Tender For Construction Of New Gym Centre At Near Bus Stand In Manalurpet Town Panchayat; 1 Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc.,as per SS 20 A. TNDSS NO: 23 & 24 VI (S2) VI,VII 9,10with standard specifications. 2 Plain Cement Concrete 1:4:8 Mix (one part cement, four part sand and Eight part of aggrigate) using 40 mm size ISS HBG metal from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing. Laying and curing etc., complete as per TNDSS NO : 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge. 3 Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using new best II Class Bricks of size9 ” x 4 3/8 “x 2 3/4 ”from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. 4 Supplying and fabrication of steel and placing in position of TMT steel rods for RCC works as per design given including cost of steel and GI binding wire in all floors etc., complete complying with standard specification in TNDSS NO:97 V,VI (S6) VII (S6), VII-3. 5 Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86.a) Column Shuttering 6 Grade Beam 7 Roof Slab 8 Reinforced Cement Concrete 1:1½:3 Mix (One part cement, one and half part sand and three part of aggregate)using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing but excluding cost of reinforcement etc.Complete with std.Specifications. TNDSS NO: 30 V, VI (S3), VII-3. 9 Paving the floor with descrgned coloured vitrified tiles of size 600 x 600 x 8mm of best quality and approved variety complying / confirming ISI specification land over cement mortar 1:3 (one cement and three M- Sand) 20mm thick and pomted with same coloured cement neatly etc., complete. 10 Special ceiling Plastering in Cement Mortor 1:3 Mix (one Cement, Three sand ) 10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. 11 Plastering in Cement Mortor 1:5 Mix (one cement, five sand) 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. 12 Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., 13 Providing UPVC (Un-Plasticized Polyvinyl Chloride)Door: Providing and fixing casement doors fabricatedfrom un-plasticized polyvinyl chloride (uPVC)sections.Profiles: The profiles should be three chamber system which provides high insulation properties with outerframe 60mm x 55mm with an outer wall thickness of2.4mm. The window unit should be designed with allcorner joints mitred and fusion welded. Windowsshould be steel reinforced with 25 x 24 x 25mm steelreinforcement with a thickness of 1mm to havedimensional stability. The sash should be of 60 x102mm. The mullion should be of 60 x 74mm. Theprofiles should have co-extruded seals.Hardware: All the hardware like friction stays, handlesshould be screwed with self tapping screws. Thehandles, locks should be designed so that they cannotbe released from outside.Glazing: The window system should beglazed with5mm plain float glass / 6mm bison lamInstallation: The profiles should be cut to length andwelded 45 degrees. The window should bedesignedsuch that the water drainage does not pass throughthe reinforcement chamber. The window systemshould be fixed directly to the plastered brick wallusing self expanding nylon plug and driving mselectroplated screws into plug. PWD SOR Page No : 70 Sl. No : M - 0673 14 Supply and fixing of Collposible gate andM.S Grills for Windows,with one coat of Red oxidePrimer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. including phosphating as per ISI with rust preventive primer & ready to assemble condition for easy installation at site including dismantlingmaking necessary with power drill to the accessories such as supplying and fixing holdfasts, plastic bush inserts receiver runner bottom shock absorbers etc. and Steel DoorComplete as Directed by the Departmental Officer. 15 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work PWD SORPage No : 70 Sl. No : M - 0673 16 Supplying andfixingofpush and pull type Rolling shutter confirming to IS 6248/1979 and as amended from time to time. With ISI make of approved size and section using 18 gauge G.I.sheet.The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of Hood covers , transportation charges etc., and as directed by Engineer incharge. 17 Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) (SD.NO.24) 18 Supply and fixing of single box type 440W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting (SD 88) 19 Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point (SD12) 20 Supply and fixing of 1200mm (48) sweep AC ceiling fan complete with stepped electronic regulator, with 1 meter down rod with fan clamp with side plates and cross arm of size 450mm (18) (SD NO. 106) 21 supply and fixing of TNEB meter board suitable for 32 A single phase service connection with 32A fues unit (500 V) 32A neutral link and earth link (1X18 copper flat) on TW plant of size 375mm X 300mm X19 with supporiting TW reepers of 1 thick an either side withpainting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wirefrom EB meter to fuse unit (SD No.125) 22 Supply and run of 4 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade on 7/20 GI bearer wire for service connection mains (SD No.65) 23 Supply and run of 4 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm G.I pipe (Class B bent at both ends with necessary angle iron up right and end supports for mains(SD No.70)