}

Tender For Estimate For Supply Of Non Dsr Item, chandrapur-Maharashtra

Forest Development Corporation of Maharashtra Limited has published Tender For Estimate For Supply Of Non Dsr Item. Submission Date for this Tender is 29-07-2025. Shed Construction Tenders in chandrapur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

50321613
Tender For Estimate For Supply Of Non Dsr Item
Tender
Indian
Maharashtra
Chandrapur
29-07-2025

Tender Documents

Tender Details

Tender For ESTIMATE FOR supply of Non DSR Item-SHED -1Providing, Fixing & Erection in position Pre-Engineered Building Shed covering area 6523.55 Sqm with following parameters including structural steel, roofing and side wall sheeting of all sides, canopy, insulation for roof etc completed. As directed by Engineer in charge PEB must be Design for Live Load (Kg/m2) on Roof 57 (Kg/sqm), Design Collateral Load (Kg/m2) 30 (Kg/sqm), Dead Load(kg/m2) on Roof 15(kg/sqm) including painting etc completeBuilding Parameters: 1. Type of FrameIC-1 2. Length159.5m o/o 3. Width 40.9m o/o 4. Eave Height8.470m 5 Interior Column spacing (m)2@20.45 6. Roof Slope1:20 7. Primary Bay Spacing (Length)2@8.448m + 17@7.923m + 1@3.975m + 1@3.947m 8. Wind BracingAs per Design 9. Eave Gutters & Downspouts will be provided in both sides (0.50mm Materials)10. Canopya. 5 No’s 1.5m Wide 5 No’s Considered (59 Sqm)b. 1 No’s 4.5m wide 1 No’s Considered (184 Sqm) 11. Frame Opening4mX4mX6 No’s & 4mx3mx1 No’s12. Roof MonitorConsidered throughout the length except1 & last bat.13. Cage Ladder2 No’s consideredOpen Wall Conditions: 1. Left Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 2. Right Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 3. Front Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 4. Back Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope)Roof & Wall Sheeting1. Roof PanelMinimum 0.55mm Thick Bare Galvalume Steel in KaizenStanding Seam Profile, Make -JSW/ TATA BSL.2. Wall CladdingMinimum 0.50mm TCT Colour Coated Galvalume Steel in Kaizen Hi-Rib Profile, Make- JSW/TATA BSL. 3 SHED 2Providing, Fixing & Erection in position Pre-Engineered Building Shed covering area 2597.15 Sqm with following parameters including structural steel, roofing and side wall sheeting of all sides, canopy, insulation for roof etc completed. As directed by Engineer in charge PEB must be Design for Live Load (Kg/m2) on Roof 57 (Kg/sqm), Design Collateral Load (Kg/m2) 30 (Kg/sqm), Dead Load(kg/m2) on Roof 15(kg/sqm) including painting etc completeBuilding Parameters:01.Type of FrameIC-102. Length63.50m o/o03. Width 40.9m o/o04. Eave Height8.470m05. Interior Column spacing (m)2@20.45 06. Roof Slope1:2007. Primary Bay Spacing (Length)2@8.332m + 6@7.806m 08. Wind BracingAs per Design09. Eave Gutters & Downspouts will be provided in both sides (0.50mm Materials)10. Canopy a. 5 No’s 1.5m Wide 6 No’s Considered (67 Sqm)11. Frame Opening4mX4mX6 No’s & 4mx3mx1 No’s12. Roof MonitorConsidered throughout the length except1 & last bat. 13. Cage Ladder2 No’s considered Open Wall Conditions: 01. Left Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 02. Right Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 03. Front Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 04. Back Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope)Roof & Wall Sheeting1. Roof PanelMinimum 0.55mm Thick Bare Galvalume Steel in Kaizen Standing Seam Profile, Make -JSW/ TATA BSL.2. Wall CladdingMinimum 0.50mm TCT Colour Coated Galvalume Steel in Kaizen Hi-Rib Profile, Make- JSW/TATA BSL. 4 SHED 3Providing, Fixing & Erection in position Pre-Engineered Building Shed covering area 2781.20 Sqm with following parameters including structural steel, roofing and side wall sheeting of all sides, canopy, insulation for roof etc completed. As directed by Engineer in charge PEB must be Design for Live Load (Kg/m2) on Roof 57 (Kg/sqm), Design Collateral Load (Kg/m2) 30 (Kg/sqm), Dead Load(kg/m2) on Roof 15(kg/sqm) including painting etc completeBuilding Parameters:01.Type of FrameIC-102. Length68.00m o/o 03. Width 40.9m o/o04. Eave Height8.45m05. Interior Column spacing (m)2@20.4506. Roof Slope1:2007. Primary Bay Spacing (Length)2@2.925+2@3.843+1@2.415+1@8.304+6@7.779M08. Wind BracingAs per Design09. Eave Gutters & Downspouts will be provided in both sides (0.50mm Materials)10. Canopy a. 5 No’s 1.5m Wide 5 No’s Considered (58 Sqm) 11. Frame Opening4mX4mX6 No’s & 4mx3mx1 No’s12. Roof MonitorConsidered throughout the length except1 & last bat.13. Cage Ladder2 No’s consideredOpen Wall Conditions:01. Left Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 02. Right Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 03. Front Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope) 04. Back Side WallCladding above 3m Brick Wall (Brick wall in Client’s Scope)Roof & Wall Sheeting1. Roof PanelMinimum 0.55mm Thick Bare Galvalume Steel in KaizenStanding Seam Profile, Make -JSW/ TATA BSL. 2. Wall CladdingMinimum 0.50mm TCT Colour Coated Galvalume Steel in Kaizen Hi-Rib Profile, Make- JSW/TATA BSL.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail