| 1 | Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in hard/dense soli complete all as specified and directed. |
| 2 | Excavating in trenches for hard/ dense soil, n. exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm complete all as specified and directed. |
| 4 | Excavating in post holes (orsimilar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earthor broken rubble mixed withearth around, in layers not exceeding 25 cm soft / loose soil complete all as specified and directed. |
| 5 | Removing excavated material n.exc 50m and depositing where irected at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 6 | M&L for PCC1:3:6 type C2 using 40mm graded stone aggregate) in foundation filling mass concrete complete all as specified and directed. |
| 7 | M&L for brick work built in cement mortar 1:6 straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 8 | M&L for 15mm thick cement plaster in cement mortar 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc complete all as specified and directed. |
| 9 | M&L for three coats of white wash on newly plastered surfacesincluding preparation of new surafaces complete all as specified and directed. |
| 10 | M&L for hard core of broken stone of guage n.exc 63mm deposited, spread and lovelled in layers n.exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 11 | M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed. |
| 12 | M&L for machine pressed precast concrete interlocking paver block any shape and size size conforming to IS-15658-2006 of60mm thickness M-35m Gradewith grey cement and pigment complete all as specified and directed. |
| 13 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 14 | M&L for cement concrete Type B1 1:2:4 (20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 15 | S&F for Pre-painted galvalume aluminum zinc coating steeltrapizoidal/corrugated 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 16 | S&F for Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 complete all as specified and directed. |
| 17 | M& for Painting to steel Surfaces of any description, over 10cm in width or grith with two coat of synthetic enamel paint over a coat of red oxid, not otherwise described complete all as specified and directed. |
| 18 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab of manholes, septic tank etc,set in cement mortar (1:4) including necessary form, moulds etc and including taking out/removal of existing unserviceable cover slab from manholes /septic tank complete all as specified and directed.Note :- Reinforcement shall be measuredand paid separately. |
| 20 | S&F for 150 mm dia Reinforced concrete pipes,class NP3, laid and jointed complete with collars with cement mortar (1:1) complete all as specified and directed. |
| 21 | M&L for PCC (1:3:6) type C-2 (40mm graded stone aggregate) as in bed to drain pipes incl packing under and completely surrounding pipes with concrete after they are laid and tested for 150 mm dia pipes complete all as specified and directed. |
| 22 | S&F for mild steel Fe-410-W(GdeE-250) quality-B Rolled sections as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20mm of the length indicated complete all as specified and directed. |
| 23 | S&F for Steel work in Roof trusses (framed) trussed purlins, crane gantries purlins, rails and fastenings and heavy bracketframing (beam, tee, angle, channel or flat section) including distance pieces cleats etc complete all as specified and directed. |
| 24 | M&L for preparation of newplastered surfaces of walland applying two coats of cement base paint complete all as specified and directed. |
| 25 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) on surface wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including modularmetal flux box, top cover blank plate etc for housing switches, socket outlets, fan regulators etc duly earthed . |
| 26 | Three light point controlled by one way switch 5/6 amps. |
| 27 | S&F for switch 1 way 6 Amps,230 volts, 50 HZcomplete all as specified and directed. |
| 28 | S&F for inverter type batten LED light fitting of capacity 1X 20 W (or nearest next higher wattage) (4feet), 6500K, wall/ surface mounted,square profile housing and polycarbonate channel including lithium lon battery with charging time 8 hours and back up time up to 4 hours decorative type with integrated high efficiency electronic driver and operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and directed. Make :- Havells, Cat part no . Pride Plus inverter Batten 20 W. |
| 29 | S&F for sheet metal enclosure, MCB DB, double door, single pole & neutral, 4 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 30 | S&F for MCB single pole and neutral, 32 Amps, 230 volts, 10 kA, C series complete all as specified and directed. |
| 31 | S&F for MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unsv one complete all as specified and directed. |
| 32 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 33 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified.Note: Punned thickness of sand shall be measured & paid. |
| 34 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 35 | S&F for GI protection pipe of 40 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed.Note:- Earth work shall be measured and paid separately. |
| 36 | Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor,10 sqmm,2 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 37 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6.30mm thick elecrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm as earth lead by means ofbolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 38 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 X 3 mm copper strip complete all as specified and directed. |
| 39 | M&L for GI Pipe light grade 32 mm dia for the protection of down conductor complete all as specified and directed. |
| 40 | S&F for gun metal black or phosphorus bronze size 75mm x 75mm x 25mm drilled screwed including 3 Nos, 8mm dia and 25mm long neckhead screws including MS box 2mm thick of suitable size for protection of test point terminal complete all as specified and directed. |
| 41 | S&F for suitable sized heavy duty bridge/post porcelain/mini busbar insulator on wall / roof with suitablesize of PVC plugs / gutties,screws for fixing copper strip incl. making good the disturbed surfaces complete all as specified and directed. |
| 42 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |