Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | B-1/1.28:- Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil |
| 2 | B-1/1.8:- Earth work in excavation by mechanical means (hydrolic excavator)/manual means in foundationtrenches or drains (not exceeding 1.5 m in width or 10sum on plan) including dressing of sides andramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kinds of soil. |
| 3 | B-3/3.1.6:- Providing and laying in position cement concrete including curing compaction etc. Complete in specified grade excluding the cost of centrering and shutteting -All work up to plinth level (A) 1:4:8 (1 cement 4 coarse sand : 8 graded stone aggregate 40 mm Nominal size.) |
| 4 | B-11/11.26:-Random rubble stone kharanja under floor. |
| 5 | B-6/6.1.6:- Random rubble stone masonry for foundation and plinth in cement sand morter above 30 cm thick wall in:- Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 6 | B-14/14.9.2: Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 7 | B-4/4.1: Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix |
| 8 | B-4/4.9: Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 9 | B-4/4.3 : Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix |
| 10 | B-4/4.10.2: Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 11 | B-4/4.13.2: Providing and fabricating reinforcement for R.C.C. work includingstraightening, cutting, bending, placing in position and binding(including cost of binding wire) all complete up to floor five level.Hot rolled deformed bars (IS : 1139). |
| 12 | B-5/5.2.2 : Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 13 | B-5/5.8.3: Half brick masonry in Superstructure,using bricks of designation 75 in CM 1:6 upto third storey. |
| 14 | B-14.2.1:-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix. |
| 15 | B-10/10.17.1 :-Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 16 | B-10/10.22:Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 17 | B-12/12.7:- Finishing with neat cement (punning). |
| 18 | B-9/9.19.3 : Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) . |
| 19 | B-9/9.26 : Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 20 | B-9/9.27 : Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 21 | B-9/9.5 : Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 22 | B-11/11.18.2: Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm |
| 23 | B-6/6.17.3 : Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Kota stone minimum 30mm thick. |
| 24 | B-8/8.13.2.1 : Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure \"A\" :comercial veneer both side 30 mm thick . |
| 25 | B-9/(9.17.1+9.17.2) : Providing and fixing M.S. sheet double leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint M.S. Shhet 20 S.W.G. |
| 26 | B-12/12.3.3:- Plaster on new surface on walls in cement sand morter 1:6 including racking of joint etc. Complete fine finished (A) 20 mm thick. |
| 27 | (B) 12 mm thick |
| 28 | B-12/12.5 : 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement :3 fine sand). |
| 29 | B-13/13.1:- Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 30 | B-13.29 Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- Sqm 1568.00 (i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. (ii) Applying Epoxy primer on the exposed steel bars. (iii) Applying Epoxy hardener and resin mix (as per manufectured\"s specification) on concrete and steel bars with brush. (iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day. (v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. (vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. |
| 31 | B-12.35.7:-Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ). |
| 32 | B-12/12.22.1&2:- Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete (A) New Plastered Surface (three or more coats) |
| 33 | (B) Old Plastered Surface (two or more coats) |
| 34 | B-12/12.37.1:- Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. |
| 35 | B-12/12.42:- Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 36 | B-12/12.41.1:-Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 37 | B-12/12.45.1: Applying priming coat : With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. |
| 38 | B-12/12.46.1&2:- Painting with enamel paint of approved brand and manufacture to give and even shade : (A) One or more coats on old work. |
| 39 | (B) Two or more coats on new work |
| 40 | B-11/11.38.3(A): Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) : M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc : Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 |
| 41 | B-12/12.65: Spray painting in approved shade and approved qualitywith Duco paint of required colour to give even shade with two or more coats by compressor including sand papering, NC putty filler coat etc complete in all respect as per design given by Engineeer incharge on new work. |
| 42 | B-13/13.4.1: Renewing glass panes,with putty and nails wherever necessary : Float glass panes of thickness 4 mm |
| 43 | B-3/3.8:- Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : |
| 44 | B-13/13.33.(a).(ii) Repairofdoor,windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : Style / rail of teak wood 30mm thick/ Aluminium Section 6\" wide |
| 45 | B-7/7.12 :Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 46 | B-7/7.13+7.14 :Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 47 | S-1/1.2.2:- P&F indian type white glazed vitreous china 1st quality W.C. orissa pan (IS: 2556 Mark) with 100 mm viterious china Por S trap including cutting and making good the wall and floor. Size 580x440mm. |
| 48 | S-1/1.36.4:- P&F WVC wash basin 1st quality (IS:2556 mark) of approved make with CI brackets duty painted one no. 15 mm CP piller cock (IS: 8934 mark) & 32 mm CP brass waste coupling of approved make 25 mm dia GI waste pipe complete including cutting and making good the wall. size 580×450 mm. |
| 49 | S-2/2.37.1+2.37.3:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)(a) 15 mm dia nominal bore. B Class |
| 50 | (b) 25 mm dia nominal bore. B Class |
| 51 | S-2/2.39.1:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).15 mm dia nominal bore. |
| 52 | (B) 25mm dia nominal bore |
| 53 | S-2/2.3.1:- Making connection of GI distribution branch with GI main including all fitting : Upto 25mm dia |
| 54 | S-2/2.7.3:- P&F bibcock (IS : 8931 Mark) superior quality of approved make : C.P. Brass bib cock,15mm nominal bore. |
| 55 | S-2/2.11.2 :- P & F Ball cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. |
| 56 | S-2/2.12.1:- P&F inlet connection (Angle velves) superior quility of approved make for washbasin Gyset etc. CP intel connection 15 mm Brass (IS: 8931 marked) |
| 57 | S-2/2.14.3:-P&FFlushCock / FlushValve (IS :9758Mark)forWCofapproved quality make : exposed 25mm nominal bore. |
| 58 | S-2/2.15.1:- P&F Full way valve (IS: 778 mark) or wheel valve of approved make. (A) 2.15.1:- Gunmetal 15mm nominal bore |
| 59 | (B) 2.15.3:- Gunmetal 25mm nominal bore |
| 60 | S-2/2.26.3:- P&F PVC storage tank (IS: 12701 marked including the BIS license No.) of approved make with cover,25 mm dia IM long over flowing & 25 cm. Long wash out pipe with plug & socket, including making connection etc. Complete of approved deisgn : (A) 500 liters capacity. |
| 61 | S-3/3.16.3:- P&F rigid PVC pipe (IS:4985 mark) class II (4 KG./cm 2) appoved quality/ make incliding joint the pipe with solvent cement rubber ring and lubricant : 110 ,mm dia |
| 62 | S-3/3.17:- P&F rigid PVC pipe (IS:4985 mark) of appoved quality/ make incliding joint the pipe with solvent cement rubber ring and lubricant : 110 mm dia. (A) 3.17.9:- Bend 87.5˚ |
| 63 | (B)3.17.12:- Vent Cowel |
| 64 | S-3/3.22.3:-Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 Cm. dia outside & 240 Cm. depth. |
| 65 | S-3/3.27.1 :-Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) |
| 66 | S-3/3.19.1:- Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M |
| 67 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (A) Short point (upto 3 mtr)(E-1.1.1) |
| 68 | (B) Medium point (up to 6 mtr)(E-1.1.2) |
| 69 | (C) Long point (uo to 10mtr)(E-1.1.3) |
| 70 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR on Board.(E-1.3.1) |
| 71 | Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR(E-7.36) |
| 72 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/ casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR(A) 2x2.5 Sq.mm +1x1.5 sq.mm (E-4.1.7) |
| 73 | (B) 2x4 Sq.mm +1x2.5 sq.mm(E-4.1.14) |
| 74 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm(E-17.1.1) |
| 75 | Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR :1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ).(E-15.7.3) |
| 76 | Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .(7.20) |
| 77 | E-15/15.12.1Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball aring900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per re pproved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .300 mm sweep(900/1400 RPM) |
| 78 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR (A)LED Street Light fixture with Minimum lumen output 11225 lm (E-18.12.6) |
| 79 | E-18.18.3 Providing & Fixing of Street light bracket made out from following size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .32mm |
| 80 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4 Grade electrolytic alumnium conductor confirming to IS 8130, of purity >99.6 %, round / flat strip armouring of cable, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)includingtesting etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. (A)4.0 sqmm x2 core armoured (E- 11.2.1.1) |
| 81 | 6.10.1.1 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.: Metal door (Three phase) IK-09 and IP-43with Metal end box.4 Way (4+2) |
| 82 | Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR30 A / 40 A rating (E-6.2.1.1) |
| 83 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Single pole MCB (With B/C curve tripping Characteristics) 6A to 32A rating. (E-6.1.1.2) |
| 84 | P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. (5.9) |
| 85 | B-13/13.12 Repair to stone masonary in cement sand mortar 1:6 with old and new stone. |
| 86 | P-2/2.7.1:- Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all types of rocks including flushing of tube well and obtaining sand free water : Nominal bore 150 mm dia. |
| 87 | B-8/8.31 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. |
| 88 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge |
| 89 | B-9/9.39: Providing and fixing of double leaf steel shutter for cupboard the frame is made of pressed steel ISI section 80x25 mm x 1.25 mm thick with 1.00 mm MS sheet to spot welded includig holdfast of 15 x 3 mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direciton of Engineer in charge. |
| 90 | B-6/6.18.1: Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4 :upto 15 cm thick. |
| 91 | B-14/14.25:- Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 92 | B-11/11.17.1 :-Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)Light shade using shade cement. |
| 93 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy