| 1 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified anddirected. |
| 2 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed. |
| 3 | Taking down roof trusses, coupled rafters or trussed beams of clear span above 4 mtrs and upto 8 mtrs complete all as specified anddirected. |
| 4 | Dismantling wrought cast iron or mild steel work of any description not otherwise provided , complete all as specified and directed. |
| 5 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified anddirected. |
| 6 | Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any posotion complete all as specified & directed. |
| 7 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed. |
| 8 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 9 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 10 | Demolition of reinforced cement contrete of any description in any position not otherwise specifically provided for complete all as specified & directed. |
| 11 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge. |
| 12 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed by the Engineer-in-Charge. |
| 13 | M&L for Providing reinforced cement concrete Type A-1 1:1 1/2:3 (using 20mm nominal size graded crushed stone aggregate)as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete including necessary form work all as specified and directed. |
| 14 | M&L forForm work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for rough finished flat surfaces of concrete Complete all as specified and as directed. |
| 15 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, Complete all as specified and as directed. |
| 16 | M & L for mild steel TMT bars 6 mm to 8 mm dia, in stirrups cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and as directed. |
| 17 | M&L for brick work with sub class old size \"B\" bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 18 | M & L for brick workwith subclass “B” Old size bricks, straight or curved on plan,exceeding 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 19 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfacesfinished even and smooth without using extra cement complete all as specified & directed. |
| 20 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement complete all as specified & directed. |
| 21 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 mm thick and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 22 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed. |
| 23 | Pressed steel frames (125 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. |
| 24 | M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in bed block, blocks for holdfasts,filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed. |
| 25 | S&Fmild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) complete all as specified and directed. |
| 26 | S&Frolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachmentconforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 27 | S & F Mild steelbolts with hexagonal or square heads at one end and screwed the other or screwed both ends each screwedend to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter exc 12 n.exc 20 complete all as specified and directed |
| 28 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified anddirected |
| 29 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified anddirected. |
| 30 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications complete all as specified anddirectedby Engineer – in - Charge. |
| 31 | M&L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructionsanddirected by Engineer – in - Charge. |
| 32 | S&F 30 mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats complete all as specified & directed. |
| 33 | S&F 35 mm thick, hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified & directed. |
| 34 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 35 | S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 36 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 37 | S&F 300mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 38 | M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 39 | S & F for aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified & directed. by Engineer – in - Charge. |
| 40 | S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified &directed. |
| 41 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 42 | M&L preparing oldwood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applyingone coat of synthetic enamel paint complete all as specified & directed. |
| 43 | M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded crushed stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete all as specified & directed. |
| 44 | M&L for PCC 40mm type B1 1:2:4 ( using 20mm graded crushed stone aggregates) in floors, finished even and smooth, using extra cement complete all as specified and directed. |
| 45 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0 kg of cement per sqm, complete all as specified and directed. |
| 46 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed. |
| 47 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick renderingin cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed. |
| 48 | S&F in repair harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 49 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 50 | M&L for Point wiring complete with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including concealed type rigid non-metallic PVC conduitof suitable size but not less than 20mm dia , with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc. and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified & directed for :-Note :- (i) Modular Plates & Covers and Modular Metal Boxes/PVC Boxes will measured and paid separately under relavant items.(ii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.(iii) The wiring shall be done strietly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.(a) One light /Fan /Ex Fan point controlled by one, one way switch(b) One socket outlet 3 or 5 Pin, 6 Amp on same board.(c) One socket outlet 3 or 5 Pin, 6 Amp on independent board |
| 51 | All as per above Ser item No 50but with 2.5 sqmm copper cable in and concealed type rigid non-metallic PVC conduit complete all as specified and as directed for socket outlet 3 or 6 pin 15 Amps. |
| 52 | S&F in repair modular switch 6 Amp one way 1 module 230 V AC complete all as specified and directed. |
| 53 | S&F in repairmodular switch 16 Amp one way 1 module230 V AC complete all as specified and directed. |
| 54 | S&F in repairmodular socket outlet 6Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed. |
| 55 | S&F in repair modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed. |
| 56 | S&F in repair modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed. |
| 57 | S&F in repair3 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 58 | S&Fin repair 4 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 59 | S&F in repair 6 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 60 | S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 61 | S&Fin repair ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI markedcomplete all as specified and as directed. |
| 62 | S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver,including fitting fixed on wall/ceiling and connecting up complete with 3core flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 63 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from item no 1.00 above. |
| 64 | S&F LED Tube lights fitting 1 x 9/10 Watt, 2 feet , 220V AC decorative box type with driver, including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed. |
| 65 | S&F LED Tube lights fitting 1 x 35 Watt, with new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housingwith high power LED as lighting source and lens emoedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection complete all as specified and directed |
| 66 | Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard by the contactor,all as specified and directed. |
| 67 | Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |
| 68 | S&F ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods andconnected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor and connection complete all as specified and directed. |
| 69 | M&L for providing concealed submain wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing throughPVC Conduit complete as per direction including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutterand making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 6.00 Sqmm multi stranded copper cableand one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit. |
| 70 | S&FPrewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 420 Volts 4 way Triple pole and neutral link, incl taking down old u/s any type, complete all as specified and as directed. |
| 71 | S&F MCB triple pole and neutral (TP&N) 63 Amp 415 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 72 | S&FPrewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way single pole and neutral link, incl taking down old u/s any type, complete all as specified and as directed. |
| 73 | S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 74 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |
| 75 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying under ground cables/ pipes etc and getting out any type soil all as dircted |
| 76 | Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm ,complete all as specified and as directed . |
| 77 | Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point,complete all as specified and as directed . |
| 78 | Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directedby Engr-in-Charge at site,complete all as specified and as directed .Note : - Only punned thickness shall be measured for payment purpose |
| 79 | Supply and laying burnt brick sub class ‘B’ of standard size laid in trenches as protection to cablescomplete all as specified and as directed . |
| 80 | Boring of holes under road, pavement, hard standing by trenchless technologytechnique for 40-80 mm dia pipecomplete all as specified and as directed . |
| 81 | M&L for light grade galvanized pipe ISI markedlaid in trenches, under road or fixing on wall/pole/ crossing nallah etc for cable protection of bore40 mm complete all as specified and as directed . |
| 82 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power UG cables (heavy duty) 1100 Volts grade with stranded aluminium conductor confirming to relevant IS specifcations of size 16 sq mm 2 core including taking down old unsv service wire of any size complete all as specified & directed. |
| 83 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed. |