Repairing, Testing And Re-Commissioning Of Existing Fire Detection System At Balurghat Dh, Dakshin Dinajpur.Rn 25000328, (Project Id : Hf252633963s000), balurghat-West Bengal

Public Works Department has published Repairing, Testing And Re-Commissioning Of Existing Fire Detection System At Balurghat Dh, Dakshin Dinajpur.Rn 25000328, (Project Id : Hf252633963s000). Submission Date for this Tender is 05-08-2025. Flame Detectors Tenders in balurghat West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50295369
Repairing, Testing And Re-Commissioning Of Existing Fire Detection System At Balurghat Dh, Dakshin Dinajpur.Rn 25000328, (Project Id : Hf252633963s000)
Tender
Indian
West Bengal
Balurghat
05-08-2025

Tender Documents

Tender Details

Repairing, Testing and Re-Commissioning of existing Fire Detection System at Balurghat DH, Dakshin Dinajpur.RN 25000328, (Project ID : HF252633963S000)- 1 Checking, Rectification, Re-Installation, Testing and Re-Commissioning of Addressable fully networkable fire alarm control Panel EN Standred VDS approved 4 Loops Expendabele upto 18 loop, loop card wich will have 127 devices of both detectors and modules in a single line circuit on any combination. (Approved Make: Honeywell-Esser) 2 Checking, Re-Installation, Testing and Commissioning ofVDS approved Addressable Multi Sensor - Smoke cum Heat detector with ROR features to raise an alarm when the temperature reaches 11.1°per Minute with inbuilt fault isolator withbase with Binary coded address setting. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base as required. (Approved Make: Honeywell-Esser) 3 Checking,, Installation, Testing and Commissioning VDS approved of addressable type loop sounder wall mounted type rated at 100± 5 DBA @ 1m for Audible annunciation, Fire Sires Sound, Indoor type IP40, ABS plasticas required.(Approved Make: Honeywell-Esser) 4 Checking, ,Installation, Testing and Commissioning of VDS approved addressable Manual Call Point -Single Actionwithback box and Break Glass Rod, shall be resettable by Align key to avoid unauthenticated restorations with extra acceesories as required. (Approved Make: Honeywell-Esser) 5 Supply & Fixing of Manual Call Point Glass. (Approved Make: Honeywell-Esser) 6 Supply & Fixing of 12 V 7 Ah SMF Battery. (Approved Make : Exide) 7 Supply, Installation, Testing and Commissioning of VDS/UL/LPCB approved Addressable Multi Sensor - Smoke cum Heat detector with ROR features to raise an alarm when the temperature reaches 11.1°per Minute withbase with Binary coded address setting. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base as required.(Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton/Notofire) 8 Supply ,Installation, Testing and Commissioning of VDS/UL/LPCB approved addressable Manual Call Point -Single Actionwithback box and Break Glass Rod, shall be resettable by Align key to avoid unauthenticated restorations with extra acceesories as required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton/Notofire) 9 Supply, Installation, Testing and Commissioning VDS/UL/LPCB approved of addressable type loop sounder wall mounted type rated at 100± 5 DBA @ 1m for Audible annunciation, Fire Sires Sound, Indoor type IP40, ABS plasticas required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton/Notofire) 10 Supply ,Installation, Testing and Commissioning of Addressable fully networkable fire alarm control Panel VDS/UL/LPCB approved 1 Loop expendable upto 4 Loop capacitywith each loop card wich will have 250 devices of both detectors and modules in a single line circuit on any combination, SLC should supports both Class A and Class B wiring. Shall have an LED indication for FIRE, Normal and Redundancy conditions which consists of display board which will have 160 Character Displaywith Touch key pad, Mother board which will have ARM CORTEX M3 32 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, Two inbuilt programmable inputs, Two inbuilt NACs, and Three Programmable Relays. power Supply Board, having minimum 1000 event memory, which will have SMPS fully protected board, which its operates on 120 to 220V AC± 10% with 50/60 Hz, battery backup 24V DC with built-in charger.the panel have IP-50 rating complete as required and as per specification. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton/Notofire) 11 NOTE :-1) The Fire Alarm system shall comply with latest requirements of--(i) National Fire Protection Association (NFPA) Standards,(ii) IS 2189 ,(iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. 12 TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. 13 TERMS & CONDITIONS :- 14 The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 15 Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules. 16 Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab/KEI ) through 19 mm dia PVC FR type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. 17 N.B- The Rate to be quoted by all the bidders should be inclusive of all taxes, duties including GST & CESS etc.

Key Value

Document Fees
Refer document
EMD
INR 12080.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail