Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-08-2025 | Amendment1 | Other | 14-08-2025 |
| 2 | 29-07-2025 | Amendment | Other | 14-08-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling ofAsbestos cement (corrugated, semi-corrugated etc) sheets in roof covering complete all as specified and directed. |
| 2 | S&F forPre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thickhaving tensile strength of 550 Mpa as in roof covering/ridge/ cladding to wall, fixed with self tapping screw (Heavy duty) with in built washers and neoprene & EDPM washers, in roofs, walls etc complete all as specified and directed. |
| 3 | S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet .50 mm thick of an colour having tensile strength of 550 mpa as in ridges ,hips,valley gutter,drip or straight fastening etc fixed with self tappingscrew etc complete all as specified and directed. |
| 4 | Demolation of wall and ceiling boards ( Fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 5 | Providing and fixing false ceiling in repair of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width complete all as specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc 0.18 Sqm but n exc 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 15mm thickfor laying floor finishes of cement mortar1:6 complete all as specified and directed. |
| 8 | M&L for Glazed ceramic tiles in vertical surfaces of size 300 x 200 x7 mm thick,set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surface including 15 mm thk backing coat in cement mortar 1:4 including taking down the existingcomplete all as specified and directed. |
| 9 | Renewing Glazed tiles in patches,area n.exceeding 5Sqm including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 10 | M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) incuding pointing in white cement (1:2) using marble dust withadmixture of pigment to match with shade of granite including 15mm thick screed bedin cement mortar 1:4 complete all as specified and directed. |
| 11 | S&F for powder coated aluminium sliding windows three track with two sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as specified and directed. (A) FRAME:-(i) Top and side member fortwo track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal.(ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal.(B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal.(ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal.(C) Sliding shutter to be provided with 5.5 mm thick sheet glass complete all as specified and directed. |
| 12 | (D) Supply & Fix for 6.5 mm thick aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium \"U\" channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii)Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm. (E)S&F for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat complete all as specified and directed. |
| 13 | M&L for aluminium ventilator frames with frame of section 100mm x 44 mm of thickness 1.6 mm shutters of section32 mm x 15mm (with and including half portion fixed glazed shutterand rest half portionlouvered with glazedshutter) including stainless steel wire mesh, rubbergasket for securingthe glass, 5.5 mm thick figuredglass, aluminium grill and necessary aluminiummongaries and handles includingnecessary lockingarrangment complete all as specified and directed. |
| 14 | Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 15 | Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames complete all as specified and directed. |
| 16 | Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frame complete all as specified and directed. |
| 17 | Taking down and refixing in the same opening ,resecuring or easing &adjusting of shutters exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed. |
| 18 | Taking down shutters of any description exc 1 Sqm but n.exc 2 Sqm complete all as specified and directed. |
| 19 | S&F for Fe-410-W(Gde-E-250)quality B for fabricationframed work as in door or gates of angle or other sectionwith gusset plate rails, braces, etc complete drilledfor fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either fooks and hinges or steel hanging door fittings (exclusiveof steel, sheetingor other covering rumming railsand guides) hanging, also fasteningand fixing complete all as specified and directed. |
| 20 | S&F for Fe-410-W(Gde-E-250)quality B joist, channel, angle or tee sections, fixed independently with out connecting plates etc (cut to ordinary lengths i.e. with in 20 mm of length indicated) complete all as specified and directed. |
| 21 | S&F for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 22 | S&F for Solid PVC Double door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with MS tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 23 | S&F for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design witht 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 24 | S & F for Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 25 | S&F for 35mm thick 2nd class HW factory made plain, framed, panelled shutter (two panel) with lock rail and panels of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 26 | S&F in repair 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side withdecorative choice lamination & other side balancing white lamination, as in cupboard shelves /door shutters, etc complete all as specifed. Including taking down existing complete all as specified and directed. |
| 27 | S&F for 2nd Class HW glazed and skeleton shutter 35 mm thick, open rebated & prepared to receive glass, gauze, etc (rebated sash bars) edges of framing plain, chamfered or rounded fittted with cut and mitred beads for securing glass etc size of members of shutters as specifed in SSR Part I, Section 8 clause 8.24 (a) supplied and fitted to chowkhats complete all as specified and directed. |
| 28 | S & F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 29 | M&L for plywood 12 mm thick, veneered decorative plywood, grade 1 (with BWR resin)with decorative face veneers on both faces fixed with screws to timber frame work complete all as specified and directed. |
| 30 | M&L for 2 coats of synthetic enamel painting to new wooden surfaces over a coat of pink primer over 10cm width or girth including preparation of new surfaces complete all as specified and directed. |
| 31 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 32 | M&L for providing PCC 1:3:6 tupe C-1(using 20 mm stone aggregate), in cement mortar 1:4 lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates complete all as specified and directed. |
| 33 | S&F for Aluminium, anodised, barrel tower bolts of extruded section of 150 mm long complete all as specified and directed. |
| 34 | S&F for 150mm aluminum anodised cast type bow handles complete all as specified and directed. |
| 35 | S&F for 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. |
| 36 | S&F for 100mm butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 37 | Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed. |
| 38 | M&L for Painting tonew steel Surfaces of any description, over 10cm in width or grith with two coat of synthetic enamel paint over a coat of red oxide, not otherwise described complete all as specified and directed. |
| 39 | M&L for Taking down of cement plaster of any descriptionand in any postion including racking out joints for key scrubing with water etc complete all as specified and directed |
| 40 | M&L for 15mm thick rendering in cement mortar 1:4 in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and directed. |
| 41 | Supply only integral water proofing compound complete all as specified and directed. |
| 42 | M&L for rendering 10mm thick in cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 43 | M&L for 5 mm thick rendering incement mortar 1:3on fair faces ofconcrete surfaces such assoffits of slabs, ceiling etc, in patches n.exc 1 Sqm each finishing the surfaces fair and even complete all as specified and directed. |
| 44 | M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion overalkali resistant primer complete all as specified and directed. |
| 45 | M&L for complete removal of existing treatment of plastered surfaces of ceiling and applying three coats of white wash including preparation of old surafaces complete all as specified and directed. |
| 46 | M&L forpreparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying two coat of distemper oil emulsion over one coat of wall care puttyincl complete removal of existing treatment complete all as specified and directed. |
| 47 | M&L for preparing new surfaces and applying two coats of distempering walls with distemper oil emulsion, white or tinted complete over chalk whitening, on plastered surfaces to internal walls complete all as specified and directed. |
| 48 | M&L for Preparing oldplaster surfaces(external face) of walls and applying one coat of all weathercement based paint complete all as specified and directed. |
| 49 | M&L for Preparing newly plaster surfaces(external face) of walls and applying one coat cement based paint over a coat of alkali resistance primer complete all as specified and directed. |
| 50 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness(below or above ground level) including removal of debris from the site complete all as specified and directed. |
| 51 | M&L for 75 mm thick, PCC (1:3:6) type B-2 using 40 mm graded stone aggregates as in sub base/ Plinth protection ,surface finished fair and smooth with out usig extra cement complete all as specified and directed. |
| 52 | M&L for chequered cement concrete tileswith grey cement and pigments 20 cm x 20 cm x25 mm thick, set jointed and pointed in neat cement slurry to be laid over screed bed complete all as specified and directed. |
| 53 | Taking up or down GI tubing 15mm bore including cleaning for refixing complete all as specified and directed. |
| 54 | Taking up or down GI tubing 20mm bore complete all as specified and directed. |
| 55 | S&F for 20 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 56 | S&F for 15 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 57 | M&L for cutting chases for concealed water tubing and making good to facing in cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed. |
| 58 | M&L for sunken floor treatment as follows as per S. No. (i) to (v) :- The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.(i) Demolition ofconcrete of any description and in any position not otherwise specifically provided or in anytype of filling in sunken portion & cleaned the sunken potion incl vertical wall surface complete all as specified and directed.(ii) Top of RCC salb in sunken portion including peripheral beams shall be plastered with 15 mm thick cement and sand mortar (1:3) using approved water proofing compund @3% by weight of cement finished even and smooth without using extra cement and curved adequately and allowed to dry. (iii) Two coats of epoxy resin / polymer modified cementaticious coating like brush bond of Fosroc or equivalent both on floor and walls /beams shall be applied as per manufacturer instuctions.(iv)slabs to be given 1:20 slope outward with 25 mm GI pipe spout with 300 mm projection beyond outer surface of wall completeall as specified and directed.(v) After the surface is passed by the Eng- in- charge for water tightness by flooding for 72 hrs the same shall be filled with lean concere (1:4:8) using type B-1 aggregate, up to the required depth . Surface surrounding to WC Pan shall however be of cement concrete as specified here-in-before. |
| 59 | Taking down of existing roof treatment from roof and terrance, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following specification:-(a) Applying cement slurry over concrete surfaces @3kg/sqm. (b) Roof surface shall be plasterd with 15 mm thick cement mortar 1:4 screed bed over slab when concrete is still green.(c)Curing of slab with ponding with water shall be done all as specified. Ponding test 72 hrs shall be done.(d)Clening of plastered roof surface and applying one coat of cold bituminous primer @ 0.25 Ltr/Sqm conforming to IS: 3384:1986.(e) A layer of APP based polymeric membrane, 3 mm thick (minimum) weight 3.0 kg/Sqm reinforced with polyester non woven fabric (weight not less than 160 gm/sqm) shall be applies over bituminous primer as specified above application of polymeric membrane shall by torch application. The overlabs shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (f)One coat of aluminium paint over the APP modified membrane @ 0.11 Kg per suqare meter. |
| 60 | S&F in repairrotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 ltr capacity hoisted and fixed in position with air pipe all as specified including dismantling old one complete all as specified and directed. |
| 61 | S&Fin repair 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board of commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 62 | S&F in repair 15mm Bore bib tap cast copper alloy chromium plated fancy type with crunch or butterfly handle screw down scrwed for iron piupe or for brass funnel and fixed, in repaircomplete all as specified and directed. |
| 63 | S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 64 | S&F in repair Stop valves, fancy type,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed. |
| 65 | S&F in repair brass chromium platedtubular towel rail, 20mm dia,60cm long between flanges complete all as specified and directed. |
| 66 | S&F in repair PVC low level flushing cistern, white, 10 ltrs capacity with float valve and brackets complete including fixing low level flush pipe after dismantling of old unserviceable existing flushing cistern complete all as specified and directed. |
| 67 | S&F forVitreous china wash hand basin size 550x400mm (flat back or angle back type) including 32mm dia brass chromium plated waste fitting a pair if cast iron bracket duly painted/ erecting stand including cutting and pinning in ends making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable wash hand basin and connected items of any description complete all as specified and directed. |
| 68 | S&F for 15mm bore dia pillar taps, fancy type chromium plated with capstan heads chromium plated screwed down high pressure, with or without lettered \"hot or cold\" with long screwed shank and fly nuts screw for iron pipe complete all as specified and directed. |
| 69 | Dismentling and breaking up drain pipes AC /CI /PVC Pipes set in cement mortar 100mm/75mmbore complete all as specified and directed. |
| 70 | M&L for 75mm PVC (SWR) floor trap, with grating including jointing with solvent cement complete all as specified and directed. |
| 71 | S&F for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 110mm bore, complete all as specified and directed. |
| 72 | S&F for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 75mm bore complete all as specified and directed. |
| 73 | S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 74 | S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 75 | S&F for PVC (SWR) single T equal or unequal with access door 110mm bore complete all as specified and directed. |
| 76 | S&F for PVC (SWR) single T equal or unequal with access door 75mm bore complete all as specified and directed. |
| 77 | S&F for PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 78 | S&F for 40mmdia waste pipe for sinks, basins, etc complete all as specified and directed. |
| 79 | S&F for grating doom 100/125 mm dia of PTMT (Minimum weight 5gms) complete all as specified and directed. |
| 80 | S&F in repair vitreous china 580x440 mm, \"ORISSA PATTERN\" with \"P\" or \"S\" trap size squatting pan (Exclusive flushing cistern and flush pipe) incl foot rest complete and provision of lime concrete bedding complete all as specified and directed. |
| 81 | M&L for complete removal of loose/ cracked concrete including reinforcement if required from RCC roof projection, chajja, fins, facia etc and making good with PCC (1:1.5:3) type A0 using 12.5 mm graded aggregate) in any slab and in any position finsihed the surface even and smooth with out using extra cement including necesary formwork and weldign/binding of reinforcement (including reinforcement) if required complete all as specified and directed.Note : reinforcement will be measured and paid seperately under respective items. |
| 82 | M&L for Mild steel TMT bars 5 mm to 10 mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips complete all as specified and directed. |
| 83 | Demolition of Brickwork or stone/ boulder masonary ,built in cement mortar or cement lime mortar complete all as specified and directed. |
| 84 | M&L for brick work built in cement mortar 1:6 straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 85 | S&F in repair 20 mm bore ballbrassvalve,high pressure with polythene float and fly nut complete,screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 86 | Hacking out old broken glass any thickness, size quality or description from wooden/steel frame fixed in repair with wooden beads/metal pinning andS&F for 4 mm thick sheet glass in square not exc. 0.50 sqm in each pane, fixed with wooden beads or putty (in metal frames etc) complete all as specified and directed. |
| 87 | S&F in repair Curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 88 | S&F in repair20 mm dia Gun-metal, globe or gate valves ,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 89 | Disconnecting existing tanks exc 500 & not exc 1000 Ltr, setting aside (orlowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in postion (cleaning repairing etc measured separately) complete all as specified and directed. |
| 90 | M&l for 75 mm thk cement concrete type D-2, 1:4:8 as in sub floors, sub bases,floors and paving etc complete all as specified and directed. |
| 91 | M&L for providing precast cementconcrete Type B1( 20 mm graded stone aggregate) set in cement mortar 1:6 in landings,cover slabs (for manholes etc) chullah hoods,chajjahs water troughs,mangers,shelves and similar articles with plain faces complete all as specified and directed. |
| 92 | S&F for steel plate rack of size 600x 900x 250mm complete all as specified and directed. |
| 93 | S&F in repair Chromium plated shower rose 195 mm size with or without swivel joint including fixing to steel pipe or union complete all as specified and directed. |
| 94 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum in soft/ loose soil, getting out, returning,filling in and ramming earthor brilen rubble mixed with earth around, inlayers not exceeding 25 cm, eatering, and removing surplus soil to a distance n.exc 50mtrand making good surface complete all as specified and directed. |
| 95 | M&L for RCC nominal mix Type B-1 1:2:4 (20mm graded stone aggregate)as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 96 | S&F in repair waste coupling of 40mm dia of PTMT (half or full threaded) minimum wt 32 mm-45gms/40mm-60gms complete all as specified and directed. |
| 97 | M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over 15 mm thk cement screed bed of cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of inclulding rubbing and polishing complete all as specified and directed. |
| 98 | M&L for Kota stone slab 20-25 mm thick Kota stone slab flooringover 15 mm thk cement screed bed of cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of inclulding rubbing and polishing complete all as specified and directed. |
| 99 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 100 | M&L for broken stone or boulder hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 101 | Taking down carefully copper/aluminum point wiring (light, fan and power socket etc) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, calling bells etc removing materials for takingcredit and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 102 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 103 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 104 | Taking down carefully ceiling fan, sealing cable ends,dismantelling blades removing fan and blades for taking to store and refixing back to its original position and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 105 | M&L for point wiring with 1.5 sqmm cable PVC insulated unsheathed type, copper conductor, multistranded cable (FRLS type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 Volts grade unsheathed PVC insulated (green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC casing capping, medium grade of suitable size including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover/ plastic gang box for mounting of switch, socket and fan regulator complete all as specified and directed for following:- |
| 106 | Light/Fan point controlled by one no one way switch complete all as specified and directed. |
| 107 | One light point controlled by two 2-way switches complete all as specified and directed. |
| 108 | 5 Amp Socket on Same board complete all as specified and directed. |
| 109 | 5 Amp socket point on independent switch board complete all as specified and directed. |
| 110 | All as per item Srl No. 104, but with 2.5 Sqmm cable for one 15 A socket point on independent board complete all as specified and directed. |
| 111 | S&F for switch 2 way 6 Amps,230 volts, 50 HZcomplete all as specified and directed. |
| 112 | S&F for switch piano flush type 1 way 5/6 Amps,230 volts, 50 HZcomplete all as specified and directed. |
| 113 | S&F for switch socket combination 3 pin 5/6 Amps, piano flush type 230 V complete all as specified and directed. |
| 114 | S&F for switch socket combination, multipurpose type 6 pin 5/15 A240 Volts piano flush type complete all as specified and directed. |
| 115 | S&F for ceiling rose surface type bakelite 3 terminals 230 volts AC complete all as specified and directed. |
| 116 | S&F for step type electronic fan regulator piano flush type, 230 volts, 5 speed control complete all as specified. |
| 117 | S&F for LED lights fitting 1 X 18/20 W, 6500 K, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old one all as specified and directed. Make : Havells Cat Part No:- LHEXAPP7PN1W020. |
| 118 | S&F for of wall mounted endura linear, decorative ultra slim square profile LED 10 watt, 6500 K, 230 volts, 50 Hz lighting fixture with extruded polycarbonate lighting fixture, environmental friendly,energy efficient ready to use pack including lamp complete all as specified and directed. Make : Havells Cat Part No. LHEXACP7IN1W010. |
| 119 | S&F for bulk head luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge -lit LED luminaire comprising of high brightness LEDs 10 watt, 230 volts, 50 Hz including lamp, connection wire all as specified and directed. Make : Crompton Cat Part No. LBHE-10-CDL. |
| 120 | S&F for bell push switch, piano flush type 5 amps, 240 volts, single pole complete all as specified and directed. |
| 121 | S&F forlamp holder with 9 watt Inverter type LED bulb PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. |
| 122 | S&F for sheet metal enclosure, MCB DB, double door, single pole & neutral, 8 way, 230 volts, 50Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 123 | S&F for MCB SPN 32 Amps, 230 volts, C - curve, 10 kA complete all as specified and directed. |
| 124 | S&F for MCB SP 10 to 32 Amps, 230 volts, C curve, 10 kA complete all as specified and directed. |
| 125 | S&F for MCB TPN 40 to 100 Amps, 230 volts, C curve complete all as specified and directed. |
| 126 | S&F for sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type including taking down old one complete and making good of disturbed surface complete all as specified and directed. |
| 127 | Taking down of geyser of any capacity from surface/wall including fixing to its original position with inlet and outlet connection complete all as specified and directed. |
| 128 | S&F for submain wiring with 2 X 4.0 Sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 4.0Sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 129 | S&F for submain wiring with 2 X 6.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 6.0sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 130 | M&L in repair of earthing complete with galvanised steel earth plate electrode 600mm×600 mm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point/ DB including necessary earth work, common salt, char coal and earth pit as per electrical plate No. 3 of SSR Part-I complete all as specified or indicated point including testing on completion complete including dismantling old complete all as specified and directed. |
| 131 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 132 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread complete all as specified and directed. |
| 133 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. |
| 134 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: Punned thickness of sand shall be measured & paid. |
| 135 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 136 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 50 mm bore complete all as specified and directed. |
| 137 | S&F in replacement GI protection pipe of 40 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed.Note: Earth work shall be measured and paid separately. |
| 138 | Taking out old serviceable/ unserviceable cable of size 25 Sqmm, 4 core of any make/ typefor requisite replacement/ further disposal complete including taking out bricks complete all as specified and directed. |
| 139 | Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor,25 sqmm,4.0 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 140 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy