Tender For Building Electrification Of Block 108C At Inrp Site,Tarapur.; 1 Supply, Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door, with R Y B Phase indication and MCB position indication through glass front, IP-54, Prewired with HFFR copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick, powder coated with RAL7035 shade, pre-galvanized G.I. sheet steel, suitable for surface mounting/installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar, brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, etc. as per drawing, specifications & generally as per relevant IS, SLD, Technical specification & as per instructions of Engineer-in-charge. 2 MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. 3 Supply 4 Installation 5 MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. 6 Supply 7 Installation 8 MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 24 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. 9 Supply 10 Installation 11 Supply, Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, with Phase indication and MCB position through glass front, Pre wired with HFFR copper wires, IP-54, MCB Distribution Board fabricated out of 2mm thick Pre Galvanized G. I sheet steel, powder coated with RAL7035 shade, suitable for surface mounting/installation in existing enclosure complete with appropriate rating of tinned copper bus bar/Cu Wire, neutral bus bar, brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, earth bar, din bar for MCB mounting, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, check-nuts etc. as required as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in- charge. 12 MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB 40A DP RCBO (100mA) and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. 13 Supply 14 Installation 15 MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB 40A DP RCBO (100mA) and 12 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. 16 Supply 17 Installation 18 Supply and Installation of the following Industrial/modular MCB and metal clad/polycarbonate plug sockets with suitable industrial plug tops ( 3-pin) along with surface mounted powder coated GI Box with suitable mounting arrangements on wall and 3 pin domestic plug sockets with suitable PVC Box, switch and plug tops as per Technical specifications. 19 1 nos. of 10A and 1 nos. of 20A, Single phase Industrial Socket with Isc=10kA, Type C-Curve, Industrial type MCB for each Socket along with pre- Galvanised powder coated GI sheet steel Face Plate, Industrial Plug Tops and suitable DIN rail and mounting arrangements along with surface mounted powder coated 2mm thick GI Box with suitable mounting arrangements onwall as per technical specification. 20 Supply 21 Installation 22 1 no. of 6A and 1 no of 16A, Single phase Industrial three pin Socket with corresponding Type C-Curve, Industrial type MCBs, Isc=10kA,along with pre- powder coated GI sheet steel Face Plate, Industrial Plug Tops and suitable DIN rail and mounting arrangements as per technical specification. 23 Supply 24 Installation in existing embedded GI Box 25 1 nos. of 10A Single phase Industrial Socket with Isc=10kA, Type C-Curve, Industrial type MCB for Socket along with pre- Galvanised powder coated GI sheet steel Face Plate, Industrial Plug Tops and suitable DIN rail and mounting arrangements along with surface mounted powder coated 2mm thick GI Box with suitable mounting arrangements onwall as per technical specification. 26 Supply 27 Installation 28 1 no of 6A and 1 no of 16A, Single phase Modular Decorative Type Socket with Polycarbonate box, piano Switch for each Socket and heavy duty polycarbonate Face Plate, along with concealed/surface mounted enclosure, plug topsand suitable surface mounting arrangementsas per technical specification. 29 Supply 30 Installation 31 1 nos. of 6/10A,Single phase Industrial Socket in Pre-Galvanised powder coated 2mm thick GI sheet Box,suitable for surface mounting, industrial plug top with chained metal cover for the socket outlet,suitable din-rail,face plate,suitable copper lugs,plug-tops,SS screw/nut bolts for surface mounting. 32 Supply 33 Installation 34 1 nos. of 6/10A,Single phase Industrial Isc=10kA, Type C-Curve, Industrial type MCBSwitch box in Pre-Galvanised powder coated 2mm thick GI sheet Box,suitable for surface mounting,,suitable din-rail,face plate,suitable copper lugs,plug-tops,SS screw/nut bolts for surface mounting. 35 Supply 36 Installation 37 2 nos. of 6/10A,Single phase Industrial Isc=10kA, Type C-Curve, Industrial type MCBSwitch box in Pre-Galvanised powder coated 2mm thick GI sheet Box,suitable for surface mounting,,suitable din-rail,face plate,suitable copper lugs,plug-tops,SS screw/nut bolts for surface mounting. 38 Supply 39 Installation 40 3 nos. of 6/10A,Single phase Industrial Isc=10kA, Type C-Curve, Industrial type MCBSwitch box in Pre-Galvanised powder coated 2mm thick GI sheet Box,suitable for surface mounting,,suitable din-rail,face plate,suitable copper lugs,plug-tops,SS screw/nut bolts for surface mounting. 41 Supply 42 Installation 43 Supply, Fabrication and Installation of Standard steel sections as per IS 2062 Grade BR for equipment supports, base frame for panels, wall frames and brackets for installation of lights/ equipments, earth pit cover plates, Anchor Fastners etc. Fabrication shall include drilling, entiling, welding wire brush cleaning, testing DPT etc., supply of all consumables like gas, approved welding rods, Zinc coating paint finish during installation as per EIC and tender tech spec. After fabrication two coats of epoxy based primer and two coats of finish paints shall be applied. 44 Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100 V as per the IS: 3961 (part V) - 1968.As per conductor class 2 of IS: 8130 / 1984 as per technical specification 45 1.5 Sq. mm 46 2.5 Sq. mm 47 Installation/drawing through concealled/ surface conduit and wiring, wire connection through Push wire Inline Splicing Connector for solid and stranded wires upto 2.5 sqmm, transparent housing, Transparent cover and termination at both ends of Single Core HFFRwires ( Copper )of size mentioned below in voltage grade 1100 V as per the IS: 3961 ( part V ) - 1968.As per conductor class 2 Type-C of IS: 8130 / 1984 as per technical specification 48 1.5 Sq. mm 49 2.5 Sq. mm 50 Supply, Installation, Testing and Commissioning of LED light fittings with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, complete withlight fitting accessories, includingsupply of fixing accessories, twin twisted tinned 1.5 sq. mm copper flexible cords for terminal connections, 16 SWG copper wire forearthing , flexible GI metallic conduit sleeves, PVC conduit bushes, cable lugs and testing and commissioning as per the specification of the following: 51 Industial box type, 4ft Functional with 2x18W LEDreplaceble type Tubewith light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, with a nominal system lumen output of 2350 lumens per LED tube.The luminaire should have a color temperature of 6500K and CRI>80. minimum 110 lm/w efficacy, THD < 10% and PF > 0.95. The batten luminaire housing should made of white powder coated CRCA sheet steel. The LED shall be mounted on extruded aluminium strip which acts as heat sink and is intergral part of tube which is made up of polycarbonate material which gives diffused light. The total power consumption should not exceed 44W (including driver). 52 Supply 53 Installation, Testing and Commissioning 54 LED Bulkhead with a nominal system lumen output of not more than 1100 lumens and a minimum system efficacy of 110 lm/W. The luminaire should have a color temperature of 6500K and CRI > 80. The luminaire shall meet IP66 rating and IK 08 rating with THD < 20% and PF > 0.9. The luminaire housing should made of High pressure die cast Aluminium with high quality PMMA diffuser. The total power consumption should not exceed 10W (including driver). 55 Supply 56 Installation, Testing and Commissioning 57 LED Lowbay light fitting complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, LED Low bay wide beam of 35W having System Efficacy >120 lm/W, lumen output of 4300lumens system outputTHD<10%,PowerFactor >0.95, CRI >80, , CCT 6500, Full IP 65 protected pressure die cast aluminium (LM6) housing having integrated PC lens cover with Impact resistance IK08. Operating temp. -10 degrees to 50 degrees C. BIS compliant driver, EMC -EMI compliant. Driver shall have 10KV Surge protection. Shall have eye bolt hook for surface/ suspended mounting. 58 Supply 59 Installation, Testing and Commissioning 60 LED Flatline light fitting complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, LED with wide beam of 32W having System Efficacy >120 lm/W, lumen output of 3300lumens system outputTHD<10%,PowerFactor >0.95, CRI >80, , CCT 6500, Full IP 20 protected pressure die cast aluminium (LM6) housing having integrated PC lens cover with Impact resistance IK08. t. Driver shall have 4KV Surge protection. Shall be suspended at proper height. 61 Supply 62 Installation, Testing and Commissioning 63 LED peripheral luminaire with a normal system lumen output of 4200 lumens and minimum efficacy of not less than 120lumen/watt. The luminaire should have CCT of 5700K anda CRI>70.The luminaire shall meet IP66,IK07 rating with THD<10% & pf>0.9. The luminaire housingshould be made of pressure die cast aluminium. The total power consumption should not exceed 25W (including BIS compliant integrated driver) and other requirements shall be as per tender technical specifications. 64 Supply 65 Installation, Testing and Commissioning 66 Supply and surface conduiting of heavy duty rigid GI ERW conduit pipe of 25mm sizes along with all accessories such as inspection bends, junction box, socket, check nut, etc. including making threads, removing burrs, connection of accessories, drawing of fish wire, cleating with heavy duty GI saddle or suit to site clamps on RCC wall, column, steel structure . as required under the instruction of Engineer in charge. 2mm thick powder coated GI surface type junction box with suitable mounting arrangements shall be provided. 67 Supply 68 Installation 69 Supply and laying of 14 SWG ETP grde bare solid copper conductor throughout along the conduit including fixing with ties, brazing etc as required. 70 Supply 71 Installation 72 Supply of required material and making of exothermic braze joints of copper conductor with other conductor or copper earthing pad including removal of burrs and debris as per technical specification and instruction of engineer in charge. 73 Supply of Print, Copy, Scan, Send and Optional Fax ,Highly Efficient A3 Monochrome Laser Multifunctional printerswith feature such as platen cover type z,inner finisherwith 2 Tray ,545 sheet capacity ,Inner 2 wqay Tray M1,cassette feeding unit 74 Installation