}

Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works Of 7.2 Mld Stp And 7 Kld Septage Co-Treatment Facilities 2 Design, Construction, Supply Of All Materials, Erection And Commissioning Of 7., dhampur-Uttar Pradesh

Uttar Pradesh Jal Nigam has published Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works Of 7.2 Mld Stp And 7 Kld Septage Co-Treatment Facilities 2 Design, Construction, Supply Of All Materials, Erection And Commissioning Of 7.. Submission Date for this Tender is 01-08-2025. Building Work Tenders in dhampur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50251679
Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works Of 7.2 Mld Stp And 7 Kld Septage Co-Treatment Facilities 2 Design, Construction, Supply Of All Materials, Erection And Commissioning Of 7.
Tender
Indian
Uttar Pradesh
Dhampur
01-08-2025

Tender Documents

Tender Details

Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities 2 Design, Construction, Supply of all materials, Erection and Commissioning of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities with all the civil,LT/HT panel room, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.6m wide, area approx 2000sqm),fiiling of earth if required]fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned)., staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement,sanitation work) etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology OR any proven technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained asper CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. The cost is inclusive of (Peak flow 24.11 MLD) (civil works). 3 INTERCEPTOR SEWERExcavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including (8% reduction due to excavation already taken in manhole and SCC) 4 (a)0.00 to 1.50 m 5 (b) 01.50 to 03.00 m 6 (c) 03.00 to 04.50 m 7 Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete 8 (a)1.5 to 3 m 9 (b) 03.00 to 06.00 m 10 Same as item No. 3 but for open timbering (No timbering for depth <1.50m) 11 (a) 1.50 to 03.00 m 12 Timbering left in trenches (No timbering for depth <1.50m) 13 Open Timbering left in trenches (used timbering) 0-3m depth 14 Closed Timbering left in trenches(used timbering)0-3m depth 15 Closed Timbering left in trenches(used timbering)3-6m depth 16 Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 17 600 mm dia 18 700 mm dia 19 Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment600 mm dia pipe 20 01.50 - 0 3.00 m 21 03.00 - 04.50 m 22 700 mm dia pipe 23 01.50 - 0 3.00 m 24 Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. 25 (c) 03.00 to 04.50 m 26 Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. 27 (b) 01.50 to 03.00 m 28 Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm)for class B bedding (granular bedding) 29 Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement. 30 1200mm internal dia., 3.30m deep 31 1500mm internal dia., 4.95m deep 32 Extra for every additional depth of 1 m or part there of in following size of circular manholes. 33 1200mm internal dia., 3.30m deep 34 1500mm internal dia., 4.95m deep 35 Dismantling/Cutting of Cement Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer Incharge. 36 Reinstatement of Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer Incharge. 37 Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. 38 Disposal of Surplus Earth as per direction of Engineer Incharge. 39 Construction of Boundary Wall 2.0m ht. above plinth level 0.23m width with RCC Column @3m c/c with plinth beam and foundation avg. 2 m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site 40 MS gate (3.6m wide with 1.50m wicket gate with 0.35 m x0.35m RCC piller) 41 Cnstruction of Intermediate Pumping Station (IPS) as per specification, accesory building & design approved by Engineer in Charge 42 Sewage Rising main from IPS Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer Incharge. 43 0.0 to 1.5 mtr. Depth (do - in all kindes of soil) 44 Supply of 400mm dia. DI K9 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329- 400 mm 45 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(400mm) 46 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm 47 Carting of 400mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 48 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing 49 Sluice valve, Air valve chambers 50 Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 51 Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 52 Interception and diversion (I&D) Structure works 53 Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge 54 Treated Effluent line (400mm Dia DI K7) (STP to Disposal point (Khow river) 55 Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.0.0 to 1.5 mtr. Depth do - in all kindes of soil 56 Supply of 400mm dia. DI K7 pipe and special for the pumping mains including all complete Pipes conforming to IS : 8329- 400 mm 57 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.all complete required for completion of work (400mm dia) 58 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. all complete required for completion of work150 mm 59 Carting of 400mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 60 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing. 61 Sluice valve, Air valve chambers 62 Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 63 Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 64 E/M WORKS 65 STP ( 7.2 MLD ) And Co Treat ment Plant ( 7 KLD ) 66 A. Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (7.2 MLD )with all required electrical& mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender documentfor STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentrationmentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panelwith considering load of STP and MPS both.B. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 7 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (3 KL/H) with double cylinder having VFD for its operation , 1000 Lit. PVC tank for washing screw press machine. all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 2HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run of 1 No. 1500 Lit. Cesspool Vehicle having 30 HP Reputed make Tractor (with Registration Certificate and insurance papers) 67 E./M. Works at MPS 68 Electrical Works 69 H.T.Panel( Comprising with 1 -I/C and 2 -O/G. (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 70 SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 71 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. (1set, included in STP costing) 72 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) (2 sets, included in STP costing) 73 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. (included in STP costing)3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) -60 metersTrench making and covering of trench in all respect.- 60 metersSITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 4 sets11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV - 2.5 SqmTransformer:Suitable capacitywith Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (included in STP costing) -- 2 Nos. 74 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 63 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 75 LT Cable laying and jointing 76 Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 77 Earthing 78 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 79 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 80 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 81 Charges of Electrical safety Clearance 82 Expenditure on B&L Form, Challan etc. 83 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 84 STARTER PANEL 85 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 86 Mechanical Works 87 PumpThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 3110 lpmTotal Head= 16 M or as per designSpeed=980Quantity of pumps. 88 Guid Rail System 89 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set.(6 Sets, included in item no. 51.01) 90 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (6 Sets, included in item no. 51.01) 91 Main piping and Valves.Main piping and valves 200 mm dia delivery, 350 mm diacommon header line. 92 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 93 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 94 Motor Operated Sluice Valves 95 Sluice Valve 200 mm dia 96 Sluice Valve 350 mm dia 97 Reflux Valve 98 Reflux valve 200 mm dia N.B. 99 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m . 100 200 mm, K9 delivery pipes for all six pumping plant 101 350 mm, K9 common header pipes 102 Specials like bend, tee, D Joint etc. 103 Nut Bolt, Washer Rubber packing etc 104 INSTALLATION, TESTING & COMMISSIONING 105 Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above. 106 Level Transmitter (For Hi-Lo cut-off & alarms) 107 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 108 Electro magnetic flow meter 109 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 110 E.O.T. Crane 111 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 112 Chequerred plate and guards 113 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 114 PAINTING 115 Painting of all pumps piping and valves with two coat enamel paint. 116 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 117 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 118 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 119 IPS Campus with Solar Panel and LED Light of 3 sets. 120 D.G. SET AND ACCESSORIES 121 SITC of Radiator Cooled and Turbo charged Silent type suitable capacity DG set , engine ,alternator capable of developingat 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. (1 set, included in stp costing) 122 SITC of PLC Based Auto main failure (AMF) Panel forDG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.(1 Set, included in stp costing) 123 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.(2 Job, included in stp costing) 124 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. (2 Jobincluded in stp costing) 125 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. (1 Job, included in stp costing) 126 Providing and Laying cable for DG Set to Panel ( armored aluminium )-(1 Job, included in stp costing) 127 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm. (4 Jobs, included in stp costing) 128 SCREENS AND GATES: 129 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 130 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at mid year peak discharge (1w+ 1s) 131 Packing and Frieght 132 Installation, Testing and Commissioning 133 AUTOMATION OF MPS 134 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 135 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 136 CE/UL certified intellignet Smart Energy Meter 137 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 138 160 AMP rating 139 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 140 CE/UL Certified Surge protector for control panel. 141 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters. 142 Security Survillance IP Camera with recorder 143 Installation, commissiong & testing of above automation work 144 Expenditure on Operation & Maintenance of MPS including automation, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period 145 E./M. Works at IPS Dhampur 146 Electrical Works 147 H.T.Panel( Comprising with 1 -I/C and 2 -O/G .(panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 148 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 149 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) 150 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 151 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) 152 SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) 153 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break DownVoltage 45 KV 154 Transformer: 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of 315 KVA rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. 155 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 156 SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 No outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay & one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 3 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 400 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 2 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 100 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (E) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (F)APFC Panel for total load.(G) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 157 LT Cable laying and jointing 158 Power and control cable-Supply of 240 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 240 sq. mm X3 core-1 run cable for power from starters to 67 KW Motors & 35 sq. mm X3 core-1 run cable for power from starters to 15 KW Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 159 Earthing 160 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 161 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 162 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 163 Charges of Electrical safety Clearance 164 Expenditure on B&L Form, Challan etc. 165 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 166 STARTER PANEL 167 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 90 HP motor (To be fixed in composite panel of LT Panel) 168 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 169 Mechanical Works 170 Large PumpsThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 5750 lpmTotal Head= 40 M or as per designSpeed=980Quantity of pumps. 171 Guid Rail System 172 Guide rail system (Automatic coupling system) for 90 HP submersible pump setscomplete for above pump set.(3 Sets, included in item no. 94.01) 173 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (3 Sets, included in item no. 94.01) 174 Small Pumps 175 Thesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (1W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump=2500 lpmTotal Head= 17 MSpeed=980Quantity of pumps. 176 Guid Rail System 177 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set. (2 Sets, included in item no. 98.01) 178 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (2 Sets, included in item no.98.01) 179 Main piping and Valves. 180 200 mm dia delivery for small pumps and250 mm dia delivery for large pumps, 350 mm diacommon header line. 181 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 182 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 183 Motor Operated Sluice Valves 184 Sluice Valve 200 mm dia 185 Sluice Valve 250 mm dia 186 Sluice Valve 350 mm dia 187 Reflux Valve 188 Reflux valve 200 mm dia N.B. 189 Reflux valve 250 mm dia N.B. 190 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing . 191 200 mm, K9 delivery pipes for small pumping plants 192 250 mm, K9 delivery pipes for large pumping plants 193 350 mm, K9 common header pipes 194 Specials like bend, tee, D Joint etc. 195 Nut Bolt, Washer Rubber packing etc 196 INSTALLATION, TESTING & COMMISSIONING 197 Installation & Commissioning of allPump set,Piping & Valves as mentioned in above @5% of supplied items. 198 Level Transmitter (For Hi-Lo cut-off & alarms) 199 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 200 Electro magnetic flow meter 201 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 202 E.O.T. Crane 203 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 204 Chequerred plate and guards 205 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition(3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 206 PAINTING 207 Painting of all pumps piping and valves with two coat enamel paint. 208 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 209 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 210 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 211 IPS Campus with Solar Panel and LED Light of 3 sets. 212 D.G. SET AND ACCESSORIES 213 SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 250 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. 214 SITC of PLC Based Auto main failure (AMF) Panel for 250 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. 215 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. 216 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. 217 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. 218 Providing and Laying cable for DG Set to Panel 240 sq mm X 3.5 core x 2 run( armored aluminium ). 219 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 240 sq mm. 220 SCREENS AND GATES: 221 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 222 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge (working) 223 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge( standby) 224 Packing and Frieght 225 Installation, Testing and Commissioning 226 AUTOMATION OF IPS 227 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 228 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 229 CE/UL certified intellignet Smart Energy Meter 230 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 231 160 AMP rating 232 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 233 CE/UL Certified Surge protector for control panel. 234 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 235 Security Survillance IP Camera with recorder 236 Installation, commissiong & testing of above automation work 237 3 month trial run of automation work 238 Expenditure on Operation & Maintenance of IPS during 3 month Trial and Run Period 239 Expenditure onDiesel Consumption of IPS during 3 month Trial and Run Period 240 Expenditure on Electricity Consuption of STP, MPS & IPS as per actual UPPCL bill during 3 month Trial and Run Period

Key Value

Document Fees
INR 23600 /-
EMD
INR 1564000.0 /-
Tender Value
INR 15.63 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail