| 1 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.a) In second floor including roof. |
| 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 3 | 125 mm th. brick work with 1st class bricks in cement mortar (1:4) in ground floor. Add extra for each additional floor over the rate for ground floor on items from(16 to 22 and 25) except 18 of subhead Aa) upto 4th floor (See Page No-17,Item No-26) @ Rs. 12.00/Sqm |
| 4 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. |
| 5 | Reinforcement for Reinforced Concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. Including supplies of rods , initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4 m. JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL |
| 6 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)(d) Extra for works beyond the roof of ground floor per additional floor(i) upto 4th (per floor) and in basement @18.00/Sqm25 mm to 30 mm th. Wooden shuttering as per decision & direction of Engineer-in-Charge. |
| 7 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Note: Extra for Lifting Charges for each additional floor,i) Rs. 200/- per Cu.m (upto 4th floor)ii) Rs.250/-(above 4th floor) |
| 8 | Plaster (to wall, floor, celling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]ii) With 1:4 cement mortarExtra for each additional floor over the rate for ground floor items1 to 3 of subhead A :(See Page No- 193, Item No-©(01)(ii) Internal plaster ((a) Upto 4th floor add @ 4.00/Sqm) |
| 9 | (a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 10 | (A) Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary :(iv) Two coats (with any shade except white) |
| 11 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(b) On steel or other metal surface :a) Ordinary Teak Wood. |
| 12 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be supplied by the contrr](II) With Polymerised Adhesive [6 mm thick] & epoxy grouting materials for filling joints including spacer-2 mm [Applied directly over finished artificial stone floor/ mosaic etc] (A) Deep Colour & White |
| 13 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)Two coats |
| 14 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)Two coatsi) Water based interior grade Acrylic Primer |
| 15 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface. Two CoatsTwo coats |
| 16 | Child friendly items(L.S) |
| 17 | child friendly painting at wall(L.S) |
| 18 | Display board and photography |
| 19 | Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works [PWD/GS Page: E-2 Item:4a]25 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 20 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. [PWD/GS Page: E-9 Item:1]i) 3 x 22/0.3 (1.5 sqmm) |
| 21 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. [PWD/GS Page: E-9 Item:1]ii) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 22 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. [PWD/GS Page: E-9 Item:1]iii)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 23 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cumSwitch Board of the following sizes complete with three no.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment,painting and mending good damages to building works [PWD/GS Page: E-4 Item: 10] (a) 150 mm x 100 mm x 65 mm |
| 24 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cumSwitch Board of the following sizes complete with three no.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment,painting and mending good damages to building works [PWD/GS Page: E-4 Item: 10] (b) 175 mm x 100 mm x 65 mm |
| 25 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cumSwitch Board of the following sizes complete with three no.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment,painting and mending good damages to building works [PWD/GS Page: E-4 Item: 10] (c) 200 mm x 150 mm x 65 mm |
| 26 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works [PWD/GS Page: E-4 Item: 11] 100 mm x 100 mm x 65 mm |
| 27 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish.[PWD/GS Page: E-20 Item: 2] 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr |
| 28 | Distn. wiring with 2 x 36/0.3 (2.5 sqmm) single core stranded copper conductor PVC insulated and unsheathed copper wire (Brand approved by EIC) in 19mm dia 3 mm thick polythenepipe with 1x22/0.3 (1.5sqmm) PVC insulated and unsheathed coper wire as ECC, complete with all accessories embedded in wall (for 15 A plug point/EXHAUST FAN/Air Conditioner point)[PWD/GS Page: E-10 Item: 5] |
| 29 | Supplying and fixing 6 WAY double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good thedamages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provisionfor earthing attachment .6 way EnclosureLEGRAND (607716)[PWD/GS Page: D-10 Item:14] |
| 30 | S&F double-door (2+12) Way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall.(Legrand: (607712 /Siemense /Havells Metalica /ABB Elegance - as per direction of EIC)[PWD/GS Page: D-09 Item:13] |
| 31 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [PWD/GS Page: D-05 Item:06] 63A FP MCB |
| 32 | Supply & fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [PWD/GS Page: D-6 Item: 7]iii) 6-32A SP MCB |
| 33 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall forhousing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works . 8 Module [PWD/GS Page: E-17 Item: 9F/I ] |
| 34 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl.mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC[PWD/GS Page: E-20 Item: 3/a] |
| 35 | S&F 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[PWD/GS Page: E-18 Item: 9/b ] |
| 36 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. makingnecy. connections etc [PWD/GS Page: E-18 Item: 10 ] |
| 37 | supplying & installation split Air Conditioner of 1.5 Ton capacity 5 Star rating 230 V 50 Hz by supplying all required materials like copper tube etc with remote control all complete as per direction of EIC. |
| 38 | Supply &Fixing 48 inch AC ceiling fan complete with down rod,canopy fork ,blades,rubber bush with all accessories etc but without regulator including supply and fixing connecting wire for down rod upto 30cm including painting. MAKE HAVELLS/CROMPTON/BAJAJ/OTHER APPROVED. |
| 39 | Supply and fixing 18 inch 3blades metal body AC wall bracket fan on wall by supplyingand fixing rag bolts ,nuts and washers as required including S&F 24/.20 PVC insulated flexible copper wire0.5 mt length.MAKE HAVELLS/CROMPTON/BAJAJ/OTHER APPROVED. |
| 40 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below:(a) By ISI-Medium GI pipe [PWD/GS Page: G-1 Item: 2] |
| 41 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe I [PWD/GS Page: G-2 Item: 3/a] |
| 42 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode I[PWD/GS Page: G-2 Item: 3/b] |
| 43 | GST 18% |
| 44 | CESS 1 % |