Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-09-2025 |
| 2 | 09-08-2025 | BOQ Corrigendum | BOQ | 25-08-2025 |
| Sl. No. | Item Description |
| 1 | Removal ofexisting roof treatment i.e APP membrane and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material complete all as specified and directed.Note for all Item of roof treatment :- The work is required to be carried out at non-accessible roof for double storey. The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items . |
| 2 | M&LPCC (1:2:4) type B-0, using 12.5 mm graded stone agg mixed with SBR Latex liquid polymer as water proofing compound (mixed as per manufacture instructions) over and including one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction and finishing the surface even and smooth without using extra cement as in roof padding / sunken floor to receive water proof treatment complete all as specified and directed.Note :- The cost of SBR latex deemed included in quoted rates. |
| 3 | M&L for water proofing treatment to non-accessibleroof slabwith APP based modified polymeric membrane as per manufacturer’s instructionswith following course of description below :-(a)Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer\"s instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance |
| 4 | Demolition of PCC in ground floorand pavings not exc 15 cm thickness below or above ground levelincluding removal of rubbish out side MOD land complete all as specified and directed. |
| 5 | M&L for PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radiaus of 75 to 100mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed withintegral water proofing compound as per manufactur direction )Note :- Integral water proofing compound(WPC) will be measured and paid seperately. |
| 6 | M&L for two coat of acrylic polymer modified cementitiousflexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge complete all as specified and directed.Note : Ponding test :- After water proofingcoating, ponding test willl be done for ponding for 48 Hrs. |
| 7 | M&L for 15mm thick protection plasterin CM (1:4) as infloor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufacturer direction ) complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately.. |
| 8 | M&L for 40mm dia GI pipe, medium grade, as in spout pipe, projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge complete all as specified and as directed. |
| 9 | M&L for PCC (1:5:10) Type E2 ( using 40 mm graded stone aggre-gate) as in foundations, sunken portion filling and mass-concretecomplete all as specified and directed. |
| 10 | M&L for 30mm thick PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate,as in floor mixed with polymer modified repair mortar (SBR Latex liquid polymer) as per manufacturer direction complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately. |
| 11 | Supply only SBR Latex liquid polymer of approved make complete all as specified and directed. |
| 12 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. |
| 13 | Demolition and breaking up drain pipes (PVC/ SGSW/ AC/ RCC pipe) of following bore of pipe, set in cement mortar complete all as specified and as directed:- |
| 14 | 100mm bore |
| 15 | 150mm bore |
| 16 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed :- |
| 17 | 110 mm bore |
| 18 | 75 mm bore |
| 19 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of following size complete all as specified and as directed :- |
| 20 | 110 mm bore |
| 21 | 75 mm bore |
| 22 | S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of following size complete all as specified and as directed :- |
| 23 | 110 mm bore |
| 24 | 75 mm bore |
| 25 | S&F PVC (SWR) bends with access door any radius of following size complete all as specified and as directed :- |
| 26 | 110 mm bore |
| 27 | 75 mm bore |
| 28 | S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed. |
| 29 | S&F PVC (SWR) reducers of size 110 mm x75 mmcomplete all as specified and directed. |
| 30 | S&F PVC (SWR) junction single, (single T) equal or unequal of following size complete all as specified and as directed :- |
| 31 | 110 mm bore |
| 32 | 75 mm bore |
| 33 | S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 34 | S&F PVC (SWR) multi floor trap,in repair out let dia 75mm, plain with grating including jointing with solventcomplete all as specified and as directed. |
| 35 | S&F PVC (SWR) P trap, in repair out let dia 110mm, plain with grating including jointing with solvent complete all as specified and as directed. |
| 36 | S&F stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for following bore of pipe complete all as specified and directed :- |
| 37 | 100mm bore pipe |
| 38 | 75mm bore pipe |
| 39 | S&F PVC (SWR) floor trap,in repair out let dia 75mm, plain with grating including jointing with solventcomplete all as specified and as directed. |
| 40 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided forincluding removal of debris etc to a distance out side MoD land complete all as specified and directed. |
| 41 | M&L for RCC (1:2:4) type B1 Nominal mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed. |
| 42 | M&L for RCC (1:2:4) type B1 Nominal mix (using 12.5 mm graded stone aggregates)as in Chajjas/ fins/ facia of roof slab incl form work and one coat of SBR latex as bonding of old concrete to new concrete complete all as specified and directed. |
| 43 | M&L for formworkfor rough finish surface of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed. |
| 44 | M&L for precast RCC (1:2:4) type B1, (using 20mm graded stone aggregates) as in cover slab (for manholes) and set in CM (1:4) including necessary fair finish formwork complete all as specified and directed. |
| 45 | M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 46 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed. |
| 47 | M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 48 | M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.Note : Joint to be provided at each interval of 3m and corner and cost of the same deemed included in quoted rate. |
| 49 | M&L for PCC (1:4:8) Type D2 ( using 40 mm gradedstone aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath complete all as specified and directed. |
| 50 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/disintegated rocks comlete all as specified and directed. |
| 51 | M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spread,and levellled in layers water andrammed to a true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed. |
| 52 | M&L for 60mm thick coloured rubber moulded glossy finish machine pressed precast concrete interlocking paver block,M-35 Grade with pre-polished, coloured/ laquar finish any shape and size, as approved confirming to IS 15658-2006 with and including over 50 mm thick stone dust/ sand cushining complete all as specified and directed. |
| 53 | M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb/ benching/ coping, bed plates, for fixing of hold fast,water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. |
| 54 | Removal of surplus soft disintigrated rock to a distance n\"exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 55 | Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of following size complete all as specified and directed:- |
| 56 | Area not exc 1.5 sqm each |
| 57 | Area exc 1.5 sqm but not exc 4 sqm each |
| 58 | M&L for factory made 35mm thick 100% solid WPC window glazed shutter and Gauzed (wire mesh) shutter 95 mm x35mm thick. Made from WPC material with density not less than 800 kg/cum. All four corner are fusion welded & screwed with 8 x 50mm self-screws for additional strength. After joining all 4 corner clear space to be paneled with 5mm thick glass / S S mosquito mesh after glazing of inside of shutter 10 x 12mm pvc “L” shape bead to be nailed or sticked with shutter. Provided 2 Nos SS hinges of 100 mm, 1 Nos aluminium handle of 125 mm , 2 Nosaluminium tower bolt of 125mm and 01 peg stay for each shutter (Glazed and Gauzed) incl factory made 100 % solid WPC window frame 125 mm x 65 mm double rebated frame & mullion 125 x 80mm. made from WPC (Single extruded process) material comparising of virgin PVC polymer of K value 57-60 (suspension grade), calcium carbonate and natural fibers (Wood powder/ rice husk/wheat husk) and nontoxic additives fabricated with meter joints after applying PVC solvent cement & screwed with fully body treated star headed screws having minimum frame desity not less than 800 kg /cum, having good screw holding capacity (screw withdrawal strength of (min 990N). Minimum compressive strength of 58 N/mm2. Modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / mosquito proof & fire retardant & fixed in position with fasteners / hold fast of required size. Window shall be provided with MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat including painting with countersunk holes at both vertical ends. Gap between the bars should not be more than 125mm. All as per specification drawing as directed by Engr-in-charge.Note - (i) Glazed and Gauzed shutter both are deemed in this quoted rate(ii) Glass pane, wire mesh and grill are deemed in this quoted rate |
| 59 | M&L for 30mm thick factory made solid WPC (wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texteure, including stainless steel wire mesh shall be fixed with 15 x15 mm square tube in side rails with screwing 8 x 28 heat metal zink coated screw can be remove or fix again after changing of wire mesh, when needed. The density of the shall be as per manufacture instruction compete all as specified and directed. |
| 60 | M&L for 35 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk stainless steel screws complete all as specified and directed.Note: stainless steel butt hinges and necessary stainless steel screws shall be paid separately. |
| 61 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable andvariation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately. |
| 62 | 65mm x100mm size |
| 63 | 65mm x 125mm size |
| 64 | M&L factory made single extruded WPC (Wood Polymer Composite) sM&L factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having olid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. Note- S S Butt hing measured and paid separately at relevant item |
| 65 | M&L factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having |
| 66 | Sectional area exc 13 sq cm but not exc 25 sq cm |
| 67 | S&F stainless steel barrel tower bolts of extruded section (ISI Markd)of following size complete all as directed and specified:- |
| 68 | 300 mm long |
| 69 | 200 mm long |
| 70 | S&F stainless steel handles fabricated type, of following size complete all as directed and specified:- |
| 71 | 200 mm long |
| 72 | S&F stainless steel sliding door bolt with hasp & Staple, bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of following size complete all as specified and directed:- |
| 73 | 300mm long |
| 74 | S&F stainless steel, non magnetic butt hinge (ISI Marked) and fixed of following size complete all as specified and directed:- |
| 75 | 100 mm long |
| 76 | S&F floor doorstopper (ISI Marked) of aluminium alloy body andtongue anodised, with hard drawn steel spring, fixed in floor of following size complete all as specified and directed :- |
| 77 | 150mm long (overall length of cover plate) |
| 78 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or wire staples complete all as specified and as directed. |
| 79 | S&F in repairs for stainless steel non magnetic curtain rod of 25mm dia with and including fixing brackets and decorative type knobs (as approved by AGE (I)/ GE both side of each rod complete all as specified and directed.Note: - Measurement will be taken between end point of knobs. |
| 80 | S&F aluminium door seal upto 1200mm long on bottom of door complete all as specified and directed. |
| 81 | S&F 18mm thick PVC/ WPC solid, both side prelam celluca plyboard for cabinet boxes & shutter, cup boards, drawer, etc with shelf and shutter incl lipping to edges of exposed surfaceincluding provn of fixing arrangement complete all as specified and directed. |
| 82 | S&F continuous (piano) hinges, mild steel bright finish or electro galvanised width of flaps (when open) 30mm complete all as specified and directed. |
| 83 | S&F Stainless Steel Hat and coat hooks, solid body, 175 mm to 250 mm complete all as specified and directed. |
| 84 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 85 | M&L for brick work with old size half bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 86 | M&L for brick work with old size full bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 87 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. |
| 88 | M&L for 5mm thick rendering on fair faces surface in cement plaster (1:3) as in ceiling and fininshed surface even and smooth with out using extra cement complete all as specified and directed. |
| 89 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and smooth with out using extra cementcomplete all as specified and directed. |
| 90 | M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick in CM (1:6), and IInd layer 5mm thick in CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed.Note :- WPC (Liquid type) shall be measured and paid separately as supply only. |
| 91 | M&L for preparation of new surfaces of false ceiling perforated boardand applying two coats of oil emulsion distemper over a coat of primer with out painting grid portion complete all as specified and as directed. |
| 92 | M&L for preparation ofnewly plastered surfaces on walland applying two coats of oil emulsion distemperon plastered surfaces over and including 1mm thick of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed. |
| 93 | M&L preparation of new orplastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 94 | M&L for preparation of old decorative surfaces of false ceiling board in snap grid frame work and applying twocoat of oil emulsion distemper over alkali resistance for primming to distemper for smooth finish of wallcomplete all as specified and as directed. |
| 95 | M&L for preparing old decorated plastered or unplastered surfaces of wall, pillasters, cornices etc by complete removal of existing treatment by scrapping, washing, rubbing down & stopping at any heightetccomplete all as specified and directed. |
| 96 | M&L preparation of new orplastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 97 | M&L for preparation of old plastered surfaces on walland applying two coats of oil emulsion distemperon plastered surfaces over and including 1mm thick of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed. |
| 98 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to storeand rubbish off the premises from MoD land complete all as specified and as directed. |
| 99 | Roughening surface of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and as directed. |
| 100 | M&L for Non skid, joint free coloured ceramictiles of any design and pattern, 7 to 8 mm thick, of following size, as in floor etc with and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 0.5% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1300 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed :-Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I). |
| 101 | Area of each tile exc 0.06 Sqm but not exc 0.11 Sqm. |
| 102 | Area of each tile exc 0.18 Sqm but not exc 0.36 Sqm. |
| 103 | M&L for coloured glazed ceramic tiles of any design and pattern, 300 x 450 x 7 to 8mmthick, as in dado etc including 10mm thick rendering in CM (1:4), set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed.Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) |
| 104 | M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror finish polishing over and including 20 mm thick screed bed in cement mortar (1:4) complete all as specified and as directedNote:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.) |
| 105 | Description same all as per item No 91 above but, as in skirting/ dado (10-12mm thick Kota stone) over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed. |
| 106 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed inany mortar and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 107 | M&L for 18-20mm thick pre polished Udaipur green stone (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like bedded over and including 15mm thick screed bed in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 108 | S&F rotational moulded polyethylene water storage tank, Capacity 1000 Ltrs double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings,completeall as specified and as directed. |
| 109 | S&F 20mm bore ( minimum weight 210gms)ball valve high pressure ofPTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes or brass ferrule and fixed complete all as specified and as directed. |
| 110 | Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :- |
| 111 | 15mm bore |
| 112 | 20mm bore |
| 113 | 25mm bore |
| 114 | M&L for cutting chases in brick wall, pinning in and making good in cement mortar (1:3) to match with existing surface for following girth complete all as specified and as directed :- |
| 115 | Cutting not exc 10cm girth. |
| 116 | S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- |
| 117 | 15mm bore |
| 118 | 20mm bore |
| 119 | 25mm bore |
| 120 | Refixing old galvanised steel water tubing, 20mm bore with all new fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenchescomplete all as specified and as directed20mm bore |
| 121 | S&F in repair gun metal globe or gate valves, (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed, for following bore complete all as specified and directed:- |
| 122 | 25 mm Bore |
| 123 | 20 mm Bore |
| 124 | S&F in repairs 15mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure with crutch or butterfly handleor concealed screwed both ends for iron pipe or for unions complete all as specified and directed.Note for all CP item :- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. |
| 125 | S&F in repair chromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed. |
| 126 | S&F in repair 15 mm bore bib taps, chromium plated, fancy type, long body, cast copper alloy with crutchor butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed . |
| 127 | S&F in repairs 15 mm borepillar taps, cast copperalloy, with capstan heads, chromium plated , Fancy type screwed down for pipe,high pressure , with or without lettered \" \"HOT\" or \"COLD\" with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed. |
| 128 | S&F in repairs shower rose 125 mm size chromium plated with or without swivel joints, any size, including fixing to15mm GI pipe or union complete all as specified and directed. |
| 129 | S&F in repair Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.complete all as specified and directed. |
| 130 | S&F PVC connection 15 mm size with PTMT nut of 600 mmlength complete all as specified and directed600mm |
| 131 | S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc. |
| 132 | S&F for Grating ,cockroch proof, round 125 mm diachromoum plated complete all as specified and directed. |
| 133 | S&F in repair 5mm thick bevelled edge best quality looking mirror of size 600x450 mm with 30 mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 6 mm thick AC bldg board, complete all as specified and directed. |
| 134 | S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approvrd by GE/AGE(I) complete all as specified & directed. |
| 135 | S&F in repair vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed. |
| 136 | S&F32 mm bore of pipe low density polythene pipe (LDPE) of pressurerating 6 Kgf / sqcm and fixed as waste pipe complete all as specified and as directed. |
| 137 | S&F in repair stainless steel sink with draining board, made out of 0.80 mm thick sheet for kitchen or laboratory with plug, washers, waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mmx 330mmx160mm complete all as specified and directed. |
| 138 | S&F in repair stainless steel kitchen plate rack0.80mm thick sheet of over all size 26\" x 31\" x 10\" fixed with steel screws and steel rawal plugscomplete all as specified and directed. |
| 139 | S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight per sqm not exc 4kg complete all as specified and as directed. |
| 140 | S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 141 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 142 | Excavating in trenches n\"exc 1.5 m width and n\"exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n\"exc 10 sqm on plan and n\"exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 143 | Demolition of cement concrete (un-reinforced)of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 144 | M&L concrete bed to pipes in PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for following bore sewer pipe line complete all as specified and directed :- |
| 145 | 150mm bore |
| 146 | M&L for salt glazed stone ware (SGSW) pipe, grade A, ISI marked, laid in trenches and jointed in CM (1:1) for following bore of pipe complete all as specified and directed :- |
| 147 | 150mm bore |
| 148 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. |
| 149 | Removing excavated material exc 1.5Km but n.exc 5.0 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 150 | Removing excavated materialn.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 151 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required (100/150 mm) complete all as specified and directed. |
| 152 | M&L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requriedandmakinggooddistrubedsurfacestomatchwithexistingfiniheswithandincludinginCM(1:4)mixedwithWPC/PCC(1:3:6)typeB0/BkworkinCM (1:4)asrequiredatsiteandas directed. |
| 153 | S&F heavy duty, stainless steel, ball bearing telescopic channel of 20-22 inch complete all as specified and directed. |
| 154 | S&F auto closing hinges 35 mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet & ward robe shutters complete all as specified and directed. |
| 155 | M&L for writing letters or figures (Block, Roman, Italic or Indian) not exc 30cm high complete all as specified and as directed. |
| 156 | M&L for cutting holes into or through brick walls built in cement mortar and making good in cement mortar (1:3) or PCC (1:2:4) type B1 to match with existing surfaceof following superficial area complete all as specified and as directed :- |
| 157 | Superficial area not exc 150 sqcm |
| 158 | M&L for cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed. |
| 159 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 160 | M&L for rubber moulded coloured glossy finish chequered cement concrete tiles, ISI Marked, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 20 mm thick screed bed in cement mortar (1:4) for following size of tile complete all as specified and as directed:- |
| 161 | 30cm x 30cm x 25mm thick |
| 162 | Dismantling and taking down old unserviceablepoint wiring of any type (light, fan, socket, power etc) complete with fitting such as switches, sockets, ceiling roses, pendants, lamp holders, light fitting etc including CI/ pressed steel terminals, switch box and making good the disturbed surface of wall/ floor etc to match with the existing surfaces of wall/ floor complete all as specified and directed.Note :- (i) If the contractor fail to make good the disturbed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute, the decision of Accepting Officer will be final and binding.(ii) Old fittings/ fixtures / accessories like switches, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. (iii) Only old unserviceable items will be considered in credit Sch. |
| 163 | Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. |
| 164 | Dismantling and taking down old damaged existing DB’s of any type and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc.complete all as specified and directed. |
| 165 | Taking down old unserviceable wooden meter boxof any size & any type from wall by disconnecting all electrical connections complete all as specified & directed. |
| 166 | Taking down energy meter from wooden/steel meter box carefully and deposit to MES store yard complete all as specified & directed. |
| 167 | M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit \"medium grade\" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box suitable for modular fixture with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii)If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding. |
| 168 | One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch. |
| 169 | One 5 pin socket out let 5/6 Amp on independent board. |
| 170 | One 5 pin socket out let 5/6 Amp on same board. |
| 171 | One light point controlled by two way 5 Amp switch. |
| 172 | Descrition same all as per item No 141 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed. |
| 173 | S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. |
| 174 | S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. |
| 175 | S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specifiedand directed. |
| 176 | S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specifiedand directed. |
| 177 | S&F modular switch piano, 1module, flush type button 5/6 Amp single pole two way conforming to IS: 3854 and ISI marked complete all as specified and directed. |
| 178 | S&F modular switch bell push button type, 1module,6 Amp single pole complete all as specified and as directed. |
| 179 | S&F modular fan regulator electronic, 2module, stepped type, suitable for ceiling fans of any capacity, pre-wired 120/ 280 volts AC 50Hz supply 100Watt complete all as specified anddirected. |
| 180 | S&F bell AC 230V single pole multi music type complete all as specified and as directed. |
| 181 | S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed. |
| 182 | S&F surface mounted LED luminiare 20 watt 4 feet with all accessoried having polycarbonate extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circut protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen perwatt, Inverter LED batten with square profile, inbuilt Lithium Ion battery with charging time 8-10 hours and back up time up to 4 hours, 6500 K internally pre-wired through flexible wire connection with ceiling rose complete all as specified and directed.Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period. |
| 183 | S&F angle Lamp holder (with metal ring), insulated body, of PVC/ Polycorbonate with back plate (ISI Marked) suitable for batten fitting complete all as specified and as directed. |
| 184 | S&F LED building security light 1 x 24W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 Sqmm, 3 core, PVC insulated copperconductor cable 1100 Volt grade complete all as specified and as directed. |
| 185 | S&F connecting & testing distribution board of sheet metal enclosures single door, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps ratinghaving following capacity complete all as specifiedanddirected:- |
| 186 | DB SPN, 8 way |
| 187 | S&F connecting & testing MCB, 230V/ 415Vwith rupturing capacity 10 KA of following capacity complete all as specified and directed:- |
| 188 | MCB 10 to 32 Amp, SPN, \"B\" series/ curve, |
| 189 | MCB 6 to 32Amp, SP, \"B\" series/ curve, |
| 190 | S&F industrial type socket & plug top of 20Amp, 230V, Single Pole and neutral,sheet metal enclosure with and including MCB of ‘C’ series 10KA of following capacity complete all as directed and specified :- |
| 191 | Single pole, 20 Amps, 240 volt. |
| 192 | S&F air fresh fan AC single phase 230/240 Volt of size 300mm sweep, metallic body powder coated painted finish, power consumption 50W, air displacement 1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wall complete all as specified and directed. |
| 193 | S & F ventilation air fan AC single phase 230/240 Volt of size 250 mm sweep,non-metallic high quality engineering plastic, air delivery 680 cmm Power consumption- 36 W, RPM-1200 complete with louversand two years warranty including making hole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed. |
| 194 | Dismantling existing Geyser from site and keeping in safe custody for refixing in thesame opening including new PVC connection of suitable size and length, fastners complete all as specified and directed. |
| 195 | S&F sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected withmain earth dolly including cuttingchasesand making good disturbed portion complete all as specified and directed. Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. |
| 196 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. |
| 197 | Supply and laying cable protection bricks, common burnt clay sub class \"B\" designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. |
| 198 | M&L for road cutting for laying cable and through GI Pipe of suitable size making good with PCC 1:3:6 type C-2(using 40 mm graded stone aggregate) of 150mm X 100mm inrespect ofwidth and thickness complete all as directedby Enger -in- charge.Note: GI pipe should be deemed to be included in the quoted rate. |
| 199 | S&F in repair GI tubing light grade 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under load etc for cable protection complete all as specified and directed. |
| 200 | M&L for fixing or passing through pipe, laid in trenches, fixed on wall,LT panel board,XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 4 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools,heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirementall as specified and directed. by Engr-in-charge.Note:(i)GI tubing requiredshall be measured and paid separately under relevant item.(iii) Heat shrink sleeve of 25mm long on HS joint for colour indicationshall deemed to be included on the quoted rate. |
| 201 | Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted,of size not less than 900x900x250mm and maximum size suitable for fixing under metioned MCCBs, Pre paid meters, Multifunction meters 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the followingand size of panel suitable to fixing all below materials with required space as per IE rules:- (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings.ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three)INCOMING SUPPLY:-i) MCCB 40 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No. |
| 202 | OUTGOING SUPPLY:-i) MCB SPN 25-32 Amps,240Volts, 50Hz, rupturing capacity 10 KA = 4 Nos, Make of MCB-L&T/Siemen /Legrend/Schneider.(ii) MCB SP 6-32Amps 230 volts, 50 Hz, rupturing capaicty 10KA=2 Nos.Make of MCB-L&T/Siemen /Legrend/Schneider.iii)Space for SmartPre paid Electric Energy metersinglePhase AC 230 V, 10-32 Amps -04 Nos & Smart Pre paid energy meter 5-10 Amps -01 Noiv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos. Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible .Notes:-1. The panel manufacturer should have following certification:-i)CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests)ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore desing the panel . 4. Panel board should be in accordance with IEC 61439-1-2 and maintaing space between MCCBs, MCBs, meters as per IE rules.5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing. |
| 203 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. |
| 204 | Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail