Tender For Provn Of Ration Store At Dsc Mess And Allied Work At Af Stn Manauri.; 1 Excavating in trenches, in soft / losse soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting complete all as specified and directed. 2 Returning, filling in, including spreading, levelling, watering and well ramming in layers,soilnot exc 25 cm.complete all as specified and directed. 3 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 4 M&L for PCC1:4:8 type D-2 using 40mm graded stone aggregate , as in foundation,filling & mass concrete etc complete all as specified and directed. 5 Use and waste of formwork to sides of concrete foundations, footings, bases of columns,plinth beams and similar work; vertical or to batter finished rough surface of concrete complete all as specified and directed. 6 Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. 7 Use and waste ofform work to chajjas rough surface of concretecomplete all as specified and directed. 8 Use and waste ofform work of sides of pillars, posts, struts, piers, columns etcsquare or rectangular or polygonal finished rough surface of concrete complete all as specified and directed. 9 Use and waste of formwork to soffits of suspended slabs such as roof slabs and similar work; not exceeding 200m thick flat finished rough surfaces of concrete complete all as specified and directed. 10 Use and waste of form work to side of lintel complete all as specified and directed. 11 Use and waste of form work to the edge of concrete flat exc 10 cm but n.exc 20 cm wide complete all as specified and directed. 12 S & F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 13 S & F TMT bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for stirrups,spacers & binders binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 14 M&L for RCC M-25 using 20 mm graded stone aggregate as in footings, plinth beam, bases for columns and mass concrete complete all as specified and directed. 15 M&L for RCC M-25using 20 mm graded stone aggregate for roof slabs, lintels and slabs supported on walls and similar work complete all as specified and directed. 16 M&L for RCCM-25using 20 mm graded stone aggregate for chajjas and similar work complete all as specified and directed. 17 M & L RCC M25 using 20 mm graded stone aggregate as in roof beams and similar work complete all as specified and directed. 18 M & L RCC M 25 using 20 mm graded stone aggregate as in Columns, pillars and similar works complete all as specified and directed. 19 M&L providing, cement concrete type B1 using 20mm aggregate in lintels upto 1.5m clear span, cills, steps;eismic and other similar bands, plinth courses, string courses, lacingourses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. 20 M&L brick work with sub class B bricks, straight or curved on plan exc. 6 mtr mean radius built in CM(1:6) complete all as specified and directed. 21 M&L for 15 mm rendering in cm 1:6 on fair faces of brick work finished even and fair complete all as specified and directed. 22 M & L for preparation of new surfacesand applying 2 coats of dry distemper over a coat of primer complete all as specified and directed. 23 M&L Rendering 15mm thick plaster in CM 1:4 onsurface other than fair faces of brickwork finished even & smooth complete all as specified and directed. 24 M & L for preparation of new surface of wall including cornices and apply two coat of cement based paint over a coat of primer etc complete all as specified and directed. 25 S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay,with glazing bars, dovetailed or welded complete all as specified and directed. 26 M&L Rendering but 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed. 27 M&L Preparing New surfaces & applying three coat of a white wash on ceiling complete all as specified and directed. 28 M&L Priming the surface with one coat of cold applied bituminous primer @ 0.25 ltr /sqm conforming to IS: 3488 & apply a layer of APP based polymeric membrane 3 mm thick (min) weighing 3 Kg / Sqm reinforced with polyester non woven febric (weighing not less than 150 gms / Sqm) applied by torch application having side over lap 75 mm and at the end 100 mm including sealing the joints and appication of bituminous aluminium paint.Note : Membrane shall be taken to a height of min 60 cm and inserted in a groove on parapet wall where required.The work shall be deemed to include in the item rate complete all as specified and directed. 29 S & F Pressed steel frames for door frame of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete, as specifiedcomplete all as specified and directed. 30 M & L PCC 1:3:6 type C1 using 12.5 mm graded stone aggregate for fiiling of hollow section complete all as specified and directed. 31 M & L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in floor and forfixing of hold fastetc complete all as specified and directed. 32 S & F 35 mm thick 2nd class hard wood glazed and skelton door shutter, open rebated and prepared to receive glass, gauze, etc(without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads forscuring glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I,ection 8, clause 8.24 (a); supplied and fitted to chowkatscomplete all as specified and directed. 33 S & F30mm thick flush door shutters solid core construction, with block board core and plywood face panels, commercial type on both sidefixedto chowkhat complete all as specified and directed. 34 S&F Butt hinges 100mm long medium weight, colled rolled mild steel complete all as specified and directed. 35 S&F Aluminium, anodised, barrel tower bolts of 200 mm long and 10mm dia stove enamelled black with bright bolt fixed complete all as specified and directed. 36 S&F extruded aluminium alloy handles 125mm size fabricated type anodized ISI markedcomplete all as specified and directed. 37 M&L two Coats of synthetic enamel paint over a coat of pink primer surfaces of any description, over 10cm in width or girth,not otherwise described in new wooden surfacescomplete all as specified and directed. 38 S&F sliding bolt 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. 39 M&L 75mm thick PCC (1:2;4) type B-2 using 40mm graded coarse aggt in plingth protection laid in alternate bays and joint filled with bituminious mastic complete all as specified and directed. 40 M&Lbroken stone hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete as specified and directed. 41 Supply only liquid water proofing compound. 42 Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. 43 Sand filling under floors or infoundations spreading and levelling in layers n exc. 25cm thick including watering and consolidation complete all as specified and directed. 44 M&Lfor 75 mm th PCC 1:4:8 type D-2 using 40 mm graded stone agg as in under floorSub base.complete all as specified and directed. 45 M&Lfor 25 mm thick PCC 1:2:4 type B-1 as in under floorSub base.complete all as specified and directed. 46 M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth with extra cement complete all as specified and directed by Engineer-in-Charge. 47 M&L prepration of steel surfaces and applying two coats synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed. 48 M&L treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by the Engineer-in-Charge. 49 Treating the backfill in contact with foundation at the rate of 7.5 litres ofeulsion per square metre of vertical surface (Area of the sub structure incontact with backfill to be measured complete all as specified and directed by the Engineer-in-Charge. 50 Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface ®complete all as specified and directed. 51 Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface areacomplete all as specified and directed. 52 S& Fgalvanized mild steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or glavanized wire stables, beads or in steel windowscomplete all as specified and directed. 53 Supply and fixing kessal grease separators NS2 under ground Art No.93001/80 B,HSN code -84212190 ,including excavation in any type of soil, foundation in PCC 1:3:6, including connection to existing sewer line/septic tank/soakage well as manufacturer instructions ,also surface making good to finih and site clearance also complete all as specified all as speciied by Engr-in-charge.Note :-Drawings and Specificationsfor kessal grease separators NS1 are held at the Office of AGE (I) AF Manauri.These documents are not enclosed with the tender documents and can be seen in the office of the AGE [I] Manauri during working hours. 54 M&L for PCC1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to floor etc complete all as specified and directed by Engr-in-charge. 55 M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate , as in copping etc complete all as specified and directed by Engr-in-charge. 56 M&L brick work with sub class B bricks(old size bricks) straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:4 and external face of brick work pointed flush in the same mortar as the work proceeds, complete as specified and directed. 57 M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concretesurfaces finished even and fair without using extra cement complete all as specified and as directed.Note :- Water proofing compound measured separately. 58 M&Lfor 75 mm thick hardcore of broken stone aggt. of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 59 M&L for providing75 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor, finished even and smooth without using extra cement complete all as specified and directed . 60 S & F in repairs 1.25mm thick MS, plain black sheet in steel gates, covering to door and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints all as required complete all as specified and as directed. 61 S & F Rolled Mild Steel Framed work as in doors or Gates of angle or other section confirming to Fe 410 -W (Gde- E- 250) quality- A with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed. 62 M&L in applying two coats of synthetic enamel paints over a coat of red oxideprimer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed by the Engineer-in-Charge. 63 S&F 110/100mm PVC (SWR) type B pipes single socketed in any length with mild steel clamps laid in trenches or in floor & walls rubber ring joints fixed to walls complete all as specified and directed. 64 S&F 110/100mm PVC (SWR)type B bends any radius complete all as specified and directed. 65 Material and labour for point wiring includingconcealed in surface of structure/ truss etc rigid non-metallic PVC conduit pipe medium grade, ISI marked heavy duty in size 20 MM diawith 1.5 Sqmm FRLS insulated unsheathed, multi stranded copper conductor cable, single core 1100 volt grade with flush cast iron/ pressed steel terminal boxes of suitable size for fixingsuch as switches, sockets and fan regulators etc and fixing with brass screws/cup washer and including FRLS insulated & unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 Sqmm as continous earth wire complete including making good the disturbed surfaces for the following complete all as specified and directed:-Note:-Quoted rate shall be included cost of cheasesing,cutting, plastering and colouring etc to surface of wall / beam/ roof etc as site requiredmatchingwith existed surface and blank plate to be cover up to extra gap in mountingboard in given module /make / model etc. 66 Allas per item No 65 One light point/Fancontrolled by one way indepdentswitch complete all as specified and directed. 67 Allas per item No 65here in before one 3 pin 5 Amps socket out let point on independent board controlled by one switchcomplete all as specified and directed. 68 All as per above item No65 here in before point wiring for 15 Amps socket using 2.5 Sqmm copper cable for phase and neutrl and 2.5 Sqmm as earth wire complete all as specified and directed. 69 Supply and fixing for circuit/submain wiring alongwith earthwire with the 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FRLSH is PVC insulated copper conductor, single core cableconcealed in surface of structure/ truss etc rigid non-metallic PVC conduit pipe medium grade, ISI marked heavy duty in size 20 MM diaas required including making good the disturbed surfaces for the following:-- Note:-Quoted rate shall be included cost of cheasesing,cutting, plastering and colouring etc to surface of wall / beam/ roof etc as site requiredmatchingwith existed surface and blank plate to be cover up to extra gap in mountingboard in given module /make / model etc complete all as specified and directed. 70 Supply and fixing modular switch , one way 6 Amps 1 module complete all as specified and directed. 71 Supply and fixing modular switch, one way 16 Amps 1 module complete all as specified and directed. 72 Supply and fixingmodular socket 6 A, 2/3 pin combined 2 module complete all as specified and directed. 73 Supply and fixingmodular socket 16 A, 3/5 pin combined 2 modulecomplete all as specified and directed. 74 Supply and fixing ceiling rose surface type 65 MM x 50 MM, 2 to 3 terminal complete all as specified and directed. 75 Supply and fixing in replacement white cover plate with frame 3 module complete all as specified and directed. 76 Supply and fixing in replacementwhite cover plate with frame 2modulecomplete all as specified and directed. 77 Supply and fixing in replacement LEDlight fitting with frame, driver etc in 25 W4 feet long white colour mounting on tow Nos of PVC round/ square block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unsv old fittingscomplete all as specified and directed.