard drawn steel spring, fixed in floor of following size complete all as specified and directed :- 73 140mm long (overall length of cover plate) 74 S&F for Stainless steel curtain rod, 25mm dia with fixing brackets and decorative type knobs both side of each rod, incl taking down old curtain rod or pelmet boxes complete all as specified and directed. Note :- Measurement will be taken between end point of knobs. 75 S&F Dust/Snake guard aluminium strip in doors of size 40x2mm with rubber at strip bottom complete all as specified and directed. 76 S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- 77 15mm bore 78 20mm bore 79 Refixing old galvanised steel water tubing, with all new fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- 80 15mm bore 81 20mm bore 82 M&L for cutting chases in brick wall, pinning in and making good in cement mortar (1:3) to match with existing surface for following girth complete all as specified and as directed :- 83 Cutting not exc 10cm girth. 84 S&F in repair 20 mm bore gun metal globe or gate valves, (ISI marked), with iron wheel head, screwed both ends for iron pipecomplete all as specified and directed. 85 S&F in repair 75 mmdia PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in flooror fixed to wall complete all as specified and as directed. 86 S&F in repair PVC (SWR) floor trap, out let dia 75mm, plain with grating including jointing with solventcomplete all as specified and as directed. 87 S&F in repair 75 mm bore PVC (SWR) vent cowl of following size complete all as specified and as directed 88 S&F in repair 450mmPVC connection 15 mm size with PTMT nut of following length complete all as specified and directed. 89 S&F chromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed. 90 S&F 15mm dia brass chromium plated pillar tap long body with fly nut capstan head screwed for 15mm bore dia of pipe complete all as specified and directed. 91 S&F 600x450x5mm thick looking mirror bevelled edge of selected quality glass fixed with stainless steel glass fastner complete all as specified and directed. 92 S&F in repair CP health faucet with 1m flexible tube and wall hook complete all as specified and directed. 93 S&F in repair 15mm bore stopvalve, cast copper alloy, fancy type chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. 94 S&F in repair toilet paper holder of brass, chromium plated, fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. 95 S&F in repair Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.complete all as specified and directed. 96 S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc. 97 S&F in repair vitreous china wash down water closet pan (pedestal pattern), white/ivory, with and including plastic seat and cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., completeall as specified and directed. 98 S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approvrd by GE complete all as specified & directed. 99 S&F in repairs PVC water storage tank triple layer cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed. 100 M&L for three coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed.Note :-The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. 101 M&L for preparing old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coats of white wash complete all as specified and as directed. 102 M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700)along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller over a layer of wall care putty to make the surface smooth all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge.Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted.(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GEbefore application of distemper for each building.(v).The colour / shade will be all as approved by GE. 103 M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700)along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building.(v).The colour / shade will be all as approved by GE.(vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor. 104 M&L two coats of weather proof emulsion paint wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make in newly plastered surface over a coat of primer incl preparing the surface complete all as specified and directed by Engr-in-Charge. 105 M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. 106 M&L for twocoats of synthetic enamel paint over a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed. 107 M&L for preparation of old painted surface of wood and wooden based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed. 108 S&F false ceiling with Semi perforated 10mm thick Square edged GRG False Ceiling tiles at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Nomocombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120grams per Sqm incliuding both sides) comprising of main-T runners of size 15x32mm of length 3000mm, cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod up to 2000 to mm length and L-shape level adjuster os size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engr-in-Charge. 109 Removal of existing roof treatment i.e. APP Membrane, brick tiling including concrete padding and benching and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material without damaging existing serviceable structure complete to receive new roof treatment including rubbish off the premises upto a distance exc 250 mtr but n.exc 500 mtr complete all as specified and directed. 110 M&L forPCC (1:2:4) Type B-0 (using 12.5mm graded stone aggregate) padding mixed withliquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/mortar to old surface as per manufacturer direction and finishing the surface even and smooth (without usin extra cement) as in roof padding/Sunken floor, kerb/bencing alongwith parapet including rounded, chamfered on edges complete all as specified and directed by Engr-in-Charge.(Note : Proportion of mix and method of mixing of approved concrete admixture should be applied as per manufacturers printed instructions) 111 M&L for rendering 10mm thick screed bedding in CM (1:3) mixed with acrylic bonding compound SBR Latex liquid polymer finished the surface even and smooth without using extra cement complete all as specified and directed .(Note : Prpportion of mix and method of mixing of approved liquid water proofer admixture should be applied as per manufacturers printed instructions) 112 M&L for water proofing treatment to non-accessibleroof slabwith APP based modified polymeric membrane as per manufacturer’s instructionswith following course of description below :-(a)Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturers instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : (i) The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor. (ii) The work is required to be carried out at non-accessibleroof slab for double storeyed.The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. 113 M&L for cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed. 114 M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 115 M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 116 M&L for RCC (1:2:4) Nominal mix(20mm graded aggregates) as in beam, lintel upto 1.5m span including formwork of rough finish surfsce complete all as specified and directed. 117 S&F 5.5-6 mm thick PVC heavy grade hollow profile designer sheet strips & channel feathered at edges of approved quality and design PVC Wall/Ceiling Panelling including matching PVC angles at all window corners, jambs & cills complete all as specified and directed. 118 Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed.Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. 119 Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as specified Note:- Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates( ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. 120 Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted ratesii)If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. 121 One 3pin/5pin 5/6 Amps socket out let on same boardwith other switches ,with cables 1.5 sq mm size , complete all as specified and directed. 122 One 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed . 123 All as per item No 100 abovebut with 4.0 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed. 124 S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed. 125 Supply and fixing switch modular , one-way 16Amps,1 module 240 Volts AC all as specified and directed by Engr- in-charge. 126 Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed. 127 Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed 128 Supply and fixing bell pushmodular flush type single pole one way 6 Amps, 1 module all as specified and directed 129 S&FBell ding dong Type , 240 Voltscomplete all as specified and directed. 130 Supply and fixing ceiling rose surface bakelite 65x25mm dia having three terminals ISI marked all as specified 131 Supply and fixing batton/angle holder insulated body with back plate, suitable for batten fittingsall as specified & directed. 132 Supply and fixingLED lights fitting 1X20 watt ,4 ftwith extruded aluminium housing heat sink, environmental friendlyenergyefficienttranslucent diffuser with LED light source,2400 Lumens( minimum)coefficient colour temp 6000°K to 6500 °K, surge protection range ≥ 2.5KV, voltage protection range-120-300VAC,2 years warranty ,system efficacy not less than140Lm/Watt for the fitting, power factor >.95,total harmonic distortion< 20% color rendering index>80, fixed on site with all accessoriesincluding connecting up with three core flexible copper conductor cable of suitable size from ceiling rose all as specified & directed 133 Supply and fixingenergy efficientLED lights fitting, 9 watt , 230 Volt, of 600 mm length,CCT 6000ºKto 6500° K , decorative ultra slim linear LED lighting fixture with extruded aluminium housing heat sink, environmental friendly, energy efficient LED light source more than1200 lumens , wall mounted mirror batten, integrated electronic driver, system efficacy not less than 140 lumens /watt CCT 6000to 6500°K , surge protection range ≥ 2.5 KV , voltage protection range 120-300 volt AC, power factor > 0.95 total harmonic distortion< 20%, colour rendering index > 80, fixed on site with all accessories including 2 years warranty connecting up with three coreflexible copper conductor cable of suitable size from ceiling rose complete all as specified& as directed.. 134 Supply and fixingin replacement ofLED luminaire 600mm X 600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and asdirected. 135 S&Fonly round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 136 Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with 01 No, RCCB 20 Amp, , 240 Volts,AC Complete all as specified.(Note - Cost of cutting chases for enclosure concealed in wall of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates 137 S & F wall fan 400 mm sweep 240 volts Ac 50 Hzcomplete all as directed. 138 S & F ceiling fanBLDC Type 1200 sweep 240 volts Ac 50 Hzcomplete all as directed. 139 S & F PVC fresh airfan 240 volts Ac 50 Hz 250 mm sweep PVC body including louvers and cutting as required size and shape complete all as directed. 140 Supply and fixingLED building security light 1X30 W housing made out of pressure die-cast aluminium alloy with toughened glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection up to 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 130 Lumens/watt, power LED should be of more than 01 wattCCT should be between 5700° K- 6500° Kincluding fixed onwall with 02 Nos MS clamp made out of 40X6 mm FI and bracket made out of 32 mm dia light grade GI pipe not less than 0.90 mtr long bend to shape completeallas Specifiedand directedincluding connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from terminalbox to light fittingscomplete all as specified and as directed by Engr-in-Charge (i)the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii)The fitting should have BIS, CRSno 141 Supply and fixing Vertical type TPN DB, 4 way ( DPX 125+12), as per IS 8623, IP - 43 protection, universal mounting with 200A Copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB 125 Amps as incomer and SP MCBs 12 Nos & making necessary electrical connection for incoming and outgoing cables, with copper lugs complete all as specified and directed 142 Supply and fixing MCCB 160 Amp, TPN, 415 volts, ultimate breaking capacity (ICU) - 36 KA, confirm to ICU 100 % ICS complete all as specified and directed 143 Supply or fixing MCB TPN 415 volts 63 Amps having ruptuing capacity 10 kA,C curve type complete all as specified and directed 144 Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar all as specified and directed . 145 Supply and fixing MCB SP 5 to 32 Amp B series 10 KA repturingcapacity complete all as specified. 146 Supply and fixing MCBSPN40 Amp 240 V AC 10 KA repturingcapacitycomplete all as specified. 147 Supply and fixing in repair sub main wiring two single core 4 sq mm PVC insulated unsheathed multi stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionall as specified and as directedNote:- Two runs of multi stranded copper conductor cableand one run of earth wire including PVC conduit will be measured as a one length. 148 Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. 149 Supply, installation, commissioning and testing of Hi wall split type airconditioningunits indoor/outdoor complete with cordless remote control unit and with in built in Heating and cooling arrangement air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5TR (4500 Kcal/Hr) complete of comprising of the following:-(a) Room evaporative indoor unit with three speed blower fanof appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water.(b) Out door condensing unit of capacity 4500 K Cal / Hrs comprising of 01 no. compressor of 1.5TR capacity withcondenser fan motor of appropriate capacity - 01 No, air cooled condenser of 1.5TR capacity - 01 No,shall be installed out side the building.(c). Refrigerant copper pipe for suction & discharge linewith insulation, condensing water drain pipe& protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed.(d) Making good the disturbed surface to match the existing surface after plugging the hole etc .Note :- (i).Cutting holes in walls/windowof any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done.The unit rate quoted by contractor shall deemed to be inclusive of this aspect.(ii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer inclusive in above rate.(iii)copper piping/with insulations and drain piping shall also deemed to be inclusive in quoted unit rate. 150 Supply, installation, commissioning and testing of voltage stabilizer of capacity 5 KVA (20 Amps), for automatic voltage correction of 20 volts per second, single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 220 volts + 2.5 % and High / low voltage cut off with facility of delayed start time of 3 minute complete all as specified and and directed.