}

Tender For Construction Of Vprc Building At Rayampettai Panchayat Thiruvaiyaru Block Under Rrgsa - 2025-2026, Thanjavur-Tamil Nadu

Rural Development And Panchayats Department has published Tender For Construction Of Vprc Building At Rayampettai Panchayat Thiruvaiyaru Block Under Rrgsa - 2025-2026. Submission Date for this Tender is 01-08-2025. Building Work Tenders in Thanjavur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50368109
Tender For Construction Of Vprc Building At Rayampettai Panchayat Thiruvaiyaru Block Under Rrgsa - 2025-2026
Tender
Indian
Tamil Nadu
Thanjavur
01-08-2025

Tender Details

Construction Of Vprc Building At Rayampettai Panchayat Thiruvaiyaru Block Under Rrgsa - 2025-2026 , Rayampettai Panchayat . , Construction Of Common Service Centre In Mariyadass Nagar At Rayampettai Panchayat. , Earthwork Excavation For Foundation (For Narrow Excavation) To Full Depth As Per Designed In All Soils And Sub Soils Except Soft Disintegrated Rock Not Requiring Blasting And Hard Rock Requiring Blasting And Bailing Water Wherever Necessary. Refilling The Sides Of Foundation With Excavated Earth Other Than Sand In Layers Of Well Rammed And Compacted And Depositing The Surplus Earth In Places Shown By The Departmental Officers With An Initial Lead Of 10M And Initial Lift Of 2M And Clearing And Leveling The Site Etc. Complete Complying With Standard Specification. , Supplying And Filling In Foundations And Basement With Filling M- Sand In Layers Not Exceeding 15 Cm.Thick,Well Watered,Rammed And Consolidated Etc. Complete Complying With Standard Specifications. , Plain Cement Concrete 1 : 4 :8 ( One Part Of Cement, Four Parts Of Sand And Eight Parts Of Hard Broken Stone ) Using 40 Mm Gauge Hand Broken Hard Broken Granite Stone Jelly Complying With Standard Specifications In Foundations And Basement. , Refillingtheapprovedgoodqualityearthin Plinths,Areadevelopmentetc.Wherever Specifiedinlayersisnotexceeding200mm Thick, With Available Earth At Site. , Supplyingandfillingof Goodearthfilling Locallyavailableearthtransportedfromthe Outside Including Consolidation,Leveling Specified Inlayersofnotexceeding200mm Thick., Etc. Complete. , Supplyingand Erecting Centeringand Shuttering For Soffits Including Necessary Supportsandstruttingupto3mheightfor Planesurfacesasdetailedbelowinallfloors With All Cross Bracings Using Mild Steel Sheets Ofsize90x60cmand10bgstiffenedwith Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Ofsize10cmx6.50Cmspacedatabout 90 Cm Centre To Centre And Supported By Casurina Propsof10cmto13cmdiaspacedatnot More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specification.(Paymentforcenteringshallbe Given After The Concrete Is Laid). , Footing, Plinth Beam, Etc. , Plainsurfacessuchasroofslab,Floorslab, Beams,Lintels,Loft,Sillslab,Staircasewaist, Portico Slab And Other Similar Works. , Squareandrectangularcolumnsandsmall Quantitiessuchassunshades,Parapetcum Drops, Window Boxing, Fin Projections And Other Similar Works. , Cement Concrete 1:1-1/2:3 (One Cement, One And A Half Crushed Stone M.Sand And Three Hard Broken Stone Jelly) Using 20 Mm Gauge Hard Broken Granite Stone Jelly For All Rcc Items Of Works Excluding Cost Of Reinforcement Grill And Fabricating Charges Centering And Shuttering But Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor / Roof Slabs Wherever Necessary And Bearing Surfaces Of Walls, Beams Etc. Shall Be Finished Smooth With Cement Mortar 1:3 (One Cement And Three M.Sand) And Kraft Paper Laid Over It Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers , Foundation & Basement , Ground Floor , Steel - Fe 500 : Supply, Fabrication And Placingofreinforcementsteelofhighyield Strength Ribbed Barsof Variousdiameters And Gradeconformingtois1786forreinforced Concretework.Theworkincludesrecoiling, Straightening, Cutting, Bending, Fabricating, And Placinginposition,Atalllevelsincludinglead Andlift,Accordingtodrawings,Specifications Etc.Complete Andsupply &Use Of18g Black Annealedbindingwiredoublefoldtotiethe Bars In Position And Providing Precast Cement/ Pvccoverblocksformainreinforcementto Ensure Specified Cover And Complete., Includingalllaborchargesetcasdirectedby Departmental Officers. , Brick Work In Following Cement Mortar 1:5 Using Best Quality Iiclasstablemoulded Bricks83/4X41/4X23/4Forfoundation Andbasementincludingcuringetc.,Complete Complying With Standard Specification.Including Scaffolding Curing Cost Of Reinforcement Etc.All Completeasperspecificationsanddrawings As Directed By The Engineer In-Charge. , Foundation Basement , Ground Floor , Brick Partition Walls Of 11.50Cm Thickness Using Best Qualityii Class Table Moulded Bricks 83/4 X 41/4 X23/4 In Cement Mortar 1:3 (One Cement And Three Sand) Using Hoop Iron Reinforcement If Found Necessary Including Curing Etc. Complete And As Directed By The Departmental Officers. , Supplying And Applying Of Two Coats Of Putty Of 3Mmthickovertheexposedrccsurfaceof Ceilingincludingfinishingthejointssmoothy With Grinding Machine And The Surface Shall Be Thoroughly Cleaned Out Of Dust And Scrubbing. Thesurfaceshallthenbeallowedtodryfor Atleast 48 Hours.It Shall Then Be Sand Papered (Waterproofabrasive Sheet) To Give A Smoothandevensurface. Anyunevenness Shallbemadegoodbyapplying1stcoatof Puttymixedwithwaterontheentiresurface Includingfillinguptheundulationsand Applying 2Nd Coat Of Putty After 6 Hours Of 1St Coatofputtyandthensandpapering (Waterproof Abrasive Sheet) The Same After It Is Dryandfinishingthesurfacesmoothly,Etc., Completecomplyingwithstandard Specifications And As Directed By The Departmentalofficers.[Theratesare Inclusive Of Hire Charges For Grinding Machine , Providing&Applying12mmthick Cement Plaster In Cm 1:5 (1 Part Of Cement: 5 Parts Of Sand)Towallsinternallyinsinglecoatatall Levels To Correct Line And Level Including Chickenwiremeshatalljointsofbrickand Concretesurfaceswithminimumoverlapof 150 Mm In All Directions, Scaffolding, Rounding Off Or Chambering Of Corners, Offsets, Fin/ Bands,Projections,Etc.Andcleaningof Surface,Rakingoutjoints,Rougheningof Surface, Chiselingtheundulatedsurface Wherever Necessary Andcuring,Etc., All Materialsandlaborcompleteinallrespects Includingalllead,Liftanddescentand As Directed. , Providing&Applying12mmthick Cement Plaster In Cm 1:5 (1 Part Of Cement: 5 Parts Of Sand)Towallsexternallyinsinglecoatatall Levels To Correct Line And Level Including Scaffolding, Rounding Off Or Chambering Of Corners,Offsets,Fin/Bands,Projections,Etc. And Cleaning Of Surface, Raking Out Joints, Roughening Of Surface,Chiseling The Undulated Surfacewherevernecessaryandcuring,Etc., All Materials And Labor Complete In All Respects Includingalllead,Liftanddescentand As Directed. , Paving The Floor With Best Quality Vertified Tiles Of Size 600 X 600 X 8Mmof Approved Colour, Shade And Quality Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone M.Sand) 20Mm Thick In All Floors And The Top Pointed With The White Cement Mixed Same Colour Pigments Etc., Complete Complying With Standard Specification.(The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Providing Granolithic Floor Finish Of Thefollowing Thickness With Plain Cement Concrete 1:2:4 (One Cement, Two Sand And Four Aggregate) Using 10 To 12Mm Gauge Hard Broken Stone Jelly Including Laying, Finishing And The Top Rubbed Smooth With Power Trawl, Thread Lining,Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Rate Is Inclusive Of Necessary Planking For Panellingwherever Necessary And As Directed By The Departmental Officers). , An Ms Square Bar Of 12Mm Size Is Welded To The Inner Face Of The Window At An Equal Interval Not Exceeding 100Mm Edge Between Them. All Members Are Painted With One Coat Of Anti-Corrosive Red Oxide Primer As Directed By The Departmental Officers.All Sections Should Be In Confirmed With Is 7452/1990.The Cost Includes Cost Of All Materials, Labour Charges And Other Incidental Charges, Etc., Complete , Manufacturing, Supplying And Fixing Of Steel Doors With Following Specification.Ms Angle Of Size 40X40x6mm At 3.5 Kg/M Used For Outer Frame And Ms Angle Of Size 35X35x5mm At 2.6 Kg/M For The Shutter Frame.Stiffeners With 32X6mm At 1.5 Kg/M Ms Flat Is Provided As The Lock Rail Of The Door And Welded Intact On Both Ends To The Shutter Frame.18 G Cr Sheets Of Best Quality Is Laid As Panel In The Shutter Frames.18X5mm At 0.70 Kg/M Ms Flat Is Welded Over The 32X6mm At 1.50Kg/M Ms Flat On The Rear Side Of The Door, Sandwiching The Cr Sheet For Rigidity. Additional Stiffeners With 18X5mm At 0.7 Kg/M Ms Flats Are Provided Diagonally On The Rear Side Of The Shutter. 300Mm Length Of Hinges 2Nos, For Shutter Is Provided.6 Nos. Of 250Mm Length Hold Fasts 200Mm Length Specified At The Ends Are Welded To The Outer Frame Of The Door. Tower Bolt 2 Nos. At The Top Provided. , Supplying And Painting New Ceiling Plastered Surfacewithtwocoatsofdistemperingone Coat Of Distemper Primer , Supplying And Painting New Plastered Internal Wallsurfacewithtwocoatsofdistempering One Coat Of Distemper Primer , Supplying And Painting The Walls With One Coat Of Wall Primer And Two Coats Of Exterior Emulsion(Apexorequivalent)Asinstructed By The Departmental Officers Including Preparation Of Surface Curing, Etc., Complete In All Floors Complying With Standard Specifications(Thecolourandshadeofthe Cementpaintshallbegotapprovedbythe Executive Engineer Before Use Of Work). , Weathering Course Concrete Using Best Qualitybrokenbrickjellyof20mmuniform Gaugeinpureslakedlime(Nosandtobe Used ( Over The Rcc Roof Slab In The Proportion Of Brick Jelly To Lime Being 32 : 121/2 By Volume Laid Over In Single Layer And Consolidated To The Required Slope And Finished Thickness And Beatingtheconcretewithwoodenbeatersof Approved Pattern, Keeping The Surface Constantly Wet By Sprinkling Lime, Jiggery Water Etc. Complete Complying With Standard Specifications And As Directed , Finishingthetopofroofwithonecourseof Machine Pressed Tiles Of Size 230Mm X 230Mmx20mmofapprovedqualitysetin Cementmortar1:3(Onecementandthree Sand)12Mmthickmixedwithwaterproofing Compound Conforming To Iss At 2% By Weight Of Cement Used And The Joints Pointed Neatly To Full Depth Of Tiles With The Same Cement Mortar Mixed With Red Oxide And Water Proofing Compound Including Curing Etc., Complete Complyingwithstandardspecificationandas Directed By The Departmental Officers. , Paintingnewironworkssuchassteeldoors, Windows, Ventilators, Window Bars, Balustrades Etc., With Two Coats Of Best Approvedfirst Qualityandcolourofsyntheticenamelpaint Overtheexistingredoxideprimingcoatinall Floors Excluding Cost Of Priming Coat Etc., Completecomplyingwithstandard Specification. (The Make, Quality And Colour Of Paint Should Be Got Approved By The Executive Engineer Before Use On Works.) , Supplyingandfixingcuddapahslabfor Cupboard Shelf , Supplying And Fixing Pvc Rain Water Down Fall Pipes Of Following Dia Meter Etc., Complete. , Sub Estimate For Electrification , Wiring 2 X 1.5 Sq.Mm (22/0.30)Pvc Insulated Unsheathed Sc.Cu.Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Pvc Accessories With Tw Switch Box With In Flush With Wall Covered With Hylem Sheet Of 3 Mm Thick With Painting Of Suitable Colour For Concealed Pvc Light/ Fan Point (Sd No.25) , Supply And Fixing Of4-18Wled Tube With Fitting Inclusive Of All Charges M1211 , Wiring 2 X 1.5 Sq.Mm (22/0.30)Pvc Insulated Unsheathedsc.Cu. Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Pvc Accessories With Tw Switch Box With In Flush With Wall Covered With Hylem Sheet Of 3 Mm Thick With Painting Of Suitable Colour For Concealed Pvc Plug Point (Sd No.38) 5 Pin Plug Point , Supply And Fixing Of 1200Mm Sweep Ac Ceiling Fan Complete With Stepped Electronic Regulator With 300Mm Down Rod On The Existing Clamp Sd 106 , Supply And Fixing Of Water Tight Bulk Head Fitting With Guard (Philips / Bajaj / Crompton / Klite) Suitable For Incandencent Lamp And 15W Bulb (Sd N0.83) , Supply And Run Of 2 Of 1.50 Sq.Mm Polythene Insulated Pvc Sheathed Heavy Duty Sc Copper Conductor Of 1100 V Grade On 7/20 Gi Bearer Wire For Service Connection Mains (Sd No.64) , Supply And Fixing Of Tneb Meter Board Suitable For 32A Single Phase Service Connection With 32A Fuse Unit (500V) 32A Neutral Link And Earth Link (1 X 1/8 Copper Flat) On Tw Plank Of Size 375Mm X 300Mm X 19Mm With Supporting Tw Reepers Of 1 Thick An Either Side With Painting With Suitable Bolt And Nuts For Fixing The Tw Plank On Wall With Earth Connection And Inter Connection With 7/20 Pvc Insulated Copper Wire From Eb Meter To Fuse Unit. (Sd No. 125) , Supply And Run Of 2X4 Sqmm (22/0.3) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100V Grade In 25Mm Dia Gi Pipe (Class B) Suitably Bent At Both Ends With Necessary Angle Iron Upright And End Supports For Mains Sd 70 , Gst Amount For Providing Service To Government Contract Works For The Above Construction Works. { Gst Amount Is The Total Gst Amount For Total Overall Quoted Amount Above This Row In Column Bb For All Works In This Package}

Key Value

Document Fees
Refer document
EMD
INR 5000.0 /-
Tender Value
INR 5 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail