Construction Of Community Hall At Ward No.11 Kk Nagar (Harisana Colony) In Periyanegamam Town Panchayat. , Earth Work Excavation For Foundation In All Soils And Sub Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting But Inclusive Of Shoring, Strutting And Baling Out Water Wherver Necessary As Per Ss 20 B Etc., Complete Complying With Standard Specifications. , Plain Cement Concrete 1:4:8 (One Cement,Four Sand And Eight Aggregate) Mix Using 40Mm Gauge Hand Broken Hard Granite Stone Jelly For Foundation Including Dewatering If Found Necessary And Laid In Layers Of Not More Than 15Cm Well Rammed Etc., Complete Complying With Standard Specifications. , Supplying And Erecting Centering For Sides And Soffits Including Supports And Strutting Upto 3.29 M High For Plane Surfaces Such As Rcc Slabs, Rectanular Beams, Lintels And Stair Case Waist Slabs Conopy Etc., In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90Cm X 60Cm And Bg 10 Stiffened With Welded Mild Steel Angles Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Country Wood Joists Of Size 10Cm X 6.50Cm Spaced At About 90Cm Centre To Centre And Supported By Casuarian Props Of 10Cm To 13Cm Dia Spaced At 75Cm Centre To Centre Etc., Complete And As Directed By Departmental Engineers.A. Plinth Beams , B. Beams And Slab Ground Floor , C. Columns , Supplying, Fabricating And Placing In Position Mild Steel/Ribbed For Steel Roads For All Rcc Works Including Cost Of Steel And Binding Wire Also In All Floors, Complete Complying With Standard Specifications. , Providing And Laying In Position Standardised Concrete Mix M-20 Grade In Accordance With Is 456 - 2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Contenet Of 325Kg/ Cum And Maximum Water Cement Ratio Of 0.55 Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is 9103 To Accelerate, Related Setting Of Concrete, Improve Workability Without Imparing Strength And Durability With About (5.0Cum), 7730Kg Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cum), 5156Kg Of 10 - 12Mm Machine Crushed Stone Jelly And With About (4.79Cum) 7670 Kg Of Crushed Stone Sand (M- Sand), But Excluding Cost Of Reinforcement Grill And Fabricating Charges Centering And Shuttering But Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc And Providing Fixtures Like Fan Clamps In The Rcc Floor / Roof Slabs Wherever Necessary Without Claiming Extra Cost Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers - Up To Basement , G.F , F.F , S.F , Brick Work In Cement Mortor 1:5 Mix (One Cement, Five Sand ) Using New Best Countrybricks Of Size 8 ¾”X 4 ¼”X 2 ¾”From Approved Quarry Including Cost And Conveyance Of All Materials To Site. Loading And Unloading Charges And Labour Charges For Mixing, Laying And Curing Etc. Complete. Complying With Std. Specifications.A.For Foundation And Basement , B. For Ground Floor , C.First Floor , S.F , Collection Supply And Filling Ofwell Gravel From Approved Quarry Including Cost And Conveyance Of All Materials To Site, Loading And Unloading Charges And Slacking The Same To Site To Departmental Gauge And Filling To Required Depth, Well Rammed Etc., Complete As Per Standard Specification , Special Ceiling Plastering And Finishing All The Rcc Exposed Surfaces Such As Rcc Slabs, Sunshades, Conopies, Staircase Steps , Etc., With Cement Mortar 1:3 (One Cement Three Sand) Mix To 10Mm Thick And Including Hacking The Surfaces And Providing Necessary Cement Mortar Nosing Beading As Per Size, Specification Wherever Necessary Using The Same Mix As Directed By The Departmental Officers Etc., Complete Complying With Standard Specifications. , Plasteringwith Cement Mortar 1:5 (One Cement Three Sand) Mix To 12Mm Thick And Including Hacking The Surfaces And Providing Necessary Cement Mortar Nosing Beading As Per Size, Specification Wherever Necessary Using The Same Mix As Directed By The Departmental Officers Etc., Complete Complying With Standard Specifications. , Dadoing The Walls With Colour Glazed Square Tiles Size 15Cm X15cm X8mm Of Best Approved Quality In Cement Mortar 1:2 ( One Cement And Two Sand ) Mix And Pointing With The Same Colour Cement Neatly To Full Depth Of Tiles In All Floors As Directed By The Departmental Officer Etc., Complete Complying With Standard Specifications. , Paving The Floor With Vitirified Tiles Size 600 X 600 X 8Mm Of Approved Quality And Colour Of Any Sizein All Floors Over 20Mm Thick Cment Mortar1:3 (One Cement And Three Sand) Mix Base Above The Existing Bed Concrete And Pointing With Same Colour Cement Added With Colouring Pigmentsetc., Complete Complying With Standard Specification. , Weathering Course Concrete With Broken Brick Jelly Of 20 Mm Gauge In Pure Slacked Lime ( No Sand To Be Added) Over Roof Slab The Proportion Of Brick Jelly To Lime Being 32:12.5 By Volume And Laid Over In A Single Layer And Consolidated Require Designed And Finished Thickness By Beating The Concrete With Wooden Beaters Of Approved Pattern , Keeping The Surface Constantly With Springing Lime Jiggery Water Asper Standard Specification And As Directed By The Departmental Officers Complete As Per Standard Specification. , Finishing With Top Of Roof With One Course Of Machine Pressed Tiles Of Size 20Cmx20cmx2cm Of Approved Quality Laid In Cement Mortar 1:3 (One Part Ofcement And Three Part Of Sand) 12Mm Thick Mixed With Water Proofing Compound Conforming To Iss By 2% Weight Of Cement Used And The Joint Pointed Neatly To Full Depth Of Tiles With Same Water Proofing Compound Mixed With Cement Motar ,Red Oxide, Etccomplete As Per Standard Specification. , Supplying And Fixing In Position Best White Glazed Earthenware Indian Water Closet Of Approved Quality Of Size 580Mm X 440Mm. With P Or S Trap And Embedding The Closet With Trap To Shape In Position With 40Mm Brick Jelly Concrete 1:2:5( One Lime ,Two Sand And Five Brick Jelly) And Finishing The Top To The Required Slope And Including Giving Connection To The C.I. Soil Stracks By Dismantling The Masonry Floor Or Rcc Works And Redoing The Same To The Original Condition Without Anyleakage Etc., Complete As Directed By The Departmental Officers, ( The Water Closet Should Be Got Approved By The Department Officers Before Use On Work). , Supply And Fixing Of Pvc Panelled Door With Frame Shutters Hollow Type 200Mm X 20Mm Panels With 1Mm Wall Thickness For Panels And Styles And Rails Of Suitable Size With 2Mm Wall Thickness Suitabley Reinforced Using Ms Angle/ Flat Including Cost Of Necessary Aluminium Hinges And Other Furniture Fittings With Frame Etc.,Complete., , Supplying And Fixing In Position Of Upvc Windowsin Positionincluding Labour Charges For Fixing Furniture Fittingsfor Windowswith Standard Drawings , Etc., Complete Complying With Standard Specifications. , Louvered Ventilator Supplying Fabricating And Fixing In Position Of Aluminium Anodized Natural Colour Matt Finished Louvered Ventilator Using Outer Frame Ofsize 62 X 38 X 2Mm @1.17Kg/M And The Louvers With Moving Arrangements Will Be Made With Aluminium Channel Of Size 60 X 30 X 4 Mm @ 1.27Kg/M With Necessary Glass Panels For Louvers 4Mm Thick Aluminium Clips , Including All Materials,Labour,Power Consumption Charges Required For Fabrication If Necessary Chipping Dismantling Making Necessary Holes In Rcc Coloumns, Beams Or Masonry Wherever Necessary With Power Drill To The Extent Required And Made Good To The Original Conditions After Fixing As Drected By The Departmental Officers The Aluminium Surfaces Should Be Anodised With Matt Finish Under Electrically Controlled Conditionin Accordance Withisspecification 1868/1962 Of Anodic Thickness Of Not Less Than 15 Microns (Fifteen) Complete.All The Materials Should Be Got Approved By The Engineer Incharge Before Fixing As Directed . , Supplying And Fixing In Position Of M.S Grills Using For Windows And Ventilators In Positionincluding Labour Charges For Fixing Furniture Fittingsfor Windows & Ventilatorswith Standard Drawings , Etc., Complete Complying With Standard Specifications. , Provding And Finishing Over Sloppedrcc Roof Or Sunshade With One Course Of Ornamental Tiles Of Size 23 X 15 X1.2Cm For Front Elevation Laid With C.M 1:3(One Cement Three Sand 20Mm Thick And Pointed With Same Mortar Mixed With Red Oxide And Wpc At The Rate Of 2% By Weight Of Cement Including Neatly Finishing Etc., Complete As Per Standard Specification (The Colour And Make Of The Tiles Should Be Approved Before Execution From The Deparmental Officers) , Wring With 2 X 1.5 Sq.Mm (22/0.3) Pvc Insulatedunsheathed Sc Cu. Conductor Of 1100V Grade In Suitable Pvc Rigid Pipe Concealed In Wall And Ceiling With Pvc Accessories With Tw Switch Box And 5A F.T. Switch In Flush Wallwith 3Mm Tk Hylum Sheet Coverfor Makinggood Of Theconcealed Portion With Suitable Colour For Pvc Concealed Light Point.(Sd.No:24) , Supply And Fixing Of 5A / 15A 3 Pin Combined Flush Type Wall Socket With 15A Flush Type Switch On Suitable Tw Box.Plug Point( Sd 136 ) , Wiring With 2 X 4 Sq.Mm (56/0.3)Pvc Insulated Sc Unsheathed Cu. Conductor Cable Of 1100V Grade In Suitable Pvc Rigid Pipe Concealed Inwall And Ceiling With Pvc Assosaries,In Flushwith Wall, With 150Mm X 100Mm X 113Mmtw Switch Box With 3Mm Tk Hylem Sheet For 15 A 3 Pin Non Interlocking Cs Plug With Continious Earth Wire Conection Of 14 Swg Tc Wire, And Making Good Of The Concealed Portion,With Suitable Colour For Concealed Power Plug Point ( S.D.No:39 ) , Supply And Run Of 2 Of 1.5 Sq.Mm (22/0.3) Pvc Insulated Sc Unsheathed Cu. Conductor Of 1100V Grade Inrigid Pipe Concealed In Wall And Ceiling With Continuous Earth Wire Connection Of 14Swg Tc Wire And Making Good Of The Concealed Portion With Suitable Colour. ( S.D. 54 ) , Supply And Run Of 4 X 6 Sqmm (56/0.3) Pvc Insulated Sc Unsheathed Cu,Conductor Of 1100V Grade In 32Mm Dia Gi Pipe ( Class B) Suitably Bent At Both Ends With Necessary Angle Iron Up Right And End Supports For Mains. (S.D.73) , Supply And Run Of 2 X 4 Sqmm (56/0.3) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100Von 7/20 Gi Bearer Wire For Service Connection Mains. (S.D.65) , Supply And Fixing Of Single Box Type 440W Flu Fittiing Complete With Copper Choke And Condensor With Tw Round Blocks On Wall Or Ceiling With Pvc Unshealthed Copper Leads From Terminals To The Fitting. (S.D.88) , Supply And Fixing Of Wt Bulk Head Fitting With Guard (Phillips/Bajaj/Crompton/K.Life) Suitable Forlamp With 11 W Cfl Bulb.(Sd .83) , Supply And Fixing Of 1400 Mm (56) /Sweep Ac Ceiling Fan Complete With Stepped 300W Regulator, With The Existing Down Rod On The Existing Clamps.(Sd 108) , Supply And Fixing Of 16A D Pswitch With Metal Clad Of 500V With Fuse And Neutral (Sidehandle) On Suitable Twboxpwdearthingsd 141 , Earthing As Perpwdstandard With An Earth Electrode Of2metreclass B Gipipe Ofdia Not Less Than32mmcompletewithnecessarymasonry Work Sd 212 , Supply And Fixing Of Horizontal Type 4Way Triplepole Neutral Mcb Distribution Board In Sheet Steel Enclosure Doubledoor (Metal) With 40A 4Pole Mcb Isolateras Incoming And 12Nos.6A To 32Aspmcb As Out Going In Flush With Wall And Making Good Of The Concealed Portion With Earth Connection.The Mcb Db And Mcb S Should Be With The Isi Mark (Like Standard Make) Sd 179 , Painting Iron Works For Doors, Windows And Ventilators, Iron Bars, Weldmesh, Wiremesh Screen, Steel Bars , Flats And Other Similar Works Etc., With Two Coats Of Approved First Quality Of Synthetic Enamel Paint Over The Existing Red Oxide Primer In All Floors It Inclusive Of Cost Of Materials And Labour, Brushes And Scaffolding Etc., Complete Complying With Standard Specifications. , Emulsion Paint Two Coats Using Best Approved Colour And Quality Cement Paint In All Floors Including Cost Of Lime And Other Materials, Brushes, Scafolding Charges Etc., Complete Complying With Standard Specifications And As Directed By Departmental Officers. , Supplying And Laying Rubberised Interlocking Paver Blockm40 Grade Providing And Laying Of83mmthick High Strength Type Conforming Is 15658-2006 Of Rubberized Interlocking Paver Lock In Size Of Minimum Compressive Strength Of 40N/Mm2 In Uniform Shape Of Approved Make To Be Laid In Flurring Bone Pattern With Sand Cushion Below The Uniform Shap Of Approvednon Skitting Surface In The Top And The Rate Including Levelling The Base Preparation Ofpavers As Sub Base, Sand Cushion 100Mm Thick Layingout Of Pavement Cut The Pieces To Fix The Edge Vibring The Pavers,Sweeping Tranporting Loading Unloading Of Laying Paver Block As Per Standard Specification,. , Supply And Delivery Of 2000 Litre Capacity H.D.P.E.Water Tank Approved Isi Quality Including Cost And Convenance Of All Materils To The Site Etc Complete As Per Standard Specification , Reinforced Cement Concrete 1:1½:3 Mix (One Part Cement, One And Half Part M.Sand And Three Part Of Aggregate)Using 20Mm Size Iss Hbg Metal Machine Crushed From Approved Quarry Including Cost And Conveyance Of All Materials To Site, Loading And Unloading Charges And Labour Charges For Mixing, Laying And Curing But Excluding Cost Of Reinforcement Etc.Complete With Std.Specifications. Tndss No: 30 V, Vi (S3), Vii-3. , All Figures Quoted Should Be Inclusive Of Gst Charge