| 1 | Taking down chowkhats or frames n. exc 1.5 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 2 | All as per itme No-1 here in above but exc. 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed. |
| 3 | S&F Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. framed filled with and including PCC 1:2:4 type B-0 (using12.5 mm stone aggregate) complete all as specified and directed. |
| 4 | S&F Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. framed filled with and including PCC 1:2:4 type B-0 (using12.5 mm stone aggregate) complete all as specified and directed. |
| 5 | S & F 35mm thick second class hardwood (Golden Teak) glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) complete all as specified and directed. |
| 6 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed. |
| 7 | S&F 35m thick factory made glazed and skeleton shutter open rebated and prepared to receive glass/ gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitered beads or clearing glass etc, size of members of shutters as specified in SSRpart I section 8 clause 8.20 (a) of IInd class hard wood complete all as specified and directed. |
| 8 | S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fireretardant and having screw holding capacity complete all as specified and directed. |
| 9 | S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed. |
| 10 | S&F of power coated ventilator fixed type and frame made with aluminium section with and including partly glass and partly stainless steel wire mesh and including aluminium grill of aperture not more than 40 sqcm (as specified below), aluminium sections shall be of size as given below including taking down old window/ventilator etc complete all as specified and directed by Engineer in Charge. Frame : 44.5 x 44.5 mm x 1.98 mm thick including 5mm thick frosted in glassfixed with rubber gasket with aluminium beading and stainless steel wire mesh of 0.63 mm nominal dia wire and average width of aperture 1.40 mm complete all as specified and directed. |
| 11 | S&F in repair aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make:- Sandhu/Ritz) shutter to be partly glaze with 5mm thick tined coloured glass in upper pannel and partly pannelled with 12mm thick both side laminated particle board in lower pannel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed . Chowkhat Frame:- 101.60x44.45x1.60mmShutter verticle style :- 85x44.45x1.56mm Shutter middle Rail :- 83.50x44.45x1.54mmShutter Top Rail and bottom Rail :- 114.30x44.45x1.55mm |
| 12 | S&F aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter andone noswire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows,and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long with stainless steel grill consisting of 12 mm square bar & 40 x 5 mm thick SS flat all around incl making good of existing surfaces with plaster and external (cement base paint)/ internal (OBD) finishes complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mmShutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36mmChowkhat bottom size : 50.30x26x1.20mmChowkhat top & sides size:50.30x26x1.00mm |
| 13 | S&F aluminium anodised partition with frame, (fixed type) shutter,and glazing 4.8 mm thick plain glass, and 12mm thick prelaminated particle board interior grade in bottom panell, glass fixed with rubber gasket with aluminium glazing clips & snap beading including taking down unserviceable existing partion etc of following sizes;-Frame of vertical/horizontal section;- 44.5x44.5x1.22 mm thickBottuom section;-100x44.5x1.22 mm thickComplete all as specified and directed by the Engr in chargeWork will be carried out up to 5th storeyMake: (i) Anodised aluminum section : Jindal / Hindalko/ Indalco. (ii) Particle board: Green ply/Kit ply/ Century ply (iii) Glass: Saint gobain / Modi guard / Tata |
| 14 | S&F in repair of Aluminium body door cill at bottom part of door to stop entry of insect inside the room complete all as specified and as directed. |
| 15 | S&F stainlesssteel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed. |
| 16 | S&F 4 mm thicksheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified |
| 17 | S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling holecomplete all as specified and directed. |
| 18 | S&F stainless steel barrel tower bolts 150 mm long one piece and fixed complete all as specified and directed. |
| 19 | S&F stainless steel butt hinges, medium weight 100 mm long one piece and fixed with screws/welded to frame complete all as specified and directed. |
| 20 | S&F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame complete all as specified and directed. |
| 21 | S&F 300 mm long stainless steel sliding door bolt (bolt not less than 12 mm dia) with hasp & staple and fixing clips of SS sheet, and SS fixing boltsand fixed complete all as specified and directed. |
| 22 | S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and directed. |
| 23 | M&L applying two coats of Synthetic paint on newwooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. |
| 24 | Dismantling of Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 25 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 26 | Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed |
| 27 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed |
| 28 | M&L applying two coats of synthetic enamel paint onnew or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed. |
| 29 | S&F in repair SS grade 204 drapery rod 20mm diaincluding decorative brackets, decorative finals at both ends complete all as specified and directed. |
| 30 | Demolition of concrete (un-reinfporced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified |
| 31 | M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and directed. |
| 32 | M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone agg as in sub base complete all as specified and as directed. |
| 33 | M&L non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mmthick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 34 | M&L glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match fixed over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existingwall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 35 | M&L non-skid / mat finish designed coloured joint free ceramic tiles of size400 mm x 400 mm x 6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existingtiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 36 | M&L double charged vitrified ceramic coloured tiles 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 37 | Demolition of stone slab and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed. . |
| 38 | M&L 18 to 20 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granitecomplete all as specified and directed. |
| 39 | S&F in repairs PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed. |
| 40 | S&F in repair vitreous China wash down (EWC) water closet pan(pedestal pattern), white (excluding flushing cistern and flush pipe) including seat and cover white for pedestal pattern complete all as specfied and directed. |
| 41 | S&F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed. |
| 42 | S&F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed. |
| 43 | S&F in repairvitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etccomplete all as specified and directed. |
| 44 | S&F in repair pillar taps, brass, with capstan head, fancy type chromium , screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. |
| 45 | S&F in repair brass chromium platedovehead shower with shower arm complete all as specified and directed. |
| 46 | S&F in repair 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 47 | S&F in repair 15mm bore Bib taps long bodycast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 48 | S&F in repair CP grating 100mm to 125 dia round fix on floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed. |
| 49 | Taking up or down steel tubing and connection incl removal from site bore of pipe 15mm complete all as specified and directed. |
| 50 | Taking up or down steel tubing and connection incl removal from site bore of pipe 20mm. |
| 51 | S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed. |
| 52 | S&F 20mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed. |
| 53 | M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cuttingn exc 10cm girthl complete all as specified & directed. |
| 54 | S&F in repair 75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed. |
| 55 | S&F in repair 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenchescomplete all as specified and directed. |
| 56 | S&F in repair75 mm bore UPVC (SWR) bend with oval acess door ,\"T\"socket reducer etc complete all as specified and directed. |
| 57 | S&F in repair110 mm bore UPVC (SWR) bend with oval acess door ,\"T \" socket reducer etc complete all as specified and directed. |
| 58 | Providing & fixing false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos \"T\" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \"T\" at 600 mm c/c toform a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main \"T\", bottom exposed width of 15mm of all \"T\"\" sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights as per direction of Engineer-in-Charge. |
| 59 | Demolition of Brickwork or stone/bou-lder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 60 | M&L brick work with sub class \"B\"brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 61 | M&L brick work with sub class \"B\"brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wallicomplete all as specified and directed. |
| 62 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified |
| 63 | M & L 15 mm thick renderingon brick work or concrete surfacein cement mortar 1:6, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 64 | M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 65 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 66 | M&L preparation of new plastered surfaces of external wall and application two coats of 1st quality exterior emulsion weather coatpaintsover a coat of alkali resistant priming paint complete all as specified and directed. |
| 67 | S&F factory made 100 % solid wood plastic composite (WPC) flush type shutter of 18mm thickness one side laminate consisting of panel of PVC profile of 18mm (+ 0.7mm) thick of denisity 600 kg per cum manufactured by ISO-9000 certified company using for shutter cillicia ply 18mm thick and fixed with frame.The thickness of shutter is edges painted by matching colour of PVC lining ofplain/prelim coloured PVC sheet as per manufacturer specification even and smooth without using extra cement complete all as specified and directed. |
| 68 | S & FContinuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm complete all specified and directed |
| 69 | S&F magnet catcher for cub board with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 70 | S&F Hasp and staple 100mm safety type, aluminium anodised with hinge pin including bolt to hinge plate and fixed with screws even and smooth without using extra cement complete all as specified and directed. |
| 71 | S&F 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) three layered, hoisted and fixed in position all as specified in SSR Part I including 20 mm brass float valve with PVC ball even and smooth without using extra cement complete all as specified and directed. |
| 72 | Provn of soakage well of sizeof 1.8 Mtr x 3.00 Mtr effective depth complete all as shown in HQ CE BZ Drg TD-.309 complete all as specified and directed. |
| 73 | M&L 65-70mm thick Pre-Cast Factory made RCC M-30 as in Cover Slab in different size of Manholes, Septic Tanks or Similar Articles with Plain Faces, all round 1mm thick plain sheet on the edge painted with bituminous paint on external surface incl reinforcementand RCC cover should be engraved CA No and MES and set in Cement Mortar 1:4, includingcomplete all as specified and as directed. |
| 74 | S&F 150 mm Salt glazed stoneware drain pipes, grade ‘A’complete all as specified and directed |
| 75 | M&L for in PCC (1:4:8) type D-2 (using 20 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed. |
| 76 | M & L for cuttingintoexistingmanholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required even and smooth without using extra cement complete all as specified and directed. |
| 77 | S&FCP Health Faucet with 1.20 mtr metalic Expandable tube & hook complete all as specified and directed and approved by Engr-in-Charge. |
| 78 | M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 79 | M&L for 60 mm thick pre polished rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and as directed. |
| 80 | M&L for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed. |
| 81 | M&L moorum/ red bajary filling in flloors or pavings, laid in layers n. exc. 15 cm thick, spread, levelled, and rammed including watering complete. |
| 82 | Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre depth for foundation, manhole etc not exc 10 Sqm on plan and not exc 1.5 metre in depth including getting out in soft/loose soil even and smooth without using extra cement complete all as specified and directed. |
| 83 | M & L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor etc even and smooth without using extra cement complete all as specified and directed. |
| 84 | Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25 centimetre in soft/loose soil complete all as specified and directed. |
| 85 | Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point even and smooth without using extra cement complete all as specified and directed. |
| 86 | S & F sub main wiringwithPVC insulated unsheathed FRLSH cable 1100 Volt grade,with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including one runPVC insulated unsheathedcable with multi stranded copper conductor colour code as a earth continuity and connected upto DBincluding taking down old unsv submain wiring of following sizes .Note:(i)Tworun of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface withusing PVC rawl plugs etc.(iii) Phasecolour code must be follow i.ePhase ( Red) and Neutral (Black) in colour and for three Phase RYB For phase and black for neutral. |
| 87 | 2 x 6 Sqmm+ 1 x 6 sqmm |
| 88 | 2 x 4Sqmm + 1 x 4 sqmm |
| 89 | S & F inreplacementMCB SP 240 volts \"B\" Curve 10 KA . including connection with suitable size copper lugs of following capacity |
| 90 | MCB SP 6 to32 Amp. 240 volts |
| 91 | MCB SPN 40to 63 Amps 240 volts |
| 92 | S & F in replacementDistribution box MCB Protected socket with Plastic enclosure (Surface mounitng ) 20 AMP MCB Combo box DP including plug top complete all as specified and directed |
| 93 | S & F in replacement4 way SPN CB DB, sheet metal enclosures double door.The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts with IK09 type with blanking plates where required and IP 43 degree protection of following size:- |
| 94 | Material and labour for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in non rigid PVC concealed conduit not less than 25mm diawith all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including Modular metal flush boxes 1.6 mm thick, upto 60 mm deep of required size factory made for mounting modular switch, regulators etc with inner /outer cover and frame(white) ISI marked, fixed with brass screwsincluding taking down unserviceable point wiringof any sizefor the following type .Note: (i)The quoted rates shall be deemed to be inclusive formaking good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (ii) Point wiring & earth wire shall be connected to each & every sunken box. |
| 95 | One light/fan/bell point controlled by one, one way switch 5 Amps |
| 96 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 97 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 98 | All as per item No.90above but with stranded copper conductor 4 Sq mm (nominal area), two single core, PVC insulated cable 1100 Volt grade ISI markedfor 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 4 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly. |
| 99 | S & Fin replacement fan regulator modular step type 120W 240 volts 2 module typecomplete all as specified and as directed. |
| 100 | S & Fin replacementModular switch single pole one way 6 Ampcomplete all as specified and as directed. |
| 101 | S & Finreplacement Modular switch single pole one way 16 Ampcomplete all as specified and as directed. |
| 102 | S & F in replacement Modular socket outlet 2/3 pin combined 6 Amp 240 voltscomplete all as specified and as directed. |
| 103 | S & FinreplacementModular socket outlet 2/3 pin combined 16 Amp 240 voltscomplete all as specified and as directed. |
| 104 | S & Finreplacement Modular bell push flush type, 5 Amps complete all as specified and as directed. |
| 105 | S & F in replacement Electric ding dong bell 230 volts ACcomplete all as specified and as directed. |
| 106 | S & Finreplacement ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated bodycomplete all as specified and as directed. |
| 107 | S & Fin replacementBatten holder, PVC/polycarbonate type with back plate suitable for batten fittingscomplete all as specified and as directed. |
| 108 | S&F in replacement Exhaust fan 300 mm sweep,not more than 900 RPM, made up of Sturdy Engineering Plastic complete, voltage 230Volts, 50 Hz,complete with louvers, shutters and connecting up ceiling rose to connectorblock of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. |
| 109 | S&F BLDC Ceiling Fan completeaccessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , complete connecting up ceiling rose to connector block of fan including fabricating and fixing ofFan hooks from ceiling truss/angle iron, required length of down rods (Aas per site requirement) and necessarynuts and bolts complete all as specified and directed. |
| 110 | S&F in replacementhigh prssure die cast alluminium LED Batten light fitting 20W ,125 lumens /watt,IP-20,colour temp not less than 6500,inbuilt electronic driver, PF not less than 0.90 , inbuilt surge protection minimum 2.5KVcomplete all as specified and as directed. |
| 111 | S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable sizecomplete all as specified and as directed. |
| 112 | S&F decorative wall mounting lamp holder made out of polycarbonated suitable for and incl retrofit 9 watt LED bulb complete all as specified and as directed. |
| 113 | S&F LED building securitylight fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 114 | Material and labour for Earthing complete with galvanized ironearth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board andtesting on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc.GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed.Note: (i) Earth lead wire and its protection pipe upto and including 7.5 mtrfrom the top of earth electrode are included under this item.(ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. |