| 1 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m. |
| 2 | All kinds of soil. |
| 3 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. |
| 4 | Beyond 30 cm girth up to and including 60 cm girth |
| 5 | Cutting all the branches (girth (30-60 cm) of trees like jackfruit,mango/teak lean over the building carefully by hanging down without any damages to the building/roofing sheets & stacking the firewood as directed by the engineer in charge. |
| 6 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 7 | Asbestos cement sheet |
| 8 | Providing asbestos cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 9 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 10 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 11 | Supplying MS Anchorbolts, bolts and nuts for mast all complete etc at site. |
| 12 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 13 | Hot finished welded type tubes. |
| 14 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 15 | Of area beyond 3 sq. metres (4.50x2.10 m) size |
| 16 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 17 | In cement mortar |
| 18 | Repairs to rolling shutter of size (3.0x3.0 m) including oiling/greesing bearings/guide channels/springs for easy opening etc..complete. |
| 19 | Taking out existing wooden door/winow shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 20 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 21 | 250x16 mm |
| 22 | Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 23 | Above plinth level upto floor V level. |
| 24 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 25 | 1:6 (1 cement: 6 fine sand) |
| 26 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 27 | 1:3 (1 cement: 3 fine sand) |
| 28 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 30 | Hot rolled deformed bars |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 32 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 33 | White washing with lime to give an even shade : |
| 34 | Old work (two or more coats) . |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 36 | One or more coats on old work. |
| 37 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 38 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 39 | Clearing & cleaning the terrace/wall/AC sheet roofing with pressurewash including the cost of scaffolding etc.complete |
| 40 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 41 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 42 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 43 | One coat. |
| 44 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 45 | 15 mm nominal bore |
| 46 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 47 | 15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms. |
| 48 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 49 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 50 | Providing and fixing PTMT bib cockof approved quality and colour. |
| 51 | 15 mm nominal bore, 122 mm long. Weighing not less than 99 gms. |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 53 | 20 mm nominal outer dia. Pipes. |
| 54 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 55 | For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 56 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 57 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 58 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 59 | Providing & fixing \"J\" handles (powder coated ) for Alu.windows. |