SPECIAL REPAIR TO BLDG NO. OWT-76 AT STN HQ; SPECIAL REPAIR TO OR LIVING SHELTER (BLDG NO OWT-228); PROVN OF HY VEH PARKING SHED; PROVN OF FLOOR TILING IN BLDG NO. OWT-04 & OWT-05 (DOUBLE STOREY); PROVN OF WALL MOUNTED FAN, EXHAUST FAN AND ELECTRIC WATER HEATER ALONGWITH CONNECTED MISCWORK; PROVN OF 03 X GEYSER IN BATHROOM BLOCK (OWT-32) AT HTN HQ; PROVN OF THREE CLIMATE CONTROL DEVICES FOR BLDG NO. OWT-167 AND PROVN OF 02 X AC FOR CONF ROOM, CMPTR/SERVER ROOM & LAN SWITCH ROOM AT STN HQ AT BORARUPAK MIL STN MIL STN UNDER GE 872 EWS; 1 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish complete all as specified and directed. 2 Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal ofdebris and rubbish to a distance complete all as directed by the Engr-in-Charge 3 M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. 4 M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tilesincluding 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. 5 Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. 6 Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame)complete all as specified and directed. 7 S & F Rolled sections as in framing for cladding, glazing, chowkat and the like fixed with angle cleats and connecting plates, etc Conforming to Fe-290 (Gde E165) complete all as speicfied and directed. 8 M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etcincluding necessary form work complete all as specified and directed. 9 M & L for 35mm thick 2nd class hard woodPlain, framed, panelled shutters(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board mediumdensity, wood particle board with commercial face veneers: supplied and fitted to chowkatscomplete all as specified and directed. 10 S & F 30 mm thick, factory made, Second class hardwood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, etc.; sizes of members of shutters as specified in SSR Part I complete all as specified and directed 11 S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified anddirected. 12 S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified anddirected. 13 M & L for Mild steelChimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden rames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed. 14 S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed. 15 S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. 16 S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. 17 S & F 300 mmAluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt complete all as specified and directed. 18 S & FStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. 19 S & F 4 mm thick, sheet glass,ordinary quality and glazing with oil puttyin square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. 20 Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed 21 M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturers instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). 22 Supply only integral water proofing compound (ISI marked) complete all as specified and directed. 23 M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. 24 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. 25 Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 26 Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets/ snap grid frame etc complete all as specified and directed. 27 S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed. 28 S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instruction complete all as specified and directed. 29 S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturers instruction complete all as specified and directed. 30 S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturers instructions including 6 mm thick non asbestor E-board, HSPC, designer fixed to framecomplete all as specified and directed by the Engr-in-Charge. 31 M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. 32 Demolition ofStone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar and removing rubbish complete all as directed by the Engr-in-Charge. 33 M & L for 75 mm thick,plain cement concrete1:3:6, typeC-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. 34 M & L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc,including 20 mm thick screed bed in cement mortar 1:6 and set & jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed. 35 M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, cast in situ including necessary form work complete all as specified and directed. 36 S & F in repairs, 300 mm long,mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and directed. 37 M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. 38 M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. 39 M & L for Preparation of oldpainted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. 40 M & L for complete removal of existing paints on wall panel/plastered/ AC sheet boards etc surfaces and Preparation of new or previously untreated wall panel/plastered surfaces of any description over 10 cm girth or width not otherwise described and painting with two coats of synthetic enamel paint over a coat of alkali resistant primer by complete all as specified and directed. 41 M & L for preparing old decorated surfaces of wall/chajja, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of cement base paint complete all as specified and directed. 42 S & F Powder coated aluminium sections (minimum 50 micron) of approved colour as in door, window, ventilator frames, partitions with one or more rebates and door, windows shutters sliding/openable type/ventilator shutter including provision of necessary jointing cleats, glazing clips, neoprene rubber packing, powder coated aluminium snap beading, screws inclding provision of suitable size of powder coated aluminium fittings such as locking arangements, handles, stainless steel fiction hinges and tower bolts etc including fixing only glass panels/particle board panels/wire gauge/aluminium grill etc complete all as specified and directed. (Note : (i)The size of aluminium sections shall be all as specified in relevant IS Code and MES Schedule Part-I (ii) Glass panels/ Partricle Board panels/ Wire gaugeshall be measured paid seperately as supply only rates under respective items here-in-below). 43 Supply only 4 mm thick, sheet glass, ordinary quality and glazing with wooden beading/rubber beading exceeding 0.5 Sqm in each pane complete all as specified and as directed. (Note: The cost of rubber beads and fixing included with the unit quoted rate of respective shutter) 44 Supply onlyStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed.(Note: The cost of fixing included with the unti quoted rate of respective shutter) 45 S & F in repairStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. 46 S & F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 47 S & F in repairs 24 mm outer dia, stainless steel, curtain rail/rod, heavy duty, minimum 1mm wall thick including brackets, side holder and rings etc fixed to /wall etc complete all as specified and directed.(Note: (i) Stainless steel decorative finials and stainless steel brackets shall be provided for each leangth of curtain rail/rod and cost of the same shall deemed to be included in the unit quoated rate. (ii) Length of of curtain rail/rod shall only be measured for payments) 48 S & F in repair 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. 49 Surface dressing n.exc 15 cm deep as in soft/loose soil complete all as specified and directed. 50 Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified anddirected. 51 M & L for plain Cement Concrete1:3:6, type C-2 (using 40 mm graded stone aggregate) as in post, walls, retaining walls, ballast walls and the likes any thickness, above top of footings including attached pilasters and buttreses complete all as specified and directed. 52 M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed),trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed. 53 S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed. 54 M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 55 M & L for 100 mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etc complete all as specified and directed. 56 M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in flooring/hard standing, etc, and finished the cement concrete surfaces even and fair without using extra cement complete all as specified and directed. 57 M & L for Forming 12mm thick, Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100mm thick floor complete all as specified and directed. 58 M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as inroof kerb or mud stop, benching etc rounded or chamfered on edges incuding necessary form works etc complete all as specified and directed. 59 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. 60 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 61 Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. 62 M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) 63 All as per item No. 62 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto 64 All as per item No. 62 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto 65 All as per item No. 62 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFR (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFR (ISI marked) as earth lead complete ditto 66 S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. 67 S & F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. 68 S & F Switch socket combination 2 in 1, 3 pin, 6 Amp, flush type, universal complete all as specified and as directed. 69 S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. 70 S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. 71 S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. 72 S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. 73 S & F LED Bulb, 7 Watts, B-22 Lumen ≥ 500, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. 74 S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havells Cat No. LUMILINENEOBS20WLED840SPCSSIND or equivelant of make as per list of manufacturer) 75 S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specifiedand directed. (Make: Crompton Cat No. TIS-304-10-57-SL-DP-NWH or equivelant of make as per list of manufacturer) 76 Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor >0.94 Wattage and not more than 35 Watt, air delivery not less than 215cfm and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan and fixing in existing position including taking down existing unserviceable ceiling fan of any descriptions and deposited at MES store yeard complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years manufacturers warranty)(Make : USHA/Havells/Bajaj/CG) 77 S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havells cat part No. DHDNSHODAW04 or equivalent make as per List of Manufacturers) 78 S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed Havells cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturers) 79 S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havells cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturers) 80 M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. 81 S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09complete all as specified and as directed. (Make: Havells cat part No. DHDPSHODRW12 or equivalent make as per List of Manufacturers) 82 S & F MCB, TPN 40-63 Amps, 415 Volts, 10KA,C Curve complete all as specified and as directed(Make : Havells Cat part No. DHMGCTNF040 to 63or equivelant of make as perList of manufacturers) 83 S & F Wall mounted fan, 230 Volts, single phase, oscillating 450mm sweep, Superior low voltage performance, 2000 RPM hi air thrust, Thermal overload protector (TOP) including Pull cord control for a speed and oscillation On/Off suitable for wall mounting complete with all accessories and electric connection complete all as specified and directed (Make : Havells, Model : Airboll HS, FHWABHSWHT18 or equivelent model of make as per list manufacturer) 84 S & F wall mounted fan made of sturdy engineering plastic complete with speed regulator and wide osciliation control, 300 mm sweep, AC, single phase 230 Volts, 50 Hz, minimum RPM 1200, swing type, 45W, copper windind complete with all accessories and electric connection complete all as specified and directed (Make : Havells or equivalent model of Bajaj/Usha/ Khaitan/Orient as approved) 85 S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls complete all as specified and directed (Make : Havells, Model : Ventil Air DS or equivelant of make as per List of Manufacturers as approved) 86 Supply, install, testing & Commissioning, Geysers, water heater, 25 ltrs capacity, Storage type electrically operated on single phase 230 Volts AC, BEE 5 Star Rating with Double Safety Thermostat, Multi-function Safety Valve, High Density Insulation, Cathodic Protection, Superior Quality Glass-lined Inner Tank, and Single/Dual Glass-coated Incoloy Heating Elements, 8 bars highest pressure rating with minimum five years warranty on inner tank, magnesium anode energy saving ISI marked complete including grouting of nuts and bolts on wall for propper hanging of geyser with all accessories and connection of inlet & outlet pipe line including connecting up with 3 single core PVC insulated, multistranded copper conductor cables complete all as specified and directed.(Make : Jaquar Model No. Elena Prime or equivelent model as approved by the Engr-in-Charge/GE) 87 S & F chromium plated brass connection tube, 450cm long with two brass union and check nuts for connections to 15mm bore pipe suitable for hot water complete all as specified and directed. 88 Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 89 S & F 15 mm bore, bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 90 Supply, install, testing & Commissioning, Geysers, water heater, 2 KW, 35 ltrs capacity, Storage type electrically operated on single phase 230 Volts AC, BEE 4 Star Rating, steel body with copper inner tank and heating element, 2 KW capacity with all accessories such as safety valve, thermostate, NRV etc, energy saving ISI marked complete including grouting of nuts and bolts on wall for propper hanging of geyser with all accessories and connection of inlet & outlet pipe line including connecting up with 3 single core PVC insulated, multistranded copper conductor cables complete all as specified and directed.(Make : Havells Model No. GHWAHPTWH035 or equivelent model as approved by the Engr-in-Charge/GE) 91 M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casing cappingshall be measured as one length) 92 S & F sheet metal enclosurewith socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed. 93 S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for inputvariationbetween 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 4.0 KVA complete all as specified and directed. 94 Supply, install, testing & Commissioning, 3 STAR rated Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built advanced air filters for better indoor air quality with latest inverter technology, having eco friendly refrigerant gas, copper condenser coil, EER 3.2 or above of capacity 1.5 TR, summer cool, Inverter compressor, automatic 2D swing copper condenser, BLDC motor,necessary copper pipe connections including cutting, bending, brazing, insulation on pipes etc, PVC drain pipe, electric connection in between indoor and outdoor unit with suitable size of PVC insulated, multi-stranded copper cable complete with allfixing accessories such as bracket etc complete all as specified and directed. (Note: The unit rate quoted above shall deem to be inclusive of powder coated MS fixing brackets of suitable size for outdoor and indoor units at any height and copper tube of suitable size, drain pipe made of High Density Polyethylene pipes [HDPE] of pressure rating 6Kg/Sqcm of 20mm dia as required and 3 core, 4 Sqmm PVC insulated and PVC sheathed, heavy duty multi-stranded copper conductor cable, 1100 Volts, FRLS grade as required for connecting indoor and outdoor unit) 95 Supply, install, testing & Commissioning, 3 STAR rated Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built advanced air filters for better indoor air quality with latest inverter technology, having eco friendly refrigerant gas, copper condenser coil, EER 3.2 or above of capacity 2.0 TR, summer cool, Inverter compressor, automatic 2D swing copper condenser, BLDC motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipes etc, PVC drain pipe, electric connection in between indoor and outdoor unit with suitable size of PVC insulated, multi-stranded copper cable complete with allfixing accessories such as bracket etc complete all as specified and directed. (Note: The unit rate quoted above shall deem to be inclusive of powder coated MS fixing brackets of suitable size for outdoor and indoor units at any height and copper tube of suitable size, drain pipe made of High Density Polyethylene pipes [HDPE] of pressure rating 6Kg/Sqcm of 20mm dia as required and 3 core, 4 Sqmm PVC insulated and PVC sheathed, heavy duty multi-stranded copper conductor cable, 1100 Volts, FRLS grade as required for connecting indoor and outdoor unit) 96 S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for inputvariationbetween 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed. 97 Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. 98 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. 99 Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. 100 M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) 101 Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed. 102 Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing includingtaking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) 103 S & F in repairs, 40 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors as in protection pipe complete all as specified and directed. 104 Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing includingtaking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)