|
| 1 | ITEM |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, for all lift, including getting out the excavated soil and disposalof surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 4 | Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thicknesswith total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 5 | CEMENT PLASTER (IN COARSE SAND) 20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources) |
| 8 | Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 11 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not lessthan 12.50 kg/sqm) |
| 12 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 13 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% andconforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarsesand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cutwith the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelingsystem and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size. Size of Tile 600 x 600 mm |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 15 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 16 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including waterthinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 18 | Providing and fixing tiled false ceiling of specified materials of size595x595 mm in true horizontal level, suspended on inter locking metal gridof hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm,both side inclusive) consisting of main “T” runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mmthick (minimum) sheet, spaced at 1200 mm center to center and cross“T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main“T” at 600 mm center to center to forma grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlockedat middle of the 1200x600 mm panel to form grids of 600x600 mm andwall angle of size 24x24x0.3 mm and laying false ceiling tiles of approvedtexture in the grid including, required cutting/making, opening for serviceslike diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm GI adjustable rods with galvanised butterfly level clips ofsize 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T,bottom exposed width of 24 mm of all T-sections shall be pre-painted withpolyester paint, all complete for all heights as per specifications, drawingsand as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global whitecolor tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm(both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factorypainted after bending. |
| 19 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 20 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution |
| 21 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 23 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 24 | PE-AL-PE COMPOSITE PRESSURE PIPE Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS : 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. INTERNAL WORK - EXPOSED ON WAL 4050 (50 mm OD) pipe |
| 25 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore |
| 26 | Dismantling C.I. or asbestos rain water pipe with fittings and clampsincluding stacking the material within 50 metres lead : 100 mm dia pipe |
| 27 | Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, madefrom rigid foam sheets (Single extruded) having density 600 Kg/cumand laminated on both side by laminate Sheet/PVC foil lamination. Theexposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screwholding capacity. Shutter shall be fixed to frame using approved hingeswith necessary stainless steel screws, all complete as per direction ofEngineer-in-charge. |
| 28 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 29 | Providing and fixing unplasticised -PVC pipe clips of approved designto unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length, including cuttingbrick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) andmaking good the wall etc. complete. 110 mm |
| 30 | Providing and fixing angle iron frames for doors windows and ventilators id mild steel angles sections of size 35 x 35 x 5 mm, joits mitred and welded by angle iron 35 x 35 x 5 mm of 35 x 5 mm flat pieces of the exisitng t- iron frame or the wall with dash fastner, including fixing of necessary butt hings and screws and applying a priming coat of approved steel primer all complete as the direction of Enginner - In - Charge |